• Title/Summary/Keyword: CV characteristics

Search Result 486, Processing Time 0.026 seconds

Quantitative Research Using Modified Digital Algometer according to Digestive Condition and Discomfort in Healthy Adults (건강한 성인의 소화 상태 및 소화 불편에 따른 복진용 압통장치를 활용한 정량적 연구)

  • Dae-Hyeok Kim;Young-Eun Kim;Sanghun Lee;Jeong Hwan Park
    • Korean Journal of Acupuncture
    • /
    • v.40 no.3
    • /
    • pp.99-108
    • /
    • 2023
  • Objectives : The aim of this study was to assess the quantitative characteristics of pressure pain threshold (PPT) and pressure depth (PD) at the abdominal conception vessel (CV) acupoints according to subjective digestive status and digestive discomfort levels, accomplished by comparing a large group of healthy men and women, using the modified digital algometer. Methods : A total of 1,504 healthy adults aged 19 years or older participated in this study. A questionnaire was administered to evaluate participants' digestive status and discomfort. PPT (kgf/cm2/s) and PD (mm) measurements were obtained at CV14, CV12, and CV4 acupoints using a modified digital algometer. General characteristics were analyzed using the chi-square test, and differences in PPT and PD were assessed using two-sample t-tests and ANCOVA. Results : Significant difference in PPT was found based on digestive status at CV14 and CV12 for both sexes, and in PD at CV14 for women. Women exhibited significant difference in PPT based on digestive discomfort at CV14, CV12, and CV4, while men showed significant difference at CV14 and CV12. Significant difference in PD was observed at CV14 and CV4 among women. Even after adjusting for age and body mass index, significant difference persisted in PPT based on digestive discomfort at CV14 and CV12 for both sexes. PD exhibited significant differences at CV14, CV12, and CV4 among women. Conclusions : Using the modified digital algometer, this study showed the significant difference of pressure pain threshold at the CV14 and CV12 acupoints for subjective digestive discomfort levels in healthy men and women.

Residual Insulation characteristics of long-term serviced 6.6 kV CV Cable (6.6kV 철거 CV 케이블의 잔존 절연 특성)

  • 백주흠;김동욱;한기만
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.46-49
    • /
    • 1994
  • In order to investigate possibility of CV cable diagnosis technique, residual insulation characteristics of .long - term serviced 0.6 kV CV Cable are examined by DC leakage current residual voltage tensile strength, cross1inking density and AC & impulse breakdown. Also effect of cable structure and water tree are reported

  • PDF

The Statistical Design of CV Control Charts for the Gamma Distribution Processes (감마분포 공정을 위한 변동계수 관리도의 통계적 설계)

  • Lee, Dong-Won;Paik, Jae-Won;Kang, Chang-Wook
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.29 no.2
    • /
    • pp.97-103
    • /
    • 2006
  • Recently, the control chart is developed for monitoring processes with normal short production runs by the coefficient of variation(CV) characteristic for a normal distribution. This control chart does not work well in non-normal short production runs. And most of industrial processes are known to follow the non-normal distribution. Therefore, the control chart is required to be developed for monitoring the processes with non-normal short production runs by the CV characteristics for a non-normal distribution. In this paper, we suggest the control chart for monitoring the processes with a gamma short runs by the CV characteristics for a gamma distribution. This control chart is denoted by the gamma CV control chart. Futhermore evaluated the performance of the gamma CV control chart by average run length(ARL).

The Correlation between Stem Characteristics and Its Resistance to Hail Damage in Potato Cultivars (우박저항성과 관련된 감자품종의 줄기 특성)

  • Jin, Yong-Ik;Chang, Dong-Chil;Cho, Ji-Hong;Cho, Kwang-Soo;Im, Ju-Sung;Hong, Su-Young;Kim, Su-Jeong;Sohn, Whang-Bae;Manjulatha, Mekapogu;Park, Kyeong-Hun;Kim, Yul-Ho;Yoo, Hong-Seob;Jeong, Jin-Cheol;Chung, Ill-Min
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.4
    • /
    • pp.321-326
    • /
    • 2014
  • BACKGROUND: Recently, weather disasters such as hail and typhoon occur frequently. These threaten the stable cultivation of potatoes. It is very important to cultivate potatoes with stable under unexpected weather disasters. This study was performed to investigate the correlation between mophological characteristics of potato stem and its resistance to hail damage in different potato cultivars. METHODS AND RESULTS: Hail fall occurred for 8 minutes on May 31, 2012 in the field of Highland Agriculture Research Center located in Jinbu-myeon Gangwon-do. Potato crop grown in the field was affected by hail due to which the stems of potato were broken. The percentage of broken stem of potato was investigated as the level of damage by hail. To determine the difference in the ratio of broken stem among the potato cultivars, physical characteristics of potato stem such as diameter and hardness were measured. To evaluate recovery phase after hail damage, ground coverage and yield were measured. The percentage of broken stem of cv. Goun and cv. Saebong were 30%, 26%, respectively, whereas it was 5% in the cv. Atlantic. Damage by hail was the lowest in cv. Atlantic. Diameter of the stem was 15 mm in cv. Atlantic, 13 mm in cv. Goun and 11 mm in cv. Saebong. The hardness of potato cultivars was measured which was 74 N in cv. Atlantic. 71 N in cv. Goun and 59 N in cv. Saebong. The ground coverage in cv. Atlantic was 79%, which was the highest followed by 73% in cv. Saebong and 56% in cv. Goun. The yield of cv. Atlantic was monitored at 90 days after planting which was 40 MT/ha and that of cv. Saebong was 36 MT/ha, whereas in cv. Goun, it was 30 MT/ha which was the lowest. CONCLUSION: The ratio of broken stem in cv. Atlantic was the lowest compared to cultivars. In the physical characteristics of stem, cv. Atlantic was the highest in value of diameter and hardness. Based on these results, it was considered that cv. Atlantic was resistant to hail damage compared to other cultivars.

AC Breakdown Characteristics for 22.9kV CV Power Cable Before and After Cyclic Aging for 14days (22.9kV CV 전력케이블의 14주기 고온 열화에 대한 교류파괴특성)

  • 윤대혁;김위영;박민호;박태곤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.601-604
    • /
    • 2001
  • 22.9 kV CV power cable is very important factor of underground distribution power line. Cyclic aging for 14days is performed to remove a large amount of the volatiles found in freshly manufactured cable. In this paper, we examined AC breakdown characteristics of CV power cable before and after cyclic aging for 14days. As the result, even if there were some exceptions, the AC breakdown voltage before aging was lower than that after aging, but most of the results were that the AC breakdown voltage after aging was lower than that before aging.

  • PDF

A Study on the Solidification Characteristics of CV Graphite Cast Iron (CV흑연주철(黑鉛鑄鐵)의 응고특성(凝固特性)에 관한 연구(硏究))

  • Chun, C.C.;Kim, S.Y.;Lee, G.W.
    • Journal of Korea Foundry Society
    • /
    • v.5 no.3
    • /
    • pp.5-12
    • /
    • 1985
  • Many researchers have studied the eutectic solidification of CV Graphite Cast Iron qualitatively. However quantative studies have not been done. The type of eutectic solidification of CV Graphite Cast Iron treated with CG Alloy (Fe-Si-Mg-5Ti-Ca-Ce) was studied quantitatively through M.D.E. value (Mushy Degree of Eutectic Solidification) = $t_2/t_1)$, where $t_1$ is the difference of the eutectic solidification starting time between surface and center part of the casting sample, and $t_2$ is the time of eutectic solidification of the center part. Following results were obtained. (1) The M.D.E. value of CV graphite cast iron lies between that of spheroidal graphite and that of flake graphite cast iron but is closer to that of Flake graphite cast iron. (2) The M.D.E. value of CV graphite cast iron depends upon CV ratio. (3) The time required for eutectic solidification increases as graphite form is changed from Flake, CV. to spheroidal graphite. (4) The M.D.E. value increases as cooling rate increases.

  • PDF

MEASUREMENT AND CHARACTERIZATION OF FRICTION IN AUTOMOTIVE DRIVESHAFT JOINTS

  • Lee, C.H.
    • International Journal of Automotive Technology
    • /
    • v.8 no.6
    • /
    • pp.723-730
    • /
    • 2007
  • The typical design of automotive driveshafts generally utilizes Constant Velocity(CV) joints as a solution to NVH. CV joints are an integral part of vehicles and significantly affect steering, suspension, and vehicle vibration comfort levels. Thus, CV joints have been favored over universal joints due to the constant velocity torque transfer and plunging capability. Although CV joints are common in vehicle applications, current research works on modeling CV joint friction and assumes constant empirical friction coefficient values. However, such models are long known to be inaccurate, especially under dynamic conditions, which is the case for CV joints. In this paper, an instrumented advanced CV joint friction apparatus was developed to measure the internal friction behavior of CV joints using actual tripod-type joint assemblies. The setup is capable of measuring key performance of friction under different realistic operating conditions of oscillatory speeds, torque and joint installation angles. The apparatus incorporates a custom-installed triaxial force sensor inside of the joint to measure the internal CV joint forces(including friction). Using the designed test setup, the intrinsic interfacial parameters of CV joints were investigated in order to understand their contact and friction mechanisms. The results provide a better understanding of CV joint friction characteristics in developing improved automotive driveshafts.

Disk Shape Design of Liquid Hydrogen Needle Valve with Various Inherent Flow Characteristics (다양한 고유유량 특성을 갖는 액체수소용 니들밸브의 디스크 형상 설계)

  • NAGYUMI HWANG;HYOLIM KANG;JUNGHO KANG;SEUNGHO HAN
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.4
    • /
    • pp.363-369
    • /
    • 2024
  • Needle valves are instrumentation devices with quick-opening inherent flow characteristics, used in pipelines requiring rapid flow supply immediately upon opening the flow path. For needle valves applied in liquefied hydrogen plants operating in cryogenic environments, it is necessary from the initial design stage to have various inherent flow characteristics in addition to quick-opening, depending on the intended usage. In this study, the inherent flow characteristics of a 1/2'' liquid hydrogen needle valve were evaluated through computational fluid dynamics analysis. Disk shapes exhibiting various inherent flow characteristics were proposed by deriving the flow coefficient (Cv) according to changes in disk shapes. Among the disk shapes that directly affect the Cv, the disk length and slope angle were selected, and case studies were conducted with nine parameter combinations. From the results of the normalized Cv regarding to opening rates, disk lengths and slope angles exhibiting quick-opening, equal-percentage, and linear inherent flow characteristics were determined.

A Study on CV12 Moxibustion of King Sukjong(肅宗) of Joseon Dynasty -Focusing on Seungjeongwon Ilki(承政院日記) Yakbang(藥房) Records - (숙종(肅宗)의 중완혈(中脘穴) 수구사(受灸事) 연구 - 『승정원일기』 약방기록을 중심으로 -)

  • Kim, Dongryul;Ko, Daewon;Kim, Hyunkyung;Cha, Wungseok;Ahn, Sangwoo
    • Journal of Korean Medical classics
    • /
    • v.28 no.4
    • /
    • pp.121-137
    • /
    • 2015
  • Objectives : To investigate the progress, characteristics, and reasons of CV12 moxibustion that King Sukjong of Joseon Dynasty had experienced 31 years since 1684. Methods : This study mainly extracted the records and related records about CV12 moxibustion of King Sukjong and relevant records from Seungjeongwon Ilgi, and analyzed them. Aside from that, medical books wrote at that time and relevant records were additionally investigated. Results : King Sukjong cauterized CV12 or other CV12 related acupoints with moxa 21 years out of his 31 years from 1684 to 1714. The cautery period was usually between late January and mid February. He had 100 pieces of moxa for cautery. On the last day of his moxibustion, he cauterized ST36 with moxa. The moxibustion process consisted of the following steps: suggestion or requirement of moxibustion, decision of date and time, and moxa cautery. In 1684, the reason why King Sukjong cauterized CV12 with moxa was to treat his joint pain and nauseous symptoms. The effect can be found in Donguibogam, many other Korean medical books, and other general books at that time. In 1685, he began to cauterize CV12 with moxa to prevent diseases. Since then, most moxa cautery on CV12 had been performed in the same context. Conclusions : For 21 years, King Sukjong repeatedly cauterized CV12 with moxa. The moxa therapy was conducted to prevent diseases mostly. And King Sukjong had a lot of interest in the therapy. For the reasons, the therapy had repeatedly been performed so long.

PE Header Characteristics Analysis Technique for Malware Detection (악성프로그램 탐지를 위한 PE헤더 특성 분석 기술)

  • Choi, Yang-Seo;Kim, Ik-Kyun;Oh, Jin-Tae;Ryu, Jae-Cheol
    • Convergence Security Journal
    • /
    • v.8 no.2
    • /
    • pp.63-70
    • /
    • 2008
  • In order not to make the malwares be easily analyzed, the hackers apply various anti-reversing and obfuscation techniques to the malwares. However, as the more anti-revering techniques are applied to the malwares the more abnormal characteristics in the PE file's header which are not shown in the normal PE file, could be observed. In this letter, a new malware detection technique is proposed based on this observation. For the malware detection, we define the Characteristics Vector(CV) which can represent the characteristics of a PE file's header. In the learning phase, we calculate the average CV(ACV) of malwares(ACVM) and normal files(ACVN). To detect the malwares we calculate the 2 Weighted Euclidean Distances(WEDs) from a file's CV to ACVs and they are used to decide whether the file is a malware or not. The proposed technique is very fast and detection rate is fairly high, so it could be applied to the network based attack detection and prevention devices. Moreover, this technique is could be used to detect the unknown malwares because it does not utilize a signature but the malware's characteristics.

  • PDF