Assessment of material analysis for Halogen free flame retardant concentric neutral type Power cable (난연성 동심중성선 전력 케이블의 재료에 대한 평가 기술)

  • Soh, Jin-Joong;Shim, Dae-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1460-1462
    • /
    • 2002
  • The test methods on materials of electrical power cable are used in accordance with 25 specifications of IEC, ASTM, ICEA, KS and KEPCO Spec. The validation of test methods were checked and stablished by solving the problems occurred during the test. These tests are flammability, degree of acidity of gases, amount of halogen acid gas, smoke density, oxygen index, amount of ion in semiconductor, void, amber, contaminant and water tree, crosslinked density. Then the performance of power cable made by A, B, C and D company were evaluated and compared.

  • PDF

Harvesting Cost and Productive of Tree-Length Thinning in a Pinus densiflora Stand Using the Tower Yarder (HAM300)

  • Cho, Minjae;Cho, Koohyun;Jeong, Eungjin;Lee, Jun;Choi, Byoungkoo;Han, Sangkyun;Cha, Dusong
    • Journal of Forest and Environmental Science
    • /
    • v.32 no.2
    • /
    • pp.189-195
    • /
    • 2016
  • Logging equipment and method have a major influence on harvesting productivity and cost. This study investigated the productivity and operational costs of tree-length cable yarding system using HAM300, a domestically developed tower yarder. We tested HAM300 for thinning operation in Pinus densiflora stands at Gangreung, Gangwon-do on April, 2014. To assess the productivity we conducted time study for each stage of the operation. When the average time/cycle was examined for each stage of the operation, the longest was for yarding (241 sec), followed by delimbing (237 sec), felling (153 sec), and processing (103 sec). Furthermore, productivity for felling was $8.6m^3/hr$, followed by delimbing ($5.1m^3/hr$), yarding ($3.5m^3/hr$), and processing ($8.1m^3/hr$). The total cost for the tree-length logging system was $58,446won/m^3$, of which the majority was incurred by the yarding cost at $46,217won/m^3$ (79.3%), whereas the lowest cost was for felling at $2,359won/m^3$ (4.1%). We suggest that it is necessary to foster specialized operators and provide training in operating the tower yarder thereby implementing efficient harvesting system resulting from low-cost yarding.

Human Reliability Assessment for a Installation Task of Temporary Power Cables in Construction Fields (건설현장 임시전력 배선의 가설직무에 대한 인간신뢰성 평가)

  • Kim Doo-Hyun;Lee Jong-Ho;Kim Sang-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.61-66
    • /
    • 2005
  • This paper presents an human reliability assessment(HRA) for a installation task of the temporary power cable in construction fields. HRA is evolved to ensure that the workers could reliably perform critical tasks such as a process of the temporary power cable. Human errors are extremely commonplace, with almost everyone committing at least some errors every day. The considerable parts of electric shock accidents in the construction field are caused by a series of human errors. Therefore it is required to analyze the human errors contained in the task causing electric shock event, the event tree analysis(ETA) is adopted in this paper, and particularly human reliability was estimated for a installation task of the temporary power cables. It was assumed that the error probabilities of the human actions may be obtained using the technique for human error rate prediction(THERP). The results show that the predominant task on reliability in the cable installation tasks is check-out tasks and the probability causing electric shock by human errors was calculated as $1.0\times10^{-9}$.

A Study on Prediction of Treeting Breakdown in XLPE Cable According to Method of Acoustic Emission Detection (음향방출 계측법에 따른 가교폴리에틸렌 케이블의 트리잉 파괴 예지에 관한 연구)

  • 김재환;박재준
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.4
    • /
    • pp.26-33
    • /
    • 1993
  • The acoustic emission automatic detection system is developed to observe tree deterioration phenomena. Applying an alternating voltage of 15(kVnns) toXLPE tree specimens, many pulses of small amplitude are detected when the bush type tree developes branch type and a few pulses of high amplitude prcxluced as branch type propagated to bush type tree. Therefore, it is known that pulses having small amplitude operates as a destructive factor. It is observed that the skewness of the amplitude and the number of average pulses as distribution tendency of three dimension are characteristic quantity of AE pulses. As the trajectory of skewness is farther from the origin on the S-plane, it is more likely to breakdown.

  • PDF

Selection Criteria of Harvesting and Logging Methods in Consideration of Forest Terrain Characteristics (산림지형특성(山林地形特性)을 고려한 산림수확방법(山林收穫方法) 및 집재방법(集材方法)의 선정기준)

  • Kim, Ki Weon
    • Journal of Korean Society of Forest Science
    • /
    • v.82 no.2
    • /
    • pp.195-206
    • /
    • 1993
  • The purpose of this study is to provide a basis for establishing regional harvesting systems that ist the prerequisites for the forest mechanization. The factors restricting to the forest harvesting and logging methods from topographical aspects are studied for this purpose. Three main harvesting methods studied in this paper are : shortwood method, longwood method and full tree method. This study shows : the shortwood method is suitable for low, the longwood method for medium, the full tree method for high topographical conditions. For the logging methods, the focus of the study is on various ground based logging systems by animalpower, manpower, gravitation, wheeled & crawler vehicle and cable. The factors limiting the coverage of logging operation are slope and logging distance. The cable crane logging methods are classified by logging distance into short distance(to 300 or 400m), middle distance(to 700 or 800m) and long distance cable crane methods (over 700 or 800m). The wheeled vehicle method shows serious damages to forest resources, whereas the logging by log-line of the gravitation logging method and cable crane method tend to minimize such damages. The wheeled & crawler vehicle method also shows difficult to apply in the high slope conditions, whereas cable crane method can be applied to maximum 120% steep slope and uphill conditions.

  • PDF

Analysis on Electrical Tree Growth Characteristics in XLPE According to Crosslinked Degree (XLPE의 가교도 분포에 따른 전기트리 진전 특성 분석)

  • Kim, Sang-Ki;Kim, Dcuk-Keun;Lee, Jeong-Bin;Lee, Jin;Kim, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.901-903
    • /
    • 1998
  • Crosslinked Degree is an important factor to determine dielectric property of crosslinked polyethylene(XLPE) used for the insulation material in power cables. Recently, though it is necessary to investigate electrical properties according to crosslinked degree as a part of the whole characterization of cable. it is not examined closely. In this study, crosslinked degree of samples were measured according to temperature and holding time of crosslinking, electrical tree characteristics of these samples were analyzed by crosslinked degree and applied temperature that was changed from normal temperature to operating temperature of power cables. As a result. when the crosslinked degree was low, dielectric properties were decreased and influence of temperature was increased. but the crosslinked degrees were high. initiation voltages of treeing were increased and dielectric properties were improved. It is proved that the optimum. crosslinked degree was one of most important factor for aging time and residual lifetime of power cable.

  • PDF

Risk Assessment of Energy Storage System using Event Tree Analysis (ETA를 이용한 에너지저장시스템의 위험성 평가)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Eui-Sik;Park, Young-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.34-41
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on six items of ESS: the whole system, battery, BMS, PCS, ESS and cable. To achieve that, ESS work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew initiation events (IE) and end states (ES). ETA is applied to the main functions of each item, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events ; loss of grid electricity of ESS, loss of battery electricity(DC) of battery, impairment of electric function of BMS, loss of grid electricity(AC) of PCS, loss of data of EMS, Mechanical damage of cable, event sequence analysis conducted on the basis of event trees. If the suggested IEs and ESs are applied on the basis of ESS event cases, it is expected to prevent the same kinds of accident and operate ESS safely.

Efficiency Estimation of Toxicity Free Eire Resistance Cable

  • Yoon, Hun-Ju;Hon, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.3
    • /
    • pp.34-38
    • /
    • 2002
  • In this paper, efficiency estimation of toxicity fee fire resistance cable experiments was measured smoke density of toxicity free fire resistance polyolefin insulation material and electric field dependence of tree shape in low density polyethylene (LDPE). One of the most serious causes of failure in high-voltage cables, can be an electrical discharge across an internal gab or void in the insulating material. Treeing due to partial discharge is one of the main causes of breakdown in the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation and research of the fire resistance character has become important. First, we have studied on electric field dependence of tree shape in LDPE about treeing phenomena occurring on the high electrical field. Second, the measurement method is the attenuation quantity of irradiation by smoke accumulating with in a closed chamber due to non-flaming heat decomposition and flaming combustion. A main cause of fire-growth and generating toxic gas when, it bums, should be dealt with great care in life. safety design. The fire gases were occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC, which has high content of carbon in chemical compound.

Probabilistic Safety Analysis of Cable-Stayed Bridge Using Measured Data (계측데이터를 이용한 사장교의 확률적 안전도 분석)

  • Yoon, Man-Geun;Cho, Hyo-Nam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.175-182
    • /
    • 2008
  • In this paper, through the study and consideration of the recently prominent monitoring of cable stayed-bridge, practical but reasonable suggested for the evaluation of the probabilistic safety of the bridges using probable measured data from monitoring measurement system. It is shown in the paper that the live load effects can be evaluated using measured data of cable-stayed bridge and this the realistic probabilistic safety of the cable-stayed bridge could be assessed in term of element reliability and system reliability. As a practical method for the evalution of the system reliability of system cable-stayed bridges partial ETA method is uesd, which can find the critical failure path including combined failure modes of cable, deck and pylon. Compared with the conventional safety analysis method, the propsed approach may be considered as the practical method that shows the considerably actual and reasonable results the system redundancy of the structure.

A Study on Electric Properties and Accelerated Water Tree Degradation of Environmental-friendly Non-crosslinked Polyethylene (친환경 비가교 폴리에틸렌의 전기적 특성과 워터트리 가속열화에 관한 연구)

  • Lee, June-Ho;Kong, Tae-Sik;Kim, Seong-Jung;Kwon, Ki-Hyung;Lee, Jae-Soon;Gu, Gwang-Hoe;Cho, Kyu-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.827-832
    • /
    • 2012
  • The crosslinked polyethylene (XLPE) is the most widely used insulating material for power cable. Due to its thermosetting characteristics, the XLPE can not be recycled, while the needs for the environmental friendly and recyclable insulator is rapidly increasing. In this paper, some important and basic electrical properties of non-crosslinked polyethylene such as conduction current characteristics, water the tree characteristics, AC breakdown test were experimentally investigated. It was shown that some of the tested samples had better performances from the application point of view for replacing current XLPE.