• Title/Summary/Keyword: CT-reconstruction

Search Result 474, Processing Time 0.024 seconds

Usefulness of DFOV Changes in Pediatric PET/CT Image Reconstruction (PET/CT에서 소아환자 영상 재구성 시DFOV 변화의 유용성)

  • Choi, Sung-Wook;Choi, Choon-Ki;Lee, Kyoo-Bok;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.171-175
    • /
    • 2008
  • Purpose: There have been something difficulties in locating focuses and quantitative analysis in case of pediatric patients because of the relatively small body compared to adults. This author of this study, therefore, evaluated the usefulness of DFOV (Display Field Of View) according to its changes in PET/CT image reconstruction by means of the phantom experiment and pediatric patients examination. Materials & Methods: 0.023 MBq/cc of $^{18}F$-FDG was put into the uniform NU2-94 phantom, and then emission scan was acquired for 10 minutes. For reconstruction, DFOV values were changed to 50, 45, 40, 35, 30, and 25 cm respectively. As for patient images, 20 patients who were diagnosed as the one or suspicion of the children tumor are targeted from Oct 2007 to Jan 2008. For image reconstruction, 50 cm was the basis of DFOV, and the value was adjusted to DFOV 45 cm to 25 cm respectively. In the phantom and the reconstruction image of pediatric patients, the changes in pixel size and $SUV_{max}$ according to DFOV changes were analyzed. Results: As DFOV decreased to 50, 45, 40, 35, 30, and 25 cm by means of the phantom, the pixel size was changed to 3.906, 3.515, 3.125, 2.734, 2.343, and 1.953 mm respectively. Besides, as a result of reconstruction DFOV in images of pediatric patients to 50, to 25 cm, the different values of $SUV_{max}$ are shown as 3.3, 7.3, 12, 14, 18% and 2.6, 4.3, 5.0, 7.0, 10.0% on respectively when 50 cm was the standard. Conclusion: In $SUV_{max}$ using the phantom, as DFOV decreased every 5 cm, the mean value gradually increased. With 50 cm as the standard, the increase rates were 3.7, 6.5, 11.2, 19.5, and 32.1% respectively. As for pediatric patients image too, as DFOV decreased, the rates increased as in the phantom experiment. In image reconstruction, since DFOV decrease regardless of matrix size change reduced the pixel size, the image quality can be improved. This would be more useful than reconstruction and enlarge images of pediatric patients in the same way of examining adults. However, when the value of 35 cm DFOV was applied, this may result in truncated artifact, and thus the application should be properly controlled. Change of DFOV may produce better image for pediatric patients, but changes of SUV values according to DFOV change should be considered in reading.

  • PDF

Cardiac CT for Measurement of Right Ventricular Volume and Function in Comparison with Cardiac MRI: A Meta-Analysis

  • Jin Young Kim;Young Joo Suh;Kyunghwa Han;Young Jin Kim;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.450-461
    • /
    • 2020
  • Objective: We performed a meta-analysis to evaluate the agreement of cardiac computed tomography (CT) with cardiac magnetic resonance imaging (CMRI) in the assessment of right ventricle (RV) volume and functional parameters. Materials and Methods: PubMed, EMBASE, and Cochrane library were systematically searched for studies that compared CT with CMRI as the reference standard for measurement of the following RV parameters: end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), or ejection fraction (EF). Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and correlation coefficient (r) between CT and CMRI. Heterogeneity was also assessed. Subgroup analyses were performed based on the probable factors affecting measurement of RV volume: CT contrast protocol, number of CT slices, CT reconstruction interval, CT volumetry, and segmentation methods. Results: A total of 766 patients from 20 studies were included. Pooled bias and LOA were 3.1 mL (-5.7 to 11.8 mL), 3.6 mL (-4.0 to 11.2 mL), -0.4 mL (5.7 to 5.0 mL), and -1.8% (-5.7 to 2.2%) for EDV, ESV, SV, and EF, respectively. Pooled correlation coefficients were very strong for the RV parameters (r = 0.87-0.93). Heterogeneity was observed in the studies (I2 > 50%, p < 0.1). In the subgroup analysis, an RV-dedicated contrast protocol, ≥ 64 CT slices, CT volumetry with the Simpson's method, and inclusion of the papillary muscle and trabeculation had a lower pooled bias and narrower LOA. Conclusion: Cardiac CT accurately measures RV volume and function, with an acceptable range of bias and LOA and strong correlation with CMRI findings. The RV-dedicated CT contrast protocol, ≥ 64 CT slices, and use of the same CT volumetry method as CMRI can improve agreement with CMRI.

Application of Dual Tree Complex Wavelet for Performance Improvement of CT Images (CT 영상의 화질개선을 위한 이중트리복합웨이블릿의 적용)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.941-946
    • /
    • 2019
  • Computed tomography (CT) has been increasing in frequency and indications for use in clinical diagnosis and treatment decisions. Multidetector CT has the advantage of shortening the inspection time and obtaining a high resolution image compared to a single detector CT, but has been pointed out the disadvantage of increasing the radiation exposure. In addition, when the low tube voltage is used to reduce the exposure dose in the CT, noise increases relatively. In the existing method, the method of finding the optimal image quality using the method of adjusting the parameters of the image reconstruction method is not a fundamental measure. In this study, we applied a double-tree complex wavelet algorithm and analyzed the results to maintain the normal signal and remove only noise. Experimental results show that the noise is reduced from 8.53 to 4.51 when using a complex oriented 2D method with 100kVp and 0.5sec rotation time. Through this study, it was possible to remove the noise and reduce the patient dose by using the optimal noise reduction algorithm. The results of this study can be used to reduce the exposure of patients due to the low dose of CT.

Accuracy and Usefulness of Volume Measurement using CT and Ultrasound Scan Data (CT 및 초음파 스캔 데이터를 이용한 체적 측정의 정확도 및 유용성)

  • Kim, Hyeon-Ju;Lee, Hoo-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.289-294
    • /
    • 2022
  • In this study, the accuracy and usefulness of volume measurement were investigated as a phantom experiment using CT and USG scan data and a clinical trial using patient scan data. As a result, there was no significant difference between the volume of the actual round phantom of various volumes for both the CT and ultrasound devices (p>0.05). As a result of statistical analysis, it was analyzed that there was no significant difference (p>0.05). Clinical application of this result requires more clinical trials, but if a CT or ultrasound device is selected and applied in consideration of patient radiation exposure, the examiner's scanning technology, and CT reconstruction experience, the basic data in terms of the usefulness of volume measurement using CT scan image is considered to have application value.

Advantage of Middle Meatal Antrostomy in Transnasal Endoscopic Reconstruction of Medial Orbital Blow-out Fracture (안와내벽외향골절의 비내시경적정복술에 있어 중비도상악동절개술의 장점)

  • Kim, Soon Heum;Lee, Soo Hyang;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il;Kim, Bo Hyung
    • Archives of Plastic Surgery
    • /
    • v.34 no.6
    • /
    • pp.735-740
    • /
    • 2007
  • Purpose: Blowout fracture is an outward fracture of the orbital wall. That usually occurs at inferior or medial wall of the orbit. The main pathophysiology is high intraocular pressure derived from impact of trauma. Among the four orbital wall, the medial wall is thinnest and most vulnerable to trauma. Many kinds of methods were introduced for correction of medial orbital wall fracture. Recently, transnasal endoscopic reconstruction methods were widely used. Endoscopic methods had many advantages. However, we experienced some cases of postoperative maxillary sinusitis. This study was planned to find out the effectiveness of middle meatal antrostomy after endoscopic reconstruction of medial orbital wall fracture. Methods: This study was retrospective analysis of 28 patients who underwent transnasal endoscopic repair of medial orbital wall fracture. The 18 male and 10 female patients were ranged from 17 to 57 years of age(mean, 30.9 years). Among 28 patients, randomly selected 17 patients underwent middle meatal antrostomy as additional procedure by the same surgeon. After at least 12 months of follow-up period, we examined the nasal symptom, endoscopic and CT findings. Results: One patient complained of nasal obstruction in middle meatal antrostomy group and four patients complained nasal symptoms in non middle meatal antrostomy group. On the endoscopic findings, three patients of non middle meatal antrostomy group had continuous nasal discharge. But middle meatal antrostomy group had no abnormal endoscopic findings. The abnormal CT finding(abnormal mucosal hypertrophy) were detected in four patient of non middle meatal antrostomy group. There were no abnormal CT findings in middle meatal antrostomy group. The data were statistically significant at comparative study. Conclusion: Authors think that the middle meatal antrostomy has some advantages as a additional procedure of endoscopic reconstruction of medial orbital wall fracture. Especially, it is good at preventing postoperative maxillary sinusitis. But, more larger group and strict application of disease entity are need for correct evaluation of middle meatal antrostomy effect.

Analysis of Image Distortion by Mandibular Arch Form in Cone Beam CT and Panoramic Image (Cone Beam형 CT와 파노라마 영상에서 하악궁의 영상 왜곡 분석)

  • Jeong, Cheonsoo;Lee, Geeheun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.301-305
    • /
    • 2013
  • This thesis intends to analyze tooth distortion by mandibular arch form by reproducing existing panorama image and reconstructed panorama image of Cone Beam CT data with the three-dimensional computer program. The diameter of tooth measured in Cone Beam CT's cross-section image and reconstructed panorama was synchronized without any big change from incisors to posteriors. But, panorama showed serious distortion as going to posteriors after showing a little distortion in incisors. The panorama reconstructed for patients' individual arch showed reduced distortion than panoramas used generally. In addition, panorama showed serious distortion from incisors to posteriors and it means that distortion is reduced in reconstructed panorama.

A Study on Stereo Visualization of the X-ray Scanned Image Based on Volume Reconstruction (볼륨기반 X-선 스캔영상의 3차원 형상화 연구)

  • Lee, Nam-Ho;Park, Soon-Yong;Hwang, Young-Gwan;Park, Jong-Won;Lim, Yong-Gon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.7
    • /
    • pp.1583-1590
    • /
    • 2011
  • As the existing radiation scanning systems use 2-dimensional radiation scanned images, the low accuracy has been pointed out as a problem of it. This research analyzes the applicability of the stereo image processing technique to X-ray scanned images. Two 2-dimensional radiation images which have different disparity values are acquired from a newly designed stereo image acquisition system which has one additional line sensor to the conventional system. Using a matching algorithm the 3D reconstruction process which find the correspondence between the images is progressed. As the radiation image is just a density information of the scanned object, the direct application of the general stereo image processing techniques to it is inefficient. To overcome this limitation of a stereo image processing in radiation area, we reconstruct 3-D shapes of the edges of the objects. Also, we proposed a new volume based 3D reconstruction algorithm. Experimental results show the proposed new volume based reconstruction technique can provide more efficient visualization for cargo inspection. The proposed technique can be used for such objects which CT or MRI cannot inspect due to restricted scan environment.

Staged reconstruction of a chronically infected large skull defect using free tissue transfer and a patient-specific polyetheretherketone implant

  • Moon, Seung Jin;Jeon, Hong Bae;Kim, Eui Hyun;Lew, Dae Hyun;Kim, Yong Oock;Hong, Jong Won
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.5
    • /
    • pp.309-314
    • /
    • 2020
  • Reconstructions of extensive composite scalp and cranial defects are challenging due to high incidence of postoperative infection and reconstruction failure. In such cases, cranial reconstruction and vascularized soft tissue coverage are required. However, optimal reconstruction timing and material for cranioplasty are not yet determined. Herein, we present a large skull defect with a chronically infected wound that was not improved by repeated debridement and antibiotic treatment for 3 months. It was successfully treated with anterolateral thigh (ALT) free flap transfer for wound salvage and delayed cranioplasty with a patient-specific polyetheretherketone implant. To reduce infection risk, we performed the cranioplasty 1 year after the infection had resolved. In the meantime, depression of ALT flap at the skull defect site was observed, and the midline shift to the contralateral side was reported in a brain computed tomography (CT) scan, but no evidence of neurologic deterioration was found. After the surgery, sufficient cerebral expansion without noticeable dead-space was confirmed in a follow-up CT scan, and there was no complication over the 1-year follow-up period.

Comparison of the second and third intercostal spaces regarding the use of internal mammary vessels as recipient vessels in DIEP flap breast reconstruction: An anatomical and clinical study

  • Seong, Ik Hyun;Woo, Kyong-Je
    • Archives of Plastic Surgery
    • /
    • v.47 no.4
    • /
    • pp.333-339
    • /
    • 2020
  • Background The purpose of this study was to compare the anatomical features of the internal mammary vessels (IMVs) at the second and third intercostal spaces (ICSs) with regard to their use as recipient vessels in deep inferior epigastric artery perforator (DIEP) flap breast reconstruction. Methods A total of 38 consecutive DIEP breast reconstructions in 36 patients were performed using IMVs as recipient vessels between March 2017 and August 2018. The intraoperative findings and postoperative complications were analyzed. Anatomical analyses were performed using intraoperative measurements and computed tomography (CT) angiographic images. Results CT angiographic analysis revealed the mean diameter of the deep inferior epigastric artery to be 2.42±0.27 mm, while that of the deep inferior epigastric vein was 2.91±0.30 mm. A larger mean vessel diameter was observed at the second than at the third ICS for both the internal mammary artery (2.26±0.32 mm vs. 1.99±0.33 mm, respectively; P=0.001) and the internal mammary vein (IMv) (2.52±0.46 mm vs. 2.05±0.42 mm, respectively; P<0.001). Similarly, the second ICS was wider than the third (18.08±3.72 mm vs. 12.32±2.96 mm, respectively; P<0.001) and the distance from the medial sternal border to the medial IMv was greater (9.49±2.28 mm vs. 7.18±2.13 mm, respectively; P<0.001). Bifurcations of the IMv were found in 18.4% of cases at the second ICS and in 63.2% of cases at the third ICS. Conclusions The IMVs at the second ICS had more favorable anatomic features for use as recipient vessels in DIEP flap breast reconstruction than those at the third ICS.

Use of 3D Printing Model for the Management of Fibrous Dysplasia: Preliminary Case Study

  • Choi, Jong-Woo;Jeong, Woo Shik
    • Journal of International Society for Simulation Surgery
    • /
    • v.3 no.1
    • /
    • pp.36-38
    • /
    • 2016
  • Fibrous dysplasia is a relatively rare disease but the management would be quite challenging. Because this is not a malignant tumor, the preservation of the facial contour and the various functions seems to be important in treatment planning. Until now the facial bone reconstruction with autogenous bone would be the standard. Although the autogenous bone would be the ideal one for facial bone reconstruction, donor site morbidity would be the inevitable problem in many cases. Meanwhile, various types of allogenic and alloplastic materials have been also used. However, facial bone reconstruction with many alloplastic material have produced no less complications including infection, exposure, and delayed wound healing. Because the 3D printing technique evolved so fast that 3D printed titanium implant were possible recently. The aim of this trial is to try to restore the original maxillary anatomy as possible using the 3D printing model, based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. And we molded Titanium mesh to reconstruct three-dimensional maxillary structure during the operation. This prefabricated Titanium-mesh implant was then inserted onto the defected maxilla and fixed. Three dimensional printing technique of titanium material based on the computer simulation turned out to be successful in this patient. Individualized approach for each patient could be an ideal way to restore the facial bone.