• Title/Summary/Keyword: CW(Continuous Wave)

Search Result 153, Processing Time 0.021 seconds

Heart beat and Respiration Detection Performance of CW radar Based on New Signal Model (새로운 신호모델에 의한 CW 레이다 심장박동 및 호흡검출 성능분석)

  • Lee, Byung-Seub
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.1
    • /
    • pp.28-33
    • /
    • 2017
  • In this paper, new signal model for bio-signal detection, i.e heart beat and respiration, using CW radar. Most research on this similar topic are based on the conventional signal model which is not correct in envisaging reflected signal from the human body. The system developed based on this conventional model can not predict exact performance of the system. So in this paper modified signal model for bio-radar is proposed and then simulation for detecting heartbeat and respiration signal in AWGN, multipath environment. The detection performance difference between two signal models are discussed.the modified

Phase Noise Characterization with Optical Carrier Suppression Level on Continuous Wave in the Ranges of Millimeter Waves Generated by Photomixing of Optical Double Sideband-Suppressed Carrier(DSB-SC) (광 반송파가 억압된 양측 대역 방식의 광 혼합을 통하여 발생된 밀리미터파 대역 연속파에서 광 반송파 억압 레벨에 따른 위상 잡음 특성 분석)

  • Kim, Sung-Il;Kang, Kwang-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.974-982
    • /
    • 2009
  • Photomixing techniques beating two optical signals with different wavelengths and strong correlations are also very useful techniques to make a continuous wave(CW) signals in the range of millimeter(mm) and terahertz(THz) frequencies. An optical double sideband-suppressed carrier(DSB-SC) technique is one of the popular techniques to generate two optical signals with different wavelengths and strong correlations. DSB-SC signals with strong correlations are generated by a CW modulation of an optical carrier with a local oscillator and an optical modulator. In the previous parers related the DSB-SC for producing the CW signals within the range of mm and THz frequencies, there have been no reports why the optical carrier should suppress. In order to clear that, we have analyzed and measured the characteristics of the mm-wave CW signals made by the DSB-SC photomixing in this paper. From our analysis and measurement results, compared with the case of the DSB with the maximized optical carrier, the power and phase noise have improved about 23.9 dB and 21 dBc/Hz(@ 1 MHz offset frequency) in the case of the DSB with the minimized optical carrier (that is to say, the DSB-SC). Consequently, it is evident reason that the optical carrier should sufficiently suppress to obtain the mm-wave CW signals with the high power and low noise. This paper has given very helpful data to make mm- and THz-wave CW signals using photomixing techniques with the DSB-SC because the reason why the optical carrier should be suppressed is reported in this paper based on the numerical and experimental results.

Imaging Technique Based on Continuous Terahertz Waves for Nondestructive Inspection (비파괴검사를 위한 연속형 테라헤르츠 파 기반의 영상화 기술)

  • Oh, Gyung-Hwan;Kim, Hak-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.328-334
    • /
    • 2018
  • The paper reviews an improved continuous-wave (CW) terahertz (THz) imaging system developed for nondestructive inspection, such as CW-THz quasi-time-domain spectroscopy (QTDS) and interferometry. First, a comparison between CW and pulsed THz imaging systems is reported. The CW-THz imaging system is a simple, fast, compact, and relatively low-cost system. However, it only provides intensity data, without depth and frequency- or time-domain information. The pulsed THz imaging system yields a broader range of information, but it is expensive because of the femtosecond laser. Recently, to overcome the drawbacks of CW-THz imaging systems, many studies have been conducted, including a study on the QTDS system. In this system, an optical delay line is added to the optical arm leading to the detector. Another system studied is a CW-THz interferometric imaging system, which combines the CW-THz imaging system and far-infrared interferometer system. These systems commonly obtain depth information despite the CW-THz system. Reportedly, these systems can be successfully applied to fields where pulsed THz is used. Lastly, the applicability of these systems for nondestructive inspection was confirmed.

Enhancement of IPDR of SOA-MZI Wavelength Converter with Pre-amplifier Using a CW-HB (CW-HB를 이용하는 전치증폭기를 가진 SOA-MZI 파장변환기에서 IPDR 개선)

  • Kim Joo-Youp;Han Sang-Kook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.1A
    • /
    • pp.11-15
    • /
    • 2006
  • A pre-amplified semiconductor optical amplifier-Mach-Zehnder interferometer(SOA-MZI) wavelength converter (WC) using a continuous wave-holding beam(CW-HB) is proposed and experimentally demonstrated at 10Gb/s. The proposed scheme achieves not only enhancement of input power dynamic range(IPDR) to over 20dB but also higher Q parameter of about 2 to 3 by no output signal distortion and higher extinction ratio(ER) of about 2dB to 5dB by low noise figure (NF), compared with the bias current control method.

Performance of Continuous-wave Coherent Doppler Lidar for Wind Measurement

  • Jiang, Shan;Sun, Dongsong;Han, Yuli;Han, Fei;Zhou, Anran;Zheng, Jun
    • Current Optics and Photonics
    • /
    • v.3 no.5
    • /
    • pp.466-472
    • /
    • 2019
  • A system for continuous-wave coherent Doppler lidar (CW lidar), made up of all-fiber structures and a coaxial transmission telescope, was set up for wind measurement in Hefei (31.84 N, 117.27 E), Anhui province of China. The lidar uses a fiber laser as a light source at a wavelength of $1.55{\mu}m$, and focuses the laser beam on a location 80 m away from the telescope. Using the CW lidar, radial wind measurement was carried out. Subsequently, the spectra of the atmospheric backscattered signal were analyzed. We tested the noise and obtained the lower limit of wind velocity as 0.721 m/s, through the Rayleigh criterion. According to the number of Doppler peaks in the radial wind spectrum, a classification retrieval algorithm (CRA) combining a Gaussian fitting algorithm and a spectral centroid algorithm is designed to estimate wind velocity. Compared to calibrated pulsed coherent wind lidar, the correlation coefficient for the wind velocity is 0.979, with a standard deviation of 0.103 m/s. The results show that CW lidar offers satisfactory performance and the potential for application in wind measurement.

Improvement of Phase Noise Characteristics of Continuous Wave in the Sub-Millimeter Bands Generated by Photomixing Using Polarization and Phase Mismatch (편광 및 위상 부정합을 이용한 광혼합을 통하여 발생된 서브 밀리미터파 대역 연속파의 위상 잡음 특성 개선)

  • Kim, Sung-Il;Kang, Kwang-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.617-626
    • /
    • 2010
  • In this paper, we have proposed and experimentally performed a polarization and phase control method of an optical signal which has same wavelength with the optical carrier to improve phase characteristics of a continuous wave(CW) generated by the double sideband-suppressed carrier(DSB-SC) as one of the famous photomixing technique for making sub-millimeter and terahertz waves. A polarization and phase controlled optical signal has been coupled with the general DSB-SC on an optical coupler. The output of the optical coupler is then photomixed by a photomixer. From our analysis and measurement results, we have found that the amplitude of the generated sub-mm and terahertz CW signal is higher 1.5 dB and the phase noise is lower about 3 dB@10 kHz offset frequency than the general DSBSC. Consequently, since our proposed method has improved the amplitude and phase noise of CW signals in the sub-mm and terahertz bands, it can be helpful results to make low cost CW generator in sub-millimeter and subterahertz bands.

A study on the development of CW(Continuous-Wave) Doppler System using FFT (FFT를 이용한 연속초음파 도플러 장치에 관한 연구)

  • Lee, Dae-Hyung;Kang, Chung-Shin;Park, Sei-Hyun;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.709-712
    • /
    • 1988
  • Ultrasonic Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. CW(Continuous-Wave) Doppler System uses quadrature detection and phase rotation method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time-domain, had been fabricated. But time-domain analyzing such as audio evaluation and zero- crossing detection for instantaneous and mean frequnecy measurement do not provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency-domain technique to improve system performance. In this paper, we describe a unit which is composed of CW Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of Blood signal.

  • PDF

Optical Coherence Tomography Based on a Continuous-wave Supercontinuum Seeded by Erbium-doped Fiber's Amplified Spontaneous Emission

  • Lee, Ju-Han;Jung, Eun-Joo;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.49-54
    • /
    • 2010
  • In this study, the use of a continuous-wave (CW) supercontinuum (SC) seeded by an erbium-doped fiber's amplified spontaneous emission (ASE) for optical-coherence tomography imaging is experimentally demonstrated. It was shown, by taking an in-depth image of a human tooth sample, that due to the smooth, flat spectrum and long-term stability of the proposed CW SC, it can be readily applied to the spectral-domain optical-coherence tomography system. The relative-intensity noise level and spectral bandwidth of the CW SC are also experimentally analyzed as a function of the ASE beam power.

Noise Cancellation and Detection of Heartbeat using A New Adaptive Noise Canceller Based on ALE(Adaptive Line Enhancer) in the CW Bio-radar (CW 바이오 레이더에서 ALE(Adaptive Line Enhancer) 기반의 새로운 적응형 잡음제거기를 이용한 잡음제거 및 심장박동 검출)

  • Seo, Myung-Hwan;Kim, Jae-Joong
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.4
    • /
    • pp.482-489
    • /
    • 2009
  • This paper proposes a CW(Continuous-Wave) bio-radar applying a new adaptive noise canceller based on ALE(Adaptive Line Enhancer) which can remove the Gaussian noise and system noise. Recently the research works on this CW bio-radar which can be used to detect heartbeat and respiration are advanced by the university and research facility. Although the researches describe CW bio-radar not only is vulnerable for the Gaussian noise but also has a disadvantage of decreasing the heart-rate accuracy due to the noise, the researches do not demonstrate the effective method for removing the noise component in a baseband signal. In this paper, a CW bio-radar applying the new adaptive noise canceller based on ALE which can remove the noise component is proposed. This paper compares and analyzes the performance for increasing the heart-rate accuracy according to removing the Gaussian noise and system noise in the baseband signal through the quadrature receiver which can alleviate the demodulation sensitivity to target position.

  • PDF

Position Estimation of Underwater Acoustic Source Using Pulsed CW Signal (Pulsed CW 신호를 사용하는 수중 음원의 위치 추정을 위한 시간지연차 추정법)

  • 최영근;손권;도경철;김기만
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.7
    • /
    • pp.514-520
    • /
    • 2004
  • There are many techniques for underwater source localization. These are the methods based on TDOA (Time Difference Of Arrival) estimation. beamforming techniques and high resolution techniques, etc. In this Paper we estimate the underwater source position using MCPSP (Modified Cross Power Spectrum Phase) function that is calculated on frequency domain using sensors of small number. However, the performances of the localizing method based on MCPSP function drops greatly in the case of CW (Continuous Wave) signal . In this Paper we proposed the TDOA estimation method for pulsed CW signal. In the Proposed method we composed of new segment including a edge of ping. This segment was computed by short-time energy detection. With theoretical representation the performances of the proposed method were analyzed under various environment.