• Title/Summary/Keyword: CT 촬영

Search Result 1,584, Processing Time 0.035 seconds

Radiography and Computed Tomography in Four Dogs with Lung Lobe Torsion (흉부 방사선 촬영과 컴퓨터단층촬영을 이용한 폐염전의 진단 4례)

  • Lee, Ki-Ja;Choi, Sung-Jin;Kim, Young-Hwan;Jeong, In-Seong;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.30 no.5
    • /
    • pp.390-393
    • /
    • 2013
  • This case study describes the imaging features of radiography and computed tomography (CT) in four small breed dogs with lung lobe torsion. The medical records, thoracic radiographs and CT images of four dogs with confirmed lung lobe torsion were retrospectively reviewed. Pleural effusion and increased lobar opacity/density were seen on all CT and thoracic radiography in all four dogs. CT revealed narrowed/collapsed bronchus in all four dogs, while this was only appreciated on one thoracic radiography. The vesicular emphysema pattern was seen on four CT but only on three radiographic examinations. The specific findings of lung lobe torsion were vesicular emphysema and a narrowed/collapsed bronchus. These findings were more easily recognized on CT than with thoracic radiographs.

Development of a Micro-CT System for Small Animal Imaging (소 동물 촬영을 위한 Micro-CT의 개발)

  • Sang Chul Lee;Ho Kyung Kim;In Kon Chun;Myung Hye Cho;Min Hyoung Cho;Soo Yeol Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.97-102
    • /
    • 2004
  • We developed an x-ray cone-beam micro computed tomography (micro-CT) system for small-animal imaging. The micro-CT system consists of a 2-D flat-panel x-ray detector with a field-of-view (FOV) of 120${\times}$120 mm2, a micro-focus x-ray source, a scan controller and a parallel image reconstruction system. Imaging performances of the micro-CT system have been evaluated in terms of contrast and spatial resolution. The minimum resolvable contrast has been found to be less than 36 CT numbers at the dose of 95 mGy and the spatial resolution about 14 lp/mm. As small animal imaging results, we present high resolution 3-D images of rat organs including a femur, a heart and vessels. We expected that the developed micro-CT system can be greatly used in biomedical studies using small animals.

Usefulness of Application of Tube Voltage Changes to Reduce Patient Dose during Abdominal CT Follow up (반복적인 복부 컴퓨터단층촬영 시행 시 환자선량 감소를 위한 관전압 변화 적용의 유용성)

  • Yoon, Joon;Kim, HyeonJu
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.293-299
    • /
    • 2021
  • In order to reduce the irresistible radiation exposure of patients who perform periodic examinations using a CT among various scan parameters a method to reduce patient dose was investigated through changes in the tube voltage close to X-ray penetrating power. As a result of the experiment 100 kVp was applied instead of 120 kVp which is commonly used in clinical practice and CTDI decreased by about 41% during scan. In addition the degree of change in image quality was measured as 1046.1±3.7 HU for CT value and 71.4±7.9 for Pixel value and statistical analysis showed no significant difference (0.05

The efficacy of computerized tomographic scan for chest trauma (흉부외상 환자에 대한 전산화 단층촬영의 효용성)

  • Roh, Hwan-Kyu;Choi, Ho;Kim, Young-Jin;Kim, Jung-Tae;Soh, Dong-Moon;Ryu, Han-Young;Lee, Cheol-Joo
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.298-303
    • /
    • 1998
  • Computerized tomography(CT) is an effective technique in the initial evaluation of the abdomen and head following blunt trauma. To evaluate the efficacy of CT of the thorax, a retrospective study comparing early thoracic CT scanning with initial chest roentgenogram (CXR) was carried out on 134 patients with blunt trauma on the chest. Among 134 patients, 45 patients had normal initial chest roentgenogram and 24 patients showed normal CT findings. Sensitivities of diagnosing pneumothorax and pleural effusion by CXR were low (46.2 and 62.9% respectively), whereas 71.4%(45/63) of patients had thoracostomy only by CXR. Although sometimes abused, CT of the thorax is effective in the initial diagnosis.

  • PDF

Volumetric Estimation of the Prostate Gland using Computed Tomography in Normal Beagle Dogs (정상 비글견에서 컴퓨터단층촬영술을 이용한 전립선의 부피 평가)

  • Choi, Ji-Young;Choi, Soo-Young;Lee, Ki-Ja;Jeong, Woo-Chang;Han, Woo-Sok;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.31 no.3
    • /
    • pp.175-179
    • /
    • 2014
  • The purpose of this study was to determine and compare prostate size using ultrasound and computed tomography (CT). The prostate gland was evaluated in eight normal Beagle dogs. Length, depth, and width of the prostate gland were measured by ultrasound and volume of the prostate was obtained from the two ellipsoid formula (US1, US2). Height, length, width, area, and volume of the prostate gland were measured by CT. Ratios of prostatic height, length, and width to the sixth lumbar vertebral body length were calculated. There was no significant difference between the US1 and US2 method, and between US2 and CT method, respectively. The prostatic volume calculated by US1 method was significantly lower than those with CT (p=0.029). The Upper limits of ratios of prostate length, height, and width to the length of the sixth lumbar vertebra were 1.3, 1.1, and 1.7, respectively. Among these prostate dimensions, prostate length and height could be a useful index in estimating prostate size regardless of body weight.

Optimization of Exposure Parameters in Brain Computed Tomography (두부 전산화단층촬영에서 노출 파라미터의 최적화)

  • Ko, Seong-Jin;Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.355-362
    • /
    • 2010
  • This study determines a range of CT parameter values in Brain CT which are minimizing patient absorption dose without compromising the image quality and optimal exposure condition. We measured dose and image noise using conventional CT parameters in Brain CT. In additon, we evaluated dose, SNR and PSNR of head phantom images while changing kVp and rotation time. In this study, effectiveness of dose that was achieved from dose reproducible experiments in conventional head CT condition is determined by changing kVp and rotation time. Dose and PSNR is related to low dose-high resolution condition. In conclusion, we suggest that using proposed conditions is effective for imaging to compare with conditions proposed by the manufacturer.

Case Study of Quality Assurance for MDCT Image Quality Evaluation Using AAPM CT Performance Phantom (AAPM CT 성능 평가용 팬텀을 이용한 전산화단층촬영의 영상 평가를 위한 정도관리 사례 연구)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.7
    • /
    • pp.114-123
    • /
    • 2007
  • The increasing use of computed tomography (CT) as a diagnostic tool creates the need from and efficient means of evaluating the performance of the CT scanner now in use. Accordingly, acceptance testing and quality assurance of CT is of great importance. The aim of this study is to analyze of AAPM CT performance phantom in the CT accreditation program. The modular phantom offers the CT system with which to measure eight performance parameters. The parameters are listed of CT attenuation coefficient of water, noise, uniformity, spatial resolution, contrast resolution, slice thickness (5 and 10 mm), artifacts and alignment. The phantom evaluation was done by two radiologists. The acceptance testing protocol described here in demonstrates the successful of the guidelines for the quality assurance using AAPM CT performance phantom. We need to be upgraded for the CT image quality and make the standard reference of the quality assurance in the CT.

Assessment of DRL for Computed Tomography in Local Hospital (지역병원에서의 전산화단층촬영 검사에 대한 DRL 평가)

  • Choi, Seok-Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.619-625
    • /
    • 2022
  • In the field of imaging medicine, computed tomography is one of the most common test methods and one of the most frequently used test methods in hospitals. However, it is accompanied by a very high radiation exposure compared to other test methods. In order to reduce exposure, CT scans should be performed only when absolutely necessary, and even if the tests are performed because they are absolutely necessary, a protocol that serves the purpose of the test and allows the test to be performed in a small dose should be used. In this study, we wanted to learn about the most up-to-date radiation dose usage information used by the region's leading general hospitals and develop a diagnostic reference level (DRL). In the experimental results, the Head CT and Abdomen CT tests showed that DLP was higher than the NRPB (U.K) and Korean DRL. The DLP values used by Chest CT were low for all 3 types of CT devices. The hospital found that efforts to reduce exposure should be made during CT examinations, and in particular, Head CT and Abdomen CT determined that efforts to reduce exposure were necessary.

The Effect of a Chest CT Scan on the Treatment and Diagnosis of Major Blunt Chest Trauma (흉부 둔상환자에서 흉부전산화단층촬영이 진단과 치료에 미치는 영향)

  • Park, Il-Hwan;Oh, Joong-Hwan;Lee, Chong-Kook
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.226-232
    • /
    • 2009
  • Background: Blunt chest trauma accounts for 90% of all chest traumas in Europe and the United States and this causes 20% of all trauma-related deaths. The major cause of morbidity and mortality after blunt chest trauma is undetected injuries. For this reason, chest computerized tomography has gained popularity for the evaluation of trauma, but it is expensive and it exposes patients to radiation. This study identified the clinical features associated with the diagnosic information obtained on a CT chest scan, as compared with a standard chest X-ray, for patients who sustained blunt trauma to the chest. This study also evaluated the role of a routine computed tomographic (CT) scan for these patients. The patients who had chest computed tomography done after the initial chest x-ray were analyzed separately for the presence of occult injuries. Material and Method: We studied 100 consecutive patients from November 2006 to July 2007: 74 patients after motor vehicle crashes and 26 patients after a fall from a height >2m. Simultaneous with the initial clinical evaluation, an anteroposterior chest radiograph and a helical chest CT scan were obtained for all the patients. The data extracted from the medical record included the vital signs, the interventions and the type and severity of injury (RTS). Result: Among the 100 cases, 79 patients showed at least more than one pathologic sign on their chest radiograph, and 21 patients had a normal chest radiograph. For 17 of the patients who had a normal chest X ray, the CT scan showed multiple injuries, which were pneumothorax, hemothorax, lung contusion, sternal fracture etc. This represents that a CT scan is statistically superior to a chest radiograph to diagnose the pathologic signs. But on the other hand, as for treatment, only 31 patients were diagnosed by CT scan and they were treated with chest tube insertion ect. 42 patients needed ony conservative management without invasive thoracosurgical treatment such as chest tube insertion or open thoracotomy. 27 patients were treated based on the diagnosis made by the chest radiograph and physical examination. Conclusion: Chest computerized tomography was significantly more effective than routine chest X-ray for detecting lung contusion, pneumothorax and mediastinal hematoma, as well as fractured ribs, scapula and, sternum. Although the occult findings increased, the number of patients who needed treatment was small. Therefore, we suggest making selective use of a CT scan to avoid its overuse in ERs.

Efficacy of Positron Emission Tomography in Diagnosing Pulmonary Tumor and Staging of Lung Cancer : Comparing to Computed Tomography (폐종양과 폐암의 병기결정에 대한 양전자단층촬영(PET)의 유용성 -전산화단층촬영 (CT)과의 비교-)

  • 김오곤;조중행;성숙환
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2003
  • Diagnosing and determining the stage of lung cancer by means of positron emission tomography (PET) ha.. been proven valuable because of the limitations of diagnosis by computed tomography (CT). We compared the efficacy of PET with that of CT in diagnosing pulmonary tumor and staging of lung cancer Material and Method: We performed F-18 FDG PET to determine the malignancy and the staging on patients who have been suspicious or were diagnosed as lung cancer by chest X-ray and CT. The findings of PET and of CT of 41 patients (male, 29: female, 12: mean age, 59) were compared with pathologic findings obtained from a mediastinoscopy and thoracotomy. Result: Out of 41 patients, 35 patients had malignant lesions (squamous cell carcinonla 19 cases, adenocarcinoma 14 cases, adenosquamous cell carcinoma 2 cases) and 6 patients had benign lesions. Diagnosing of lung cancer, the sensitivity, specificity and accuracy of CT and PET were the same for two method and the numbers were 100%, 50%, and 92.7% respectively. Eighteen LN groups out of 108 mediastinal LN groups who recieved histologic examination proved to be malignant. Pathologic lymph node (LN) stage was N0-Nl 31 cases, N2 8 cases, N3 2 cases. The correct identification of the nodal staging with CT, PET scans were 31 cases (75.6%), 28 cases (68.3%) respectively. The LN group was underestimated in each 6 cases of CT and PET. In 4 cases of CT and 7 cases of PET, they were overestimated in compare to histologic diagnosis. In the detection of mediastinal LN groups invasion, the sensitivity, specificity and accuracy of CT were 39.8 %, 93.3 %, and 84.3 % respectively. For PET, they were 61.1 %, 90.0 %, and 85.2 %. When two methods considered together (CT+PET), they were increased to 77.8 %, 93.3 %, and 90.7 % respectively. Conclusion: PET appears to be similar to CT in the diagnosis and the nodal taging of pulmonary tumor. Two tests may stage patients with lung cancer more accurately than CT alone.