• Title/Summary/Keyword: CT Examination Time

Search Result 135, Processing Time 0.131 seconds

REPORT OF THE MANAGEMENT OF GUNSHOT WOUNDS TO THE LEFT FACE (산탄총에 의한 좌측 안면부 손상 환자의 치험례 (증례보고))

  • Kim, Il-Kyu;Lee, Sang-Sun;Oh, Sung-Sup;Choi, Jin-Ho;Kim, Hyung-Don;Oh, Nam-Sik
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.2
    • /
    • pp.224-227
    • /
    • 2000
  • Gunshot wounds to the face are often dramatic at the time of presentation. Although care must be individualized, protocol approach helps the clinician rapidly evaluate patient and plan treatment. Early X-ray films help to determine the precise trajectory. Rapid neurologic assessment and early CT scanning based on physical examination ot trajectory will allow for identification of even occult injuries early. Lead poisoning arising from bullet lead in the synovial cavity of the hip, synovial cavity of the chest and pleural space have been reported. A combination of surgical debridement and chelation therapy with oral succimer produce a satisfactory outcome. We have managed a patient with Lt facial gunshot wound and Lt mandible angle fracture by open reduction of angle fracture and surgical removal of remnant bullet and medially advanced cheek skin flap. We have obtained good result and report this case with review of literatures.

  • PDF

Stroke Disease Identification System by using Machine Learning Algorithm

  • K.Veena Kumari ;K. Siva Kumar ;M.Sreelatha
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.11
    • /
    • pp.183-189
    • /
    • 2023
  • A stroke is a medical disease where a blood vessel in the brain ruptures, causes damage to the brain. If the flow of blood and different nutrients to the brain is intermittent, symptoms may occur. Stroke is other reason for loss of life and widespread disorder. The prevalence of stroke is high in growing countries, with ischemic stroke being the high usual category. Many of the forewarning signs of stroke can be recognized the seriousness of a stroke can be reduced. Most of the earlier stroke detections and prediction models uses image examination tools like CT (Computed Tomography) scan or MRI (Magnetic Resonance Imaging) which are costly and difficult to use for actual-time recognition. Machine learning (ML) is a part of artificial intelligence (AI) that makes software applications to gain the exact accuracy to predict the end results not having to be directly involved to get the work done. In recent times ML algorithms have gained lot of attention due to their accurate results in medical fields. Hence in this work, Stroke disease identification system by using Machine Learning algorithm is presented. The ML algorithm used in this work is Artificial Neural Network (ANN). The result analysis of presented ML algorithm is compared with different ML algorithms. The performance of the presented approach is compared to find the better algorithm for stroke identification.

The Use of Transabdominal Ultrasound in Inflammatory Bowel Disease

  • Jiro Hata;Hiroshi Imamura
    • Korean Journal of Radiology
    • /
    • v.23 no.3
    • /
    • pp.308-321
    • /
    • 2022
  • Transabdominal ultrasound (TAUS) is useful in all aspects of lesion screening, monitoring activity, or treating/diagnosing any related complications of inflammatory bowel disease. Its ability to screen or diagnose complications is almost the same as that of other methods, such as CT or MRI. Moreover, its noninvasiveness makes it a first-line examination method. A TAUS image depicting ulcerative colitis will show large intestinal wall thickening that is continuous from the rectum, which is mainly due to mucosal layer thickening, while for Crohn's disease, a TAUS image is characterized by a diversity in the areas affected, distribution, and layer structure. Indicators of activity monitoring include wall thickness, wall structure, and vascular tests that use Doppler ultrasound or contrast agents. While all of these have been reported to be useful, at this time, no single parameter has been established as superior to others; therefore, a comprehensive evaluation of these parameters is justified. In addition, evaluating the elasticity of lesions using elastography is particularly useful for distinguishing between fibrous and inflammatory stenoses. However, the lack of objectivity is the biggest drawback of using ultrasound. Standardizing and popularizing the ultrasound process will be necessary, including scanning methods, equipment settings, and image analysis.

Bone Metastasis in Gastric Cancer Patients

  • Ahn, Jae-Bong;Ha, Tae-Kyung;Kwon, Sung-Joon
    • Journal of Gastric Cancer
    • /
    • v.11 no.1
    • /
    • pp.38-45
    • /
    • 2011
  • Purpose: Bone metastasis from stomach cancer occurs only rarely and it is known to have a very poor prognosis. This study examined the clinical characteristics and prognosis of patients who were diagnosed with stomach cancer and bone metastasis. Materials and Methods: The subjects were 19 patients who were diagnosed with stomach cancer at Hanyang University Medical Center from June 1992 to August 2010 and they also had bone metastasis. The survival rate according to many clinicopathologic factors was retrospectively analyzed. Results: 11 patients out of 18 patients (61%) who received an operation were in stage IV and the most common bone metastasis location was the spine. Bone scintigraphy was mostly used for diagnosing bone metastasis and PET-CT and magnetic resonance imaging were used singly or together. The serum alkaline phosphatase at the time of diagnosis had increased in 12 cases and there were clinical symptoms (bone pain) in 16 cases. Treatment was given to 14 cases and it was mostly radiotherapy. There were 2 cases of discovering bone metastasis at the time of diagnosing stomach cancer. The interval after operation to the time of diagnosing bone metastasis for the 18 cases that received a stomach cancer operation was on average $14.9{\pm}17.3$ months and the period until death after the diagnosis of bone metastasis was on average $3.8{\pm}2.6$ months. As a result of univariate survival rate analysis, the group that was treated for bone metastasis had a significantly better survival period when the bone metastasis was singular rather than multiple, as compared to the non-treatment group, yet both factors were not independent prognosis factors on multivariate survival analysis. Conclusions: An examination to confirm the status of bone metastasis when conducting a radio-tracer test after the initial diagnosis and also after an operation is needed for stomach cancer patients, and bone scintigraphy is the most helpfully modality. Making the diagnosis at the early stage and suitable treatments are expected to enhance the survival rate and improve the quality of life even for the patients with bone metastasis.

Analyses Using Micro-CT Scans and Tissue Staining on New Bone Formation and Bone Fusion According to the Timing of Cranioplasty via Frozen Autologous Bone Flaps in Rabbits : A Preliminary Report

  • Shin, Hee Sup;Lee, Deok-Won;Lee, Seung Hwan;Koh, Jun Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.4
    • /
    • pp.242-249
    • /
    • 2015
  • Objective : The timing of cranioplasty and method of bone flap storage are known risk factors of non-union and resorption of bone flaps. In this animal experimental study, we evaluated the efficacy of cranioplasty using frozen autologous bone flap, and examined whether the timing of cranioplasty after craniectomy affects bone fusion and new bone formation. Methods : Total 8 rabbits (male, older than 16 weeks) were divided into two groups of early cranioplasty group (EG, 4 rabbits) and delayed cranioplasty group (DG, 4 rabbits). The rabbits of each group were performed cranioplasty via frozen autologous bone flaps 4 weeks (EG) and 8 weeks (DG) after craniectomy. In order to obtain control data, the cranioplasty immediate after craniectomy were made on the contralateral cranial bone of the rabbits (control group, CG). The bone fusion and new bone formation were evaluated by micro-CT scan and histological examination 8 weeks after cranioplasty on both groups. Results : In the micro-CT scans, the mean values of the volume and the surface of new bone were $50.13{\pm}7.18mm^3$ and $706.23{\pm}77.26mm^2$ in EG, $53.78{\pm}10.86mm^3$ and $726.60{\pm}170.99mm^2$ in DG, and $31.51{\pm}12.84mm^3$ and $436.65{\pm}132.24mm^2$ in CG. In the statistical results, significant differences were shown between EG and CG and between DG and CG (volume : p=0.028 and surface : p=0.008). The histological results confirmed new bone formation in all rabbits. Conclusion : We observed new bone formation on all the frozen autologous bone flaps that was stored within 8 weeks. The timing of cranioplasty may showed no difference of degree of new bone formation. Not only the healing period after cranioplasty but the time interval from craniectomy to cranioplasty could affect the new bone formation.

The Evaluation of Clinical Usefulness on Application of Half-Time Acquisition Factor in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 Half-Time 획득 인자 적용에 따른 임상적 유용성 평가)

  • Lee, Dong-Hun;Yoo, Hee-Jae;Lee, Jong-Hun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.192-198
    • /
    • 2008
  • Purpose: The scan time reduction helps to yield more accurate results and induce the minimization of patient's motion. Also we can expect that satisfaction of examination will increase. Nowdays medical equipment companies have developed various programs to reduce scan time. We used Onco. Flash (Pixon method, SIEMENS) that is an image processing technique gated cardiac blood pool scan and going to evaluate its clinical usefullness. Materials and Method: We analyzed the 50 patients who were examined by gated blood pool scan in nuclear medicine department of Asan Mediacal Center from June $20^{th}$ 2008 to August $14^{th}$ 2008. We acquired the Full-time (6000 Kcounts) and Half-time (3000 Kcounts) LAO image in same position. And we acquired LVEF values ten times from Full-time, Half-time images acquired by the image processing technique and analyzed its mean and standard deviation values. To estimate LVEF in same conditions, we set automatic location of the LV ROI and background ROI based on same X and Y-axis. Also we performed blinding tests to physician. Results: After making a quantitative analysis of the 50 patients EF values, each mean${\pm}$standard deviation is shown at Full-time image $68.12{\pm}7.84%$, Half- time (acquired by imaging processing technique) $68.49{\pm}8.73%$. In the 95% confidence limit, there was no statistically significant difference (p>0.05). After blinding test with a physician for making a qualitative analysis, there was no difference between Full-time image and Half-time image acquired by the image processing technique for observing LV myocardial wall motion. Conclusion: Gated cardiac blood pool scan has been reported its relatively exact EF measured results than ultrasound or CT. But gated cardiac blood pool scan takes relatively longer time than other exams and now it needs to improve time competitive power. If we adapt Half-time technique to gated cardiac blood pool scintigraphy based on this study, we expect to reduce possible artifacts and improve accessibility as well as flexibility to exam. Also we expect patient's satisfaction.

  • PDF

Study of the Difference in Residual Amounts according to the Method of Securing Intravenous Injections and the Dose of Physiological Saline during 18F-FDG Administration (18F-FDG 투여 시 정맥주사 확보 방법 및 생리식염수 용량에 따른 잔류량의 차이에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.95-102
    • /
    • 2022
  • This study compares the difference between the remaining amount in syringes according to injection method and the dose of physiological saline when the radiopharmaceutical 18F-FDG isotope is injected into patients who visited the hospital for PET examination. After performing a CT or MRI using a contrast medium when 18F-FDG was injected into 40 patients who came to the hospital for PET examination without removing the 3-way, the radioactivity remaining in the syringe and the 3-way was measured and the dose of radioactivity confirmed. At this time, 20 patients were divided into different dose groups of physiological saline. Another injection method was used to compare the remaining amount of the syringe and the difference in the remaining amount according to the amount of physiological saline when the injection was performed with an extension. After an injection of 18F-FDG, the actual administered dose was confirmed by measuring the radioactivity remaining in the syringe and the 3-way or extension with a calibrator. As a result of measuring the radioactivity of the syringe before administering the radiopharmaceutical and the radioactivity of the syringe and the 3-way or extension after administration, the 3-way injection method in 10 cc's of physiological saline had the lowest residual amount. The remaining amount increased in the order of the extension to 10 cc's of saline and the 3-way to 5 cc's of saline. Likewise, the 5 cc's saline solution and the extension injection method demonstrated the highest residual amounts. The residual difference with the lowest level of remaining injection method was found to be 0.053 mCi. It was found that in a PET examination, by considering the radioactivity remaining in the 3-way and extension and by adjusting the dose of physiological saline, if the intended dose to be administered to the actual patient is determined, it is possible to administer the radiopharmaceutical to the patient more accurately.

Longitudinal Evaluation of Lung Function Associated with Emphysema in Healthy Smokers (건강한 흡연자에서 폐기종의 유무에 따른 폐기능 변화)

  • Sim, Yun-Su;Ham, Eun-Jae;Choi, Kyu-Yong;Lee, Suk-Young;Kim, Seok-Chan;Kim, Young-Kyoon;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • Background: Smoking reduces pulmonary function and induces various lung diseases. Recently, the rate of emphysema detection has increased due to lung cancer screening with low-dose chest computed tomography (CT). The purpose of this study was to evaluate changes in lung function associated with emphysema in healthy smokers. Methods: One hundred and ninety one healthy smokers, who had undergone a low-dose chest CT (LDCT) scan as part of lung cancer screening and had revisited the health center after a median 23.9 months' time, were recruited into this study. The severity of emphysema was calculated by the direct observation of a radiologist and a pulmonologist indipendently. Longitudinal changes in lung function according to emphysema based on LDCT and type of smoker was analyzed. Results: Of the participants in this study, 25% of healthy smokers had emphysema, which was mild in severity, in older patients (p=0.003) and in heavy smokers (p<0.001). $FEV_1/FVC$ and FEF25-75% were decreased in current smokers with emphysema (p=0.001 and p=0.009, respectively) and without emphysema (p=0.001 and p=0.042). Although lung function was not decreased in ex-smokers without emphysema, $FEV_1/FVC$ and FEF25-75% were decreased in ex-smoker with emphysema (p=0.020 and p=0.010). Conclusion: Upon examination with LDCT, the prevalence of emphysema was higher in healthy smokers was than in non-smokers. Lung function was diminished in smokers with emphysema, in spite of former smoker.

Optimization of the Empirical Method to the Enhancement Image of the Four Chambers at the Same Time in the Pediatric Cardiac Computed Tomography (소아 심장 전산화단층촬영 검사에서 4 chamber의 동시 조영증강 영상에 대한 최적화 방안)

  • Park, Chanhyuk;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.279-285
    • /
    • 2014
  • This study is to have dose reduction and minimization of excessive use of contrast medium in the pediatric cardiac computed tomography and to suggest the optimization plan to acquire the enhancement image of the 4 chambers at the same time by formulating scan delay time in empirical method with considering variables such as contrast medium injection velocity and cardiac approaching time. Quantitative, qualitative and dose assessment were carried out for 30 pediatric patients who had taken the cardiac examination. In conclusion, image enhancement in 4 chambers of the cardiac shows over 300 HU which is proper to pediatric cardiac reading by applying the empirical method with calculating scan delay time according to weight and contrast medium volume and injection velocity. Qualitative image assessments in confidence sharpness and noise have excellence qualitatively. Exposure dose to pediatrics also decreases precisely. Therefore this study is judged to take a important role of making optimization images with advantages of dose reduction and less side effects caused by it's excessive use in clinic.

Asymmetrical diffuse Interstitial Lung Lesions with Multiple Lymphadenopathy (다발성 임파절 이상증을 동반한 비대칭적 폐 간질성 병변)

  • Lee, Kyung Sang;Yang, Suck Chul;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo;Lee, Jung Hee;Kim, Hyuk;Choi, Yo Won;Jeon, Seok Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.651-656
    • /
    • 1996
  • We have experienced a case of sarcoidosis appearing asymmetrical diffuse interstitial lung lesions with multiple lymphadenopathy. This patient was a 57 year-old female who had been in good health until 2 months ago. At that time she noted the onset of an exertional dyspnea and weakness. Pulmonary function tests showed moderate obstructive pattern with mild decreased DLco. In the chest CT, multiple lymphadenopathy with small nodular lesions are scattered, and the impression was a metastatic lymph nodes with lymphangitic carcinomatosis. In bronchofiberscopy, we noted luminal narrowing by extrinsic compression in the right middle and lower lobe bronchi. And microscopic examination of by bronchofiberscopic biopsy showed chronic inflammation. Thus we performed subcarinal and tight supraclaviclar lymph nodes aspiration biopsy cytology, and that revealed class 0 and class 1, respectively. Finally, we performed an excisional biopsy for the right scalene lymph node, which revealed the specimen as a noncaseating granuloma. The angiotensin convecting enzyme level was overt two folds compared to normal value. And the patient had negative PPD skin test and hyperglobulinemia. After 18 weeks treatment with prednisone, the signs and symptoms which the patient clad suffered from, disappeared.

  • PDF