• 제목/요약/키워드: CUPID

검색결과 74건 처리시간 0.026초

Modified Abbé flap for reconstruction of Cupid's bow and vermilion tubercle in secondary cleft lip deformity

  • Lee, Jun Won;Lee, Seong Joo;Suh, In Suck;Lee, Chong Kun
    • 대한두개안면성형외과학회지
    • /
    • 제19권1호
    • /
    • pp.13-19
    • /
    • 2018
  • Background: $Abb{\acute{e}}$ flap technique is one of the most challenging operations to correct horizontal deficiencies in secondary cleft lip deformity. Since its first introduction, the operative method was dynamically modified from simple variation to complete conceptual change, but conventional $Abb{\acute{e}}$ flap has many drawbacks in esthetic and functional aspect. Our purpose was reconstructing the symmetry of Cupid's bow and central vermilion tubercle with minimal sequalae. Methods: From 2008 to 2016, this technique was applied to 16 secondary cleft lip patients who had total or more than 60% of unilateral deficiency of Cupid's bow and central lip or tubercle pouting deficiency. A quadrangular-shaped flap was transferred from vermilion including skin and white line of central or contralateral lower lip. Pedicle division and insetting were made at 9 (unilateral) or 10 (bilateral) days after transfer. Secondary lip revision was done with open rhinoplasty after wound maturation. Results: Overall satisfaction was high with modified technique. Scar was minimally noticeable on both upper and lower lip especially. Balanced Cupid's bow and symmetric vermilion tubercle were made with relatively small size of flap compared to conventional $Abb{\acute{e}}$ flap. An accompanying benefit was reduced ectropion of lower lip, which made balanced upper and lower lip protrusion with more favorable profile. Conclusion: A new modified $Abb{\acute{e}}$ flap technique showed great satisfaction. It is worth considering in secondary cleft lip patient who has central lip shortage and asymmetry of upper lip vermilion border line. Our technique is one of the substitutes for correction of horizontal and central lip deficiency with asymmetric Cupid's bow.

Spathiphyllum floribundum cv. Cupid의 기내번식 (In vitro propagation of Spathiphyllum floribundum cv. Cupid)

  • 한봉희;예병우;유희주;신지수
    • 식물조직배양학회지
    • /
    • 제28권4호
    • /
    • pp.209-213
    • /
    • 2001
  • Spathiphyllum floribundum cv. Cupid를 기내에서 대량번식시키기 위하여 일련의 실험을 실시하였다. 신초경정을 LS배지에 TDZ (thidiazuron)와 BA (banzyladenine)가 첨가된 배지에서 배양한 결과, 신초의 증식 및 신초 cluster의 형성은 BA 2.0 mg/L 첨가배지에서 가장 양호하였다. 배지 내 BA와 PBZ (paclobutrazol)의 혼용첨가는 BA 단용첨가보다 신초증식 및 신초 cluster 형성을 촉진하였다. 형성된 신초 cluster를 5∼7 mm로 절단하여 BA또는 TDZ이 첨가된 배지에 배양하였다. BA 2.0∼3.0 mg/L가 첨가된 배지에서 신초수가 가장 많았으며 신초의 증식도 양호하였다. 형성된 신초 cluster 절편체 (5∼7mm)에서 신초의 신장 및 발근은 IBA 2.0∼3.0 mg/L 첨가배지에서 매우 양호하였다. 발근된 식물체는 vermiculite와 pelrlite가 1 : 1로 혼합된 용토에서 95% 이상 순화되었다.

  • PDF

운동량 방정식의 대류항 이산화 방법이 다차원 2상 유동 해석에 미치는 영향 분석 (AN ANALYSIS OF DISCRETIZATION EFFECT OF MOMENTUM CONVECTION TERM FOR MULTI-DIMENSIONAL TWO-PHASE FLOWS)

  • 박익규;조형규;윤한영;정재준
    • 한국전산유체공학회지
    • /
    • 제14권3호
    • /
    • pp.86-94
    • /
    • 2009
  • The non-conservative form of momentum equations is often used for some two-phase flow codes instead of a conservative form because of numerical convenience. Another non-conservative form, so called, a semi-conservative form can improve the numerical solution of these codes maintaining the numerical convenience. It is close to the conservative form but still maintains the feature of the non-conservative form. A semi-conservative form of the momentum equations and a non-conservative form of the momentum equations are implemented in CUPID[1] code. The numerical results of the semi-conservative and the non-conservative forms are compared against analytical solutions and the solutions of the FLUENT code that uses the conservative form. The results clearly showed that the semi-conservative form of the momentum equations provides better solutions than the non-conservative form, especially for heterogeneous two-phase flows.

물-기체 2상 유동 해석을 위한 Semi-Implicit 방법의 대류항에 대한 2차 정확도 확장 (IMPLEMENTATION OF A SECOND-ORDER INTERPOLATION SCHEME FOR THE CONVECTIVE TERMS OF A SEMI-IMPLICIT TWO-PHASE FLOW ANALYSIS SOLVER)

  • 조형규;이희동;박익규;정재준
    • 한국전산유체공학회지
    • /
    • 제14권4호
    • /
    • pp.13-22
    • /
    • 2009
  • A two-phase (gas and liquid) flow analysis solver, named CUPID, has been developed for a realistic simulation of transient two-phase flows in light water nuclear reactor components. In the CUPID solver, a two-fluid three-field model is adopted and the governing equations are solved on unstructured grids for flow analyses in complicated geometries. For the numerical solution scheme, the semi-implicit method of the RELAP5 code, which has been proved to be very stable and accurate for most practical applications of nuclear thermal hydraulics, was used with some modifications for an application to unstructured non-staggered grids. This paper is concerned with the effects of interpolation schemes on the simulation of two-phase flows. In order to stabilize a numerical solution and assure a high numerical accuracy, the second-order upwind scheme is implemented into the CUPID code in the present paper. Some numerical tests have been performed with the implemented scheme and the comparison results between the second-order and first-order upwind schemes are introduced in the present paper. The comparison results among the two interpolation schemes and either the exact solutions or the mesh convergence studies showed the reduced numerical diffusion with the second-order scheme.

Multi-scale simulation of wall film condensation in the presence of non-condensable gases using heat structure-coupled CFD and system analysis codes

  • Lee, Chang Won;Yoo, Jin-Seong;Cho, Hyoung Kyu
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2488-2498
    • /
    • 2021
  • The wall film-wise condensation plays an important role in the heat transfer processes of heat exchangers, refrigerators, and air conditioner. In the field of nuclear engineering, steam condensation is often utilized in safety systems to remove the core decay heat under both transient and accident conditions. In particular, passive containment cooling system (PCCS), are designed to ensure containment safety under severe accident conditions. A computational fluid dynamics (CFD) scale analysis has been conducted to calculate the heat transfer rate of the PCCS. However, despite the increase in computing power, there are challenges in the long-term transient simulation of containment using CFD scale codes. In this study, a heat structure coupling between the CFD and system analysis codes was performed to efficiently analyze PCCS. In addition, the component unstructured program for interfacial dynamics (CUPID) was improved to analyze the condensation behavior of ternary gas mixtures. Thereafter, the condensation heat transfer on the primary side was calculated using the improved CUPID and CFD code, whereas that on the secondary side was simulated using MARS. Both the coupled codes were validated against the CONAN facility database. Finally, conjugate heat transfer simulations with wall condensation in the presence of non-condensable gases were appropriately performed.

정면에서 평가한 한국인 여성 입술의 심미성과 전방 분절 골절단술 후 입술의 평가 (The frontal characteristics of esthetic lips and lips after anterior segmental osteotomy in Korean females)

  • 이범석;강윤구;윤태호;국윤아
    • 대한치과교정학회지
    • /
    • 제37권5호
    • /
    • pp.331-340
    • /
    • 2007
  • 이 연구는 한국인 여자 유명 모델과 일반인의 정면입술의 차이점을 비교하여 아름다운 입술의 특징을 규명하며 양악 전방 분절골절단술을 시행한 환자에서 정면입술의 변화를 측정하고 그 수술 결과를 한국인 모델과 비교하여 차이점을 알아보고자 하였다. 한국인 유명 모델 30명, 일반인 26명과 양악 전방 분절골절단술을 받은 환자의 10명을 대상으로 정면입술 부위의 12개의 선 길이, 홍순의 5개의 각도와 둘레 및 면적을 측정하였고, 통계분석은 unpaired & paired t-test를 이용하였다. 한국인 유명 모델 군과 일반인 군의 비교에서 하안면 얼굴 폭경, 하안면 수직 길이, 상홍순의 높이, 하순의 길이, 상홍순의 구각부 각도와 central bow의 각도는 의미 있는 차이로 일반인 군보다 유명 모델 군에서 작았다. 그러나, 입술의 폭, 하홍순의 높이, Cupid's bow tip간 거리와 하홍순의 구각부 각도는 유명 모델 군에서 컸고 입술의 둘레와 전체 면적에서도 일반인 군보다 쳐다 양악 전방 분절골절단술을 받은 환자의 정면입술에서는 하안면 얼굴 폭경, 상홍순의 높이, Cupid's bow tip에서 구각부까지의 길이와 상홍순의 면적이 통계적으로 의미 있는 변화를 보였고 한국인 유명 모델과의 비교에서 비슷한 수치를 나타내었지만 상순의 길이는 반대로 증가하였다. 연구의 결과는 교정치료 혹은 양악 전방 분절골절단술을 계획할 때 정면 입술 심미성을 평가하는데 도움이 될 것으로 생각된다.

전략적 접근을 통한 미세형 구순열의 수술에서 실제 사용된 술기의 분석 (Analysis of Procedures for Correction of Microform Cleft Lip through Strategic Approaches)

  • 송경호;배용찬;배성환
    • 대한두개안면성형외과학회지
    • /
    • 제14권1호
    • /
    • pp.16-23
    • /
    • 2013
  • Background: Even though degrees of deformation of microform cleft lip are not high, it has to be corrected with various procedures upon conditions and areas since it has various expressions. Many studies have focused on the classifications and procedures, but there are only a few studies on how much these procedures are performed in the actual field. This study aims to analyze the utilization of various procedures upon major correction points. Methods: A total of 52 patients who had been corrected by one surgeon from 1995 to 2011 were enrolled as subjects. Based on the medical records, it was checked whether the incision was made or not along with the correction procedures for alar base and philtral column, Cupid's bow, and vermillion free margin. Results: In case of an incision, full incision (42 times) was conducted most frequently. For alar base and philtral column, muscle re-approximation (25 times) was performed most frequently. However, recently, it was shown that excision on only the affected area and correction with dermis were more likely to be used. For Cupid's bow and vermilion free margin, elliptical excision on the only affected area followed by re-approximation was performed most frequently for 46 times (Cupid's bow) and 44 times (vermilion free margin), respectively. Conclusion: For the correction of microform cleft lip, less invasive procedures are preferred. However, in the actual field, if needed, aggressive procedures consisting of incisions have been conducted to correction. These trends are somewhat changed to utilization of a simple procedure, such as excision on the modified area, followed by a re-approximation rather than complicated procedures using the muscle.

비정렬 격자 기반의 물-기체 2상 유동해석기법에서의 압력기울기 재구성 방법 (A NEW PRESSURE GRADIENT RECONSTRUCTION METHOD FOR A SEMI-IMPLICIT TWO-PHASE FLOW SCHEME ON UNSTRUCTURED MESHES)

  • 이희동;정재준;조형규;권오준
    • 한국전산유체공학회지
    • /
    • 제15권2호
    • /
    • pp.86-94
    • /
    • 2010
  • A thermal-hydraulic code, named CUPID, has been developed for the analysis of transient two-phase flows in nuclear reactor components. A two-fluid three-field model was used for steam-water two-phase flows. To obtain numerical solutions, the finite volume method was applied over unstructured cell-centered meshes. In steam-water two-phase flows, a phase change, i.e., evaporation or condensation, results in a great change in the flow field because of substantial density difference between liquid and vapor phases. Thus, two-phase flows are very sensitive to the local pressure distribution that determines the phase change. This in turn puts emphasis on the accurate evaluation of local pressure gradient. This paper presents a new reconstruction method to evaluate the pressure gradient at cell centers on unstructured meshes. The results of the new scheme for a simple test function, a gravity-driven cavity, and a wall boiling two-phase flow are compared with those of the previous schemes in the CUPID code.

Numerical Evaluation of the Cooling Performance of a Core Catcher Test Facility

  • Lee, Dong Hun;Park, Ik Kyu;Yoon, Han Young;Ha, Kwang Soon;Jeong, Jae Jun
    • 에너지공학
    • /
    • 제22권1호
    • /
    • pp.8-16
    • /
    • 2013
  • A core catcher is considered as a promising engineered system to stabilize the molten corium in the containment during a postulated severe accident in a nuclear power plant. Conceptually, the core catcher consists of a carbon steel body, sacrificial material, protection material, and engineered cooling channel. The cooling capacity of the engineered cooling channel should be guaranteed to remove the decay heat of the molten corium. The flow in ex-vessel core catcher is a combined problem of a two-phase flow in the engineered cooling channel and a single-phase natural circulation in the whole core catcher system. In this study, the analysis of the test facility for the core catcher using the CUPID code, which is a three-dimensional thermal-hydraulic code for the simulation of two-phase flows, was carried out to evaluate its cooling capacity.