• 제목/요약/키워드: CT99

검색결과 346건 처리시간 0.029초

정신분열병 환자에서의 혈중 Homocysteine 농도와 MTHFR C677T, A1298C의 유전자 다형성 (Serum Homocysteine Level and MTHFR C677T, A1298C Gene Polymorphism in Korean Schizophrenics)

  • 이영식;전창무;나철;채석래
    • 생물정신의학
    • /
    • 제12권2호
    • /
    • pp.114-122
    • /
    • 2005
  • Objectives:Recently in schizophrenia high incidence of MTHFR(methylenetetrahydrofolate reductase), which is a main relating enzyme that reduce homocysteine level, genetic variations were reported. So we examined serum homocysteine level and MTHFR gene polymorphism in Korean schizophrenics. Method:We compared serum homocysteine level and MTHFR polymorphism between 235 schizophrenics (100male, 135female) and 235 normal controls(100male, 135female). C677T and A1298C polymorphism of MTHFR gene were analyzed. Results:1) C677T genetic mutation(CT and TT) were more frequent in schizophrenia group than normal control group(p<0.01). But the difference of A1298C mutation frequency was not found between two groups. 2) In schizophrenia patients, TT genotype of C677T mutation showed significantly higher homocysteine level (29.99uM/L) than other group(CT:13.34uM/L, CC:9.34uM/L p<0.01). 3) MTHFR 677 TT homogeneous mutation genotype showed two times more risk(odds ratio=2.15) than 677CC normal genotype in schizophrenia. Conclusion:Some schizophrenia patients with high homocysteine serum level may have C677T TT genotype. In that case, folate ingestion could be a good management for clinical improvement.

  • PDF

Simultaneous placement of an interpositional free gingival graft with nonsubmerged implant placement

  • Sohn, Joo-Yeon;Park, Jung-Chul;Cho, Kyoo-Sung;Kim, Chang-Sung
    • Journal of Periodontal and Implant Science
    • /
    • 제44권2호
    • /
    • pp.94-99
    • /
    • 2014
  • Purpose: Various surgical techniques target achieving adequate keratinized tissue around dental implants; however, these techniques are usually performed before implant placement or upon the exposure of submerged implants. The aim of this case report is to describe a simultaneous placement of an interpositional free gingival graft (iFGG) with that of nonsubmerged implants in a patient lacking keratinized tissue and to assess the longterm outcome of this grafted gingiva. Methods: A wedge-shaped free gingnival graft (FGG), including an epithelium-connective tissue (E-C) portion and a connective-tissue-only (CT) portion, was harvested from the palate. The CT portion was inserted under the buccal flap, and the E-C portion was secured tightly around the implants and to the lingual flap. Results: At the 8-year follow-up, the gingival graft remained firmly attached and was well maintained, with no conspicuous shrinkage or reported discomfort during oral hygiene procedures. The use of an iFGG at a nonsubmerged implant placement minimizes the required number of surgical steps and patient discomfort while providing adequate buccal keratinized tissue. Conclusions: Therefore, the technique could be considered an alternative method in increasing the keratinized tissue for cases that have a minimal amount of keratinized tissue.

Objective Outcomes of Closed Reduction According to the Type of Nasal Bone Fracture

  • Kang, Chang Min;Han, Dong Gil
    • 대한두개안면성형외과학회지
    • /
    • 제18권1호
    • /
    • pp.30-36
    • /
    • 2017
  • Background: Nasal fractures have a tendency of resulting in structural or functional complications, and the results can vary according to the type of nasal bone fracture. The aim of this study was to evaluate the objective postoperative results according to the type of nasal bone fractures. Methods: We reviewed 313 patients who had a closed reduction of nasal bone fracture. The classification of nasal bone fracture by Stranc and Robertson was used to characterize the fracture type: frontal impact group type I (FI), frontal impact group type II (FII), lateral impact group type I (LI), lateral impact group type II (LII), and comminuted fracture group (C). For each patient, we tried to use the same axial image section of computed tomographic (CT) scans before and immediately after operation. Postoperative outcomes were classified into 4 grades: excellent (E), good (G), fair (F), and poor (P). We also analyzed postoperative complications by fracture type. Results: Regarding the postoperative CT images, 189 subjects showed E results, 99 subjects showed G, 18 subjects showed F, and 7 subjects showed P reduction. The rate of operation results graded as E by each fracture type was 66.67% in FI, 52.0% in FII, 64.21% in LI, 62.79% in LII, and 21.74% in C. Complications of FI (7.14%), LII (13.95%), and C (13.04%) groups occurred more than in the FII (4.00%) and LI (4.21%) groups. Conclusion: It seems that the operation result by fracture type was better in the FI, LI, and LII type than the FII and C type; after one month, however, LII type showed more complications than other types. The septal fracture can be thought to affect early reduction results in nasal bone fractures.

전산화 단층촬영을 이용한 한국 성인의 둔부 피하지방두께 측정 -근육주사 바늘길이 산정을 위한 기초조사- (Gluteal Subcutaneous Fat Thickness Measured by Computed Tomography as an Estimate of Proper Gluteal Intramuscular Injections in Korean Adults)

  • 주가을;송경애
    • 대한간호학회지
    • /
    • 제40권2호
    • /
    • pp.247-254
    • /
    • 2010
  • Purpose: To study the thickness of gluteal subcutaneous fat (SCF) and propose an adequate length for needle for gluteal intramuscular injections based on computed tomography (CT) measurements. Methods: The thickness of gluteal SCF were measured and studied for 568 patients who visited a tertiary hospital in Seoul, Korea between January 2007 and February 2009 for routine health screening and who had abdominopelvic CT. Results: The average thickness of gluteal SCF was $15.92{\pm}4.08mm$ in males and $24.90{\pm}5.47mm$ in females. The thickness of gluteal SCF differed significantly according to gender. The gluteal SCF thickness was greater than 20.4 mm for 54 (12.3%) of the 440 male patients and 99 (77.3%) of the 128 female patients. Conclusion: The most common syringe needle used for gluteal intramuscular injections in Korea is a 23 G, 25.4 mm-needle. The SCF thickness must be less than 20.4 mm in order to reach the dorsogluteal muscles to a depth of at least 5 mm if this 25.4 mm needle is used. In many patients, especially in female patients, the 25.4 mm needles will result in improper intramuscular injections with the injection being into the SCF. Therefore an appropriate needle should be selected by considering the gender and SCF thickness of patients receiving gluteal intramuscular injections.

Clinical Implementation of 3D Printing in the Construction of Patient Specific Bolus for Photon Beam Radiotherapy for Mycosis Fungoides

  • Kim, Sung-woo;Kwak, Jungwon;Cho, Byungchul;Song, Si Yeol;Lee, Sang-wook;Jeong, Chiyoung
    • 한국의학물리학회지:의학물리
    • /
    • 제28권1호
    • /
    • pp.33-38
    • /
    • 2017
  • Creating individualized build-up material for superficial photon beam radiation therapy at irregular surface is complex with rice or commonly used flat shape bolus. In this study, we implemented a workflow using 3D printed patient specific bolus and describe our clinical experience. To provide better fitted build-up to irregular surface, the 3D printing technique was used. The PolyLactic Acid (PLA) which processed with nontoxic plant component was used for 3D printer filament material for clinical usage. The 3D printed bolus was designed using virtual bolus structure delineated on patient CT images. Dose distributions were generated from treatment plan for bolus assigned uniform relative electron density and bolus using relative electron density from CT image and compared to evaluate the inhomogeneity effect of bolus material. Pretreatment QA is performed to verify the relative electron density applied to bolus structure by gamma analysis. As an in-vivo dosimetry, Optically Stimulated Luminescent Dosimeters (OSLD) are used to measure the skin dose. The plan comparison result shows that discrepancies between the virtual bolus plan and printed bolus plan are negligible. (0.3% maximum dose difference and 0.2% mean dose difference). The dose distribution is evaluated with gamma method (2%, 2 mm) at the center of GTV and the passing rate was 99.6%. The OSLD measurement shows 0.3% to 2.1% higher than expected dose at patient treatment lesion. In this study, we treated Mycosis fungoides patient with patient specific bolus using 3D printing technique. The accuracy of treatment plan was verified by pretreatment QA and in-vivo dosimetry. The QA results and 4 month follow up result shows the radiation treatment using 3D printing bolus is feasible to treat irregular patient skin.

Comparison of the second and third intercostal spaces regarding the use of internal mammary vessels as recipient vessels in DIEP flap breast reconstruction: An anatomical and clinical study

  • Seong, Ik Hyun;Woo, Kyong-Je
    • Archives of Plastic Surgery
    • /
    • 제47권4호
    • /
    • pp.333-339
    • /
    • 2020
  • Background The purpose of this study was to compare the anatomical features of the internal mammary vessels (IMVs) at the second and third intercostal spaces (ICSs) with regard to their use as recipient vessels in deep inferior epigastric artery perforator (DIEP) flap breast reconstruction. Methods A total of 38 consecutive DIEP breast reconstructions in 36 patients were performed using IMVs as recipient vessels between March 2017 and August 2018. The intraoperative findings and postoperative complications were analyzed. Anatomical analyses were performed using intraoperative measurements and computed tomography (CT) angiographic images. Results CT angiographic analysis revealed the mean diameter of the deep inferior epigastric artery to be 2.42±0.27 mm, while that of the deep inferior epigastric vein was 2.91±0.30 mm. A larger mean vessel diameter was observed at the second than at the third ICS for both the internal mammary artery (2.26±0.32 mm vs. 1.99±0.33 mm, respectively; P=0.001) and the internal mammary vein (IMv) (2.52±0.46 mm vs. 2.05±0.42 mm, respectively; P<0.001). Similarly, the second ICS was wider than the third (18.08±3.72 mm vs. 12.32±2.96 mm, respectively; P<0.001) and the distance from the medial sternal border to the medial IMv was greater (9.49±2.28 mm vs. 7.18±2.13 mm, respectively; P<0.001). Bifurcations of the IMv were found in 18.4% of cases at the second ICS and in 63.2% of cases at the third ICS. Conclusions The IMVs at the second ICS had more favorable anatomic features for use as recipient vessels in DIEP flap breast reconstruction than those at the third ICS.

복령행인감초탕(茯苓杏仁甘草湯) 투여로 호전된 흉막삼출 환자 1례 (A Case Report of a Patient with Pleural Effusion treated with Bokryunghaengingamcho-tang)

  • 김동현;신현수;이혜진;정순대;박혜진;이진우;김정현;안정조;조현경;유호룡;김윤식;설인찬
    • 혜화의학회지
    • /
    • 제20권2호
    • /
    • pp.99-104
    • /
    • 2012
  • The purpose of this study is to report a patient with pleural effusion improved by oriental medical treatment. The patient was treated with Bokryunghaengingamcho-tang and acupunture. We measured pleural effusion by Chest CT, twice a month. Pleural effusion decreased in Chest CT after oriental medical treatment. This study suggests that Bokryunghaengingamcho-tang is effective in pleural effusion.

3D Printed Titanium Implant for the Skull Reconstruction: A Preliminary Case Study

  • Choi, Jong-Woo;Ahn, Jae-Sung
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권2호
    • /
    • pp.99-102
    • /
    • 2014
  • The skull defect can be made after the trauma, oncologic problems or neurosurgery. The skull reconstruction has been the challenging issue in craniofacial fields for a long time. So far the skull reconstruction with autogenous bone would be the standard. Although the autogenous bone would be the ideal one for skull reconstruction, donor site morbidity would be the inevitable problem in many cases. Meanwhile various types of allogenic and alloplastic materials have been also used. However, skull reconstruction with many alloplastic material have produced no less complications including infection, exposure, and delayed wound healing. Because the 3D printing technique evolved so fast that 3D printed titanium implant were possible recently. The aim of this trial is to try to restore the original skull anatomy as possible using the 3D printed titanium implant, based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. And we fabricated Titanium implant to reconstruct three-dimensional orbital structure in advance, using the 3D printer. This prefabricated Titanium-implant was then inserted onto the defected skull and fixed. Three dimensional printing technique of titanium material based on the computer simulation turned out to be very successful in this patient. Individualized approach for each patient could be an ideal way to manage the traumatic patients in near future.

Development of a High-Resolution Multi-Locus Microsatellite Typing Method for Colletotrichum gloeosporioides

  • Mehta, Nikita;Hagen, Ferry;Aamir, Sadaf;Singh, Sanjay K.;Baghela, Abhishek
    • Mycobiology
    • /
    • 제45권4호
    • /
    • pp.401-408
    • /
    • 2017
  • Colletotrichum gloeosporioides is an economically important fungal pathogen causing substantial yield losses indifferent host plants. To understand the genetic diversity and molecular epidemiology of this fungus, we have developed a novel, high-resolution multi-locus microsatellite typing (MLMT) method. Bioinformatic analysis of C. gloeosporioides unannotated genome sequence yielded eight potential microsatellite loci, of which five, CG1 $(GT)_n$, CG2 $(GT1)_n$, CG3 $(TC)_n$, CG4 $(CT)_n$, and CG5 $(CT1)_n$ were selected for further study based on their universal amplification potential, reproducibility, and repeat number polymorphism. The selected microsatellites were used to analyze 31 strains of C. gloeosporioides isolated from 20 different host plants from India. All microsatellite loci were found to be polymorphic, and the approximate fragment sizes of microsatellite loci CG1, CG2, CG3, CG4, and CG5 were in ranges of 213-241, 197-227, 231-265, 209-275, and 132-188, respectively. Among the 31 isolates, 55 different genotypes were identified. The Simpson's index of diversity (D) values for the individual locus ranged from 0.79 to 0.92, with the D value of all combined five microsatellite loci being 0.99. Microsatellite data analysis revealed that isolates from Ocimum sanctum, Capsicum annuum (chili pepper), and Mangifera indica (mango) formed distinct clusters, therefore exhibited some level of correlation between certain genotypes and host. The developed MLMT method would be a powerful tool for studying the genetic diversity and any possible genotype-host correlation in C. gloeosporioides.

A Morphometric Analysis of the Foramen Ovale and the Zygomatic Points Determined by a Computed Tomography in Patients with Idiopathic Trigeminal Neuralgia

  • Hwang, Sung-Hyuk;Lee, Myung-Ki;Park, June-Woo;Lee, Jae-Eon;Cho, Chang-Won;Kim, Dae-Jo
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권3호
    • /
    • pp.202-205
    • /
    • 2005
  • Objective : The purpose of this study is to measure the dimensions of foramen ovale and to localize the zygomatic point using computed tomography[CT] in Korean adults with idiopathic trigeminal neuralgia. Methods : Facial axial CT scans using the orbitomeatal plane were performed in 67patients [39males and 28females; mean age 58.8years] with idiopathic classic trigeminal neuralgia. We measured the size of the foramen ovale and localized the zygomatic point which was a skin marker over the ipsilateral zygoma that approximates the lateral projection of a straight line joining the centers of the two foramen ovale. Results : The axial dimensions of the foramen ovale on the orbitomeatal plane were of average length : $8.18{\pm}0.82mm$ [range $6.9{\sim}11.5mm$]. width : $4.06{\pm}0.86mm$ [$2.5{\sim}5.7mm$]. The average distance between the external acoustic meatus and the zygomatic point was $21.64{\pm}1.99mm$ [$16.3{\sim}25.0mm$] and the average distance of anterior margin of condylar process of mandible to zygomatic point was $4.29{\pm}1.19mm$ [$1.0{\sim}7.0mm$]. Conclusion : The anatomical understandings including the size of the foramen ovale and localization of the zygomatic point could be helpful in determining a plan of percutaneous approaches to foramen ovale.