• Title/Summary/Keyword: CT Examination Time

Search Result 135, Processing Time 0.031 seconds

A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination (전산화단층촬영 소아 흉부검사에서 관전압의 변화에 따른 화질변화에 관한 연구)

  • Kim, Gu;Kim, Gyeong Rip;Sung, Soon Ki;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.503-508
    • /
    • 2019
  • In short a binary value according to a change in the tube voltage by using one of VOLUME AXIAL MODE of scanning techniques of chest CT image quality evaluation in order to obtain high image and to present the appropriate tube voltage. CT instruments were GE Revolution (GE Healthcare, Wisconsin USA) model and Phantom used Pediatric Whole Body Phantom PBU-70. The test method was examined in Volume Axial mode using the pediatric protocol used in the Y university hospital of mass-produced material. The tube voltage was set to 70kvp, 80kvp, 100kvp, and mAs was set to smart mA-ODM. The mean SNR difference of the heart was $-4.53{\pm}0.26$ at 70 kvp, $-3.34{\pm}0.18$ at 80 kvp, $-1.87{\pm}0.15$ at 100 kvp, and SNR at 70 kvp was about -2.66 higher than 100 kvp and statistically significant (p<0.05) In the Lung SNR mean difference analysis, $-78.20{\pm}4.16$ at 70 kvp, $-79.10{\pm}4.39$ at 80 kvp, $-77.43{\pm}4.72$ at 100 kvp, and SNR at 70 kvp at about -0.77 higher than 100 kvp were statistically significant. (p<0.05). Lung CNR mean difference was $73.67{\pm}3.95$ at 70 kvp, $75.76{\pm}4.25$ at 80 kvp, $75.57{\pm}4.62$ at 100 kvp and 20.9 CNR at 80 kvp higher than 70 kvp and statistically significant (p<0.05) At 100 kvp of tube voltage, the SNR was close to 1 while maintaining the quality of the heart image when 70 kvp and 80 kvp were compared. However, there is no difference in SNR between 70 kvp and 80 kvp, and 70 kvp can be used to reduce the radiation dose. On the other and, CNR showed an approximate value of 1 at 70 kvp. There is no difference between 80 kvp and 100 kvp. Therefore, 80 kvp can reduce the radiation dose by pediatric chest CT. In addition, it is possible to perform a scan with a short scan time of 0.3 seconds in the volume axial mode test, which is useful for pediatric patients who need to move or relax.

Dissecting Aneurysm of Vertebral Artery Manifestating as Contralateral Abducens Nerve Palsy

  • Jeon, Jin Sue;Lee, Sang Hyung;Son, Young-Je;Chung, Young Seob
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.3
    • /
    • pp.194-196
    • /
    • 2013
  • Isolated abducens nerve paresis related to ruptured vertebral artery (VA) aneurysm is rare. It usually occurs bilaterally or ipsilaterally to the pathologic lesions. We report the case of a contralateral sixth nerve palsy following ruptured dissecting VA aneurysm. A 38-year-old man was admitted for the evaluation of a 6-day history of headache. Abnormalities were not seen on initial computed tomography (CT). On admission, the patient was alert and no signs reflecting neurologic deficits were noted. Time of flight magnetic resonance angiography revealed a fusiform dilatation of the right VA involving origin of the posterior inferior cerebellar artery. The patient suddenly suffered from severe headache with diplopia the day before the scheduled cerebral angiography. Neurologic examination disclosed nuchal rigidity and isolated left abducens nerve palsy. Emergent CT scan showed high density in the basal and prepontine cistern compatible with ruptured aneurismal hemorrhage. Right vertebral angiography illustrated a right VA dissecting aneurysm with prominent displaced vertebrobasilar artery to inferiorly on left side. Double-stent placement was conducted for the treatment of ruptured dissecting VA aneurysm. No diffusion restriction signals were observed in follow-up magnetic resonance imaging of the brain stem. Eleven weeks later, full recovery of left sixth nerve palsy was documented photographically. In conclusion, isolated contralateral abducens nerve palsy associated with ruptured VA aneurysm may develop due to direct nerve compression by displaced verterobasilar artery triggered by primary thick clot in the prepontine cistern.

Clinical Features and Treatment Outcomes of Pediatric Deep Neck Infection (소아 심경부 감염의 임상적 고찰)

  • Moon, Tae-Hyun;Lee, Do-Joon;Park, Byung-Kuhn;Lee, Sang-Joon;Chung, Phil-Sang
    • Korean Journal of Bronchoesophagology
    • /
    • v.16 no.2
    • /
    • pp.115-120
    • /
    • 2010
  • Background: Pediatric deep neck infection can cause critical complications in that they are seldom able to verbalize symptoms or cooperate with physical examination. The objective of this study is to identify the clinical characteristics according to age. Material and Method: A retrospective study was performed on 26 cases with pediatric deep neck infection during 12 years. Patients were classified infancy group (1-7 yr, 19.2%), preschool age group (7-15 yr, 30.8%) and school age group (15 yr-, 50%). We analyzed the age, sex, sites of abscess, predisposing factors, symptoms and compared onset, hospital date, laboratory and outcomes at each group. Results: In pediatric patients with deep neck infection, the age distribution was 18 males (69.2%) and 8 females (30.8%), the mean age was 7.4 years. The most common infection site was the anterior cervical triangle and submandibular space (19.2%). The most commonly known associated preceding disease was upper viral infection (34.6%), but we could not find the preceding diseases in most of cases (50%). Neck swelling (69.2%) was the most frequent symptom. The mean age of patients who performed neck CT was 8.23 years and neck US was 2.75 years. The younger patients were preferred to perform the neck US than the neck CT (p=0.022). The mean time from disease onset to admission was 9 days in the infancy, 5.5 days in the preschool aged and 5 days in the school aged group. The surgical treatment was performed in 30.8% of school aged, 62.5% of preschool aged and 100% of infancy group. Surgical treatment was preferred to younger patients (p=0.026). Conclusion: Abscess sites, size, and antibiotics susceptibility and especially patient age should be carefully considered in treating pediatric deep neck infection.

  • PDF

Accuracy Analysis of Magnetic Resonance Angiography and Computed Tomography Angiography Using a Flow Experimental Model

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Park, Cheol-Soo;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.40-46
    • /
    • 2015
  • This study investigated the accuracy of magnetic resonance angiography (MRA) and computed tomography angiography (CTA) in terms of reflecting the actual vascular length. Three-dimensional time of flight (3D TOF) MRA, 3D contrast-enhanced (CE) MRA, volume-rendering after CTA and maximum intensity projection were investigated using a flow model phantom with a diameter of 2.11 mm and area of $0.26cm^2$. 1.5 and 3.0 Tesla devices were used for 3D TOF MRA and 3D CE MRA. CTA was investigated using 16 and 64 channel CT scanners, and the images were transmitted and reconstructed by volume-rendering and maximum intensity projection, followed by conduit length measurement as described above. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s using the 3.0 Tesla apparatus, and $2.57{\pm}0.07mm$ with a velocity of 71.5 cm/s using the 1.5 Tesla apparatus; both images were magnified from the actual measurement of 2.11 mm. The measurement with the 16 channel CT scanner was smaller ($3.83{\pm}0.37mm$) than the reconstructed image on maximum intensity projection. The images from CTA from examination apparatus and reconstruction technique were all larger than the actual measurement.

Piroxicam, Mitoxantrone, and Hypofractionated Radiation Therapy with Volumetric Modulated Arc Therapy for Treating Urinary Transitional Cell Carcinoma in a Dog: A Case Report

  • Hwang, Tae-Sung;An, Soyon;Choi, Moon-Young;Huh, Chan;Song, Joong-Hyun;Jung, Dong-In;Lee, Hee Chun
    • Journal of Veterinary Clinics
    • /
    • v.39 no.1
    • /
    • pp.16-22
    • /
    • 2022
  • A 12-year-old spayed female beagle dog was presented with pollakiuria and stranguria. Abdominal ultrasonography identified irregular a marginated, hyperechoic mass in the urethra and trigon area of the bladder. Computed tomography (CT) revealed a heterogeneous mass in the trigone area leading to a urethra. There was no evidence of regional or distant metastasis. Cytologic analysis suspected transitional cell carcinoma (TCC). The patient was treated with piroxicam, mitoxantrone, and once weekly fractionated radiation therapy (RT) with volumetric modulated arc therapy (VMAT). A follow-up CT scan at 6 months after RT revealed a reduction in tumor size. At 17 months after the start of RT, the patient became severely anorectic and lethargic. Ultrasound examination revealed a hyperechoic mass in the apex area of bladder while the trigone area of the bladder and urethra appeared normal. Multiple hypoechoic nodules of various sizes were found in the liver and spleen. The patient was humanely euthanized at the request of the owner. A combination of piroxicam, mitoxantrone, and hypofractionated RT with VMAT protocol was well tolerated. This case described tumor response and survival time of a canine TCC treated with piroxicam, mitoxantrone, and once weekly palliative RT using computer-assisted planning and VMAT.

An Assessment of the Utility of Respiratory Synchronized Systems in the PET/CT Examination (PET-CT 검사 시 호흡 동조 시스템들의 유용성 평가)

  • Seong, Yong-Jun;Yoon, Seok-Hwan;Hyun, Jun-Ho;Lee, Hong-jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.34-38
    • /
    • 2017
  • Purpose During PET/CT examinations, the movements of internal organs caused by respiration are captured in images during multiple breathing cycles, resulting in the increases in tumor size and effects on SUV. Respiratory synchronized systems were used to evaluate tumor sizes and SUV changes. Materials and Methods Biograph mCT 64 was used for the equipment, and RPM and Anzai systems were used for the respiratory synchronized systems. We used point source and micro-phantom for an experimentation. We were performed on 12 patients who had solid tumors discovered at the base of the lung or at the top of the liver from August through September 2016. The PET images of the exhalation-to-breathing state and the CT images of the post-exhalation suspension state were gained to evaluate changes in radioactivity concentration (KBq/mL), SUVmax, cylinder diameter (mm), and tumor diameter (cm) under the conventional Static, RPM, and Anzai methods. Results The result of measuring the radioactivity concentration of the point source was RPM 94% and Anzai 91% against Static, respectively. In the two cylinders of different radioactivity in the micro-phantom, the SUVmax increased to RPM 61% and 78%, and Anzai 58% and 77% against Static, whereas the cylinder diameters decreased by RPM -26% and -28%, and Anzai -28% and -26%, each respectively. Among the patients, the SUVmax increased from a minimum of RPM 8.2% to a maximum of 94.4% against Static, and from a minimum of Anzai 7.6% to a maximum of 68.3%, respectively. As for the tumor diameters, a minimum of RPM -7.6% to a maximum of -28.9% were achieved, while the Anzai fell by a minimum of -9.6% to a maximum of -27.7%, respectively. There was no significant difference discovered in the phantom study between the RPM and Anzai, yet there was a meaningful difference in the patients' tumors (P<0.05). Conclusion The respiratory synchronized systems of RPM and Anzai yielded no significant difference in the phantom study in which the respiration was executed at regular intervals. However, it was discovered that the patients had a meaningful difference for the irregular respiratory cycle and inter-system differences. Still, the respiratory synchronized systems would be useful for the accurate diagnosis and SUV measurement as the tumor decreased in size against the existing Static and the SUV increased.

  • PDF

Clinical Outcomes After Arthroscopic Double-Row Rotator Cuff Repair and Evaluation of Cuff Integrity by CT Arthrography (관절경적 2열 고정 회전근개 복원술 후의 임상 결과 및 CT 관절조영술을 이용한 건의 치유 평가)

  • Jo, Chris H.;Kim, Je-Kyoon;Yoon, Kang-Sup;Lee, Ji-Ho;Kang, Seung-Baek;Lee, Jae-Hyup;Han, Hyuk-Soo;Rhee, Seung-Whan
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.199-206
    • /
    • 2009
  • Purpose: Our goal for this study was to prospectively evaluate the functional & structural outcomes, by means of CT arthroscopy, of arthroscopic double-row fixation for treating rotator cuff tear. We also attempted to determine the variants that affect the functional & structural outcomes. Materials and Methods: Twenty seven consecutive patients underwent arthroscopic rotator cuff repair with double-row fixation. The average age at the time of the operation was fifty six years. The preoperative and postoperative examinations consisted of determining the Constant score, the score for the visual analogue scale for pain, the UCLA score, the American Shoulder and Elbow Surgeons (ASES) score, as well as a full physical examination of the shoulder. Preoperative MR arthrography was used to evaluate the integrity and atrophy of the rotator cuff. We measured the intraoperative tear size in the sagittal and coronal planes. Postoperative CT arthrography was used at one year postoperatively to evaluate the integrity and atrophy of the repaired tendons and muscles. Results: Preoperative MR arthrography revealed an average 29.22 mm tear size in the sagittal plane and an average 22.72 mm tear size in the coronal plane. Twelve cases of supraspinatus muscle atrophy and two cases of infraspinatus atrophy were observed on the preoperative MR arthrography. The average clinical outcome scores all significantly improved at the time of follow-up. At a mean of one year postoperatively, CT arthrography revealed 48.1% of the shoulders had healed, 11.1% showed incomplete healing and 40.7% showed retear of the repaired tendon. Conclusion: Arthroscopic double-row repair can result in improved clinical outcomes and good patient satisfaction. However, the problems about how to enhance healing of the repaired tendon still remain.

Leiomyosarcoma of the Mandible : Report of a Case (하악골에 발생한 평활근육종)

  • Lee Jean;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.549-559
    • /
    • 1999
  • Leiomyosarcoma is extremely rare in the oral cavity and especially in the mandible. At first. the case of this report was diagnosed as odontogenic fibroma but after approximately 3.5 years. it was diagnosed as leiomyosarcoma. Conventional radiograph of the first time showed an ill-defined radiolucent lesion in the mandible. After local recurrence. CT images showed a large irregular soft tissue mass with some necrotic areas. These findings were not specific for leiomyosarcoma, but they suggested that this lesion was a recurrent soft tissue sarcoma. Histopathological examinations using H & E staining, immunohistochemical staining and Masson's trichrome staining confirmed this case as leiomyosarcoma. Deciding its malignancy or benignancy, defining the tumor extent and its relationship to the surrounding anatomic structures, and evaluating the distant metastasis are more important roles of radiographic examination than finding out the name of disease.

  • PDF

Painless Jaundice Caused by Clonorchis sinensis Infection: A Case Report

  • Hao, Yuhua;Bao, Wanguo;Jin, Meishan;Li, Yuxiang;Wang, Feng
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.3
    • /
    • pp.323-327
    • /
    • 2016
  • A man with only yellowing of the skin and eye sclera was diagnosed with clonorchiasis, which rarely manifested jaundice as the initial symptom. However, because of a lack of evidence for a diagnostic gold standard, the time until definitive diagnosis was more than a week. The diagnostic process relied on inquiring about the patient's history, including the place of residence, dietary habits, and symptoms, as well as on serological findings, an imaging examination, and pathological findings. MRCP and CT results showed mild dilatation of intrahepatic ducts and increased periductal echogenicity. The eggs were ultimately found in stool by water sedimentation method after the negative report through direct smear. DNA sequencing of PCR production of the eggs demonstrated 98-100% homology with ITS2 of Clonorchis sinensis. After anti-parasite medical treatment, the patient's symptoms were gradually relieved. Throughout the diagnostic procedure, besides routine examinations, the sedimentation method or concentration method could be used as a sensitive way for both light and heavy C. sinensis infection in the definite diagnosis.

Peroneal Tendon Dislocation associated with Calcaneal Fracture (Six Cases Report) (종골 골절과 동반된 비골건 탈구(6예보고))

  • Cha, Seung-Do;Kim, Hyung-Soo;Jung, Soo-Tae;Park, Jae-Hyung;Kim, Joo-Hak;Yeom, Joo-Sang;Lee, Chang-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.2
    • /
    • pp.210-215
    • /
    • 2008
  • Peroneal tendon dislocation in association with calcaneal fracture is not common and difficult to diagnose and is often overlooked. It can result in peroneal tendon tear and tenosynovitis which in turn lead to ankle pain and dysfunction. Early detection with through physical examination and CT scan is important to reduce the subsequent tendon dysfunction. We experienced 6 cases of peroneal tendon dislocation associated with calcaneal fracture, and treated 3 of them at the time of fracture operation and treated the other 3 after calcaneal fracture surgery due to sustained pain. We report the results with a review of the literature.

  • PDF