• 제목/요약/키워드: CT contrast media

검색결과 84건 처리시간 0.029초

Influence of Iodinated Magnetic Resonance Contrast Media and Isotope 99mTc on Changes of Computed Tomography Number

  • Kim, Sang-Beom;Lee, Jin-Hyeok;Ahn, Jae-Ouk;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.302-307
    • /
    • 2015
  • The purpose of the study was to identify how isotope and magnetic resonance imaging (MRI) contrast media impact on noise to computed tomography (CT) examination. For the study, divide the phantoms to two groups: 1) saline, saline + different kinds of contrast agent without $^{99m}Tc$ administration; 2) $^{99m}Tc$ administration: saline, saline + different kinds of contrast agent with $^{99m}Tc$ administration. CT contrast agent was used for Iopamidol$^{(R)}$ and Dotarem. And MRI contrast agent was used for Primovist$^{(R)}$ and Gadovist$^{(R)}$. To obtain an image, we used CT scanner. With an obtained image, we set the $1cm^2$ region of interest in the middle of bottle to measure the noise and CT number. As a result, there was no difference in CT number before and after inserting $^{99m}Tc$ into all contrast media including Normal Saline. However, when it comes to Noise, there was a difference before and after inserting $^{99m}Tc$ into every contrast media except MRI contrast media such as Primovist$^{(R)}$ and Gadovist$^{(R)}$.

컴퓨터 단층촬영을 위한 요오드화 조영제 사용으로 인한 부작용 발생의 위험인자 연구 (Risk Factors for Adverse Reactions to Iodinated Contrast Media in Computed Tomography)

  • 강형림;이유정
    • 한국임상약학회지
    • /
    • 제26권1호
    • /
    • pp.40-45
    • /
    • 2016
  • Objective: The increasing use of imaging examinations such as computed tomography (CT) results in increased contrast media use, which increases contrast media-induced adverse reactions (AR). This study investigated the risk factors of ARs to nonionic iodinated contrast media. Methods: This study evaluated patients who were administered iodinated contrast media during CT scanning in Yeouido St. Mary's Hospital in Seoul, Korea in 2012. Among the subjects, those with contrast media-induced ARs were classified as the AR group. The control group included individuals without ARs who were selected through simple random sampling. The effects of sex, age, contrast media type and dose, CT region, previous contrast media administration, allergy history, and comorbidity were analyzed in the AR and control groups. Results: Multivariate logistic regression analyses were performed to evaluate the identified AR risk factors in 103 subjects in the AR group and 412 subjects in the control group. The results confirmed that the risk of developing ARs was significantly higher in females [odds ratio (OR): 2.206; 95% confidence interval (CI): 1.353-3.598], in individuals administered Iohexol (OR: 9.981; 95% CI: 2.361-42.193), in individuals with an allergy history (OR: 3.982; 95% CI: 1.742-9.101), and in individuals with comorbid asthma (OR: 6.619; 95% CI: 1.377-31.826). Most of the ARs were mild and immediate. Conclusion: In patients who were administered contrast media during CT scans, female gender, Iohexol use, allergy history, and asthma were risk factors for ARs. Therefore, special care is required for patients with such risk factors to prevent ARs.

전신 PET/CT 영상에서 조영제 영향의 보정 유.무에 따른 SUV 평가 (The Evaluation of SUV Using with and without Correction for Effect of Contrast Media in Whole Body PET/CT Imaging)

  • 남소라;손혜경;임한상;박훈희;조효민;이창래;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제17권4호
    • /
    • pp.246-251
    • /
    • 2006
  • 본 연구의 목적은 전신 PET/CT영상에서 조영제의 영향에 대한 보정 유 무가 SUV (standard uptake value)에 미치는 영향을 평가하는 것이었다. 영상획득은 GE DSTe PET/CT 시스템을 사용하였으며, 간질환(hepatocellular carcinoma, HCC)과 신장질환(renal cell carcinoma, RCC)이 있는 환자를 대상으로 하여 영상을 평가하였다. 영상 평가는 조영제에 의한 영향을 보정한 영상과 보정하지 않은 영상에서 각각 동일한 위치에 같은 크기의 관심영역을 설정한 후 각 관심영역으로부터 구한 SUV를 비교함으로써 수행하였다. HCC 환자의 경우 조영제에 의한 영향의 보정 유 무에 따른 평균 SUV의 차이는 $1.5{\pm}1.2%$이었고, 최대 4.3%의 SUV 차이를 나타내었다. RCC 환자의 경우 평균 SUV의 차이는 $1.0{\pm}0.9%$이었고, 최대 1.9%의 SUV 차이를 나타내었다. 조영제를 사용한 PET/CT 영상에서 조영제에 의한 영향을 보정하지 않았을 경우는 조영제에 의한 영향을 보정해준 경우에 비해 상대적으로 높은 SUV를 나타내었다. 본 연구의 결과는 HCC 환자와 RCC 환자의 경우 조영제에 의한 영향을 보정한 경우와 보정하지 않은 경우 SUV에 큰 차이를 보이지는 않았으나, 향후 보다 많은 수의 HCC 환자와 RCC 환자를 대상으로 한 추가적인 연구가 필요할 것이라고 생각한다. 또한 다른 질환을 가진 환자의 경우에 대해서도 조영제가 SUV에 미치는 영향을 평가하는 것은 매우 유용하리라 생각한다.

  • PDF

PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교 (A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT)

  • 이승재;박훈희;안샤론;오신현;남궁혁;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.235-240
    • /
    • 2008
  • PET/CT 검사의 사용 초기에 CT는 주로 감쇠보정(Attenuation Correction: AC)의 목적으로 사용되어졌지만, CT의 성능이 향상됨으로써 조영제를 이용한 CT검사를 진단에 반영하여 보다 진보된 진단적 가치를 가질 수 있게 되었다. 조영제의 사용이 없이도 CT를 판독할 수 있지만 병변의 정확한 범위를 확인하고 정상 구조물을 구별하는데 있어서 조영제의 사용은 판독자로 하여금 판독을 매우 용이하게 하는 도움을 줄 수 있다. 하지만, 그동안 PET/CT검사 시 조영제가 감쇠보정에 영향을 줄 수 있다는 논쟁으로 이견이 많았다. 40-140 keV 정도의 낮은 엑스선을 이용하는 CT영상에 비하여, 조영제를 사용한 CT영상에서는 조영제로 인해 감쇠가 많이 되지만 511 keV의 에너지를 가진 감마선은 조영제로 인해 거의 영향을 받지 않게 되고 이로 인해 감쇠보정 시 과보정을 하게 되어 PET영상에서 오류를 나타낼 수 있다는 의견이 보고되기도 하였다. 이와는 반대로 조영제가 감쇠보정에 과대평가를 가져올 수 있다는 의견과 과보정으로 인한 표준화섭취계수에 변화의 가능성은 있으나 결정적인 영향을 미치지 않는다는 의견도 제시되었다. 본 연구에서는 조영제의 영향이 SUV에 어떠한 영향을 미치는지에 대해서만 비교 평가하였다. 2007년 12월에서 2008년 6월 사이에 본원에서 PET/CT 검사를 시행한 환자 중 요오드 조영제에 대한 부작용이 없고 당뇨병이 없는 진행성 암 환자 30명을 대상으로 하였으며, DSTe (General Electric Healthcare, Milwaukee, MI, USA)를 사용하여, 각각의 환자는 조영제를 사용하지 않은 CT를 시행한 후 PET영상을 얻었고 그 후, 조영제를 사용한 CT검사를 하였다. 각각의 CT정보로 감쇠보정을 실시, 종류별로 PET영상을 획득하여, 각 영상에 동일한 관심영역(Region of Interests : ROIs)을 설정 후, SUV를 비교 하였다. 얻어진 두 가지 결과 값의 정량 분석의 비교를 위해서 대응표본 T-검정 (Paired t-test)을 사용하였다. 검사를 시행한 30명의 환자에게서 폐, 간, 심장의 $SUV_{max}$ 값과 $SUV_{mean}$값을 측정하여 총 180개 영역을 분석하였다. 조영제를 사용하기 전과 후를 비교하였을 때, 측정한 거의 모든 영역에서 조영 후의 $SUV_{max}$$SUV_{mean}$가 상승하였고 통계적으로도 유의한 것으로 나타났다(p value<0.05). 심장 영역에서 조영 전 보다 조영 후의 $SUV_{mean}$값이 증가된 것으로 나타났지만, 통계적으로 유의하게 나타나지는 않았다. 조영제를 사용한 CT영상의 SUV값이 과보정되어, 조영제를 사용하지 않은 CT의 SUV 보다 높게 나왔으나 기존의 보고된 논문에서는 이와 같은 결과는 실제 임상 판독에 있어서 큰 영향을 미치지 않는다고 보고되어 있다. 그러나 원발성병변의 진행을 알아보는 과정에서는 SUV의 작은 변동도 분명 영향을 줄 수 있으므로 간 영역과 같이 SUV의 변동이 다른 영역에 비해 상대적으로 큰 영역에서는 수치의 변화에 대한 주의가 요구 될 것으로 사료된다.

  • PDF

비글견의 간 CT 혈관조영상에서의 Iopamidol과 Iopromide, Iohexol 조명제의 비교실험 (A Comparison of Iopamidol with Iopromide and Iohexol Contrast Media in Hepatic CT Angiography in Beagle Dogs)

  • 정유철;임창윤;김경민;이성옥;정주현;장진화;오선경;송경진;윤정희;최민철
    • 한국임상수의학회지
    • /
    • 제23권2호
    • /
    • pp.129-132
    • /
    • 2006
  • The purpose of this paper was to compare the clinical efficacy of iopamidol and iopromide, iohexol nonionic contrast media in terms of their image quality in Beagle dogs with hepatic CT angiography and their application in veterinary clinics. With 9 Beagle dogs, contrast media of iopamidol (pamiray-$300^(R)$) and iopromide (ultravist-$300^(R)$, iohexol (omnipaque-$300^(R)$) were induced intravenously (600 mg I/kg, BW) and CT angiography was done under general anesthesia. CT scan included scout, pre-contrast and cine examinations. During CT angiography, peak HU (Hounsfield unit) and peak time were examined on each site (ROI; region of interest) of the aorta, caudal vena cava, potral vein and liver parenchyma. Any side effects were also examined. After experiments, it was found that there were no significant changes of HU and maximal enhancing time of each ROIs of aorta, caudal vena cava, portal vein and liver parenchyma between these contrast media. And any side effects were not noted. So it is concluded that iopamidol has similiar contrast enhancement like as iopromide and iohexol in hepatic angiography and and it is thought to be useful for evaluation of the abdominal organs by CT scan in veterinary clinics.

Influence of Iodinated Contrast Media and Paramagnetic Contrast Media on Changes in Uptake Counts of 99mTc

  • Cho, Jae-Hwan;Lee, Jin-Hyeok;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Jin;Moon, Deog-Hwan;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.248-254
    • /
    • 2014
  • The purpose of this study is to figure out how uptake counts of technetium ($^{99m}Tc$) among radioisotopes in the human body are affected if computed tomography (CT), magnetic resonance imaging (MRI) and isotope examination are performed consecutively. $^{99m}Tc$ isotope material, iodinated contrast media for CT and paramagnetic contrast media for magnetic resonance (MR) were used as experimental materials. First, $^{99m}Tc$ was added to 4 cc normal saline in a test tube. Then, 2 cc of CT contrast media such as $Iopamidol^{(R)}$ and $Dotarem^{(R)}$ were diluted with 2 cc normal saline, and 2cc of MRI contrast media such as $Primovist^{(R)}$ and $Gadovist^{(R)}$ were diluted with 2 cc normal saline. Each distributed contrast media was a total of 4 cc and included 10m Ci of $^{99m}Tc$. A gamma camera, a LEHR (Low energy high resolution) collimator and a pin-hole collimator were used for image acquisition. Image acquisition was repeated a total of 6 times and 120 frames were obtained and uptake counts of $^{99m}Tc$ were measured (from this procedure). In this study, as a result of measuring the uptake counts of $^{99m}Tc$ using the LEHR collimator, the uptake counts were less measured in all contrast media than normal saline as a reference. In particular, the lowest uptake counts were measured when $Gadovist^{(R)}$, contrast media for MRI, was used. However, the result of measuring the uptake counts of $^{99m}Tc$ using the pin-hole collimator showed higher uptake counts in all contrast media, except for $Iopamidol^{(R)}$, than normal saline as a reference. The highest uptake counts were measured particularly when $Primovist^{(R)}$, contrast media for MRI, was used. In performing the gamma camera examination using contrast media and $^{99m}Tc$, it is considered significant to check the changes in the uptake counts to improve various diagnosis values.

PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향 (The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media)

  • 안샤론;박훈희;박민수;오신현;이승재;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.77-81
    • /
    • 2009
  • PET/CT (Positron Emission Tomography/ Computed Tomography)의 PET은 생체의 생리, 화학적인 정보를 정량적으로 영상화할 수 있지만 해부학적인 구조를 명확히 나타내는 데에는 한계를 가지고 있어 PET에 CT를 접목시켜 해상력을 높임은 물론, CT 데이터를 감쇠보정에 이용하여 촬영시간도 단축시키고 잡음제거 측면에서도 우수함을 나타내고 있다. 또한 CT 검사 시 조영제를 사용함으로써 병변의 정확한 범위를 확인하고 정상 구조물을 구별하는데 용이하여 조영제의 사용이 증가하고 있는 추세이다. 하지만 조영제를 사용한 경우 CT 영상의 보정에 따라 PET/CT 영상에서 표준화섭취계수(Standardized Uptake Value: SUV)에 영향을 미치기 때문에 본 연구에서는 조영제 보정에 따라 표준화섭취계수(SUV)에 미치는 정도를 평가하였다. 2008년 4월에서 7월 사이에 본원에서 PET/CT검사를 시행한 환자 중 요오드 조영제에 대한 부작용이 없고 당뇨병이 없는 환자 30명을 대상으로 (남: 20, 여: 10, 연령범위: 연령범위 27세~72세, 평균나이 49.6세) 후향적 조사를 하였다. 장비는 DSTe (General Electric Healthcare, Milwaukee, MI, USA)를 사용하였다. 검사자에게 $^{18}F$-FDG 370~555 MBq를 몸무게에 따라 주사하였으며, 1시간 정도의 안정된 자세를 취한 후 검사를 시행하였다. CT촬영은 140 kV, 210 mA로 설정하였으며 CT 검사에 사용되는 조영제의 양은 환자 몸무게 1 kg당 2 cc를 주입하였다. 검사 후 최초 획득 데이터(raw data)를 이용하여 조영제 영향을 보정한 CT데이터와 보정을 하지 않은 CT데이터로 감쇠보정을 하여 영상을 얻었으며 각 영상의 간, 심장, 폐에 관심영역(Region of Interest: ROI)를 그려 SUV를 측정하여 비교하였다. SUV를 측정한 결과 조영제 보정을 한 영상의 표준화섭취계수(SUV)가 줄어듦을 알 수 있었다. 조영제에 대한 영향이 거의 없는 폐에서는 수치적인 변화가 거의 나타나지 않았으며 통계적으로도 유의하지 않았다. 비교적 혈류가 풍부한 간과 심장에서 조영제 보정으로 인한 표준화 섭취계수(SUV) 값이 수치적인 차이를 보였으나 간에서만 통계적으로 유의했다. PET/CT 검사에서 조영제의 사용으로 인하여 검사하고자 하는 부위의 대조도를 증강시켜 진단의 효율성을 높이고 있지만 이로 인하여 표준화섭취계수(SUV)의 증가가 일어난다. 따라서 조영제를 사용한 CT로 감쇠보정을 할 경우에 조영제의 영향에 대한 보정을 해주어 고해상력의 해부학적 영상뿐만 아니라 신뢰를 할 수 있는 반정량적 방법으로 진단적 가치를 더욱 높일 수 있을 것이며 다른 장기에 대해서도 추가적인 연구가 필요하다고 생각된다.

  • PDF

CT검사에서 조영제의 혈관외유출에 의한 목 및 흉부 손상의 3차원 재구성 영상 (Extravasation Injury of Contrast Media in the Neck and Thorax During MDCT Scanning with 3D Image Reformation Findings)

  • 권대철;장근조;유병규;이종석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권3호
    • /
    • pp.281-287
    • /
    • 2007
  • 전산화단층촬영에서 조영제를 자동주입기로 주입하는 과정에서 발생하는 혈관외유출은 조직의 괴사 및 손상의 원인이 되고 있다. 대량의 혈관외유출은 구획증후군으로 발전하여 근막절개술을 시행하는 경우가 발생한다. 혈관외유출이 발생한 환자를 대상으로 혈관외유출 범위 및 부위 정도를 평가하기 위해 CT 검사에서 경정맥에 조영제을 주입하는 과정에서 혈관외유출이 발생한 환자를 대상으로 하였다. 조영제에 의한 혈관외유출 범위 및 손상을 확인하기 조영제 주입부위의 목 및 가슴의 부위를 MDCT를 이용하여 스캔하였다. 경정맥 주사부위의 혈관외유출부위를 MPR, MIP와 볼륨 렌더링의 3차원영상을 3D 프로그램을 이용하여 묘출하였다. 3차원 재구성 영상은 높은 해상력과 정확도를 제공하여 혈관외유출 범위 및 부위를 확인 하여, 환자의 예방의 필요성 및 사후 조치 및 적절한 치료와 수술 계획에 유용하게 이용될 것으로 기대된다.

  • PDF

Oral contrast media for computed tomography of canine pancreas

  • Choi, Jihye;Chang, Jinhwa;Oh, Sunkyoung;Yoon, Junghee
    • 대한수의학회지
    • /
    • 제51권2호
    • /
    • pp.165-169
    • /
    • 2011
  • Barium suspension, oral iodine contrast medium and water were applied in eight dogs to evaluate (1) distension of gastrointestinal tract, (2) the effect of the oral contrast media on the identification of the pancreas from surrounding organs, and (3) image quality and the presence of artifacts in canine pancreas computed tomography (CT) images. Oral iodine contrast medium, gastrografin, produced significant artifacts that deteriorated the CT images of the pancreas. The use of water did not provide the fullness of the gastrointestinal lumens. Barium suspension was effective for the identification of the pancreas from the surrounding gastrointestinal tract, without significantly increasing image noise. Barium suspension can be used as an optimal contrast medium that will not cause an adverse effect on the pancreatic density and image quality.

F-18 FDG PET/CT 전신 영상에서 SUVs 측정에 기반한 조기/정밀 진단 연구 (Enhancement of the Early/Precise Diagnosis Based on the Measurement of SUVs in F-18 FDG PET/CT Whole-body Image)

  • 박정규;김성규;조인호;공은정;박명환;조복연
    • 한국의학물리학회지:의학물리
    • /
    • 제24권3호
    • /
    • pp.176-182
    • /
    • 2013
  • 본 연구의 목적은 건강한 검진자들을 대상으로 F-18 FDG PET/CT 전신 영상에서 진단 수준을 향상하고자 관심부피를 이용하여 정상부위의 SUVs, 즉 SUVLBM, SUVBW, SUVBSA의 데이터를 마련하였다. 각각의 최대치(maximum), 평균치(mean), 표준편차(standard deviation), 역치(threshold)를 제시 하고자 한다. 2012년 7월부터 8월까지 전신 F-18 FDG PET/CT 검사를 시행한 총 31명을 대상으로 SUVs를 측정 하였다. 측정의 정확도를 높이고자 핵의학 전문의의 소견으로 이중에서 26명의 건강한 수검자를 대상으로 하였다. 조영제 사용유무와 관계없이 PET/CT의 SUVs 측정에서 SUVBW의 측정치가 가장 높았으며, SUVLBM, SUVBSA 순으로 나타났다. SUVLBM-최대치를 이용하여 조영제를 사용하지 않은 군과 사용한 군을 비교했을 경우, 조영제를 사용했을 경우 측정치가 증가하는 경향을 보였으며, 8부위 중 간, 대동맥, 요추-5, 소뇌는 매우 유의하게 차이가 있는 것으로 나타났다(p<0.05). PET/CT의 모든 영상의 판독에서 본 SUVs 데이터가 조기정밀/진단 수준을 향상 하는데 기초 자료가 될 것이라고 판단되며, VOI를 이용한 연구가 활발히 이루어지길 기대한다.