• Title/Summary/Keyword: CUSTOM

Search Result 1,338, Processing Time 0.027 seconds

A study on the problems in appling CIF, Incoterms 1990 into the contract of sale. (1990년(年) 인코텀즈에 따른 CIF조건(條件)의 활용상(活用上)의 문제점(問題點))

  • Choi, Myung-Kook
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.6
    • /
    • pp.11-51
    • /
    • 1993
  • This study is focused on the problems and the suggestions of proper ideas for solving them which are arisen from appling CIF, Incoterms 1990 into the contract of sale after reviewing of the contents of traditional CIF contract and the main changes of CIF, Incoterms 1990. This study summerized as follows: First, when the seller provide the buyer with non-negotiable sea waybill or inland waterway document instead of negotiable bill of lading, it is my feeling that the essence of symbolic delivery in traditional CIF contract is fading. And if the buyer has paid for the goods in advance, or a bank wishes to use the goods as security for a loan extended to the buyer, it is not sufficient that the buyer or the bank be named as consignee in a non-negotiable document. This is true because the seller by new instractions to the carrier could replace the named consignee with someone else. To protect the buyer or the bank it is therefore necessary that the original instructions from the seller to the carrier to deliver the goods to the named consignee be irrevocable. Second, CIF term can only be used for sea and inland waterway transport. When the ship's rail serves no practical purposes such as in the case of roll-on/roll-off or container traffic, CIP term instead of CIF term is more appropriate to use. Third, the EDI method still contains many legal and technical problems to be solved in order to be used thoroughly' in the international sale of goods. Therefore, the parties wishing to replace the traditional paper-based trade documents by electronic messages must exchange the agreement on EDI each other in order to prevent and sol ye unexpected problems. Forth, it may be that the goods are to be carried in bulk without such marking or naming of consignee as would amount to appropriation. Then the risk will not pass until effective appropriation has been made. Therefore, the seller needs to appropriate by issuing of separate bills of lading or delivery orders for parts of the bulk cargo. And in case the goods are bought while they are carried at sea, some problems on the passing of risk would arise. One possibility is that the buyer might have to assume risks which have already occured at the time when the contract of sale is entered into force. The other possibility would be to let the pissing of the risk concide with the time when the contract of sale is concluded. The parties are advised to ascertain the applicable law and any solution which might follow there form. Finally, Incoterms are restricted to deal with the main principles for the division of functions, costs and risks between the parties and the rest is left to their individual contract as supplemented by the custom of the trade, the individual terms of the contract of sale and the applicable law. Thus, the parties are advised to ascertain the applicable law on their individual contract of sale in order to solve the problems on the transfer of property, the remedy and so on.

  • PDF

Effects of Screw Diameter and Thread Shape on the Strength of Transpedicular Screw Fixation in Posterior Spinal Fusion (후방 척추고정술에서 척추경 나사못의 크기와 형태가 척추 고정력에 미치는 영향에 대한 연구)

  • Mun, Mu-S.;Ryu, Jei-C.;Yoo, Myung-C.;Kim, Ki-T.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.23-26
    • /
    • 1995
  • The objectives of the present study are 1)to find the effect of the diameter of transpedicular screws on their fixational strength in pedicles under static pull-out loading, 2)to determine the biomechanical correlation between the pedicle diameter and the screw diameter, and 3)to find the effects of other factors in the screw design, such as materials, screw pitch, thread height and shape on their fixational strength. Biomechanical tests (Test I) were performed to evaluate the effect of the screw diameter on pull-out strength by using 60 porcine pedicls and six groups of custom-made pedicle screws with different diameters (the major and the minor diameter of the screws used in the testing varied from 4mm upto 9mm and from 3mm upto 8mm, respectively) while all other factors (materials, screw pitch, thread height and shape etc.) were fixed. In Test II, by using 61 porcine pedicles, the relationship between the ratio of the pedicle diameter and the screw diameter(=aspect ratio) of the custum-made screw and the pull-out strength of the screw was investigated. Test III was performed with 94 porcine pedicles and 8 different types of the commercial screws from 6 major productors in order to determine the effect of the screw diameter, pitch and the thread shape on the pull-out strength of the screw, respectively. The results of Test I showed that the axial pull-out resistance of the screw could be increased prportionaly to the screw diameter(P<0.05). But this increase in the pull-out resistance did not found when the screws of 4mm or 9mm in the diameter were employed. It was found from the results of Test II that the screws had its maximum pull-out resistant force when the aspect ratio ranging 40 - 69% (P<0.05). based on the results for the major diameter against the minor diameter of screw, the maximal pull-out resistance was found at 60-65% (P<0.05). According to these biomechanical testing results, it seems that the screw with a moderately large pitch is more desirable and the buttress-shaped screw can provide stronger fixation than the V-shape one can, if other designal factor and conditions were fixed.

  • PDF

Drying time of tray adhesive for adequate tensile bond strength between polyvinylsiloxane impression and tray resin material

  • Yi, Myong-Hee;Shim, Joon-Sung;Lee, Keun-Woo;Chung, Moon-Kyu
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.63-67
    • /
    • 2009
  • STATEMENT OF PROBLEM. Use of custom tray and tray adhesive is clinically recommended for elastomeric impression material. However there is not clear mention of drying time of tray adhesive in achieving appropriate bonding strength of tray material and impression material. PURPOSE. This study is to investigate an appropriate drying time of tray adhesives by evaluating tensile bonding strength between two types of polyvinylsiloxane impression materials and resin tray, according to various drying time intervals of tray adhesives, and with different manufacturing company combination of impression material and tray adhesive. MATERIAL AND METHODS. Adhesives used in this study were Silfix (Dentsply Caulk, Milford, Del, USA) and VPS Tray Adhesive (3M ESPE, Seefeld, Germany) and impression materials were Aquasil Ultra (monophase regular set, Dentsply Caulk, Milford, Del, USA) and Imprint II Garant (regular body, 3M ESPE, Seefeld, Germany). They were used combinations from the same manufacture and exchanged combinations of the two. The drying time was designed to air dry, 5 minutes, 10 minutes, 15 minutes, 20 minutes, and 25 minutes. Total 240 of test specimens were prepared by auto-polymerizing tray material(Instant Tray Mix, Lang, Wheeling, Il, USA) with 10 specimens in each group. The specimens were placed in the Universal Testing machine (Instron, model 3366, Instron Corp, University avenue, Nowood, MA, USA) to perform the tensile test (cross head speed 5 mm/min). The statistically efficient drying time was evaluated through ANOVA and Scheffe test. All the tests were performed at 95% confidence level. RESULTS. The results revealed that at least 10 minutes is needed for Silfix-Aquasil, and 15 minutes for VPS Tray Adhesive-Imprint II, to attain an appropriate tensile bonding strength. VPS Tray Adhesive-Imprint II had a superior tensile bonding strength when compared to Silfix-Aquasil over 15 minutes. Silfix-Aquasil had a superior bonding strength to VPS Tray Adhesive-Aquasil, and VPS Tray Adhesive-Imprint II had a superior tensile bonding strength to Silfix-Imprint II at all drying periods. CONCLUSION. Significant increase in tensile bonding strength with Silfix-Aquasil and VPS Tray adhesive-Imprint II combination until 10 and 15 minutes respectively. Tray adhesive-impression material combination from the same company presented higher tensile bonding strength at all drying time intervals than when using tray adhesive-impression material of different manufactures.

A Study on the Hotel Employees' Perception on Tips (호텔 종사원의 팁에 대한 인식 연구)

  • Lee, Jang-Woo;Kim, Young-Kyu
    • Culinary science and hospitality research
    • /
    • v.15 no.1
    • /
    • pp.191-201
    • /
    • 2009
  • Tipping takes significant part in hospitality industry, especially in hotels and restaurants. According to the recent studies, over US$26.4B were given to the service personnel in the restaurant industry from the customers as tips in 2003 in the US alone. As a result of these developments, tipping has been a legitimate area of academic inquiry in many foreign countries but here in Korea this custom has not drawn much attention due to service charge being placed by the government since 1979. The purpose of this study is to analyse the perception and attitude of tip recipients and compare it with the results of previous studies carried out by Shamir and Parrett. Statistical analyses were carried out to compare the differences of perception between tip recipients and non recipients on the staff role conflict, job satisfaction, pay satisfaction and attitude toward the guests. It is suggested from the finding that the current service charge system needs to be taken into consideration for possible revision or alteration as the management environment and customer needs in the hospitality industry in Korea are changing at an enormous pace. As this study focused on the perception of employees, further study on the perception of customers to tipping is highly recommended.

  • PDF

Effect of High Pressure Processing on the Shelf Life of Seasoned Squid (초고압 가공이 조미오징어의 저장성에 미치는 영향)

  • Gou, Jing-Yu;Zou, Yun-Yun;Choi, Geun-Pyo;Park, Young-Beom;Ahn, Ju-Hee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.8
    • /
    • pp.1136-1140
    • /
    • 2011
  • This study was designed to evaluate the potential of using high pressure processing (HPP) for extending shelf life of seasoned squid during refrigerated storage. The vacuum-packed seasoned squid samples were subjected to 400 MPa for 20 min using a custom-made high pressure processor. Microbial counts, dimethylamine (DMA), trimethylamine (TMA), total biogenic amine, autolytic activity were determined on days 0, 7, 14, and 21 of refrigerated storage. The numbers of indigenous bacteria were effectively reduced by 2.77 log CFU/g after HPP treatment. The amounts of DMA and TMA produced in the control samples increased up to 15.99 and 42.82 mg/g after 7 days of refrigerated storage when compared to 5.27 and 10.21 mg/g the HPP-treated samples, respectively. The autolytic activity of the HPP-treated sample (4.32 nkat/g) significantly lower than that of the control (7.13 nkat/g) after 7 days of refrigerated storage. Therefore, HPP can be applied as a potential squid processing method microbiological safety and shelf life.

Characterization of Rabbit Retinal Ganglion Cells with Multichannel Recording (다채널기록법을 이용한 토끼 망막 신경절세포의 특성 분석)

  • Cho Hyun Sook;Jin Gye-Hwan;Goo Yong Sook
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.228-236
    • /
    • 2004
  • Retinal ganglion cells transmit visual scene as an action potential to visual cortex through optic nerve. Conventional recording method using single intra- or extra-cellular electrode enables us to understand the response of specific neuron on specific time. Therefore, it is not possible to determine how the nerve impulses in the population of retinal ganglion cells collectively encode the visual stimulus with conventional recording. This requires recording the simultaneous electrical signals of many neurons. Recent advances in multi-electrode recording have brought us closer to understanding how visual information is encoded by population of retinal ganglion cells. We examined how ganglion cells act together to encode a visual scene with multi-electrode array (MEA). With light stimulation (on duration: 2 sec, off duration: 5 sec) generated on a color monitor driven by custom-made software, we isolated three functional types of ganglion cell activities; ON (35.0$\pm$4.4%), OFF (31.4$\pm$1.9%), and ON/OFF cells (34.6$\pm$5.3%) (Total number of retinal pieces = 8). We observed that nearby neurons often fire action potential near synchrony (< 1 ms). And this narrow correlation is seen among cells within a cluster which is made of 6~8 cells. As there are many more synchronized firing patterns than ganglion cells, such a distributed code might allow the retina to compress a large number of distinct visual messages into a small number of ganglion cells.

  • PDF

Evaluation of Real-time Target Positioning Accuracy in Spinal Radiosurgery (척추방사선수술시 실시간 추적검사에 의한 병소목표점 위치변이 평가)

  • Lee, Dong Joon
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.290-294
    • /
    • 2013
  • Stereotactic Radiosurgery require high accuracy and precision of patient positioning and target localization. We evaluate the real time positioning accuracy of isocenter using optic guided patient positioning system, ExacTrac (BrainLab, Germany), during spinal radiosurgery procedure. The system is based on real time detect multiple body markers attached on the selected patient skin landmarks. And a custom designed patient positioning verification tool (PPVT) was used to check the patient alignment and correct the patient repositioning before radiosurgery. In this study, We investigate the selected 8 metastatic spinal tumor cases. All type of tumors commonly closed to thoracic spinal code. To evaluate the isocenter positioning, real time patient alignment and positioning monitoring was carried out for comparing the current 3-dimensional position of markers with those of an initial reference positions. For a selected patient case, we have check the isocenter positioning per every 20 millisecond for 45 seconds during spinal radiosurgery. In this study, real time average isocenter positioning translation were $0.07{\pm}0.17$ mm, $0.11{\pm}0.18$ mm, $0.13{\pm}0.26$ mm, and $0.20{\pm}0.37$ mm in the x (lateral), y (longitudinal), z (vertical) directions and mean spatial error, respectively. And body rotations were $0.14{\pm}0.07^{\circ}$, $0.11{\pm}0.07^{\circ}$, $0.03{\pm}0.04^{\circ}$ in longitudinal, lateral, table directions and mean body rotation $0.20{\pm}0.11^{\circ}$, respectively. In this study, the maximum mean deviation of real time isocenter positioning translation during spinal radiosurgery was acceptable accuracy clinically.

Generating Motion- and Distortion-Free Local Field Map Using 3D Ultrashort TE MRI: Comparison with T2* Mapping

  • Jeong, Kyle;Thapa, Bijaya;Han, Bong-Soo;Kim, Daehong;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.4
    • /
    • pp.328-340
    • /
    • 2019
  • Purpose: To generate phase images with free of motion-induced artifact and susceptibility-induced distortion using 3D radial ultrashort TE (UTE) MRI. Materials and Methods: The field map was theoretically derived by solving Laplace's equation with appropriate boundary conditions, and used to simulate the image distortion in conventional spin-warp MRI. Manufacturer's 3D radial imaging sequence was modified to acquire maximum number of radial spokes in a given time, by removing the spoiler gradient and sampling during both rampup and rampdown gradient. Spoke direction randomly jumps so that a readout gradient acts as a spoiling gradient for the previous spoke. The custom raw data was reconstructed using a homemade image reconstruction software, which is programmed using Python language. The method was applied to a phantom and in-vivo human brain and abdomen. The performance of UTE was compared with 3D GRE for phase mapping. Local phase mapping was compared with T2* mapping using UTE. Results: The phase map using UTE mimics true field-map, which was theoretically calculated, while that using 3D GRE revealed both motion-induced artifact and geometric distortion. Motion-free imaging is particularly crucial for application of phase mapping for abdomen MRI, which typically requires multiple breathold acquisitions. The air pockets, which are caught within the digestive pathway, induce spatially varying and large background field. T2* map, that was calculated using UTE data, suffers from non-uniform T2* value due to this background field, while does not appear in the local phase map of UTE data. Conclusion: Phase map generated using UTE mimicked the true field map even when non-zero susceptibility objects were present. Phase map generated by 3D GRE did not accurately mimic the true field map when non-zero susceptibility objects were present due to the significant field distortion as theoretically calculated. Nonetheless, UTE allows for phase maps to be free of susceptibility-induced distortion without the use of any post-processing protocols.

A new meaning of the concept, 'Sijo-samjang(시조삼장)' ('시조삼장'의 새로운 이해)

  • Kwon Soon-Hoi
    • Sijohaknonchong
    • /
    • v.20
    • /
    • pp.197-215
    • /
    • 2004
  • In this paper, I reexamined the word 'Sijo-samjang(시조삼강)' and gave a new meaning of it. In addition, I proposed the new concept of 'Sijo-samjang' which meant the characteristic of a Pyon'ga(편가) in Sijo-chang(시조창). For a long time, 'Sijo-samjang' was regarded as a word which indicated the three sections of a Sijo. It was because of the fixed idea that a Sijo was always composed of a form separated by three parts. Unlike the fixed idea, I found the fact that 'Sijo-samjang' meant singing successively three different Sijos which adapted three different music by reexamining the actual uses of the word in the texts of the days. Thus, I could come to a conclusion that 'Sijo-samjang' was the word indicating a specific music system of a Sijo-chang(singing a Sijo) corresponding to a Pyon'ga of a Gagok(가곡). 'Sijo-samjang' seemed to be molded up while the music of Sijo-chang developed. Usually, a successive singing of the three different Sijos, such as Pyong-sijo(평시조), Chirum-sijo(지름시조), and Sasol-sijo(사설시조), was called 'Sijo-samjang'. However, some of the three could be omitted, and some of it could be substituted by a derived song. This kind of a usual and a derived form seemed to be settled as an important custom of singing a Silo after the 19 century. The main point of the development of music in Sijo-chang was having the characteristic of compilation which meant singing Pyong-sijo, Chirum-sijo, and Sasol-sijo successively. 'Sijo-samjang' was the concept which explained this kind of characteristic and was one of the key words to understand the development of Sijo-chang.

  • PDF

A Study of Evaluating on Values of Customized Spatial Information Technology (맞춤형 국토정보 제공기술 가치평가 연구)

  • Kim, Eun-Hyung
    • Spatial Information Research
    • /
    • v.19 no.2
    • /
    • pp.1-7
    • /
    • 2011
  • For desirable ubiquitous web environments, one of the R&D projects by Korean Land Spatialization Group, has been done to develop a geospatial platform for custom ized land information and geospatial services. To make a better judgement for the investment in the project, analyses for evaluating value of the platform technology and others are done to propose better strategies for the future project management and commercialization of the platform technology. Wiith review of theories and evaluation methods for the technological values, this study suggests 3 evaluating methods: cost approach methods, market approach methods, and income approach methods with focusing on the customized geospatial information platform technology. Results of the evaluation are as follows: the value(over 3,600 million won) estimated by using cost approach methods is larger than the value(over 2,200 million won) using income approach method. Based on evaluation time and methods, the estimated value of geospatial platform technology can be different. This study is performed in relatively early stage of technology developments and results of it will be a reference for commercialization of customized geospatial information platform technology.