• 제목/요약/키워드: Cable Integrity

검색결과 33건 처리시간 0.025초

지중배전케이블 외피용 컴파운드의 이온투과 특성 비교 (Effect of Ionic Impurities in Materials for CN/CV Underground Distribution Power Cable Jackets)

  • 김동명;권태호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.167-168
    • /
    • 2008
  • The permeation of $Ca^{2+}$ ions through the materials such as polyvinyl chloride (PVC) and non-halogenated flame retardant cross linked polyolefin (FR-XLPO) used for CN-CV underground distribution power cable jackets was investigated. The permeation of $Ca^{2+}$ ions was found to increase with the increase of time. The FR-XLPO showed higher permeation of $Ca^{2+}$ ions, by a factor of about two, than the PVC. This was explained by the destruction of structural integrity caused by mixing a large amount of mineral flame retardant such as $Mg(OH)_2$ used to impart non-flame ability to the jacket material.

  • PDF

현수교 PPWS 가설중 형상관리를 위한 PPWS 새그 및 장력민감도 산정법 개발 (Development of Sag and Tension Sensitivity Estimation Method for Configuration Control under PPWS Erection in a Suspension Bridge)

  • 정운;서주원;이원표
    • 대한토목학회논문집
    • /
    • 제32권5A호
    • /
    • pp.255-266
    • /
    • 2012
  • 현수교 주케이블은 완성시 교량의 구조적 건전성을 나타내는 중요한 지표이다. 주케이블은 가설완료시 자유 매달림(free hanging) 상태의 형상이 되며 교량완성시 행어, 보강형 등의 고정하중을 지지하여 가설완료시 형상과는 차이가 발생한다. 따라서, 주케이블의 가설완료시 형상이 교량완성시 형상에 직접적인 영향을 미치므로 가설중 형상관리가 매우 중요하다. 주케이블의 가설중 형상관리는 중앙 및 측경간은 새그조정으로, 정착경간은 장력조정으로 수행된다. 새그조정은 새그조절량에 대한 스트랜드 길이 조절량을 나타내는 산정값인 새그민감도가 필요하며 장력조정은 온도변화에 대한 장력변화량을 나타내는 장력민감도가 필요하다. 이에 본 연구에서는 케이블 형상가정에 따라 유도된 기본식과 이로부터 도출된 미분 관계식으로부터 새그 및 장력민감도를 산정하는 방법을 제안하였다. 그리고, 다양한 새그변화 요인에 대해 현수선 기본식을 사용한 비선형 수치해석 새그민감도 계산 흐름도를 제안하여 미분관계식을 적용한 새그민감도 결과와 비교하였다. 또한, 각 새그변화 요인이 복합적으로 발생함으로 이를 고려하여 케이블의 최종 새그변화량을 산정하는 방법을 제안하였다. PPWS 공법으로 시공중인 실교량을 대상으로 PPWS의 길이변화 및 온도변화, 경간장변화 등의 다양한 시공여건의 변화에 따른 새그 및 장력민감도를 산정하였다. 본 연구내용이 주케이블 가설중 형상관리 방법에 대한 체계적인 지침이 되기를 바라며, 향후 실교 현장적용 및 실증에 의해 완성도를 높일 것이다.

화재모델 CFAST를 이용한 원전 화재구역의 CCDP평가 (CCDP Evaluation of the Eire Area of NPPs Using Eire Model CEAST)

  • 이윤환;양준언;김종훈;노삼규
    • 한국화재소방학회논문지
    • /
    • 제18권4호
    • /
    • pp.64-71
    • /
    • 2004
  • 본 논문에서는 NIST에서 개발한 CFAST 화재 모델링 코드를 사용하여 원자력발전소 펌프실 화재를 모의하였다. 급기 제한, 최소 산소 농도(Lower Oxygen Limit), 복사열 방출비율(Radiative Fraction), 방화문 개방 정도 등의 CFAST 입력 변수 변화에 따라 화재 성장 변화를 분석하였다. 분석 결과에 의하면 본 화재구역에서의 화재는 환기 지배형 화재이므로 급기 제한 및 최소 산소 농도 10%로 설정하는 것이 타당한 것으로 판단되며, 복사열 방출에 따라 상부층 가스 온도는 큰 변화가 없는 것을 알 수 있었다. 화재가 발생한 화재구역 내 펌프를 제외하고는 상부에 위치한 케이블은 모두 건전성을 유지하는 것으로 나타났으며, CCDP(Conditional CDP)를 평가한 결과 9.25E-07로, 화재위험도분석보다 현실적이고 불확실성이 감소한 결과를 도출할 수 있었다.

화재모델 CFAST를 이용한 원전 화재구역의 CCDP평가(II) (CCDP Evaluation of the Eire Areas in NPP Applying CEAST Model (II))

  • 이윤환;양준언;김종훈;김운형
    • 한국화재소방학회논문지
    • /
    • 제19권3호
    • /
    • pp.20-27
    • /
    • 2005
  • 본 논문에서는 화재 모델 CFAST를 사용하여 원자력발전소에 있는 8개 펌프실의 화재 안전 수준을 평가해 보고, 그 결과를 조건부 노심손상확률에 반영하여 분석해 보았다. 분석 대상 구역은 원자력발전소 일차보조건물에 위치한 고압안전주입 펌프실 A/B,저압안전주입 펌프실 A/B, 격납건물 살수 펌프실 A/B 및 모터구동 보조급수 펌프실 A/B 총 8곳이었다. 각 화재구역의 상부층 가스 온도를 분석하였으며, 분석 결과를 바탕으로 상부층에 위치한 케이블의 손상 유무를 파악하였다. 분석 결과에 의하면 총 8개 화재구역의 상부층 케이블은 건전성을 유지하는 것으로 확인되었다. 케이블의 건전성 평가 결과를 바탕으로 각 화재구역의 조건부 노심손상확률을 평가한 결과, 기존의 보수적인 가정 하에 수행된 화재위험도분석 결과보다 약 2배정도 감소하는 보다 현실적이고 불확실성이 감소한 결과를 도출할 수 있었다.

GNSS 원격 무결성 감시시스템 개발 (Development of Remote Integrity Monitoring System for GNSS)

  • 배중원;송재훈;전향식;남기욱;이한성
    • 항공우주기술
    • /
    • 제5권2호
    • /
    • pp.16-26
    • /
    • 2006
  • 위성항법시스템(GNSS)을 민간항공 분야에 활용하기 위해서는 국제민간항공기구가 정한 비행단계별 정확성(Accuracy), 무결성(integrity), 연속성(continuity), 가용성(availability) 요 구조건을 만족시켜야 한다. 본 논문에서는 GBAS, GRAS 등 지상기반 위성항법보강시스템 개발에 활용될 수 있는 CNSS 원격 무결성 감시시스템을 제안하고 개발결과에 대해 기술한다. GPS 수신기와 안테나로 구성된 위성신호 수신장치는 RS-232 to TC/IP 프로토콜 변환장치를 통해 데이터 처리 및 분석을 수행하는 신호처리장치의 Host PC에 연결되도록 설계되었다. 이는 GPS 수신기의 설치 위치 제한을 극복하고 수신기와 안테나 간의 물리적 거리를 줄일 수 있어 GPS 수신 신호의 열화를 방지할 수 있는 방법이다. GPS 데이터를 수신하여 처리하는 신호처리장치는 실시간 운용 및 후처리 운용이 가능하며 GBAS CAT-I급의 무결성 알고리즘과 차분보정 정보 생성을 지원하는 개발 환경을 제공한다.

  • PDF

USB 케이블의 전원선 에서의 방사성 EMI 개선 (The Reduction Method for Radiated EMI in USB Power Line of Cable)

  • 박경진;이대우;고영목;강은균;박종현;김근용;나극환
    • 전자공학회논문지
    • /
    • 제50권9호
    • /
    • pp.201-208
    • /
    • 2013
  • 본 논문에서는 USB(Universal Serial Bus) 케이블 전원선에서의 방사성 EMI(Electro-Magnetci Interference) 개선 방안을 제시한다. 케이블 전원선에서의 EMI 방사현상을 확인하기 위해 무선 비디오 액세스 시스템을 이용하여, 방사성 EMI 결과를 분석하고 초기 측정 결과 규제치 대비 약 3 [dBuV/m]~15 [dBuV/m]를 초과함을 확인한다. 방사성 EMI 원인 분석을 위해, 먼저 USB 케이블 전원선에서의 S-파라미터 측정을 수행하여 케이블의 고주파수 대역에서의 규칙적인 공진현상과 방사성 EMI 주파수의 연관성을 분석한다. 그리고, 전원 회로 임피던스 관리 기법을 응용하여 캐패시터의 개수 선정, 비드를 이용한 저역통과 대역 필터를 구성을 통해 케이블 전원선의 공진현상을 저감하는 개선방법을 적용한다. 결론적으로 개선된 회로를 시스템에 적용하여 케이블의 규칙적 공진의 저감방법을 제시하여, 방사성 EMI 테스트 결과 규제치 대비 약 3 [dBuV/m]~20 [dBuV/m] 마진의 마진을 확보하여 제시한 방법의 적합성 확인한다.

Structural health monitoring data reconstruction of a concrete cable-stayed bridge based on wavelet multi-resolution analysis and support vector machine

  • Ye, X.W.;Su, Y.H.;Xi, P.S.;Liu, H.
    • Computers and Concrete
    • /
    • 제20권5호
    • /
    • pp.555-562
    • /
    • 2017
  • The accuracy and integrity of stress data acquired by bridge heath monitoring system is of significant importance for bridge safety assessment. However, the missing and abnormal data are inevitably existed in a realistic monitoring system. This paper presents a data reconstruction approach for bridge heath monitoring based on the wavelet multi-resolution analysis and support vector machine (SVM). The proposed method has been applied for data imputation based on the recorded data by the structural health monitoring (SHM) system instrumented on a prestressed concrete cable-stayed bridge. The effectiveness and accuracy of the proposed wavelet-based SVM prediction method is examined by comparing with the traditional autoregression moving average (ARMA) method and SVM prediction method without wavelet multi-resolution analysis in accordance with the prediction errors. The data reconstruction analysis based on 5-day and 1-day continuous stress history data with obvious preternatural signals is performed to examine the effect of sample size on the accuracy of data reconstruction. The results indicate that the proposed data reconstruction approach based on wavelet multi-resolution analysis and SVM is an effective tool for missing data imputation or preternatural signal replacement, which can serve as a solid foundation for the purpose of accurately evaluating the safety of bridge structures.

수직전력구 내진설계를 위한 응답변위 산정에 대한 사례 조사 (Case Study of Estimate the Response Displacement for the Seismic Design of Shaft Cable Tunnel)

  • 김용민;정상섬;김영호;권영기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.634-639
    • /
    • 2009
  • The response displacement method is the most frequently used method for the seismic design of underground structures. Underground structures under seismic loading will tend to deform with the surrounding ground, and thus the structure is designed to accommodate the free-field deformation without loss of its structural integrity. This method is pseudo-static method, and response displacement of surrounding ground are most important steps. In this study, the single cosine method and the equivalent linear analysis are applied to estimate the response displacement of the real sites, and the results of the each method are compared. Response analysis was also performed with respect to bedrock depth. As a results, Equivalent linear analysis result was larger than single cosine method. And, the relative displacement becomes lager according to depth of the bedrock.

  • PDF

고정 방식 차이에 따른 배전 가공전선의 고주기피로 수명 특성 비교 평가 (Clamp Type-dependent HCF Life Estimation of the Overhead Cable for Distribution Grids)

  • 이두영;정진성;김영대;방지예
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권2호
    • /
    • pp.241-248
    • /
    • 2021
  • High cycle fatigue life for the cables with two different types of clamps is estimated comparatively through acceleration testing. The high cycle fatigue fracture of overhead lines is caused mainly by the aeolian vibration which is induced by vortex shedding. It is necessary to manage the integrity of cables continuedly considering that the aeolian vibration is unavoidable since it occurs in steady and relatively low wind velocity. Two types of clamps which are largely used for overhead lines of the distribution grids are selected and failure data are obtained by step stress testing with a electrodynamic shaker with them. The inverse power law is assumed to describe the stress-life relationship and the fatigue limit at any specified life is supposed to follow Weibull distribution. The life of the cable is defined as the number of cycles to the time that one of strands is completely broken. Finally, the fatigue limits of the cables with two clamp types are estimated at the reference life of 500 Mcycles and compared each other based on a bending vibration amplitude.

현수교 행어케이블의 장력 추정을 위한 직접탐색법 기반의 역해석 기법의 적용 (Application of Back Analysis Technique Based on Direct Search Method to Estimate Tension of Suspension Bridge Hanger Cable )

  • 김진수;박재봉;박광림;박동욱;김성완
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권5호
    • /
    • pp.120-129
    • /
    • 2023
  • 행어케이블의 장력은 현수교의 건전성과 안전성을 확인할 수 있는 주요 응답 중 하나이다. 일반적으로 공용 중인 현수교에서 행어케이블의 장력을 추정하기 위해 진동법이 주로 사용되고 있다. 진동법은 행어케이블에서 고유진동수들을 측정하고 행어케이블의 형상 조건을 이용하여 간접적으로 장력을 추정하는 방법이다. 이 연구에서는 영상계측시스템을 이용하여 팔영대교의 행어케이블에 대하여 장력을 추정하였다. 영상계측시스템은 측정의 편의성과 경제성을 고려하여 디지털 캠코더와 삼각대를 사용하였다. 영상계측시스템을 이용하여 측정된 행어케이블의 응답은 변위 기반이므로 진동법을 적용하기 위한 고차모드의 고유진동수는 측정하기 어려울 수 있다. 이 연구에서는 저차모드의 고유 진동수를 이용하여 장력을 추정할 수 있는 역해석 기법을 적용하였다. 역해석 기법은 현장에서 측정된 행어케이블의 고유진동수들과 유한요소해석을 이용하여 산정된 고유진동수들의 오차를 목적함수로 정의하여 최적화를 수행하였다. 최적화 방법은 목적함수의 편미분이 필요 없는 직접탐색법을 적용하였다. 역해석 기법을 이용하여 산정된 장력과 진동법을 이용하여 추정된 장력을 비교 분석하여 역해석 기법에 대한 신뢰도와 정확도를 확인하였다. 그 결과 역해석 기법을 적용하면 저차모드의 고유진동수를 이용하여도 신뢰성 있는 장력의 추정이 가능하였다.