• Title/Summary/Keyword: CT Examination Time

Search Result 135, Processing Time 0.029 seconds

The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT (소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가)

  • Kim, Gu;Kim, Gyeong-Rip;Lee, Eun-Sook;Cho, Hee-Jung;Sung, Soon-Ki;Moon, Seul-ji-a;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.284-292
    • /
    • 2019
  • To evaluate the usefulness of pediatric chest CT scans by comparing the dose, examination time, and image quality by applying Helical mode, High-pitch mode, and Volume Axial mode to minimize the radiation exposure and obtain high diagnostic value. Revolution (GE Healthcare, Wisconsin USA) was used to divide PBU-70 phantom into Helical mode, High-pitch mode, and Volume Axial mode. After acquiring images, ROI is set for each image, heart, bone, lung, and back-ground air, and the average value is obtained by measuring CT number (HU) and noise (SD). SNR and CNR were measured and compared with DLP values provided directly by the equipment. Determining statistical significance Statistical analysis was performed using ONE-WAY-ANAOVA using SPSS 21.0. In this experiment, it was possible to inspect at a short time without deterioration of image quality with the lowest dose when using volume axial mode. Although the detector coverage of 16 cm is limited to all pediatric chest CT scans, it is recommended to be actively used in pediatric patients, and further study is needed to apply other test sites in volume axial mode.

A Clinical Study on Herbal Medicine Threapy Treating Nasal Polyps (비용종(鼻茸腫)(Nasal polyp) 한방(韓方) 치험예(治驗例)에 관(關)한 임상적(臨床的) 연구(硏究))

  • Lee Hai-Ja;Park Eun-Jung
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.13 no.1
    • /
    • pp.191-204
    • /
    • 1999
  • Background: Nasal polyps are benign mass of nasal mucose, chronic sinusitis are swelling of nasal mucose, so nasal polyps and chronic sinusitis take a place at the same time. Nasal polyps are located lateral wall of nose, middle meatus, between middle nasal concha and inferior nasal concha. Objective: To demonstrate the effect of herbal medicine therapy in the chronic sinusitis and nasal polyps before and after treatment using computed tomography (CT). To compared before and after treatment of otitis media using earscope. Materials and methods: Five patients (4 mail and 1 femail) treated in our hospital between August 1998 and July 1999 were studied. Ages ranged from 9 to 23 years (mean age:13 years). All patients had a underlying family history, and past history(allergy or sinusitis of parents or brothers). Illness period was from 1 to 36 months (mean period:10.5 month). To ascertain the efficacy of treatment, CT were checked out. In the CT, three images were obtained 2cm interval on the coronal and axial plan. We classified treatment period into the type of allergic disease. Gamihyunggyeyungyo-tang was administered mainly. Gamigwaghyangjeungki-san, Gamizwakwi-eum and Gamihyangso-san were administered for through oral route additional symptoms. Results: Treatment period was from 126 to 157 days (mean period:140.7 days). To 3 patients with chronic sinusitis and nasal polyp, treatment period was 140.7 days, to 2 patients with otitis media and chronic sinusitis and nasal polyp, treatment period was 141.5 days. So they had no significance. Not nasal polyp from middle meatus, but also polypoid mucosal change of maxillary sinus is polyps Conclusion: We know that herbal medicine therapy is the effective treatment of pediatric chronic sinusitis and otitis media using earscope and CT. Herbal medicine therapy was effective in increasing immunity, inhibiting allergic reaction and inflammation of respiratory system. we practice ECP(eosinophil cataionic protein) and MAST examination, objectify herbal medicine therapy.

  • PDF

The Clinical Value of Dual Time Point F-18 FDG PET/CT Imaging for the Differentiation of Colonic Focal Uptake Lesions (장관 내 국소 섭취증가 병소의 감별에 있어 추가 지연 F-18 FDG PET/CT의 임상적 유용성)

  • Kim, Jin-Suk;Lim, Seok-Tae;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.309-316
    • /
    • 2009
  • Purpose: F-18 FDG can be accumulated in the liver, bowel, kidney, urinary tract, and muscles physiologically. The aim of this study was to evaluate the clinical value of dual time point 18F-FDG PET /8 imaging for the differentiation of the colonic focal uptake lesions. Materials and Methods: One hundred thirty two patients (M:F = 77:55, Age 62.8$\pm$11.6 years) underwent $^{18}$F-FDG PET/CT at two time points, prospectively: early image at 50-60 min and delayed image at 4-4.5 hours after the intravenous injection of $^{18}$F-FDG. Focally increased uptake lesions on early images but disappeared or shifted on delayed images defined a physiological uptake. For the differential evaluation of persistent focal uptake lesions on delayed images, colonoscopy and histopathologic examination were performed. SUVmax changes between early and delayed images were also compared. Results: Among the 132 patients, 153 lesions of focal colonic uptake were detected on early images of $^{18}$F-FDG PET/CT. Of these, 72 (47.1%) lesions were able to judge with physiological uptake because the focal increased uptake disappeared from delayed image. Among 81 lesions which was showed persistent increased uptake in delayed image, 61 (75.3%) lesions were confirmed as the malignant tumor and 14 (17.3%) lesions were confirmed as the benign lesions including adenoma and inflammatory disease. Remaining 6 (7.4%) lesions were confirmed as the physiological uptake because there was no particular lesion in the colonoscopy. In the malignant lesions, the calculated dual time point change for SUVmax ($\Delta$%SUVmax) was 20.8$\pm$18.7%, indicating a significant increase in SUVmax between the two point (p<0.01). In contrast, the change in SUVmax for the non-malignant lesions including benign lesions and physiological uptake was -13.7%$\pm$24.2%. For the differentiation of the malignant and non-malignant focal colonic uptake lesions, $\Delta$%SUVmax was the most effective parameter, and the cut-off value using -5% provided the best sensitivity, specificity, and accuracy. Conclusion: The dual time point $^{18}$F-FDG PET/CT imaging with SUVmax change evaluation could be an important noninvasive method for the differentiation of malignant and benign focal colonic uptake lesions including physiologic uptake.

Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope (방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가)

  • Jeong, Jae Hoon;Lee, Chung Wun;You, Yeon Wook;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Purpose Radiation exposure management has been strictly regulated for the radiation workers, but there are only a few studies on potential risk of radiation exposure to non-radiation workers, especially nurses in a general ward. The present study aimed to estimate the exact total exposure of the nurse in a general ward by close contact with the patient undergoing nuclear medicine examinations. Materials and Methods Radiation exposure rate was determined by using thermoluminescent dosimeter (TLD) and optical simulated luminescence (OSL) in 14 nurses in a general ward from October 2015 to June 2016. External radiation rate was measured immediately after injection and examination at skin surface, and 50 cm and 1 m distance from 50 patients (PET/CT 20 pts; Bone scan 20 pts; Myocardial SPECT 10 pts). After measurement, effective half-life, and total radiation exposure expected in nurses were calculated. Then, expected total exposure was compared with total exposures actually measured in nurses by TLD and OSL. Results Mean and maximum amount of radiation exposure of 14 nurses in a general ward were 0.01 and 0.02 mSv, respectively in each measuring period. External radiation rate after injection at skin surface, 0.5 m and 1 m distance from patients was as following; $376.0{\pm}25.2$, $88.1{\pm}8.2$ and $29.0{\pm}5.8{\mu}Sv/hr$, respectively in PET/CT; $206.7{\pm}56.6$, $23.1{\pm}4.4$ and $10.1{\pm}1.4{\mu}Sv/hr$, respectively in bone scan; $22.5{\pm}2.6$, $2.4{\pm}0.7$ and $0.9{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. After examination, external radiation rate at skin surface, 0.5 m and 1 m distance from patients was decreased as following; $165.3{\pm}22.1$, $38.7{\pm}5.9$ and $12.4{\pm}2.5{\mu}Sv/hr$, respectively in PET/CT; $32.1{\pm}8.7$, $6.2{\pm}1.1$, $2.8{\pm}0.6$, respectively in bone scan; $14.0{\pm}1.2$, $2.1{\pm}0.3$, $0.8{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. Based upon the results, an effective half-life was calculated, and at 30 minutes after examination the time to reach normal dose limit in 'Nuclear Safety Act' was calculated conservatively without considering a half-life. In oder of distance (at skin surface, 0.5 m and 1 m distance from patients), it was 7.9, 34.1 and 106.8 hr, respectively in PET/CT; 40.4, 199.5 and 451.1 hr, respectively in bone scan, 62.5, 519.3 and 1313.6 hr, respectively in myocardial SPECT. Conclusion Radiation exposure rate may differ slightly depending on the work process and the environment in a general ward. Exposure rate was measured at step in the general examination procedure and it made our results more reliable. Our results clearly showed that total amount of radiation exposure caused by residual radioactive isotope in the patient body was neglectable, even comparing with the natural radiation exposure. In conclusion, nurses in a general ward were much less exposed than the normal dose limit, and the effects of exposure by contacting patients undergoing nuclear medicine examination was ignorable.

  • PDF

The Value of Calcium-scoring CT for Ischemic Cardiovascular Disease Screening (허혈성 심혈관 질환 선별을 위한 Calcium-scoring CT의 유용성)

  • Oh, Jung-Hoan;An, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.69-78
    • /
    • 2009
  • The cardiovascular disease has been known as a common cause of death for a long time in the west. The eating habits of Asia, including Korea, have changed recently, so that this disease is also a problem in Asia now. Annual Report on the Cause of Death Statistics from 1996 to 2006 reported that the cardiovascular disease would become the number one cause of death in the next $5{\sim}10$ years. Therefore we realize that more accurate examination is required. The aim of this study was to investigate the accuracy of Calcium-scoring CT and the relationship between risk factor and quantitative scores of Calcium-scoring CT. Through this study we expect that the national public health will be improved. Seventy patients with chest pain were chosen at random. The patients were undergone both coronary CT antigraphy and Calcium - scoring CT at G hospital in Incheon from February 1 to June 30, 2008. The result of the Calcium-scoring CT showed its usefulness for Ischemic cardiovascular disease, with an accuracy similar to that of exercise/pharmacologic stress or ECG when it is difficult for a patient to exercise due to joint problems, aging or for other reasons.

  • PDF

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

CT Observation of Alloplastic Materials Used in Blow Out Fracture (안와골절 정복술에 사용된 인공삽입물의 전산화단층촬영 추적관찰)

  • Lee, Won;Kang, Dong-Hee
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.380-384
    • /
    • 2010
  • Purpose: Distinguishing different types of implants and assessing the position and size of implants by radiologic exam after orbital wall reconstruction is important in determining the surgery outcome and forecasting prognosis. We observed time-dependent density changes in three types of implants (porous polyethylene, resorbing plate and titanium mesh plate) by performing facial bone CT after orbital wall reconstructions. Methods: A total of 32 patients, who had underwent orbital wall fracture surgery from October 2006 to March 2009 and received facial bone CT as outpatients at 1 postoperative year were included in the study. Follow-up facial bone CT was performed on the patients pre- operatively, 1 month post-operatively, and 1 year post-operatively to observe the status of the orbital implants. Medpor $^{(R)}$ (Porex Surgical, Inc., Newnan, Ga.) was used as porous polyethylene and followed-up in 14 cases; for resorbing plate, Synthes mesh plate (Synthes, Oberdorf, Switzerland) was used in the reconstruction, and followed-up in 11 cases; and titanium mesh plate usage was followed-up in 7 cases. Computed tomographic scan (CT) and water's view were done for radiography, and hounsfield unit (HU) was used to compare density of those facial bone CT. Wilcoxon signed rank test was applied to statistically verify measurement difference in each group of hounsfield units. Results: Facial bone CT examination performed in 1 month post-operative showed that the density of porous polyethylene, resorbing plate and titanium mesh plate were -42.07, 105.67 and 539.48 on average, respectively. Among the three types of implants, titanium mesh plate showed the highest density due to its radiopaque feature. Following up the density of three types of implants in CT during 1 year after the orbital wall fracture surgery, the density of porous polyethylene increased in 10.52 House Field Units and the resorbing plate was decreased in 26.87 HouseField Units. There were no significant differences between densities in 1 month post-operatively and 1 year post-operatively in each group ($p{\geq}0.05$). Conclusion: We performed facial bone CT on patients with orbital fractures during follow-up period, distinguishing the types of implants by the different concentration of implant density, and the densities showed little change even at 1 year post-operative. To observe how implant densities change in facial bone CT, further studies with longer follow-up periods should be carried out.

False-Negative Results of Real-Time Reverse-Transcriptase Polymerase Chain Reaction for Severe Acute Respiratory Syndrome Coronavirus 2: Role of Deep-Learning-Based CT Diagnosis and Insights from Two Cases

  • Dasheng Li;Dawei Wang;Jianping Dong;Nana Wang;He Huang;Haiwang Xu;Chen Xia
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.505-508
    • /
    • 2020
  • The epidemic of 2019 novel coronavirus, later named as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is still gradually spreading worldwide. The nucleic acid test or genetic sequencing serves as the gold standard method for confirmation of infection, yet several recent studies have reported false-negative results of real-time reverse-transcriptase polymerase chain reaction (rRT-PCR). Here, we report two representative false-negative cases and discuss the supplementary role of clinical data with rRT-PCR, including laboratory examination results and computed tomography features. Coinfection with SARS-COV-2 and other viruses has been discussed as well.

Operation Efficiency Estimation of PET/CT Center by Work Form and Exposure Dose (근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가)

  • Kweon, Oh-Jin;Jung, Su-Hee;Baek, Seung-Chan;Kim, Kyeong-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.93-97
    • /
    • 2009
  • Purpose: Recognize circulation work system and fixing work system's merits and demerits that is enforced in operation of PET/CT center in sudden increase recently. Wish to estimate connectivity degree of individual exposure dose and PET/CT working that is managed periodically through this and look for operation efficiency of PET/CT center. Materials and Methods: (1) Find interrelationship of length of service to be individual exposure dose and PET/CT through TLD interpretation. Specially, evaluate on the basis of data of 2.5 years until 2 quarters 2006~2008 year that show patient increase rapidly the latest. (2) Recognize what countermeasure is evaluating problems happened at circulation work system and fixing work system. Results: Patient examination's number was 14,674 items until 2 quarters 2006~2008 year, and the $^{18}F$-FDG average injection amount was 461.5 MBq. 2 people of 10 radiotechnologist did fixing work PET area and GAMMA area each, and 8 people did circulation work of 3 times for 2.5 years. Average exposure dose that PET area and Gamma area's circulation men in service receive was 1.32 mSv, and PET area men in services came out average 0.825 mSv high than Gamma area men in services. Nurse's exposure dose is 0.28 mSv, and next 2 reason is conjectured. One is contact with patient that medicate $^{18}F$-FDG injection, and another is consultation about patient's next time schedule after examination end. Although exposure dose's amount is not much, is expected to consider continuation work possibility by exposure dose in case is a nurse with pregnancy possibility. Also, $^{131}I$-isotope therapy area's radiotechnologist that use capsule appeared by 0.12 mSv and a nuclear medicine doctor appeared by exposure dose that is less of 0.11 mSv. Conclusions: In case do PET/CT center circulation work after a long time, connoted danger that most men in service is consecutiveness deficiency of business and individual exposure dose increase at early 1 month. Specially, way for individual exposure dose's decrease should be considered. Also, need to evaluate abhorrent work form for efficient work system introduction, and enforce circulation and fixing work suggestion suitable shift working. Finally, must make normalized business guide and so on to prevent circulation work people's business efficiency decline.

  • PDF

Clinical Predictors of Survival in Idiopathic Pulmonary Fibrosis

  • Kim, Ji Hye;Lee, Jin Hwa;Ryu, Yon Ju;Chang, Jung Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.73 no.3
    • /
    • pp.162-168
    • /
    • 2012
  • Background: Idiopathic pulmonary fibrosis (IPF) is a progressive disease. Effective treatment is not currently available and the prognosis is poor. The aim of our study was to identify clinical predictors of survival in patients with IPF. Methods: By using medical record database of a university hospital, we reviewed the records of patients who had been diagnosed as having IPF from January 1996 through December 2007. Results: Among 89 patients considered as having interstitial lung disease (ILD) on computed tomography (CT) of the chest, 22 were excluded because of the diagnosis of other ILDs or connective tissue disease, and finally, 67 met the criteria of IPF. The mean age at the diagnosis of IPF was 70 years (range, 41~87 years) and 43 (64%) were male. The mean survival time following the diagnosis of IPF was 40 months (range, 0~179 months). Among them, 28 cases were diagnosed as the progressive state of IPF on the follow-up CT examination, and the mean duration between diagnosis of IPF and progression was 31 months. Multivariate analysis using Cox regression model revealed that body mass index (BMI) less than 18.5 $kg/m^2$ (p=0.030; hazard ratio [HR], 12.085; 95% confidence interval [CI], 1.277~114.331) and CT progression before 36 months from the diagnosis of IPF (p=0.042; HR, 13.564; 95% CI, 1.101~167.166) were independently associated with mortality. Conclusion: Since low BMI at the diagnosis of IPF and progression on follow-up CT were associated with poor prognosis, IPF patients with low BMI and/or progression before 36 months following the diagnosis should be closely monitored.