• 제목/요약/키워드: CV Cable

검색결과 63건 처리시간 0.031초

지중배전케이블 외피용 컴파운드의 이온투과 특성 비교 (Effect of Ionic Impurities in Materials for CN/CV Underground Distribution Power Cable Jackets)

  • 김동명;권태호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.167-168
    • /
    • 2008
  • The permeation of $Ca^{2+}$ ions through the materials such as polyvinyl chloride (PVC) and non-halogenated flame retardant cross linked polyolefin (FR-XLPO) used for CN-CV underground distribution power cable jackets was investigated. The permeation of $Ca^{2+}$ ions was found to increase with the increase of time. The FR-XLPO showed higher permeation of $Ca^{2+}$ ions, by a factor of about two, than the PVC. This was explained by the destruction of structural integrity caused by mixing a large amount of mineral flame retardant such as $Mg(OH)_2$ used to impart non-flame ability to the jacket material.

  • PDF

전극형상에 의한 초고압 CV케이블 절연체의 부분방전 특성 (Partial Discharge Characteristics of Ultra-High Voltage CV Cable Insulators by Electrode Shape)

  • 김규식;김병현;정현기;차광석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.712-717
    • /
    • 2005
  • In this thesis, it is investigated that the effect of the cross linked polyethylene(XLPE) insulator do to breakdown phenomenon by the insertion of the needle and bar electrode into XLPE which is used of electric power cable for the ultra-high voltage. The result of the partial discharge properties in the specimen showed that in case of the insertion of needle or bar electrode into XLPE, the effect of the inner discharge become large when the air void is bigger then the clearance of the electrode of the specimen. The closer the distance between the insulator and needle electrode, it takes less time to the insulation breakdown.

  • PDF

6.6kV 케이블 사고분석 (The Accident Analysis of 6.6kV CV Cable)

  • 송길목;김영석;김향곤;최충석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.60-63
    • /
    • 2005
  • In this paper, the accidents of 6.6kV CV cable using many analysis methods such as a pattern anlysis were analyzed; the inner structure analysis; cross section analysis; SEM; EDX, etc. With the analysis and the accident reconstruction, It was possible to analyze the accident causes. For more correct assessment, another accident reconstruction and simulation with a software were required.

  • PDF

S-Z 중성선 전력 케이블의 개발 (DEVELOPMENT OF S-Z STRANDED NEUTRAL POWER CABLE)

  • 김종원;백흠수;최영훈;최명규;김선국;김종찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1296-1298
    • /
    • 1995
  • This paper presents the power cable with the concentric neutral wires of S-Z stranding. This type Cables, 22.9KV CN/CV Cables used in the distribution systems have been developed in order to improve bend, bend after torsion and tension charateristics. We have designed and made S-Z stranding machine, testing equipment etc., and have established the manufacturing technology of the equipment and the testing technology.

  • PDF

기계적 손상에 따른 6.6kV케이블 종단부의 전기적 특성 (Electrical Properties of 6.6kV Cable Termination by Mechanical Damage)

  • 백승명;최진욱;김상현;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1299_1300
    • /
    • 2009
  • We show results that examine about electrical properties of XLPE insulated 6.6kV cable termination by mechanical damage. The cable used to produce the cable termination is 6/10kV tray XLPE fire retardant electric cable (6/10kV TFR-CV $35SQMM{\times}1C$) which is domestically made. We apply force to XLPE insulator and made mechanical defect using knife. Defected samples go through the withstand voltage test according to the IEEE std. 48 test regulations and lighting impulse (hereunder, IMP) withstand voltage test regulations. Then the effects of the scars shown during the construction process on electric accidents at the end part are analyzed.

  • PDF

컴퍽트형 고온 초전도 전력 케이블의 기대 효과와 경제성 평가 (Effect of compact HTS superconduction 7ower cable and evaluation of its economical efficiency)

  • 최상봉;성기철;조건욱;정성환;김대경;김학만;전영환
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권2호
    • /
    • pp.10-14
    • /
    • 2001
  • This paper presents the possible application of a HTS superconducting power cable fro transmitting electric power in metropolitan areas, reflecting its important distinction such as compactness for installation in underground ducts and considerable efficiency improvement comparable to present underground cables. In this paper, we investigated characteristic and market scale compact HTS transmission cable which is possible to install in under-ground ducts. and reviewed its economical efficiency comparing to present existed CV cable construction and duct or tunnel installation.

  • PDF

콤팩트형 고온 초전도 전력 케이블의 도입 효과와 경제성 검토 (Effect of compact HTS superconduction power cable and investigation of its economical efficiency)

  • 최상봉;성기철;조전욱;정성환;김대경
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.108-111
    • /
    • 2001
  • This paper presents the possible application of a HTS superconducting power cable for transmitting electric power in metropolitan areas, reflecting its important distinction such as compactness for installation in underground ducts and considerably economical efficiency comparable to present underground cables. In this paper, we investigated characteristic and market scale compact HTS transmission cable which is possible to install in underground ducts. And reviewed its economical efficiency comparing to present existed CV cable from point of view such as cost for cable construction and duct or tunnel installation.

  • PDF

충격파-부분방전(SI-PD) 시험방법을 이용한 케이블 진단에 관한 기초 연구 (A Possible diagnostic method of cable system using SI-PD measurement)

  • 김정태;구자윤;장은;조연옥;김상준;송일근;김주용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1774-1777
    • /
    • 1996
  • In this paper, applicability of SI-PD(switching impulse - partial discharge) testing method was put on an attempt as a newly proposed diagnostic method for the underground distribution power cable system in Korea. For this purpose, SI-PD testing equipment was designed, and tests were performed using artificial needle-type defects integrated into the 22.9 kV CN/CV cables in drder to prove its reliability. As a result, arc noises, generated from spark gap, were considerably decreased by use of a pneumatic switch immersed into oil, and artificial needle-type defects were well detected with impulse voltage level under $2U_0$. These results imply that it is likely possible to apply SI-PD measurement method as a the nondistructive test for the 22.9 kV CN/CV cable system in Korea.

  • PDF

다른 굵기의 6/10[kV]급 CV 케이블 직선접속부 안전성 평가 (A Safety Assessment of Splice of 6/10[kV] Class CV Cables with Different Conductor Size)

  • 정종욱;김선구;정진수
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.78-84
    • /
    • 2010
  • This paper describes the safety assessment of power cable splices connecting different sized 6/10[kV] class power cables. To assess the safety, AC withstand voltage tests, partial discharge tests and impulse tests were carried out to the cable splice specimens and thermal rise due to overload and cross section of joint were examined as well. As a result, a breakdown due to the $4.5[U_0](27[kV_{ac}])$ application could not found for 5 minutes. Under $1.73[U_0](10.4[kV_{ac}])$ application, partial discharges of 4~8[pC] were detected. In impulse tests, all the specimens withstood to the standard waveforms of $75[kV_{peak}](1.2{\times}50[{\mu}s])$ without any breakdowns. In addition, the temperature on the splice rose by $3[^{\circ}C]$ when the 200[A] flew through the splice for 20minutes, however the thermal rise of $3[^{\circ}C]$ was considered due to the atmospheric temperature. After all the electrical tests, the cross section of the splice was visually examined. The conditions of the conductors of both $185[mm^2]$ and $240[mm^2]$ were good.

초고압 XLPE 케이블용 프리몰드형 접속함 (Premolded Joint) 개발 (Development of single piece premolded joint for EHV XLPE cable system)

  • 신두성;최수걸;고의곤;지응서;민병관;강채홍;전승익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.410-412
    • /
    • 2001
  • 초고압 CV 케이블용으로 다양한 형태의 접속함이 사용되고 있으나, 최근 케이블 시스템의 사용 전압이 초고압화됨에 따라 접속함 또한 고품질, 고신뢰성이 요구되고 있다. 따라서 공장에서 엄격한 품질 관리가 용이하고, 현장에서 쉽게 조립할 수 있는 프리몰드형 접속함(Premolded Joint: PMJ)의 사용이 급격하게 증대되고 있다. 본 논문에서는 국내에서 최초로 $110kV{\sim}170kV$ 전압급의 PMJ 접속함 개발에 관하여 소개 하였다. 전기적, 기계적 및 열적 설계의 개념을 간략하게 소개하였으며, 접속함의 초기 성능 및 장기 신뢰성을 검증하기 위한 시험 및 평가 결과를 소개하였다.

  • PDF