• Title/Summary/Keyword: CT channel

Search Result 71, Processing Time 0.029 seconds

Effect of Interference in CSMA/CA Based MAC Protocol for Underwater Network (CSMA/CA 기반 수중 통신망에서 간섭의 영향 연구)

  • Song, Min-je;Cho, Ho-shin;Jang, Youn-seon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.8
    • /
    • pp.1631-1636
    • /
    • 2015
  • With the advance of wireless communication technology in terrestrial area, underwater communication is also evolving very fast from a simple point-to-point transmission to an elaborate networked communications. Underwater acoustic channel has quite different features comparing with the terrestrial radio channel in terms of propagation delay, Doppler shift, multipath, and path loss. Thus, existing technologies developed for terrestrial communication might not work properly in underwater channel. Especially medium access control (MAC) protocols which highly depend on propagation phenomenon should be newly designed for underwater network. CSMA/CA has drawn lots of attention as a candidate of underwater MAC protocol, since it is able to resolve a packet collision and the hidden node problem. However, a received signal could be degraded by the interferences from the nodes locating outside the receiver's propagation radius. In this paper, we study the effects of interference on the CSMA/CA based underwater network. We derived the SNR with the interference using the sonar equation and analyzed the degradation of the RTS/CTS effects. These results are compared with the terrestrial results to understand the differences. Finally we summarized the design considerations in CSMA/CA based underwater network.

Remote field Eddy Current Technique Development for Gap Measurement of Neighboring Tubes of Nuclear Fuel Channel in Pressurized Heavy Water Reactor (중수로 핵연료채널과 인접관의 간격측정을 위한 원거리장 와전류검사 기술개발)

  • Jung, H.K.;Lee, D.H.;Lee, Y.S.;Huh, H;Cheong, Y.M.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.164-170
    • /
    • 2004
  • Liquid Injection Nozzle(LIN) tube and Calandria tube(CT) in pressurized Heavy Water Reactor (PHWR) are .ross-aligned horizontally. These neighboring tubes can contact each other due to the sag of the calandria tube resulting from the irradiation creep and thermal creep, and fuel load, etc. In order to judge the contact which might be the safety concern, the remote field eddy current (RFEC) technology is applied for the gap measurement in this paper. LIN can be detected by inserting the RFEC probe into pressure tube (PT) at the crossing point directly. To obtain the optimal conditions of the RFEC inspection, the sensitivity, penetration and noise signals are considered simultaneously. The optimal frequency and coil spacing are 1kHz and 200mm respectively. Possible noises during LIN signal acquisition are caused by lift-off, PT thickness variation, and gap variation between PT and CT. The simulated noise signals were investigated by the Volume Integral Method(VIM). Signal analysis on the voltage plane describes the amplitude and shape of LIN and possible defects at several frequencies. All the RFEC measurements in the laboratory were done in variance with the CT/LIN gap and showed the relationship between the LIN gap and the signal parameters by analyzing the voltage plane signals.

Control Frame Design for Improvement Transmit Efficiency in the Wireless Networks (무선 네트워크에서 전송효율증대를 위한 제어프레임 설계)

  • Han, Jae-Kyun;Pyeon, Seok-Beom
    • 전자공학회논문지 IE
    • /
    • v.48 no.2
    • /
    • pp.61-70
    • /
    • 2011
  • IEEE 802.11 wireless network supports control frames like RTS/CTS(Request To Send / Clear To Send). Because they is defend to frame collection problems. It helps to solve the frame collection problem but decreases the throughput rate. Also, control frame makes False Node Problem. This problem is makes to other wireless nodes don't work and don't find channels in the same cell and near cells. We proposed a reformed new control frame for efficiency throughput rate and solution of False Node Problem. New control frame is to have added to 4 bytes of channel detection ability at the RTS frames. Channel detection ability supported to check channel at the wireless node start to transmit data frame, We expect that channel detection ability make prevent False Node Problem for increase to access number to channel. We perform comparative analysis in terms of delay(sec) and load(bits/sec) with reform RTS/CTS method which proves the efficiency of the proposed method.

Uumanned Automatic System for Function Test of Analog Subscriber Line Card (아날로그 가입자 정합 회로 기능시험을 위한 무인 자동화 시스템)

  • 이성원;김영범
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.432-437
    • /
    • 2002
  • DSPA311(Analog Subscriber Line Board Assembly) is offer the interface of between analog subscriber and TDX-100 exchange system. DSPA311 is belong ASI block, accommodate dial and MFC telephone subscriber of 32 channel, and voice signal designed for interface with TSW, and 2 and 4 wire loop impedance is 600 (ohm). DSPA311 is consist 4 channel daughter beard QSLM-10(Quad Subscriber Line Module-10) and perform BORSCHT and be possible A/U-law select and GAIN value control by data control of DSPA171(Device controller I). In this Paper, We described the function test program for the DSPA311 Board by using the HP3070CT combinational test system, and an unmanned automatic test system.

  • PDF

A Design of Multi-Channel Biotelemetry for ECG Encoding and Transmission Over the Public Telephone Line (공중 전화회선용 다중 채널 ECG데이터 원격 측정시스템 설계)

  • Gye, Sin-Ung;Jang, Won-Seok;Hong, Seung-Hong
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.21-34
    • /
    • 1986
  • In this paper, we described the ECG telemetry system via the Public Telephone Line. The system consist of a signal acquisition and measurement section, a signal processing section, and a signal transmission section. It used 8 bits microprocessor. The transmission section is composed of 3 ch. analog modulators and 1 ct. digital modem. Especially, using the digital modem, signal is transmitted with about 50n data reduction ratio by the TP (Turning Point) algorithm. The acoustic coupler or inductive coil for linking the public telephone line are used. The speed of the digital modem is 300 baud rate. The MCBS (Multi Channel Biotelemetry System) is tested and evaluated through the experiment.

  • PDF

Radius Intermedius Stenosis Induced Myocardial Perfusion Defect: Provened by the Fusion Images of Myocardial Perfusion SPECT and 64 Channel CTA (심근관류 SPECT와 64채널 전산화 단층혈관 촬영 사진 융합으로 증명된 radius intermedius 협착에 의한 심근관류 저하)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jong-Seon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.77-78
    • /
    • 2008
  • A 71-year-old woman was assigned to our department for Tc-99m myocardial perfusion SPECT(MPS) and coronary CT angiography. She admitted for substernal pain, via the ER, 2 days ago. The heart was scanned after intravenous injection of 925 MBq of $^{99m}Tc$-sestamibi adenosine-induced stress SPECT using dual head gamma camera (Hawkeye, GE healthcare. USA). The MPS shows decreased tracer uptake in the apical & mid area of anterior & lateral wall and mid & basal inferior wall. Coronary CT angiograph was obtained using Discovery VCT (GE healthcare). 3D angiography portrayed significant stenosis of ramus intermedius(RI) and posterolateral branch of right coronary artery(PLB) with fibrocalcified plaque. Two images were fused using Cardiac IQ fusion softwear package (Advantage workstation 4.4, GE healthcare) The fusion images explain the perfusion defect of anterior, lateral and inferior wall is due to stenosis of the RI and PLB. And 3 days later, coronary angiography was done and revealed the marked stenosis of RI and PLB. Then balloon angioplasty and stent was instituted in RI. Cardiac SPECT/CT fusion imaging provides additional information about hemodynamic relevance and facilitates lesion interpretation by allowing exact allocation of perfusion defects to its subtending coronary artery.

Proteomic Analysis of a Rat Cerebral Ischemic Injury Model after Human Cerebral Endothelial Cell Transplantation

  • Choi, Tae-Min;Yun, Misun;Lee, Jung-Kil;Park, Jong-Tae;Park, Man-Seok;Kim, Hyung-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.6
    • /
    • pp.544-550
    • /
    • 2016
  • Objective : Cerebral endothelial cells have unique biological features and are fascinating candidate cells for stroke therapy. Methods : In order to understand the molecular mechanisms of human cerebral endothelial cell (hCMEC/D3) transplantation in a rat stroke model, we performed proteomic analysis using 2-dimensional electrophoresis and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Protein expression was confirmed by quantitative real-time PCR and Western blot. Results : Several protein spots were identified by gel electrophoresis in the sham, cerebral ischemia (CI), and CI with hCMEC/D3 treatment cerebral ischemia with cell transplantation (CT) groups, and we identified 14 differentially expressed proteins in the CT group. Proteins involved in mitochondrial dysfunction (paraplegin matrix AAA peptidase subunit, SPG7), neuroinflammation (peroxiredoxin 6, PRDX6), and neuronal death (zinc finger protein 90, ZFP90) were markedly reduced in the CT group compared with the CI group. The expression of chloride intracellular channel 4 proteins involved in post-ischemic vasculogenesis was significantly decreased in the CI group but comparable to sham in the CT group. Conclusion : These results contribute to our understanding of the early phase processes that follow cerebral endothelial cell treatment in CI. Moreover, some of the identified proteins may present promising new targets for stroke therapy.

Simulation Analysis of RICH-DP for Real-time Service in Multi-Channel Networks (다중채널 무선망에서 실시간 서비스를 제공하기 위한 RICH-DP 시뮬레이션 분석)

  • 김철규;최덕규
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.05a
    • /
    • pp.133-133
    • /
    • 2001
  • 무선 근거리 지역망(Wireless LAN;WLAN) 환경에서 다중 채널을 이용하여 실시간 서비스를 제공하기 위한 매체 접근제어 계층에서의 채널의 사용 구간 할당 방법을 제안하고, 컴퓨터 모의 실험을 통하여 제한된 방식의 실시간 서비스 지원 성능과 채널의 사용 효율을 분석한다. 제안한 채널 사용 구간 할당 방안은 개선된 매체 접근 제어 프로토콜 RICH-DP (Receiver-Initiated Channel-Hopping with Dual Polling)를 바탕으로 한다. 무선 환경에서 RTS-CTS를 사용하는 프로토콜은 SRMA, MACA, MACAW, IEEE 802.11, FAMA 등이 있다. 최근에 단일 채널을 환경에서 RICH(Receiver Initiated Channel-Mopping) 프로토콜이 제안되었다. RICH는 충돌 회피를 위해서 경쟁 구간에서 충돌 감지(carrier sensing)을 사용한다. RICH는 제한된 어플케이션에 국한되는 단절이 있다. 반면에 RICH-DP는 다중 채널 환경에서 충돌 감지와 특별한 코드(spreading code) 할당 없이 일반화된 충돌 회피를 제공한다. 실시간 서비스를 이용하자 차는 단말들로 하여금 RICH-DP를 사용하여 서비스를 제공할 때, 대역폭에 대한 정보를 AP(Access Point)로 전송토록 함으로써 비경쟁 구간에서 뿐 아니라, 경쟁구간에서도 높은 채널 효율이 얻어질 수 있도록 하고 있다. 제한된 방안의 성능 평가를 위한 모의 실험은 OPNET를 이용하여 실시간 서비스 데이터를 7개의 상태 천이를 갖는 VBR 소스로 모델링하고 비동기 트래픽들은 Poisson 소스로 모델링하여 실시간 서비스 단발들의 이용 대역폭과 채널 처리율과 시스템 지연시간을 성능 평가 인자로 하여 수행하였다. 논문에서 제한된 방법을 적용한 개선된 RICH-DP을 모의 실험을 통하여 분석한 결과 기존의 제한된 RICH-DP는 실시간 서비스에 대한 처리율이 낮아지며 서비스 시간이 보장되지 못했다. 따라서 실시간 서비스에 대한 새로운 제안된 기법을 제안하고 성능 평가한 결과 기존의 RICH-DP보다 성능이 향상됨을 확인 할 수 있었다.

  • PDF

Accuracy Analysis of Magnetic Resonance Angiography and Computed Tomography Angiography Using a Flow Experimental Model

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Park, Cheol-Soo;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.40-46
    • /
    • 2015
  • This study investigated the accuracy of magnetic resonance angiography (MRA) and computed tomography angiography (CTA) in terms of reflecting the actual vascular length. Three-dimensional time of flight (3D TOF) MRA, 3D contrast-enhanced (CE) MRA, volume-rendering after CTA and maximum intensity projection were investigated using a flow model phantom with a diameter of 2.11 mm and area of $0.26cm^2$. 1.5 and 3.0 Tesla devices were used for 3D TOF MRA and 3D CE MRA. CTA was investigated using 16 and 64 channel CT scanners, and the images were transmitted and reconstructed by volume-rendering and maximum intensity projection, followed by conduit length measurement as described above. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s using the 3.0 Tesla apparatus, and $2.57{\pm}0.07mm$ with a velocity of 71.5 cm/s using the 1.5 Tesla apparatus; both images were magnified from the actual measurement of 2.11 mm. The measurement with the 16 channel CT scanner was smaller ($3.83{\pm}0.37mm$) than the reconstructed image on maximum intensity projection. The images from CTA from examination apparatus and reconstruction technique were all larger than the actual measurement.