• 제목/요약/키워드: CT R&D

검색결과 165건 처리시간 0.03초

요추에 있어서 파라미터 기법과 단면CT영상을 이용한 3차원 형상 모델링의 비교 (Comparision of 3-D Geometrical Modelling of the Lumbar Spine Using Parameterized and Cross-sectional CT Image Reconstruction Method)

  • 김성민;김성재;탁계래;김남현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.159-160
    • /
    • 1998
  • In this study, a three-dimensional geometrical parameterized finite element modeling of the lumbar spine is compared with the 3-D reconstruction model from 2-D CT image. feasibility and accuracy of the parameterized modeling method is evaluated compared with conventional 3-D reconstruction method from 2-D CT image.

  • PDF

PET 검사 시 Reconstructed data와 Re-sliced data의 표준섭취계수와 Metabolic Tumor Volume의 비교 평가 (Evaluation of Standardized Uptake Value and Metabolic Tumor Volume between Reconstructed data and Re-sliced data in PET Study)

  • 도용호;이홍재;김진의
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.3-8
    • /
    • 2016
  • PET 검사에서 SUV는 암의 원발 부위, 전이여부 파악 및 병기결정, 재발여부 판단에 도움을 주는 지표이다. 특히 항암, 방사선치료 후 효과 판정을 위한 검사 시 이전 검사와의 SUV 비교 평가가 중요시 된다. 그러나 핵의학과 에서 자체적으로 데이터를 저장하는 외장하드, mini PACS 등의 저장 장치는 데이터 손실의 가능성을 가지고 있다. 이에 본 연구에서는 workstation의 reconstructed data (R-D)와 병원 PACS로 전송한 R-D, re-sliced data (S-D) 사이의 SUV를 비교 평가하여 자체 저장장치의 데이터 손실 시 PACS로 전송한 데이터의 사용가능 여부를 확인 하고자 한다. Biograph Truepoint 40, mCT 40, mCT 64, mMR (Siemens, Germany)장비에서 2015년 1월부터 2월까지 $^{18}F-FDG$ PET 검사를 시행한 20명($60.5{\pm}8.3$세)의 데이터를 분석하였다. Workstation의 R-D와 PACS의 R-D, S-D 데이터를 Syngo.via 프로그램으로 전송하여 liver, aorta, tumor 부위의 max SUV($SUV_{max}$), peak SUV ($SUV_{peak}$)와 tumor의 metabolic tumor volume (MTV)를 측정하였다. Workstation과 PACS의 R-D에서 liver, aorta, tumor의 평균 $SUV_{max}$$2.95{\pm}0.59$, $2.35{\pm}0.61$, $10.36{\pm}6.15$ 이었고 $SUV_{peak}$$2.70{\pm}0.51$, $2.07{\pm}0.43$, $7.67{\pm}3.73$으로 동일하였으며 통계적으로 유의한 차이가 없었다(p>0.05). PACS의 S-D는 R-D대비 평균 $SUV_{max}$는 5.18%, 7.22%, 12.11%, $SUV_{peak}$는 2.61%, 3.63%, 10.07% 감소하였으며 통계적으로 유의한 차이가 있었다(p<0.05). R-D와 S-D에서 결과 값의 상관계수는 $SUV_{max}$에서 0.99, 0.96, 0.99이었고 $SUV_{peak}$에서 0.99, 0.99, 0.99로 모두 양의 상관관계가 있었다. Bland-Altman 분석에서 2표준편차는 $SUV_{max}$에서 0.125, 0.290, 1.864이었고 $SUV_{peak}$에서 0.053, 0.103, 0.826이었다. Tumor의 MTV는 workstation과 PACS의 R-D에서 모두 $14.21{\pm}12.72cm^3$로 동일하였다(p>0.05). PACS의 S-D에서는 R-D 대비 0.12% 감소하였으며 통계적으로 유의한 차이가 없었다(p>0.05). R-D와 S-D에서 상관계수는 0.99이었고 Bland-Altman 분석에서 2표준편차는 2.243이였다. 본 논문에서 PACS에 저장된 R-D의 경우 workstation의 R-D와 비교하여 $SUV_{max}$, $SUV_{peak}$, MTV 모두에서 동일한 값을 보였으나 S-D의 경우 상관관계는 높지만 MTV를 제외한 $SUV_{max}$, $SUV_{peak}$는 통계적으로 유의한 차이가 있었다. R-D를 안정성 있는 병원 PACS에 저장한다면 자체 저장장치의 데이터 손실 시 이전 PET 데이터와의 비교에서 신뢰성 있는 SUV 분석이 가능할 것이라 생각된다.

  • PDF

폐암의 조직학적 분류에 따른 종양의 FDG 섭취와 CT 조영증강정도에 관한 연구 (FDG Uptake and a Contrast Enhancement According to Histopathologic Types in Lung Cancers)

  • 한유미;최재걸;김영철;박은경
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권1호
    • /
    • pp.19-25
    • /
    • 2009
  • 목적: 폐암에서 양전자단층촬영(PET-CT)에서의 2[F-18]-fluoro-2-deoxy-d-glucose (FDG)의 최대 표준화섭취(SUVmax)와 전산화단층찰영(CT)에서의 조영증장정도에 서로 연관성이 있는지를 알아보고 SUVmax와 조영증강 정도에 있어 폐암의 조직학적 유형간에 유의한 차이가 있는지를 평가 하고자 하였다. 대상 및 방법: PET-CT와 조영증강 흥부 CT를 시행하고 조직학적으로 원발성 폐암으로 확진된 환자 53명을 대상으로 하였다. 초기 및 지연 PET-CT영상에서의 종양의 SUVmax (SUV1, SUV2), 지연영상에서의 SUVmax의 증가정도(SUVd), 잔류지수(RI) 및 종양의 CT 조영증강정도를 측정하고 상관관계를 알아보았으며, 이 변수들의 폐암의 조직학적 유형에 따른 차이와 종양내부에서 차이를 평가하였다. 결과: 평균값과 표준 편차는 SUV1이 $8.3{\pm}4.4$, SUV2가 $10.7{\pm}5.7$, SUVd가 $2.4{\pm}1.6$, RI가 $30{\pm}14$, 조영증강정도가 $47.1{\pm}14.8$ HU (Hounsfield Unit)이었다. 조직학적 유형 간 SUV1과 조영증강정도에는 차이가 없었다. SUV1과 SUVd 사이에는 r=0.74(p<0.01), SUV1과 종양의 크기 사이에는 r=0.58 (p<0.01)로 유의한 상관관계가 있었고 SUV1과 조영증강정도 사이에는 상관관계가 없었다(r=0.06, p=0.69). 같은 종양 내부에서 최대 FDG 섭취부위와 최대 조영증강부위가 일치하지 않는 경우가 10예 있었다. 결론: 폐암에서의 FDG 섭취정도와 CT 조영증강정도는 서로 유의한 양적인 선형 상관관계를 보이지 않았으며 조직학적 분류에 따른 FDG 섭취나 조영증강정도의 차이도 없었다.

Frankfort horizontal plane is an appropriate three-dimensinal reference in the evaluation of clinical and skeletal cant

  • Oh, Suseok;Ahn, Jaemyung;Nam, Ki-Uk;Paeng, Jun-Young;Hong, Jongrak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권2호
    • /
    • pp.71-76
    • /
    • 2013
  • Objectives: In three-dimensional computed tomography (3D-CT), the cant is evaluated by measuring the distance between the reference plane (or line) and the tooth. The purpose of this study was to determine the horizontal skeletal reference plane that showed the greatest correlation with clinical evaluation. Materials and Methods: The subjects were 15 patients who closed their eyes during the CT image taking process. The menton points of all patients deviated by more than 3 mm. In the first evaluation, clinical cant was measured. The distance from the inner canthus to the ipsilateral canine tip and the distance from the eyelid to the ipsilateral first molar were obtained. The distance between the left and right sides was also measured. In the second evaluation, skeletal cant was measured. Six reference planes and one line were used for the evaluation of occlusal cant: 1) FH plane R: Or.R - Or.L - Po.R; 2) FH plane L: Or.R - Or.L - Po.L; 3) F. Ovale plane R: Rt.F.Ovale - Lt.F.Ovale - Or.R; 4) F. Ovale plane L: Rt.F.Ovale - Lt.F.Ovale - Or.L; 5) FZS plane R: Rt.FZS - Lt.FZS - Po.R; 6) FZS plane R: Rt.FZS - Lt.FZS - Po.L, and; 7) FZS line: Rt.FZS - Lt.FZS. Results: The clinical and skeletal cants were compared using linear regression analysis. The FH plane R, FH plane L, and FZS line showed the highest correlation (P<0.05). Conclusion: The FH plane R and FH plane L are the most appropriate horizontal reference plane in evaluation of occlusal cant on 3D-CT.

Potential Utility of FDG PET-CT as a Non-invasive Tool for Monitoring Local Immune Responses

  • Lee, Seungho;Choi, Seohee;Kim, Sang Yong;Yun, Mi Jin;Kim, Hyoung-Il
    • Journal of Gastric Cancer
    • /
    • 제17권4호
    • /
    • pp.384-393
    • /
    • 2017
  • Purpose: The tumor microenvironment is known to be associated with the metabolic activity of cancer cells and local immune reactions. We hypothesized that glucose metabolism measured by 2-deoxy-2-($^{18}F$)fluoro-D-glucose ($^{18}F-FDG$) positron emission tomography (PET)-computed tomography (CT) ($^{18}F-FDG$ PET-CT) would be associated with local immune responses evaluated according to the presence of tumor infiltrating lymphocytes (TILs). Materials and Methods: We retrospectively reviewed 56 patients who underwent $^{18}F-FDG$ PET-CT prior to gastrectomy. In resected tumor specimens, TIL subsets, including cluster of differentiation (CD) 3, CD4, CD8, Forkhead box P3 (Foxp3), and granzyme B, were subjected to immunohistochemical analysis. The prognostic nutritional index (PNI) was calculated as: ($10{\times}serum$ albumin value)+($0.005{\times}peripheral$ lymphocyte counts). Additionally, the maximum standard uptake value ($SUV_{max}$) was calculated to evaluate the metabolic activity of cancer cells. Results: The $SUV_{max}$ was positively correlated with larger tumor size (R=0.293; P=0.029) and negatively correlated with PNI (R=-0.407; P=0.002). A higher $SUV_{max}$ showed a marginal association with higher CD3 (+) T lymphocyte counts (R=0.227; P=0.092) and a significant association with higher Foxp3 (+) T lymphocyte counts (R=0.431; P=0.009). No other clinicopathological characteristics were associated with $SUV_{max}$ or TILs. Survival analysis, however, indicated that neither $SUV_{max}$ nor Foxp3 held prognostic significance. Conclusions: FDG uptake on PET-CT could be associated with TILs, especially regulatory T cells, in gastric cancer. This finding may suggest that PET-CT could be of use as a non-invasive tool for monitoring the tumor microenvironment in patients with gastric cancer.

개인용 컴퓨터에서 재구성한 3차원 전산화단층영상의 두부계측 재현성 (Reproducibilities of cephalometric measurements of three-dimensional CT images reconstructed in the personal computer)

  • 전국진;박혁;이희철;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제33권3호
    • /
    • pp.171-178
    • /
    • 2003
  • Purpose: The purpose of this study was to report the reproducibility of intra-observer and inter-observer consistency of cephalometric measurements using three-dimensional (3D) computed tomography (CT), and the degree of difference of the cephalometric measurements. Materials and Methods: CT images of 16 adult patients with normal class I occlusion were sent to personal computer and reconstructed into 3D images using V-Works 3.5/sup TM/(Cybermed Inc., Seoul, Korea). With the internal program of V-Works 3.5/sup TM/, 12 landmarks on regular cephalograms were transformed into 21 analytic categories and measured by 2 observers and in addition, one of the observers repeated their measurements. Intra-observer difference was calculated using paired t-test, and inter-observer by two sample test. Results: There were significant differences in the intra-observer measurements (p < 0.05) in four of the categories which included ANS-Me, ANS-PNS, Cdl-Go (Lt), GoL-GoR, but with the exception of Cdl-Go (Lt), ZmL-ZmR, Zyo-Zyo, the average differences were within 2 mm of each other. The inter-observer observations also showed significant differences in the measurements of the ZmL-ZmR and Zyo-Zyo categories (p < 0.05). With the exception of the Cdl-Me (Rt), ZmL-ZmR, Zyo-Zyo categories, the average differences between the two observers were within 2 mm, but the ZmL-ZmR and Zyo-Zyo values differed greatly with values of 8.10 and 19.8 mm respectively. Conclusion: In general, 3D CT images showed greater accuracy and reproducibility, with the exception of suture areas such as Zm and Zyo, than regular cephalograms in orthodontic measurements, showing differences of less than 2 mm, therefore 3D CT images can be useful in cephalometric measurements and treatment planning.

  • PDF

딥러닝을 이용한 CT 영상에서 생체 공여자의 간 절제율 및 재생률 측정 (Measurements of the Hepatectomy Rate and Regeneration Rate Using Deep Learning in CT Scan of Living Donors)

  • 문새별;김영재;이원석;김광기
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권6호
    • /
    • pp.434-440
    • /
    • 2022
  • Liver transplantation is a critical used treatment method for patients with end-stage liver disease. The number of cases of living donor liver transplantation is increasing due to the imbalance in needs and supplies for brain-dead organ donation. As a result, the importance of the accuracy of the donor's suitability evaluation is also increasing rapidly. To measure the donor's liver volume accurately is the most important, that is absolutely necessary for the recipient's postoperative progress and the donor's safety. Therefore, we propose liver segmentation in abdominal CT images from pre-operation, POD 7, and POD 63 with a two-dimensional U-Net. In addition, we introduce an algorithm to measure the volume of the segmented liver and measure the hepatectomy rate and regeneration rate of pre-operation, POD 7, and POD 63. The performance for the learning model shows the best results in the images from pre-operation. Each dataset from pre-operation, POD 7, and POD 63 has the DSC of 94.55 ± 9.24%, 88.40 ± 18.01%, and 90.64 ± 14.35%. The mean of the measured liver volumes by trained model are 1423.44 ± 270.17 ml in pre-operation, 842.99 ± 190.95 ml in POD 7, and 1048.32 ± 201.02 ml in POD 63. The donor's hepatectomy rate is an average of 39.68 ± 13.06%, and the regeneration rate in POD 63 is an average of 14.78 ± 14.07%.

폐기종환자에서 고해상도 CT와 폐기능검사와의 상관관계 (Correlation between High-Resolution CT and Pulmonary Function Tests in Patients with Emphysema)

  • 안중현;박정미;고승현;윤종구;권순석;김영균;김관형;문화식;박성학;송정섭
    • Tuberculosis and Respiratory Diseases
    • /
    • 제43권3호
    • /
    • pp.367-376
    • /
    • 1996
  • 연구배경 : 폐기종의 실제적 진단은 환자들의 임상적 소견과 함께 주로 폐기능검사와 방사선학적검사등으로 이루어지며, 최근에는 고해상도 CT가 널려 이용되는 추세이다. 따라서 폐기종환자들의 고해상도 CT상 나타나는 질환의 심한 정도가 환자의 폐기능검사나 동맥혈가스검사 및 그외의 환자의 임상적 특성들과 어느 정도나 서로 상관관계를 갖는지 CT의 진단적 가치를 알아보고자 하였다. 방법 : 1994년 10월부터 1995년 10월까지 가톨릭의대부속 성모병원에서 폐기종의 임상적 증상과 증후를 보인 환자들중에 폐기능검사와 고해상도 CT등을 이용하여 폐기종으로 진단한 20예(남자 16명, 여자4명, 평균연령 62.5세)를 대상으로 하였다. 고해상도 CT(Siemens Somatom plus Vd-30)상 폐기종의 심한정도는 본 대학 방사선과 전문의에 의해 Sakai방법으로 점수를 판정하였고, 폐기능검사(Medical Graphics Cooperation 1082 Series Plethysmography)상의 여러 지표들과 환자의 연령, 성별, 선정, 체중, 흡연력, 동맥혈가스분석결과 및 CBC상 지표등과 고해상도 CT상 폐기종점수와의 유의한 상관관계를 측정하였다. 결과 : 1) 고해상도 CT상 폐기종점수는 폐기능검사상의 지표인 1초간 노력성 호기량(FEV1), 노력성 폐활량(FVC), 폐확산능(DLco), 폐포량에 대한 폐확산능(DLco/VA)등과 각각 의미있는 역상관관계(inverse correlation)를 보였다(각각의 상관계수 r=-0.53 p<0.05, r=-0.47 p<0.05, r=-0.68 p<0.05, r=-0.49 p<0.05). 2) 고해상도 CT상 폐기종점수는 총폐활량(TLC) 및 잔기량(RV)등과도 의미있는 상관관계가 있었다(각각의 상관계수 r=0.50 p<0.05, r=0.64 p<0.05). 3) 고해상도 CT상 폐기종점수는 동맥혈가스분석검사상 동맥혈산소분압(PaO2)과 의미있는 역상관관계 (r=-0.48 p<0.05)를 보였고 폐포-동맥간 산소분압차{D(A-a)O2}와 의미있는 상관관계(r=0.48 p<0.05)를 보였으나, 동맥혈 이산화탄소분압(PaCO2)과는 서로 상관관계가 없었다(r=-0.32 p>0.05). 4) 고해상도 CT상 폐기종점수는 환자의 연령, 성별, 신장, 체중, 흡연량 및 CBC상 헤모글로빈, 헤마토크리트, 백혈구수등과는 의미있는 상관관계가 없었다. 결론 : 이상의 결과로 폐기종환자에서 고해상도 CT상 폐기종점수는 폐기능검사상의 폐기능장애정도 및 동맥혈가스분석결과와 유의한 상관관계가 있었다.

  • PDF

3차원 컴퓨터단층촬영 영상을 이용한 전두동 발달의 연구 (Developmental Study of Korean Frontal Sinus by using 3D CT Scan)

  • 윤인식;나동균
    • 대한두개안면성형외과학회지
    • /
    • 제10권2호
    • /
    • pp.103-108
    • /
    • 2009
  • Purpose: Although there are many reports on the development of paranasal sinuses, few studies were performed with respect to the frontal sinus with 3D CT, especially in Korean children. In this study, we evaluated the normal development of frontal sinus in Korean children with 3D CT imaging. Methods: A total of 301 patients under the age of 20 were reviewed retrospectively. Maximal AP (anteroposterior) length, height and width were measured with the aid of computer device. The volume of frontal sinus was also evaluated. Results: At the age of more than 4, the pneumatization of frontal sinus was detected. Frontal sinus developed continuously and was observed in almost every children at the age of more than 17. The AP length, height, width and volume of frontal sinus were enlarged continuously until the age of 20. And the maximal growth of frontal sinus was observed at puberty. The width and volume of frontal sinus showed high correlation coefficient (r=0.8) relative to height or AP distance. Conclusion: The results of this study may be helpful in the comprehension of normal development of frontal sinus in Korean children.