• Title/Summary/Keyword: CT data

Search Result 1,288, Processing Time 0.03 seconds

A Comparison Analysis of CT Effective Dose and Image Quality according to Abdominal Diameter (복부직경에 따른 CT유효선량 및 화질변화 비교 분석)

  • Yoon, Joon;Kim, Hyeonju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.821-826
    • /
    • 2018
  • This study was performed randomly from all the patients who visited the University Hospital in Gyeonggi-do from January 1, 2018 to June 30, 2018 for the abdominal CT scan. We divided the patients into three groups and evaluated the extent of effective dose and image quality according to the area of the abdominal CT image. As a result, the effective dose was 7.34 mSv in the average area group, 8.39 mSv in the average area and 5.89 mSv in the average area. For the analysis of image quality, ROI was plotted in the same three regions according to the abdominal area. As a result, CT values were significantly different in the abdominal area classified into 3 groups (p <0.05). The results of this study can be used as a basic data for the development of a protocol that can be applied in actual clinical practice. It is thought that it can help to reduce the image quality and the radiation dose.

Construction of 3D Geometric Surface Model from Laminated CT Images for the Pubis (치골 부위의 CT 적층 영상을 활용한 3D 기하학적 곡면 모델로의 가공)

  • Hwang, Ho-Jin;Mun, Du-Hwan;Hwang, Jin-Sang
    • Korean Journal of Computational Design and Engineering
    • /
    • v.15 no.3
    • /
    • pp.234-242
    • /
    • 2010
  • 3D CAD technology has been extended to a medical area including dental clinic beyond industrial design. The 2D images obtained by CT(Computerized Tomography) and MRI(Magnetic Resonance Imaging) are not intuitive, and thus the volume rendering technique, which transforms 2D data into 3D anatomic information, has been in practical use. This paper has focused on a method and its implementation for forming 3D geometric surface model from laminated CT images of the pubis. The implemented system could support a dental clinic to observe and examine the status of a patient's pubis before implant surgery. The supplement of 3D implant model would help dental surgeons settle operation plans more safely and confidently. It also would be utilized with teaching materials for a practice and training.

Unusual Brain Computed Tomography Artifact in Cerebellum Mimicking Hemorrhage: A Case Report (뇌 CT에서 출혈로 오인된 소뇌의 허상: 증례보고)

  • Lee, Jihun;Eom, Ki Seong;Kim, Tae-Young
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.195-197
    • /
    • 2015
  • Artifacts can seriously degrade the quality of computed tomography (CT) images, sometimes to the point of making them diagnostically unusable. Here, we report an unusual CT artifact that could have resulted in the misdiagnosis of a hyperdense hemorrhagic lesion in a 55-year-old man. The author recommend that when hemorrhagic lesion in posterior fossa is suggested on CT, the physician should carefully consider all patient-related clinical data prior to considering surgical intervention or a biopsy. Cranial magnetic resonance imaging (MRI) can help in preventing the misdiagnosis as hemorrhage of CT scan.

  • PDF

3D Reconstructed Image of Neck Mass to Improve Patient's Understanding (경부 종물 환자의 이해도 개선을 위한 3차원 재건 영상의 활용)

  • Yoo, Young-Sam
    • Korean Journal of Head & Neck Oncology
    • /
    • v.26 no.2
    • /
    • pp.193-197
    • /
    • 2010
  • Objectives : Patients with neck tumor and their family need every information about the disease. Especially, the size and location are confusing with verbal information. With the aid of CT, the problem had some answer, but it needs some medical education. We would like to know the usefullness of 3D reconstructed images in patient education about the disease. Material and Methods : Neck CT data were collected from 10 patients with various neck tumors and converted to 3D reconstructed images. Understanding of the patients about the size and location of tumors were rated from questionaires using axial CT images and 3D images. Results : Understanding score about 3D images were greater than that of CT images(p<0.006). Conclusion : 3D reconstructed images of CT could give the patients more real visual information about the disease.

An Enhanced Compensation Algorithm for the CT Saturation Using Interpolation-based LSQ(Least Square) Fitting Method (내삽법 기반의 최소자승법을 이용한 개선된 CT 포화 복원 알고리즘)

  • Ryu, Ki-Chan;Kang, Sang-Hee;Lee, Bong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.14-15
    • /
    • 2006
  • A saturation of magnetic flux in the core may occur when a large primary current flows when the iron-cored current transformer is used. This saturation makes the distorted secondary current of the CT. the distorted secondary current may cause the mal-operation or operation time delay of protective relays. CT compensation algorithm using The LSQ(Least Square) fitting method has a problem. It needs to acquire enough data for executing this algorithm without an error. In this paper, an enhanced algorithm using interpolation based LSQ(Least Square) Fitting Method is proposed. The Lagrange Interpolation Method is used for the interpolation and CT is simulated by EMTP. The results show that the proposed algorithm can accurately compensate a distorted secondary current more than existing Algorithm when the saturation severely occurs.

  • PDF

Measurement of Deformation field in CT specimen using Laser speckle (레이저 스페클을 이용한 CT 시험편의 변형장 측정)

  • Jean, Moon-Chang;Kang, Ki-Ju
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.192-197
    • /
    • 2001
  • To obtain $A_2$ experimentally in the $J-A_2$ theory, deformation field on the lateral surface of a CT specimen was to be determined using Laser speckle method. The crack growth was measured using direct current potential drop method and most procedure of experimental and data reduction was performed according to ASTM Standard E1737-96. Laser speckle images during crack propagation were monitored by two CCD cameras to cancel the effect of rotation and translation of the specimen. An algorithm to pursue displacement of a point from each image was developed and successfully used to measure $A_2$ continuously as the crack tip was propagated. The effects of specimen thickness on J-R curve and $A_2$ were explored.

  • PDF

Sparse-View CT Image Recovery Using Two-Step Iterative Shrinkage-Thresholding Algorithm

  • Chae, Byung Gyu;Lee, Sooyeul
    • ETRI Journal
    • /
    • v.37 no.6
    • /
    • pp.1251-1258
    • /
    • 2015
  • We investigate an image recovery method for sparse-view computed tomography (CT) using an iterative shrinkage algorithm based on a second-order approach. The two-step iterative shrinkage-thresholding (TwIST) algorithm including a total variation regularization technique is elucidated to be more robust than other first-order methods; it enables a perfect restoration of an original image even if given only a few projection views of a parallel-beam geometry. We find that the incoherency of a projection system matrix in CT geometry sufficiently satisfies the exact reconstruction principle even when the matrix itself has a large condition number. Image reconstruction from fan-beam CT can be well carried out, but the retrieval performance is very low when compared to a parallel-beam geometry. This is considered to be due to the matrix complexity of the projection geometry. We also evaluate the image retrieval performance of the TwIST algorithm -sing measured projection data.

On the usefulness of RTS/CTS in wireless ad-hoc networks (무선 Ad-hoc 네트워크에서 RTS/CTS의 사용여부에 관한 연구)

  • Kim, Mo-Ses;Mo, Jeong-Hoon
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11a
    • /
    • pp.310-312
    • /
    • 2005
  • 무선 Ad-hoc 네트워크상에서 hidden node problem을 해결하기 위해 도입된 RTS/CTS의 사용여부는 네트워크의 처리량(throughput)에 영향을 미친다. 이는 RTS/CTS가 hidden node problem을 해결해주지만 거기에서 발생하는 overhead 때문에 처리량이 떨어질 수도 있기 때문이다. 기존 관련 연구에서는 RTS/CTS의 사용여부를 패킷의 크기에 따라 달리 해야 한다고 말하고 있다. 그리고 이를 구현하기 위해서 RTSThreshold라는 값을 사용하고 있다. 만약 이 값보다 패킷의 크기가 작으면 RTS/CTS는 사용 되지 않고, 만약 이 값보다 패킷의 크기가 크면 RTS/CTS가 사용된다. 이렇게 RTS/CTS의 사용여부를 결정해주는 RTSThreshold값을 결정하기 위해선 네트워크의 처리량에 영향을 줄 수 있는 모든 인자들을 고려해 보아야 할 것이다. 조사한 바에 의하면 이미 관련 연구에서 physical preamble의 크기, 노드의 수, 그리고 data rate와 RTSThreshold와의 관계를 연구 했었지만, 그밖에 네트워크의 처리량에 영향을 줄 수 있는 carrier sense range나 네트워크의 크기와의 관계는 연구가 되지 않았었다. 따라서 본 논문에서는 이 두가지 인자와 RISThreshold와의 관계를 살펴보고자 모의실험을 수행하였고 그 결과를 분석하였다. 두 인자가 어느 정도 RTSThreshold를 결정하는데 영향을 줄 것이라 예상했었지만, 실험 결과를 분석한 결과 carrier sense range나 네트워크의 크기는 RTSThreshold를 결정하는데 크게 영향을 주지 않는 것으로 나타났다.

  • PDF

Impacts of Critical Thinking Disposition and Nursing Work Environment on Nurses' Clinical Decision Making Abilities (간호사의 비판적 사고성향과 간호업무환경이 임상적 의사결정 능력에 미치는 영향)

  • Oh, Insook;Kim, Jeong-Hee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.22 no.3
    • /
    • pp.304-315
    • /
    • 2016
  • Purpose: The purpose of this study was to explore the relationships of critical thinking disposition (CT), nursing work environment (NWE), and clinical decision making ability among nurses. Methods: A cross-sectional, descriptive study design was conducted on 192 nurses who had worked for more than six months in five general hospitals. A self-reported questionnaire was used to collect data, which included demographics, CT, NWE, and clinical decision making ability. Results: The mean score of CT was 3.5. The highest score was on the objectivity of CT and the lowest on systematicity. The mean score of NWE was 2.3. The highest score was on the collegial nurse-physician relations of NWE and the lowest on the staffing and resource adequacy. The mean score of clinical decision making ability was 3.3. In hierarchical multiple regression, affecting factors on clinical decision making ability were CT and NWE. Conclusion: The findings showed that clinical decision making ability is associated with CT and NWE. To improve clinical decision making ability, it is important to improve CT. In addition, it should be considered to improve NWE where the nurses can make a decision with their job through critical thinking.

An Electronic Colon Cleansing Method using a Patient Colon CT Profile (환자 대장 CT 프로파일을 이용한 전자적 장세척 방법)

  • Kim, Han-Byul;Kim, Dong-Sung
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.8
    • /
    • pp.493-500
    • /
    • 2008
  • This paper proposes an electronic colon cleansing method using a patient CT profile for a virtual colonoscopy. The proposed method extracts the colon using cubic seeded region growing, and removes tagged materials adjacent to the colon. Residuals produced by a partial volume effect at the boundary of air-tagged material are deleted, and the removed soft tissue pixels due to a partial volume effect at the boundary of tagged material-soft tissue are recovered using a patient CT profile. The proposed method was applied to 16 virtual colonoscopy patient data sets, and produced promising results by a subjective evaluation of a radiologist and by a quantitative evaluation of a computer-aided diagnosis system.