• 제목/요약/키워드: CT99

검색결과 348건 처리시간 0.027초

장림프관 확장증 1례 (A Case of Intestinal Lymphangiectasia)

  • 임형은;정민지;유기환;홍영숙;이주원;김순겸
    • Clinical and Experimental Pediatrics
    • /
    • 제46권9호
    • /
    • pp.921-925
    • /
    • 2003
  • 저자들은 얼굴 부종, 복부 팽만 및 저알부민혈증을 주소로 내원한 8세 환아에서 원발성 장림프관 확장증으로 진단된 1례를 경험하였기에 문헌 고찰과 함께 보고하는 바이다.

Parotid gland sparing effect by computed tomography-based modified lower field margin in whole brain radiotherapy

  • Cho, Oyeon;Chun, Mison;Park, Sung Ho;Oh, Young-Taek;Kim, Mi-Hwa;Park, Hae-Jin;Nam, Sang Soo;Heo, Jaesung;Noh, O Kyu
    • Radiation Oncology Journal
    • /
    • 제31권1호
    • /
    • pp.12-17
    • /
    • 2013
  • Purpose: Parotid gland can be considered as a risk organ in whole brain radiotherapy (WBRT). The purpose of this study is to evaluate the parotid gland sparing effect of computed tomography (CT)-based WBRT compared to 2-dimensional plan with conventional field margin. Materials and Methods: From January 2008 to April 2011, 53 patients underwent WBRT using CT-based simulation. Bilateral two-field arrangement was used and the prescribed dose was 30 Gy in 10 fractions. We compared the parotid dose between 2 radiotherapy plans using different lower field margins: conventional field to the lower level of the atlas (CF) and modified field fitted to the brain tissue (MF). Results: Averages of mean parotid dose of the 2 protocols with CF and MF were 17.4 Gy and 8.7 Gy, respectively (p < 0.001). Mean parotid dose of both glands ${\geq}20$ Gy were observed in 15 (28.3%) for CF and in 0 (0.0%) for MF. The whole brain percentage volumes receiving >98% of prescribed dose were 99.7% for CF and 99.5% for MF. Conclusion: Compared to WBRT with CF, CT-based lower field margin modification is a simple and effective technique for sparing the parotid gland, while providing similar dose coverage of the whole brain.

Diagnostic Performance of Deep Learning-Based Lesion Detection Algorithm in CT for Detecting Hepatic Metastasis from Colorectal Cancer

  • Kiwook Kim;Sungwon Kim;Kyunghwa Han;Heejin Bae;Jaeseung Shin;Joon Seok Lim
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.912-921
    • /
    • 2021
  • Objective: To compare the performance of the deep learning-based lesion detection algorithm (DLLD) in detecting liver metastasis with that of radiologists. Materials and Methods: This clinical retrospective study used 4386-slice computed tomography (CT) images and labels from a training cohort (502 patients with colorectal cancer [CRC] from November 2005 to December 2010) to train the DLLD for detecting liver metastasis, and used CT images of a validation cohort (40 patients with 99 liver metastatic lesions and 45 patients without liver metastasis from January 2011 to December 2011) for comparing the performance of the DLLD with that of readers (three abdominal radiologists and three radiology residents). For per-lesion binary classification, the sensitivity and false positives per patient were measured. Results: A total of 85 patients with CRC were included in the validation cohort. In the comparison based on per-lesion binary classification, the sensitivity of DLLD (81.82%, [81/99]) was comparable to that of abdominal radiologists (80.81%, p = 0.80) and radiology residents (79.46%, p = 0.57). However, the false positives per patient with DLLD (1.330) was higher than that of abdominal radiologists (0.357, p < 0.001) and radiology residents (0.667, p < 0.001). Conclusion: DLLD showed a sensitivity comparable to that of radiologists when detecting liver metastasis in patients initially diagnosed with CRC. However, the false positives of DLLD were higher than those of radiologists. Therefore, DLLD could serve as an assistant tool for detecting liver metastasis instead of a standalone diagnostic tool.

두경부 양성자 치료계획 시 MVCT를 이용한 Metal Volume 평가 및 양성자 선량분포 평가 (Evaluation of Metal Volume and Proton Dose Distribution Using MVCT for Head and Neck Proton Treatment Plan)

  • 서성국;권동열;박세준;박용철;최병기
    • 대한방사선치료학회지
    • /
    • 제31권1호
    • /
    • pp.25-32
    • /
    • 2019
  • 목 적: 두경부 방사선 치료 시 Dental Implant에 의한 Metal Artifact로 인해 보철물의 크기, 모양 및 Volume이 달라지고 이로 인해 타겟 및 주변 정상조직에 대한 방사선치료계획의 정확성이 떨어진다. 본 연구는 치아크기를 재현한 Metal을 KVCT, SMART-MAR CT, MVCT를 통해 영상을 획득 하여 Volume을 평가하고 양성자 치료계획에 적용시켜 선량분포의 차이를 분석해 보고자 한다. 대상 및 방법: 치과에서 치료하는 방법을 고려하여 인레이, 크라운, 브릿지와 비슷한 크기의 A보철물($0.5{\times}0.5{\times}0.5cm$), B보철물($1{\times}1{\times}1cm$), C보철물($1{\times}2{\times}1cm$)을 저용융점납합금(Cerrobend, $9.64g/cm^3$) 사용하여 제작하였다. In House Head & Neck Phantom 안에 보철물를 위치시키고 CT Simulator(Discovery CT 590RT, GE, USA)를 이용해 Slice thickness 1.25 mm로 KVCT 영상과 SMART-MAR 영상을 획득하였다. MVCT 영상은 $RADIXACT^{(R)}$ Series(Accuray $Pricision^{(R)}$, USA)을 이용해 동일한 방법으로 획득하였다. MVCT, SMART-MAR CT, KVCT를 통해 획득한 보철물의 형상을 전산화 치료계획장비 Pinnacle(Ver 9.10, Philips, Palo Alto, USA)의 Autocontour Thresholds Raw Values를 통해 X, Y, Z축의 크기 및 Volume을 비교하였다. 양성자 치료계획은 위의 실험에서 얻은 보철물B($1{\times}1{\times}1cm$)의 각 CT별 치아 Contour를 KVCT 상에 fusion하여 양성자 치료계획(Ray station 5.1, RaySearch, USA)을 세우고 선량의 차이를 비교 평가하였다. 결 과: 실측 사이즈 대비 A보철물(MVCT : 1.0배, SMART-MAR CT : 1.84배, KVCT : 1.92배), B보철물(MVCT : 1.02배, SMART-MAR CT : 1.47배, KVCT : 1.82배), C보철물(MVCT : 1.0배, SMART-MAR CT : 1.46배, KVCT : 1.66배)로 각 크기의 보철물에서 MVCT가 가장 실제 Volume과 유사하게 측정되었다. 양성자 치료계획에서 B보철물의 Volume을 각각 적용하여 측정한 결과 $D_{99\%}$ volume의 선량이 기준 3082 CcGE 대비 MVCT:3094 CcGE, SMART-MAR CT:2902 CcGE, KVCT:2880 CcGE로 측정되었다. 결 론: 전체적인 Volume과 X축 Z축의 크기는 MVCT에서 실제 크기와 가장 일치했고 superior-Inferior방향인 Y축은 CT에 따라 차이 없이 길이가 일정했다. 두경부 양성자 치료 시 보철물의 크기, 모양 및 Volume이 비슷한 MVCT에서 가장 실제 값과 비슷한 선량분포를 보였고 MVCT를 이용한 보철물의 contour를 KVCT에 fusion하여 양성자치료계획에 적용 시 매우 유용할 것으로 사료된다.

Radiology Residents' Independent Diagnosis of Appendicitis Using 2-mSv Computed Tomography: A Secondary Analysis of a Large Pragmatic Randomized Trial

  • Jungheum Cho;Hae Young Kim;Seungjae Lee;Ji Hoon Park;Kyoung Ho Lee
    • Korean Journal of Radiology
    • /
    • 제24권6호
    • /
    • pp.529-540
    • /
    • 2023
  • Objective: To compare the diagnostic performance and clinical outcomes of 2-mSv computed tomography (CT) and conventional-dose CT (CDCT), following radiology residents' interpretation of CT examinations for suspected appendicitis. Materials and Methods: Altogether, 3074 patients with suspected appendicitis aged 15-44 years (28 ± 9 years, 1672 females) from 20 hospitals were randomly assigned to the 2-mSv CT (n = 1535) or CDCT (n = 1539) groups in a pragmatic trial from December 2013 and August 2016. Overall, 107 radiology residents participated in the trial as readers in the form of daily practice after online training for 2-mSv CT. They made preliminary CT reports, which were later finalized by attending radiologists via addendum reports, for 640 and 657 patients in the 2-mSv CT and CDCT groups, respectively. We compared the diagnostic performance of the residents, discrepancies between preliminary and addendum reports, and clinical outcomes between the two groups. Results: Patient characteristics were similar between the 640 and 657 patients. Residents' diagnostic performance was not significantly different between the 2-mSv CT and CDCT groups, with a sensitivity of 96.0% and 97.1%, respectively (difference [95% confidence interval {CI}], -1.1% [-4.9%, 2.6%]; P = 0.69) and specificity of 93.2% and 93.1%, respectively (0.1% [-3.6%, 3.7%]; P > 0.99). The 2-mSv CT and CDCT groups did not significantly differ in discrepancies between the preliminary and addendum reports regarding the presence of appendicitis (3.3% vs. 5.2%; -1.9% [-4.2%, 0.4%]; P = 0.12) and alternative diagnosis (5.5% vs. 6.4%; -0.9% [-3.6%, 1.8%]; P = 0.56). The rates of perforated appendicitis (12.0% vs. 12.6%; -0.6% [-4.3%, 3.1%]; P = 0.81) and negative appendectomies (1.9% vs. 1.1%; 0.8% [-0.7%, 2.3%]; P = 0.33) were not significantly different between the two groups. Conclusion: Diagnostic performance and clinical outcomes were not significantly different between the 2-mSv CT and CDCT groups following radiology residents' CT readings for suspected appendicitis.

호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증 (Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period)

  • 전수동;배선명;윤인하;강태영;백금문
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.137-147
    • /
    • 2014
  • 목 적 : 호흡연동 용적변조 회전방사선치료(Gated Volumetric Modulated Arc Therapy)에서 환자의 호흡주기 변화에 따른 선량전달의 정확성을 검증하고자 한다. 대상 및 방법 : 실험에는 TrueBeam STxTM(Varian Medical Systems, Palo Alto, CA)치료기를 사용하였다. 인체모형등가팬텀(Rando Phantom, Alderson Resarch Laboratories Inc. Stamford. CT, USA)의 전산화단층영상에 전산화치료계획시스템(Eclipse 10.0, Varian, USA)을 이용하여 10 MV FFF(Flatenning Filter Free), 선량률 1200 MU/min으로 1500 cGy/fx(Case1, 2, 3)과 220 cGy/fx(Case4, 5, 6)의 치료계획을 수립하였다. $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc)을 이용하여 1.5, 2.5, 3.5, 4.5 sec의 일정한 호흡주기와 평균호흡주기가 2.2, 3.5 sec인 환자의 호흡주기를 재현하였고 위상모드 30~70% 구간에서 방사선이 조사되도록 설정하였다. 각각의 호흡 조건에서 2차원 이온전리함 배열 검출기(I'mRT Matrixx, IBA Dosimetry, Germany)와 MultiCube Phantom(IBA Dosimetry, Germany)을 이용하여 측정하였고 세기변조 방사선치료 분석 프로그램(OmniPro I'mRT, IBA Dosimetry, Germany)을 이용하여 Gamma pass rate(3 mm, 3%)을 비교하였다. 결 과 : Case 1, 2, 3, 4, 5, 6의 Gamma pass rate은 일정한 호흡주기 1.5 sec에서 100.0, 97.6, 98.1, 96.3, 93.0, 94.8%, 2.5 sec에서 98.8, 99.5, 97.5, 99.5, 98.3, 99.6%, 3.5 sec에서 99.6, 96.6, 97.5, 99.2, 97.8, 99.1%, 4.5 sec에서 99.4, 96.3, 97.2, 99.0, 98.0, 99.3%의 결과를 보였다. 환자의 호흡을 재현한 경우 평균 호흡주기 2.2 sec에서는 97.7, 95.4, 96.2, 98.9, 96.2, 98.4%, 3.5 sec에서는 97.3, 97.5, 96.8, 100.0, 99.3 99.8%의 결과를 보였다. 결 론 : 2.5 sec이상의 일정한 호흡주기와 환자의 호흡을 재현한 실험에서 Gamma pass rate 95%이상의 임상적으로 신뢰할 만한 결과를 보였다. 일정한 호흡주기 1.5 sec의 Case 5, 6 에서 93.0, 94.8%의 결과를 보였으나 100명의 환자 호흡주기 분석 결과 1.5 sec의 호흡을 지속했던 경우는 없었던 점으로 보아 대부분의 호흡조건에서 정확한 선량전달이 가능함을 확인 하였다. 다만 극히 짧은 호흡주기로 인한 오차발생 가능성을 배제할 수 없기 때문에 치료전 선량전달 정확성 검증이 선행되어야 하며 모의치료시 환자 교육으로 안정된 호흡을 유지하고 정확한 모니터링을 통해 치료중 환자 호흡변화에 대처한다면 더욱 안정적이고 정확한 치료가 이루어질 것으로 사료된다.

단순포진 뇌염의 $^{99m}TC-HMPAO$ 국소 뇌혈류 SPECT의 소견 (Findings of $^{99m}TC-HMPAO$ Regional Cerebral Blood Flow SPECT in a Case of Herpes Simplex Encephalitis)

  • 안명임;이성용;김종우;박용휘
    • 대한핵의학회지
    • /
    • 제23권1호
    • /
    • pp.85-87
    • /
    • 1989
  • Herpes simplex encephalitis (HSE) is one of the fulminant necrotizing, often fatal sporadic form of the encephalitis caused by herpes simplex type I virus. Characteristically, there is early and almost constant involvement of one or both temporal lobes, although there are common additional areas of involvement. Appropriate early treatment following correct diagnosis by clinical findings, CSF study, EEG and several radiological studies including angiography, redionuclide studies, CT or MRI can reduce its mortality and severity of the sequelae. We report a case of HSE diagnosed by adjuvant study of $^{99m}Tc-HMPAO$ regional cerebral blood flow SPECT, which showed a marked increase in bitemporal cerebral blood flow in a 24-year-old man.

  • PDF

원발성 간암환자에서 관찰된 $^{99m}Tc$-DISIDA의 비장 섭취 1예 (A Case of Hepatoma with Hot Uptake of $^{99m}Tc$-DISIDA to Spleen)

  • 이예봉;김성진;박언휘;방인숙;김홍주;윤성철;이원재
    • 대한핵의학회지
    • /
    • 제27권1호
    • /
    • pp.140-143
    • /
    • 1993
  • We report a case of hepatoma which had a suggested splenic metastasis in a 64 year-old male patient. Hepatoma proved by abdominal CT (Computed Tomography) and considerable accumulation of $^{99m}Tc$-DISIDA was noted in a enlarged spleen. We suggests the splenic uptake of the radionuclide corresponded to the diffuse metastasis of hepatoma to spleen.

  • PDF

PET 검사 시 Reconstructed data와 Re-sliced data의 표준섭취계수와 Metabolic Tumor Volume의 비교 평가 (Evaluation of Standardized Uptake Value and Metabolic Tumor Volume between Reconstructed data and Re-sliced data in PET Study)

  • 도용호;이홍재;김진의
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.3-8
    • /
    • 2016
  • PET 검사에서 SUV는 암의 원발 부위, 전이여부 파악 및 병기결정, 재발여부 판단에 도움을 주는 지표이다. 특히 항암, 방사선치료 후 효과 판정을 위한 검사 시 이전 검사와의 SUV 비교 평가가 중요시 된다. 그러나 핵의학과 에서 자체적으로 데이터를 저장하는 외장하드, mini PACS 등의 저장 장치는 데이터 손실의 가능성을 가지고 있다. 이에 본 연구에서는 workstation의 reconstructed data (R-D)와 병원 PACS로 전송한 R-D, re-sliced data (S-D) 사이의 SUV를 비교 평가하여 자체 저장장치의 데이터 손실 시 PACS로 전송한 데이터의 사용가능 여부를 확인 하고자 한다. Biograph Truepoint 40, mCT 40, mCT 64, mMR (Siemens, Germany)장비에서 2015년 1월부터 2월까지 $^{18}F-FDG$ PET 검사를 시행한 20명($60.5{\pm}8.3$세)의 데이터를 분석하였다. Workstation의 R-D와 PACS의 R-D, S-D 데이터를 Syngo.via 프로그램으로 전송하여 liver, aorta, tumor 부위의 max SUV($SUV_{max}$), peak SUV ($SUV_{peak}$)와 tumor의 metabolic tumor volume (MTV)를 측정하였다. Workstation과 PACS의 R-D에서 liver, aorta, tumor의 평균 $SUV_{max}$$2.95{\pm}0.59$, $2.35{\pm}0.61$, $10.36{\pm}6.15$ 이었고 $SUV_{peak}$$2.70{\pm}0.51$, $2.07{\pm}0.43$, $7.67{\pm}3.73$으로 동일하였으며 통계적으로 유의한 차이가 없었다(p>0.05). PACS의 S-D는 R-D대비 평균 $SUV_{max}$는 5.18%, 7.22%, 12.11%, $SUV_{peak}$는 2.61%, 3.63%, 10.07% 감소하였으며 통계적으로 유의한 차이가 있었다(p<0.05). R-D와 S-D에서 결과 값의 상관계수는 $SUV_{max}$에서 0.99, 0.96, 0.99이었고 $SUV_{peak}$에서 0.99, 0.99, 0.99로 모두 양의 상관관계가 있었다. Bland-Altman 분석에서 2표준편차는 $SUV_{max}$에서 0.125, 0.290, 1.864이었고 $SUV_{peak}$에서 0.053, 0.103, 0.826이었다. Tumor의 MTV는 workstation과 PACS의 R-D에서 모두 $14.21{\pm}12.72cm^3$로 동일하였다(p>0.05). PACS의 S-D에서는 R-D 대비 0.12% 감소하였으며 통계적으로 유의한 차이가 없었다(p>0.05). R-D와 S-D에서 상관계수는 0.99이었고 Bland-Altman 분석에서 2표준편차는 2.243이였다. 본 논문에서 PACS에 저장된 R-D의 경우 workstation의 R-D와 비교하여 $SUV_{max}$, $SUV_{peak}$, MTV 모두에서 동일한 값을 보였으나 S-D의 경우 상관관계는 높지만 MTV를 제외한 $SUV_{max}$, $SUV_{peak}$는 통계적으로 유의한 차이가 있었다. R-D를 안정성 있는 병원 PACS에 저장한다면 자체 저장장치의 데이터 손실 시 이전 PET 데이터와의 비교에서 신뢰성 있는 SUV 분석이 가능할 것이라 생각된다.

  • PDF

CT상 폐암과 유사하게 보이는 기관지 탄분 섬유화증의 자기공명영상 소견 (Anthracofibrosis Mimicking Lung Cancer on CT: MR Imaging Findings)

  • 류대식;이덕희;정승문;최수정;박성빈;박만수;강길현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제5권1호
    • /
    • pp.18-23
    • /
    • 2001
  • 목적 : 전산화단층촬영(CT)상 폐암과 유사하게 보인 기관지 탄분 섬유화증 환자에서 자기공명영상(MRI) 소견을 알아보고자 하였다. 대상 및 방법 : 기관지내시경검사상 기관지 탄분 섬유화증으로 입증된 50명의 환자에서 CT상 중 페암과 유사하게 보인 10명의 환자(남 : 여 = 2 : 8, 평균 연령 68세, 연령 분포: 58-79세)를 대상으로 하였다. 전 예에서 CT(n=10)검사와 MRI(n=10) 검사를 시행하였고 경피적 조직생검(n=1)은 1예에서 시행하였다. 조영증강 없이 축상 T1 강조영상(600/30/3, repetition time/echo time/excitation)과 T2 강조영상(3500/99/4)에서 종괴, 무기폐와 림프절의 신호강도를 2명의 방사선과 전문의가 합의에 의해 후향적으로 분석하였다. 결과 : CT 소견은 4명에서는 종괴로, 4명에서는 무기폐로, 2명에서는 기관지벽 비후였다. 전 예에서 기관지 탄분 섬유화증의 특징인 종격동 림프절은 커져 있었다. 종괴는 T1 강조영상과 T2 강조영상에서 모두 저 신호강도로 보였다. 무기페는 T1 강조영상에서 중등도 신호 강도로, T2 강조영상에서 저 신호강도로 보였다. 림프절은 9명의 환자에서 T1 과 T2 강조영상에서 저 신호 강도로 보였다. 한명의 환자에서 T2 강조영상에서 림프절이 중심부는 고 신호강도로, 주변부는 저 신호강도로 보였다. 결론 : 폐암과 유사하게 보인 기관지 탄분 섬유화증환자에서 종괴, 무기폐와 림프절은 T2 강조영상에서 주로 저 신호강도로 보여 폐암과의 감별에 자기공명영상이 도움이 될 것으로 생각한다.

  • PDF