• Title/Summary/Keyword: CV%

Search Result 3,697, Processing Time 0.029 seconds

The Relationship between Multi-cultural Family Father's Participation in their Children's Fostering and Children's Vocabulary (여성 결혼 이민자의 다문화 가정에서 아버지의 양육참여실태와 유아의 어휘력과의 관계)

  • Lee, Min-Kyung
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.11
    • /
    • pp.211-222
    • /
    • 2016
  • This study was to investigate 1) the effect of the variables (age, education level, average monthly income, occupation) relating to the multi-cultural family father(MF) on children's vocabulary(CV), 2) the relationship between the father's participation in their children's fostering(FPCF) and CV. FPCF in 24 MFs and CV were evaluated using the questionnaire, interview. The results are as follows: 1) There were significant correlations among father's education level, average income, occupation, and CV. FPCF scores. 2) There were no significant correlation between father's age and CV. 3) There were significant correlations between FPCF scores and CV. And some interview examples were illustrated in this paper.

Relationship between Sasang Constitution and Length of Chest and Abdominal Region (사상체질과 인체 흉복부길이와의 관계)

  • Ahn, Ji-Sun;Park, Sang-Kyun;Yu, Jun-Sang
    • Korean Journal of Acupuncture
    • /
    • v.30 no.2
    • /
    • pp.131-134
    • /
    • 2013
  • Objectives : This study was performed to investigate the relationship between Sasang Constitution and length of chest and abdomen region. Methods : Forty eight participants were enrolled. Weight, height, and lengths from CV22 to CV16, from CV16 to CV8, and from CV8 to CV2 were measured. Ratios of last three lengths to total CV22 to CV2 were calculated respectively. On the other hand, Sasang Constitution was analyzed with QSCCII(Questionnaire of Sasang Constitutional Classification II). The analysis of relationship between the measurements and Sasang Constitution was carried out with SPSS to compare the mean values according to Sasang Constitution. Results : All the mean values were not significantly different depending on the Sasang Constitution, except the ratio of the length from CV16 to CV8 to the length from CV22 to CV2, only in female participants. The ratio was higher in the female Soeumin participants than any other constitutional groups. Conclusions : This result showed that Soeumin could be assumed that they might have weak digestion abilities.

A Rye Cultivar "Charmgreen", Early-heading, High Forage Yield Potential, and Resistance to Stresses (조숙 다수 내재해성 호밀 품종 "참그린")

  • Ouk-Kyu Han;Dea-Wook Kim
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.44 no.1
    • /
    • pp.14-19
    • /
    • 2024
  • "Chamgreen" was a domestically developed rye (Secale cereal L.) cultivar in South Korea, known for its quick heading, cold resistance, and abundant yield of forage. The heading date of cv. 'Chamgreen' averaged April 17th, which was 4 days earlier than the standard cv. 'Gogu'. In the early harvesting stage, the plant height reached an average of 119 cm, 7 cm taller than the standard cv. 'Gogu', and the number of spikes per m2 was 865, slightly less than cv. 'Gogu's 897. Resistance to cold and powdery mildow remained consistent across four regions nationwide over three years, with an average rating of 0, matching cv. 'Gogu'. Lodging resistance was also rated at 2, equivalent to cv. 'Gogu'. The dry matter yield of cv. 'Chamgreen' was 9.1 tons per hectare, 15% higher than cv. 'Gogu's 7.9 tons. Although the protein content in cv. 'Chamgreen' was 13.5%, 1.6% lower than cv. 'Gogu', the total digestible nutrients (TDN) content was 5.81 tons per hectare, 20% higher than cv. 'Gogu'. Due to its strong cold resistance, cv. 'Chamgreen' allows for winter cultivation through double cropping and rotation systems in various regions across the country.

The Study of Abdominal Temperature of Leukorrhea patients using DITI (DITI를 이용한 대하증을 호소하는 환자의 복부 온도 연구)

  • Heo, Ja-Kyung;Jeong, Jae-Hyuk;Cho, Jung-Hoon;Lee, Jin-Moo;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.6 no.1
    • /
    • pp.63-68
    • /
    • 2008
  • Purpose: We intended to researched the relations between abdominal temperature and leukorrhea. Methods: We selected the 26 leukorrhea patients and 17 control group. We measured 4 points abdominal temperature (Chung-wan(CV12), Kwan-won(CV4), Gui-rae(ST29)) by DITI. We checked the difference of temperature between CV12, CV4, ST29 of leukorrhea group and control group. And we checked the difference of temperature between CV12 and CV4 / Lt. ST29 and Rt. ST29 / CV12 and Lt. ST29 / CV12 and Rt. ST29 / CV4 and Lt. ST29 / CV4 and Rt. ST29. For statistics, we used Mann-Whitney test, SPSS 12.0 for windows. Results: The difference of temperature between CV12, CV4 and ST29 which are abdomen shows statistically insignificant result in this study. But, the difference of temperature between (${\Delta}T$) CV4 and Rt. ST29 which are abdomen shows statistically significant result. Conclusion: The leukorrhea patients show higher temperature CV12, CV4 and ST29 than control group. In lower abdomen, the temperature between leukorrhea and control group shows little difference.

  • PDF

A Road Region Extraction Using OpenCV CUDA To Advance The Processing Speed (처리 속도 향상을 위해 OpenCV CUDA를 활용한 도로 영역 검출)

  • Lee, Tae-Hee;Hwang, Bo-Hyun;Yun, Jong-Ho;Choi, Myung-Ryul
    • Journal of Digital Convergence
    • /
    • v.12 no.6
    • /
    • pp.231-236
    • /
    • 2014
  • In this paper, we propose a processing speed improvement by adding a parallel processing based on device(graphic card) into a road region extraction by host(PC) based serial processing. The OpenCV CUDA supports the many functions of parallel processing method by interworking a conventional OpenCV with CUDA. Also, when interworking the OpenCV and CUDA, OpenCV functions completed a configuration are optimized the User's device(Graphic Card) specifications. Thus, OpenCV CUDA usage provides an algorithm verification and easiness of simulation result deduction. The proposed method is verified that the proposed method has a about 3.09 times faster processing speed than a conventional method by using OpenCV CUDA and graphic card of NVIDIA GeForce GTX 560 Ti model through experimentation.

Clinical Evaluation and The Diagnositic Significances of Disital Infrared Thermal Image(D.I.T.I.) on the Patients of Dam Hun(痰暈) (담훈(痰暈)환자의 임상적 고찰과 복부 적외선 체열촬영의 의의)

  • Park, Mee-Yeon;Choi, Hae-Yun;Kim, Jong-Dae;Song, Kwang-Kyu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.2
    • /
    • pp.488-493
    • /
    • 2006
  • To make a objective diagnosis of Dam Hun(痰暈), we investigated the 63 patients with Dam Hun(痰暈) and 34 normal people as control group. we compared the thermal difference between Chon-jung(CV17 ) and Chung-wan(CV12 中脘), Chon-jung(CV17 ) and Gwan-won(CV4 關元) and we compared the thermal difference of Yang-mun(ST21 梁門), Chun_chu(ST25 天樞), Su-do(ST28 水道), too. All 63 patients had dizziness and GI trouble. They had the symptom - fatigue, nausea vomitting, head heaviness, indigestion, cold limbs, headache, heart burn, constipation, diarrhea, anorexia. And some had edema, numbness, insomnia, palpitation, facial flushing, dysuria, ringing. Considering the average temparature of Chon-jung(CV17 ), Chung-wan(CV12 中脘), Gwan-won(CV4 關元), Yang-mun(ST21 梁門), Chun-chu(ST25 天樞), Su-do(ST28 水道) between the patients group and the control group, the patients group were lower than the control group except for Chon-jung(CV17 ), Gwan-won(CV4 關元), but the statistical significance was not. Considering the thermal difference of Chon-jung(CV17 ) and Chung-wan(CV12 中脘), Gwan-won(CV4 關元), Yang-mun(ST21 梁門), Chun-chu(ST25 天樞), Su-do(ST28 氷道) between the patients group and the control group, the temparature deviation of Chon-jung(CV17 ) and Chung-wan(CV12 中脘), Chon-jung(CV17 ) and Yang-mun(ST21 梁門) was significant. We suggest that coldness of upper abdomen is significant in diagnosis of Dam Hun(痰暈).

Effect of Combined Acupuncture at Hefu(LI4), Taichong(LR3) and Moxibustion at Shangwan(CV13), Zhongwan(CV12), Xiawan(CV10) on the Serum Gastrin Level in Rats (상완, 중완, 하완 구요법과 사관 침요법의 혼합사용이 정상 백서 위 기능에 미치는 영향)

  • Han Sang-Muk;Hwang Tae-Jun;Kim Hong-Jae;Jung Sang-Gu;Jo Seung-Mook;Yu Yun-Cho;Kim Meyong-Dong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.5
    • /
    • pp.1238-1242
    • /
    • 2005
  • Shangwan(CV13), Zhongwan(CV12), Xiawan(CV10), Hefu(L14) and Taichong(LR3) which belong to Conception Vessel and stomach meridian are acupuncture points frequently used for healing gastrointestinal desease in oriental medicine. The present study was conducted to see the effects produced by combined acupuncture(A), electro-acupuncture(EA) and moxibustion using five acupoints which belongs to different meridians on serum gastrin level in rats. Electro-acupuncture (2 Hz, intensity; 10 times muscle twitch threshold) was applied for 30 minutes to Hefu(LI4), Taichong(LR3) under halothane anesthesia. Moxibustion ($1.6{\pm}0.3\;mg$, 5 times of a day) was applied during 3 days to CV10, CV12, CV13 under halothane anesthesia. Combined stimuli of acupuncture at Hefu(LI4), Taichong(LR3) and moxibustion at CV13, CV12 increased serum gastrin level significantly eventough combined simulus of moxibustion on CV 10 was not shown any change. And combined stimul of EA and moxibustion at experimental all groups were not shown any effects. These data suggest that effects of acupuncture and moxibustion are depentent with used acupoints and combination stimuli method.

The Effects of Different Moxibustion Stimulation at Abdominal Acupoints ($CV_{12}$, $CV_6$, $CV_4$) on the Skin Temperature Changes (복부 혈위 뜸 자극 위치의 차이가 체표 온도 변화에 미치는 영향)

  • Kim, Yu Ri;Noh, Seung Hee;Yang, Gi Young;Yook, Tae Han;Kim, Jong Uk
    • Journal of Acupuncture Research
    • /
    • v.30 no.1
    • /
    • pp.71-80
    • /
    • 2013
  • Objectives : This study aimed to investigate the difference of abdominal skin temperature responses following moxibustion comparing stimulation method. Methods : Moxibustion was applied on the acupuncture points of $CV_4$, $CV_6$, $CV_{12}$. Thirty healthy men were randomly divided into two groups, one receiving a single moxibustion stimulation in three locations '$CV_4{\cdot}CV_6{\cdot}CV_{12}$'(n=15) and the other receiving triple moxibustion stimulations in one location '$CV_{12}$'(n=15) for 30 min. To obtain the skin temperature on abdominal region, a thermograph was used. Three arbitrary frames(the upper abdominal, lower abdominal, whole abdominal regions) were made to analyse skin temperature. Thermographic images were obtained at before and after the procedure of indirect moxibustion and 5, 10, 15, 20, 25, 30 min afterwards. Results : An increase in skin temperature on the three abdominal regions was observed following both one point and three points moxibustion administrations. Significant increase in skin temperature of the whole abdominal region was observed at 30 min after the procedure of three points moxibustion compared with one point moxibustion stimulation. A tendency of skin temperature changes over time was observed. Conclusions : In this study, skin temperature of lower abdominal region does not increase after triple moxibustion stimulations on $CV_{12}$. Administration of single moxibustion on $CV_4$, $CV_6$, $CV_{12}$ makes greater changes in skin temperature on the whole abdominal region than triple moxibustion on $CV_{12}$.

Studies on Electrocardiogram of the Normal Korean Native Goat II. Waveforms and Amplitudes of the Unipolar Precordial Chest Leads (정상적인 한국 흑염소의 심전도에 관한 연구 II. 담부단극유도의 파형과 전위)

  • 최인혁;김기주;윤여백;서석열;김남수
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.338-348
    • /
    • 1997
  • The electrocardiographic (ECG) parameters on unipolar precordial chest leads in the normal Korean native goat of 343 heads as to CV$_{6}$LU, CV$_{6}$LL CV$_{6}$RU, CV$_{6}$RL and V10 have been measured with a 3-channel Elertrocardiograph and computed, analysed. All wave types as positive, negatives biphasic and flatting in the P and T waves appeared in all leads but any special wave type was not shown more than 60%. Average amplitudes with the highest frequent rate in P wave were 81.4$\pm$32.0 $\mu $V (52.3%), 59.6$\pm $ 27.5 $\mu $V (50.5 %) of Positive type in leads CV$_{6}$LU and CV$_{6}$LL, and -5fl.5$\pm $22.6 $\mu $V (44.0%) of negative type in leads VIO, and 51.3% and 44% of flatting type in leads CV$_{6}$RU and CV$_{6}$RL, but flatting type of clinic form appeared frequent rate between 53% and 77% in all leads. In T wave, average amplitudes with the highest frequent rate were 265.0$\pm $97.1 $\mu $V (54.0%) and 212.2$\pm $90.7 $\mu $V (57.0%) of positive type in leads CV$_{6}$LL and CV$_{6}$RL, and -252.8$\pm $90.7 $\mu $V (56.6%) of negative in lead V10, but amplitudes of T waves that positive and negative type appeared similarity frequent ra蛇 ware 208.7$\pm $99.7 $\mu $V (42.1%), -159.0$\pm $81.6 (43.8%) in lead CV$_{6}$LU and 153.2$\pm $139.0 $\mu $V (47.3%), -130.0$\pm $81.4 (43.2%) in lead CV$_{6}$RU, Amplitudes of QRS complex wave forms showed the highest frequent rate were 218.2$\pm $96.4 $\mu $V (47.8%), 308.3$\pm $135.2 $\mu $V (46.8 %), 232.8$\pm $126.5 $\mu $V (58.5%) and 225.3$\pm $89.6 $\mu $V (54.9%) of R type in the leeds CV$_{6}$LU, CV$_{6}$LL, CV$_{6}$RU and CV$_{6}$RL, and were -92.5$\pm $79.1 $\mu $V,479.0 $\pm $116.6 $\mu $V (33.2%) and 212.1 $\pm $86.7 $\mu $V (32.8%) of QR and 05 type in the lead V10. These results in the V10, CV$_{6}$RU, CV$_{6}$RL, CV$_{6}$LU, CV$_{6}$LL. may be not starve to purpose of unipolar precordial chest leads.

  • PDF

MEASUREMENT AND CHARACTERIZATION OF FRICTION IN AUTOMOTIVE DRIVESHAFT JOINTS

  • Lee, C.H.
    • International Journal of Automotive Technology
    • /
    • v.8 no.6
    • /
    • pp.723-730
    • /
    • 2007
  • The typical design of automotive driveshafts generally utilizes Constant Velocity(CV) joints as a solution to NVH. CV joints are an integral part of vehicles and significantly affect steering, suspension, and vehicle vibration comfort levels. Thus, CV joints have been favored over universal joints due to the constant velocity torque transfer and plunging capability. Although CV joints are common in vehicle applications, current research works on modeling CV joint friction and assumes constant empirical friction coefficient values. However, such models are long known to be inaccurate, especially under dynamic conditions, which is the case for CV joints. In this paper, an instrumented advanced CV joint friction apparatus was developed to measure the internal friction behavior of CV joints using actual tripod-type joint assemblies. The setup is capable of measuring key performance of friction under different realistic operating conditions of oscillatory speeds, torque and joint installation angles. The apparatus incorporates a custom-installed triaxial force sensor inside of the joint to measure the internal CV joint forces(including friction). Using the designed test setup, the intrinsic interfacial parameters of CV joints were investigated in order to understand their contact and friction mechanisms. The results provide a better understanding of CV joint friction characteristics in developing improved automotive driveshafts.