Imaging and Clinical Data Distinguish Lymphadenopathy-First-Presenting Kawasaki Disease from Bacterial Cervical Lymphadenitis

  • Park, Byung Sung;Bang, Myung Hoon;Kim, Sung Hye
    • Journal of Cardiovascular Imaging
    • /
    • v.26 no.4
    • /
    • pp.238-246
    • /
    • 2018
  • BACKGROUND: Kawasaki disease (KD) sometimes presents with only fever and cervical lymphadenopathy before other clinical signs materialize. This lymphadenopathy-first-presenting Kawasaki disease (LKD) may be misdiagnosed as bacterial cervical lymphadenitis (BCL). We investigated characteristic imaging and clinical data for factors differentiating LKD from BCL. METHODS: We compared imaging, clinical, and laboratory data of patients with KD and BCL. We included patients admitted to a single tertiary center between January 2015 and July 2018. RESULTS: We evaluated data from 51 patients with LKD, 63 with BCL, and 218 with typical KD. Ultrasound imaging revealed multiple enlarged lymph nodes in both LKD and BCL patients. On the other hand, computed tomography (CT) showed more abscesses in patients with BCL. Patients with LKD were younger and showed higher systemic and hepatobiliary inflammatory markers and pyuria than BCL patients. In multivariable logistic regression, younger age and higher C-reactive protein (CRP) retained independent associations with LKD. A comparison of the echocardiographic findings in LKD and typical KD showed that patients with LKD did not have a higher incidence of coronary artery abnormalities (CAA). CONCLUSIONS: LKD patients tend to have no abscesses on CT and more elevated systemic hepatobiliary inflammatory markers and pyuria compared to BCL patients. The absence of abscess on CT, younger age, and elevated CRP were the most significant variables differentiating LKD from BCL. There was no difference in CAA between LKD and typical KD.

The Analysis of CT Number Rate of Change of Applying The Iterative Metallic Artifact Reduction Algorithm for CT Reconstruction Image (Iterative Metallic Artifact Reduction 알고리즘 적용 CT 재구성영상의 CT Number 변화율 분석)

  • Kim, Hyeonju;Yoon, Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.84-91
    • /
    • 2017
  • This study was performed using Somatom Definition Flash (Siemens, Enlarge, Germany) and GE 64-MDCT (Discovery 750 HD, GE HEALTHCARE, Milwaukee, USA.) using high-density medical materials that (are indispensable to?) computed tomography. We analyzed quantitatively the rate of change of the CT number of the CT reconstruction images by means of the IMAR and MAR algorithms using the phantom images acquired after scanning and previously captured raw data images. As a result, it was shown that the IMAR and MAR algorithms provided if ferent phantom images in the case of all medical high-density materials (p <0.05). The black streak artifacts were analyzed using the MAR and IMAR algorithms to determine if they corresponded to stainless steel materials (p>0.05). Also, it was found that the application of the IMAR algorithm affects the attenuation deviation, because there is a change in the image CT number compared to that before. The results suggest that, in the future, after the implant procedure, it would be useful to observe the surgical site and surrounding tissues during follow-up CT scans.

A Study on Elbow Phantom Production and Usability Evaluation by Adjusting Infill Density using 3D Printing (3D 프린팅을 사용한 Infill 조절에 따른 Elbow 팬텀 제작 및 유용성 평가에 관한 연구)

  • Myung-In Kim;Seung-Ho Ji;Hyun-Seop Wi;Dae-Won Lee;Hui-Min Jang;Myeong-Seong Yun;Dong-Kyoon Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.929-937
    • /
    • 2023
  • Human equivalent phantoms manufactured using 3D printers are cheaper and can be manufactured in a short time than conventional human phantoms. However, many phantoms are manufactured with less than 100 % of Infill Density, one of the 3D printer output setting variables. Therefore, this study compared the Bone Phantom CT number, which differs from the ratio of five Infill Density produced using a 3D printer, to the CT number of the actual human body Bone. In addition, the usefulness of the manufactured phantom was evaluated by producing a 100 % elbow joint phantom with Infill Density and setting the Infill Density to 100 % through CT number comparison for each tissue on computed tomography (CT). As a result, the Bone Phantom printed with 100 % Infill Density did not show the most statistically significant difference from the CT number value of the actual human Bone, and the CT number of each tissue did not show a statistically significant difference from the CT number value of each tissue of the actual human elbow joint.

Appendiceal Visualization on 2-mSv CT vs. Conventional-Dose CT in Adolescents and Young Adults with Suspected Appendicitis: An Analysis of Large Pragmatic Randomized Trial Data

  • Jungheum Cho;Youngjune Kim;Seungjae Lee;Hooney Daniel Min;Yousun Ko;Choong Guen Chee;Hae Young Kim;Ji Hoon Park;Kyoung Ho Lee;LOCAT Group
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.413-425
    • /
    • 2022
  • Objective: We compared appendiceal visualization on 2-mSv CT vs. conventional-dose CT (median 7 mSv) in adolescents and young adults and analyzed the undesirable clinical and diagnostic outcomes that followed appendiceal nonvisualization. Materials and Methods: A total of 3074 patients aged 15-44 years (mean ± standard deviation, 28 ± 9 years; 1672 female) from 20 hospitals were randomized to the 2-mSv CT or conventional-dose CT group (1535 vs. 1539) from December 2013 through August 2016. A total of 161 radiologists from 20 institutions prospectively rated appendiceal visualization (grade 0, not identified; grade 1, unsure or partly visualized; and grade 2, clearly and entirely visualized) and the presence of appendicitis in these patients. The final diagnosis was based on CT imaging and surgical, pathologic, and clinical findings. We analyzed undesirable clinical or diagnostic outcomes, such as negative appendectomy, perforated appendicitis, more extensive than simple appendectomy, delay in patient management, or incorrect CT diagnosis, which followed appendiceal nonvisualization (defined as grade 0 or 1) and compared the outcomes between the two groups. Results: In the 2-mSv CT and conventional-dose CT groups, appendiceal visualization was rated as grade 0 in 41 (2.7%) and 18 (1.2%) patients, respectively; grade 1 in 181 (11.8%) and 81 (5.3%) patients, respectively; and grade 2 in 1304 (85.0%) and 1421 (92.3%) patients, respectively (p < 0.001). Overall, undesirable outcomes were rare in both groups. Compared to the conventional-dose CT group, the 2-mSv CT group had slightly higher rates of perforated appendicitis (1.1% [17] vs. 0.5% [7], p = 0.06) and false-negative diagnoses (0.4% [6] vs. 0.0% [0], p = 0.01) following appendiceal nonvisualization. Otherwise, these two groups were comparable. Conclusion: The use of 2-mSv CT instead of conventional-dose CT impairs appendiceal visualization in more patients. However, appendiceal nonvisualization on 2-mSv CT rarely leads to undesirable clinical or diagnostic outcomes.

Registration of 3D CT Data to 2D Endoscopic Image using a Gradient Mutual Information based Viewpoint Matching for Image-Guided Medialization Laryngoplasty

  • Yim, Yeny;Wakid, Mike;Kirmizibayrak, Can;Bielamowicz, Steven;Hahn, James
    • Journal of Computing Science and Engineering
    • /
    • v.4 no.4
    • /
    • pp.368-387
    • /
    • 2010
  • We propose a novel method for the registration of 3D CT scans to 2D endoscopic images during the image-guided medialization laryngoplasty. This study aims to allow the surgeon to find the precise configuration of the implant and place it into the desired location by employing accurate registration methods of the 3D CT data to intra-operative patient and interactive visualization tools for the registered images. In this study, the proposed registration methods enable the surgeon to compare the outcome of the procedure to the pre-planned shape by matching the vocal folds in the CT rendered images to the endoscopic images. The 3D image fusion provides an interactive and intuitive guidance for surgeon by visualizing a combined and correlated relationship of the multiple imaging modalities. The 3D Magic Lens helps to effectively visualize laryngeal anatomical structures by applying different transparencies and transfer functions to the region of interest. The preliminary results of the study demonstrated that the proposed method can be readily extended for image-guided surgery of real patients.

The diffusion and policy options of the diagnostic imaging technologies in Korea (의사결정나무 분석을 사용한 고가의료장비의 다빈도 사용 특성 분석)

  • Choi, Yoon Jung;Kwak, Minjung;Yoon, Min
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.1
    • /
    • pp.179-185
    • /
    • 2015
  • The cost of advanced medical technologies is commonly considered to be a major factor in the overall escalation of expenditures on health. The use of computed tomography (CT) scanning has increased dramatically over the past decade. CT has been rapidly adopted, despite their high cost. The aim of this study is to analysis the increasing factor of the frequency of the CT, using the decision tree model. Finally, we propose the effective policy option of diagnostic imaging technology in Korea.

Volumetric changes in the lumpectomy cavity during whole breast irradiation after breast conserving surgery

  • Cho, Heung-Lae;Kim, Cheol-Jin
    • Radiation Oncology Journal
    • /
    • v.29 no.4
    • /
    • pp.277-282
    • /
    • 2011
  • Purpose: This study was performed to evaluate the change in the lumpectomy cavity volumes before and after whole breast radiation therapy (WBRT) and to identify factors associated with the change of volume. Materials and Methods: From September 2009 to April 2010, the computed tomography (CT) simulation data from 70 patients obtained before and after WBRT was evaluated. The lumpectomy cavity volumes were contoured based on surgical clips, seroma, and postoperative changes. Significant differences in the data from pre-WBRT CT and post-WBRT CT were assessed. Multiple variables were examined for correlation with volume reduction in the lumpectomy cavity. Results: The mean and median volume reduction in the lumpectomy cavity after WBRT were 17.6 $cm^3$ and 16.1 $cm^3$, respectively with the statistical significance (p < 0.001). The volume reduction in the lumpectomy cavity was inversely correlated with time from surgery to radiation therapy (R = 0.390). The presence of seroma was significantly associated with a volumetric change in the lumpectomy cavity after WBRT (p = 0.011). Conclusion: The volume of lumpectomy cavity reduced significantly after WBRT. As the time from surgery to the start ot WBRT increased, the volume reduction in the lumpectomy cavity during WBRT decreased. A strong correlation was observed between the presence of seroma and the reduced volume. To ensure appropriate coverage and to limit normal tissue exposure during boost irradiation in patients who has seroma at the time of starting WBRT, repeating CT simulation at boost planning is suggested.

Role of F-18 FDG PET or PET/CT in the Evaluation of Gastric Cancer (위암 평가에 있어 F-18 FDG PET 또는 PET/CT의 역할)

  • Yun, Mi-Jin
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.141-147
    • /
    • 2006
  • PET detects only less than 50% of early gastric cancer and 62-98% of advanced gastric cancer. Therefore, mass screening programs are recommended for all adults over the age of 40 for early detection and early treatment of gastric cancer through endoscopy or various radiological tests. The most important step after being diagnosed with gastric cancer is accurate staging, which mainly evaluates tumor resectability to avoid unnecessary surgery. Important factors that affect tumor resectability are whether the tumor can be separated from adjacent organs or important blood vessels, the extent of lymph node metastasis, presence of peritoneal metastasis, or distant organ metastasis. To evaluate the extent of local tumor invasion, anatomical imaging that has superior spatial resolution is essential. There are a few studies on prognostic significance of FDG uptake with inconsistent results between them. In spite of lower sensitivities for lymph node staging, the specificities of CT and PET are very high, and the specificity for PET tends to be higher than that for CT. Limited data published so far show that PET seems less useful in the detection of lung and bone metastasis. In the evaluation of pleural or peritoneal metastasis, PET seems very specific but insensitive as well. When FDG uptake of the primary tumor is low, the distant metastasis is also known to show low FDG uptake reducing its detection. There are only a few data available in the evaluation of recurrence detection and treatment response using FDG PET.

Comparison of Analysis Results According to Heterogeneous or Homogeneous Model for CT-based Focused Ultrasound Simulation (CT 영상 기반 집속 초음파 시뮬레이션 모델의 불균질 물성과 균질 물성에 따른 모델 분석 결과 비교)

  • Hyeon, Seo;Eun-Hee, Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.369-374
    • /
    • 2022
  • Purpose: Focused ultrasound is an emerging technology for treating the brain locally in a noninvasive manner. In this study, we have investigated the influence of skull properties on simulating transcranial pressure field. Methods: A 3D computational model of transcranial focused ultrasound was constructed using female and male CT data to solve for intracranial pressure. For heterogeneous model, the acoustic properties were calculated from CT Hounsfield units based on a porosity. The homogeneous model assigned constant acoustic properties for the single-layered skull. Results: A computational model was validated against empirical data. The homogeneous models were then compared with the heterogeneous model, resulted in 10.87% and 7.19% differences in peak pressure for female and male models respectively. For the focal volume, homogeneous model demonstrated more than 94% overlap compared with the heterogeneous model. Conclusion: Homogeneous model can be constructed using MR images that are commonly used for the segmentation of the skull. We propose the possibility of the homogeneous model for the simulating transcranial pressure field owing to comparable focal volume between homogeneous model and heterogeneous model.

The Effect of Intravenous Contrast on SUV Value in $^{18}F$-FDG PET/CT using Diagnostic High Energy CT (진단용 고선량 CT를 이용한 $^{18}F$-FDG PET/CT 촬영시 정맥 조영제가 SUV 값에 미치는 영향)

  • Jeong, Young-Jin;Kang, Do-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.169-176
    • /
    • 2006
  • Purpose: According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. Materials & Methods: The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT-120 kVp, 130 mAs) scan. Then contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET omission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in ail patients. Also pathologic lesions were investigated. Results: There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p<0.00)). The maxSUV was $1.1{\pm}0.5$ in PET images with CECT-corrected attenuation and $1.0{\pm}0.5$ in PET images with NCCI-corrected attenuation. The limit of agreement was $0.1{\pm}0.3$ in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 & segment 8 of the liver and spleen (p<0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p<0.001). The maxSUV was $4.7{\pm}2.0$ in PET images with CECT-corrected attenuation and $4.4{\pm}2.0$ in PET images with NCCT-corrected attenuation. The limit of agreement was $0.4{\pm}0.8$ in Bland-Altman analysis. Conclusion: Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of agreement. So there was no significant effect to clinical interpretation for PET images that were corrected attenuation with high dose CT using IV contrast.