• 제목/요약/키워드: Cable failure

검색결과 180건 처리시간 0.026초

반도전 재료를 이용한 Resistivity grading 방식의 XLPE절연 전력케이블용 시험단말에 관한 연구 (A study on the application of testing termination for XLPE Power Cable by Resistivity Grading Method Using Semi-conductive material)

  • 이창영;신두성;;김동욱;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1105-1107
    • /
    • 1999
  • The purpose of termination for high voltage tests of XLPE power cable is to prevent flashover during the breakdown test of specimen as well as to withstand the specified voltage between its conductor and screen without failure. For easier treatment and simpler construction of testing termination, resistivity grading method using semi-conductive material was employed. Based on the fundamental theory, its failure characteristics by changing the resistivity of semi-conductive material on the insulation surface was investigated. With two layers construction by difference resistivity on their surfaces, much improved result than that of one resistivity was obtained through the experiment for MV cable.

  • PDF

실 계통의 혼합송전선로에서 CCPU파괴 원인과 그 대책 (The Cause of CCPU's failure and Improved Configuration Method in Combined Transmission Lines)

  • 하체웅;김정년;이수길;허회덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.210-212
    • /
    • 2001
  • The protection of underground cables against transient overvoltages resulting from lightning and other causes is important in cable-tine which is connected with overhead line and underground cable. This paper investigates the failure of CCPU(Cable covering Protection Unit) and presents improved configuration method of CCPU in underground cable system EMTP(Electromagnetic Transient Program) is used in order to study the overvoltages and modeling of components of the system such as overhead lines, underground cables, CCPUs and towers in presented.

  • PDF

국내 지중 케이블 고장현황 분석 (Failure Analysis of Underground Transmission Cable Systems)

  • 강연욱;조성배;곽방명;임헌의;윤형희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2377-2379
    • /
    • 1999
  • In order to analyze failure rates of underground transmission power cable systems in Korea, the survey has been performed for the failure cases of cables, joints, and terminations in CV, OF and POF cable systems which occurred from 1983 to 1998. During 16 years, the failure cases due to trips of the systems were 47 among the total 108 cases, These 47 cases could be divided into internal reasons(manufacture/installation, corrosion and degradation) of 16 cases and external reasons (external mechanical damages, lightning, fire. etc.) of 31 cases. For the 154 kV cable systems during 12 years from 1987 to 1998, total failure rate was 0.0057 [case/100C-km/year] and internal reason failure rate was 0.0020 [case/100C-km/Year], which is similar to those of foreign countries. Also, the many cases of internal reason failures occurred in the early stage after the operations due to incorrect installations. This implies that the installation process is very important and some diagnostic tests such as PD measurement are needed besides after laying test.

  • PDF

케이블 연결 소켓의 인장강도 (Tensile Strength on Connection Socket of Cables)

  • 박강근;이장복;하채원;김재봉
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.37-42
    • /
    • 2008
  • 구조물에서 케이블 부재는 압축이나 휨이 없이 인장력에 의해서 하중을 전달하는 시스템이다. 케이블 시스템은 대공간 구조의 지붕, 공기 지지구조, 프리스트레스 막구조, 케이블 네트워크 구조, 현수구조, 가이드 타워, 해양 프래트폼, 현수교 등의 구조물에 널리 사용되어 왔다. 케이블 부재는 부재 단부에 소켓, 스웨이징, 스프라이스 슬리브, 클립, 웨지, 루프 스프라이스 등에 의해서 하중을 전달 할 수 있다. 본 연구에서는 케이블 연결 소켓의 인장강도에 대한 실험을 수행하고자 한다. 실험결과에서 대부분의 시험체가 케이블이 파단하중에 도달하기 전에 소켓의 연결부에서 파단이 일어났다.

  • PDF

Feeder Cable Assembly의 가속수명시험법 개발 (Test methodology of acceleration life test on feeder cable assembly)

  • 한현각
    • 한국산학기술학회논문지
    • /
    • 제17권8호
    • /
    • pp.62-68
    • /
    • 2016
  • Feeder cable assembly는 정보통신용 자동차부품이다 기능을 제대로 하지 않으면 자동차의 제어와 안전에 큰 문제가 발생한다. 가속수명시험은 시험시간을 단축할 목적으로 짧은 시간에 잠재적인 고장모드와 고장을 찾기 위하여 기속조건(스트레스, 스트레인, 온도 등)에서 실험을 실시하는 것이다. 고장원인은 부품의 품질과, 고장으로 유도하는 공정, 디자인에 의해 발생하는 결함이다. 열충격은 온도차에 의하여 부품의 열팽창 정도가 다른 것에 기인한다. 열충격시험은 부품이 급격한 온도차를 견디는 능력을 실험하는 것이다. 본 연구에서는 가속시험의 coffin-manson 식을 이용하여 정상조건(최고온도 $80^{\circ}C$, 최저온도 $-40^{\circ}C$)과 가속조건(최고온도 $120^{\circ}C$, 최저온도 $-60^{\circ}C$)을 이용하여 가속계수를 계산하여 2.25 값을 얻었다. 정상조건에서 1,000 사이클 실험이 가속조건에서 444 사이클 실험만하여도 됨을 알 수 있었다. Bx 수명 식을 이용하여 가속조건에서 시료가 5개, B0.04%.10years 조건에서 747 사이클 결과를 얻었다. 정상조건에서 1,000 사이클, 가속조건에서 747 사이클 실험한 feeder cable assembly 시료 5개를 각각 네크워크 분석기를 이용하여 성능시험을 실시하고, 와이블분포의 모수분포값을 비교한 결과 가속이 잘 되었음을 알 수 있었다. 동등한 신뢰도에서 가속실험을 통하여 시험시간을 1/4 정도 단축할 수 있었다.

서울메트로 전력케이블 장애현황 분석 (Seoulmetro Power Cable's Obstacle situation analysis)

  • 위삼복;정노건;김재문;김양수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1611-1612
    • /
    • 2015
  • This research paper is to analyze the specific situation for the 157 failure cases of Seoul Metro power cable since 1990 and to consider the countermeasures. This is, also, to prevent accidents by analyzing the current state of each Line, the failure of causes, railroad tracks, installation year, opening year, and monthly failure conditions and by presenting the countermeasures. In addition, this research is to discuss the present installation situation of Seoul Metro power cable, the types of power cable, symptoms, causes and the countermeasures.

  • PDF

지중배전 케이블의 노화에 의한 가교도 특성 (Crosslinked Characteristics of XLPE Cables by Aging)

  • 이우선;조준호;최권우;정창수;정용호;김상용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1566-1568
    • /
    • 2000
  • This study refers to the crosslinked characteristics of XLPE cables by aging. The cable failure brings about an enormous loss of power supply and the immense expense for cable replacement. These characterization techniques can be used for identifying a cause of failure and for improving a quality of equipments Also, these play an important role in the detection of premature failure. In order to maintain a cable reliability, quality control is needed strictly. It can be possible to estimate a residual lifetime of power cable using characterization techniques.

  • PDF

FDS 이용한 주제어실 화재시 케이블 기능상실시간 평가 (Cable Functional Failure Time Evaluation for a Main Control Room Fire using Fire Dynamic Simulator)

  • 임혁순;김인환;김명수
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.79-85
    • /
    • 2016
  • 원자력발전소의 방화지역에서 전기적인 단락, 지락, 전기회로 개방 등의 전기 문제로 화재가 발생할 수 있다. 전기 화재가 발생할 경우 안전계통 및 관련기기의 안전정지 기능이 상실된다. 이러한 사고를 예방하기 위하여 안전계통은 다중성, 독립성으로 설계되어 있다. 그러나 케이블 화재시 운전원은 오동작, 잘못된 지시 및 계측으로 발전소 상황을 잘 못 판단하여 적절한 조치를 하지 못할 수 있다. 따라서 주제어실 화재시 케이블 기능상실온도에서 최소 운전원 조치 요구시간인 5분은 매우 중요하다. 본 논문에서 주제어실 화재시 케이블의 기능상실온도 시간을 분석하여 운전원 조치시간이 충분한지 평가하여 주제어실 화재에 대한 안전성을 확인하였다.

Experimental and numerical study on tensile capacity of composite cable-girder anchorage joint

  • Xuefei Shi;Yuzhuo Zhong;Haiying Ma;Ke Hu;Zhiquan Liu;Cheng Zeng
    • Steel and Composite Structures
    • /
    • 제49권2호
    • /
    • pp.215-230
    • /
    • 2023
  • Cable-girder anchorage joint is the critical part of cable-supported bridges. Tensile-plate anchorage (TPA) is one of the most commonly used types of cable-girder anchorage joints in steel girder cable-supported bridges. In recent years, it has been proposed by bridge designers to apply TPA to concrete girder cable-supported bridges to form composite cable-girder anchorage joint (CCGAJ). In this paper, the mechanical performance of CCGAJ under tensile force is studied through experimental and numerical analyses. Firstly, the effects of the external prestressing (EP) and the bearing plate (BP) on the mechanical performance of CCGAJ were investigated through three tests. Then, finite element model was established for parametrical study, and was verified by the experimental results. Then, the effects of shear connector forms, EP, BP, vertical rebar rate, and perforated rebar rate on the tensile capacity of CCGAJ were investigated through numerical analyses. The results show that the tensile capacity of CCGAJ depends on the first row of PR. The failure mode of CCGAJ using headed stud connectors is to form a shear failure surface at the end of the studs while the failure mode using PBLs is similar to the bending of a deep girder. Finally, based on the strut-and-tie model (STM), a calculation method for CCGAJ tensile capacity was proposed, which has a high accuracy and can be used to calculate the tensile capacity of CCGAJ.

원자력발전소 케이블 노출 화재 시 기능상실온도 분석 (Cable Functional Failure Temperature Evaluation of Cable Exposed to the Fire of Nuclear Power Plant)

  • 임혁순;배연경;지문구
    • 한국화재소방학회논문지
    • /
    • 제26권1호
    • /
    • pp.10-15
    • /
    • 2012
  • 원전 방화지역에서 화재가 발생할 경우 안전정지 케이블은 단락, 접지, 단선 등 전기적 고장으로 케이블에 고장이 발생하여 그 결과로 안전정지계통의 설비와 기기는 안전정지 기능을 상실할 수 있다. 따라서 원자력 발전소 안전정지계통의 설비와 기능은 다중설계, 계열간 독립 및 분리 원칙에 따라 운영되고 있다. 케이블 화재의 경우 기기 오동작과 오지시 또는 잘못된 계측을 유발할 수 있으며 운전원의 상황 판단에 오류를 일으켜 안전정지 기능을 저해할 수 있다. 본 논문에서는 원자력발전소 케이블 화재 조사 및 원인 분석, 케이블 화재온도 및 기능상실 기준 및 국내 원자력발전소에서 사용중인 케이블을 선정하여 노출 화재 시 케이블 기능상실 온도를 분석하여 케이블 안전성을 확인하였다.