• Title/Summary/Keyword: CT 잡음

Search Result 123, Processing Time 0.03 seconds

A Study on Characteristic of Image Quality according to CT Table Height in Computed Tomography (컴퓨터단층촬영 검사 시 테이블 높이에 따른 화질 특성에 관한 연구)

  • Ki-Won Kim;Jung-Whan Min;Sang-Sun Lee;Young-Bong Lee;Ki-Jong Lee;Han-Sol Park;Joo-Young Oh
    • Journal of radiological science and technology
    • /
    • v.46 no.4
    • /
    • pp.295-301
    • /
    • 2023
  • In addition to protocol adjustments during CT examinations, the height of the CT table can also affect image quality. Therefore, this study aimed to investigate the change in image quality depending on the height of the table in brain CT, which accounts for a large proportion of CT examinations, by measuring signal to contrast to noise ratio (CNR) and noise power spectrum (NPS) using the head phantom and evaluating them. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. The CNR result showed the highest value at 965 mm, which is the height adjacent to the center of the head phantom. NPS showed the lowest NPS at 915 mm, the center of the head phantom in the low frequency region. From these results, it can be seen that the height of the table in CT examination is closely related to the image quality, and it can be seen the characteristics of image quality according to CT table through quantitative evaluation methods such as CNR and NPS.

A Study on the Dose Reduction Method for Temporal Bone HRCT Scan (관자뼈 HRCT 스캔 시 선량감소 방법에 관한 연구)

  • Joon Yoon;Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1041-1047
    • /
    • 2023
  • Temporal bone CT, which is a high-resolution CT, uses a high tube voltage and a thin section thickness, so the scan dose is higher than that of adjacent areas. Accordingly, we applied changes to the reconstruction algorithm among the test conditions to find an algorithm with excellent sensitivity to lesions while reducing the test dose, and investigated its significance and the possibility of providing basic clinical data. As a result, when the tube voltage was lowered to 100 kVp and applied, the dose was reduced by about 35.6%, and when the definition algorithm was applied to the raw data acquired at 100 kVp, the SNR and CNR were excellent, and a statistically significant difference was shown when compared to other algorithms(p<0.05). And as a result of comparing structural similarity, the SSIM index was analyzed as 0.776, 0.813, and 0.741 for each ROI. Therefore, we believe that applying algorithm changes to temporal bone CT scans can partially reduce the dose generated from CT scans and are very meaningful in terms of basic clinical data.

Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols (반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험)

  • Ha, Seongmin;Jung, Sunghee;Chang, Hyuk-Jae;Park, Eun-Ah;Shim, Hackjoon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, we investigated the effects of an iterative reconstruction algorithm and an automatic exposure control (AEC) technique on image quality and radiation dose through phantom experiments with coronary computed tomography (CT) angiography protocols. We scanned the AAPM CT performance phantom using 320 multi-detector-row CT. At the tube voltages of 80, 100, and 120 kVp, the scanning was repeated with two settings of the AEC technique, i.e., with the target standard deviations (SD) values of 33 (the higher tube current) and 44 (the lower tube current). The scanned projection data were reconstructed also in two ways, with the filtered back projection (FBP) and with the iterative reconstruction technique (AIDR-3D). The image quality was evaluated quantitatively with the noise standard deviation, modulation transfer function, and the contrast to noise ratio (CNR). More specifically, we analyzed the influences of selection of a tube voltage and a reconstruction algorithm on tube current modulation and consequently on radiation dose. Reduction of image noise by the iterative reconstruction algorithm compared with the FBP was revealed eminently, especially with the lower tube current protocols, i.e., it was decreased by 46% and 38%, when the AEC was established with the lower dose (the target SD=44) and the higher dose (the target SD=33), respectively. As a side effect of iterative reconstruction, the spatial resolution was decreased by a degree that could not mar the remarkable gains in terms of noise reduction. Consequently, if coronary CT angiogprahy is scanned and reconstructed using both the automatic exposure control and iterative reconstruction techniques, it is anticipated that, in comparison with a conventional acquisition method, image noise can be reduced significantly with slight decrease in spatial resolution, implying clinical advantages of radiation dose reduction, still being faithful to the ALARA principle.

Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels (필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성)

  • Hye Ji;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho;Joon Young Ohm
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.669-679
    • /
    • 2022
  • Purpose To evaluate the feasibility of pediatric low-dose facial CT reconstructed with filtered back projection (FBP) using adequate kernels. Materials and Methods We retrospectively reviewed the clinical and imaging data of children aged < 10 years who underwent facial CT at our emergency department. The patients were divided into two groups: low-dose CT (LDCT; Group A, n = 73) with a fixed 80-kVp tube potential and automatic tube current modulation (ATCM) and standard-dose CT (SDCT; Group B, n = 40) with a fixed 120-kVp tube potential and ATCM. All images were reconstructed with FBP using bone and soft tissue kernels in Group A and only bone kernel in Group B. The groups were compared in terms of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two radiologists subjectively scored the overall image quality of bony and soft tissue structures. The CT dose index volume and dose-length product were recorded. Results Image noise was higher in Group A than in Group B in bone kernel images (p < 0.001). Group A using a soft tissue kernel showed the highest SNR and CNR for all soft tissue structures (all p < 0.001). In the qualitative analysis of bony structures, Group A scores were found to be similar to or higher than Group B scores on comparing bone kernel images. In the qualitative analysis of soft tissue structures, there was no significant difference between Group A using a soft tissue kernel and Group B using a bone kernel with a soft tissue window setting (p > 0.05). Group A showed a 76.9% reduction in radiation dose compared to Group B (3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy; p < 0.001). Conclusion The addition of a soft tissue kernel image to conventional CT reconstructed with FBP enables the use of pediatric low-dose facial CT protocol while maintaining image quality.

Improved Image Quality and Radiation Dose Reduction in Liver Dynamic CT Scan with the Protocol Change (Liver CT 검사에서 프로토콜 변화에 따른 선량 감소와 영상의 질 개선에 관한 연구)

  • Cho, Yu-Jin;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.107-114
    • /
    • 2015
  • The purpose is reducing radiation dose while maintaining of image quality in liver dynamic CT(LDCT) scan, by protocols generally used and the tube voltage set at a low level protocol compared to the radiation dose and image quality. The target is body mass index, 18.5~24 patients out of 40 patients who underwent the ACT(abdominal CT). Group A(tube voltage : 120kVp, SAFIRE strength 1) of 20 people among 40 people, to apply the general abdominal CT scan protocol, group B(tube voltage : 100kVp, apply SAFIRE strength 0~5) was 20 people, set a lower tube voltage. Image quality evaluation was setting a region of interest(ROI) in the liver parenchyma, aorta, superior mesenteric artery (SMA), celiac trunk, visceral fat of arterial phase. In the ROI were compared by measuring the noise, signal to noise ratio(SNR), contrast to noise ratio(CNR), CT number. In addition, qualitative assessments to evaluate two people in the rich professional experience in Radiology by 0-3 points. We compared the total radiation dose, dose length product(DLP) and effective dose, volume computed tomography dose index(CTDIvol). The higher SAFIRE in the tube voltage 100 kVp, noise is reduced, CT number was increased. Thus, SNR and CNR was increased higher the SAFIRE step. Compared with the tube voltage 120kVp, noise, SNR, CNR was most similar in SAFIRE strength 2 and 3. Qualitative assessment SAFIRE strength 2 is the most common SAFIRE strength 2 the most common qualitative assessment, if the tube voltage of 100kVp when the quality of the images better evaluated was SAFIRE strength 1. Dose was reduced from 21.69%, in 100kVp than 120kVp. In the case of a relatively high BMI is not LDCT scan, When it is shipped from the factory tube voltage is set higher, unnecessary radiation exposure when considering the reality that is concerned, when according to the results of this study, set a lower tube voltage and adjust the SAFIRE strength to 1 or 2, the radiation without compromising image quality amount also is thought to be able to be reduced.

Salt and Pepper Noise Removal Algorithm based on Euclidean Distance Weight (유클리드 거리 가중치를 기반한 Salt and Pepper 잡음 제거 알고리즘)

  • Chung, Young-Su;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.11
    • /
    • pp.1637-1643
    • /
    • 2022
  • In recent years, the demand for image-processing technology in digital marketing has increased due to the expansion and diversification of the digital market, such as video, security, and machine intelligence. Noise-processing is essential for image-correction and reconstruction, especially in the case of sensitive noises, such as in CT, MRI, X-ray, and scanners. The two main salt and pepper noises have been actively studied, but the details and edges are still unsatisfactory and tend to blur when there is a lot of noise. Therefore, this paper proposes an algorithm that applies a weight-based Euclidean distance equation to the partial mask and uses only the non-noisy pixels that are the most similar to the original as effective pixels. The proposed algorithm determines the type of filter based on the state of the internal pixels of the designed partial mask and the degree of mask deterioration, which results in superior noise cancellation even in highly damaged environments.

A Study on Applied to Optimal Diagnostic Device in Portal Vein Visualization: Focused on MRI and CT (간문맥 묘출을 위한 최적의 영상진단 장치에 관한 연구: MRI, CT 중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.217-225
    • /
    • 2019
  • The purpose of this study was to quantitate signal to noise ratio and contrast to noise ratio of the portal vein using CT and 3.0T MRI and to investigate the optimal imaging device. Twenty patients who inspective CT and 3.0T MRI between February 2018 and April 2018 were randomly assigned to receive data from the picture archiving communication system. The SNR and CNR values were evaluated by measuring the mean and standard deviation of the region of interest of the four regions of the portal vein (the main portal vein, the right vein, the left vein, and the middle vein). The results showed that SNR was 9.180.72 in the right context, 9.410.84 in the left context, 9.540.59 in the middle context, 9.550.75 in the order context, and 22.292.03 in the right context and 25.893 in the 3.0T MRI. 19, median context: 24.392.87, and order Mac: 26.642.30 (p<0.05). CNR was 3.790.68 in the CT context, 3.740.65 in the left context, 3.710.39 in the middle context, 3.790.68 in the order context, 9.490.65 in the right context, and 11.0001.90 in the 3.0T MRI, Intermediate context: 12.701.75, order Mac: 10.010.98, 3.0T MRI was higher than CT (p<0.05). In conclusion, SNR and CNR values were higher in the 3.0T MRI than CT in the 4 portal regions. Therefore, 3.0T MRI using non-ionizing radiation was the most superior imaging equipment than CT.

Performance Comparison of Optical CT and legacy CT in aspect of Protective relaying (보호계전 측면에서의 광 CT와 기존 CT간의 성능 비교)

  • Park, Byung-Seok;Ahn, Seung-Joon;Jang, Moon-Jong;Woo, Hee-Gon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1404-1406
    • /
    • 1999
  • 전력계통에서 전류를 측정하는 변류기는 주요 전력 설비와 연계되어 보호 및 감시에 있어 중요한 역할을 수행한다. 그러나 기존방식의 전류 변성기는 자기포화에 의한 파형 왜곡과 써지나 잡음 등의 전기적 장치가 갖는 구조적 문제점을 가지고 있다. 이러한 문제점을 개선하기 위한 방법으로 전류에 의해 형성된 자계에 의해 광신호의 편광(polarization) 회전을 발생시키는 Faraday 효과를 가지는 광센서를 이용하여 보호계전 분야에 적용 가능한 전류계측기술을 개발하였다. 본 논문에서는 기존 전류변성기의 계통 보호에서 발생하는 문제점을 PSCAD/EMTDC 시스템을 이용하여 시뮬레이션 하였으며, 아울러 동일 조건에서 광 CT의 동작 특성을 산출하여 기존 전류변성기와 비교 분석하였다. 분석 결과들로부터 광 CT는 기존 전류변성기가 자기포화되는 상황에서도 정확한 1차 전류의 측정이 가능함을 보였다.

  • PDF

Artifact Reduction in Sparse-view Computed Tomography Image using Residual Learning Combined with Wavelet Transformation (Wavelet 변환과 결합한 잔차 학습을 이용한 희박뷰 전산화단층영상의 인공물 감소)

  • Lee, Seungwan
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.295-302
    • /
    • 2022
  • Sparse-view computed tomography (CT) imaging technique is able to reduce radiation dose, ensure the uniformity of image characteristics among projections and suppress noise. However, the reconstructed images obtained by the sparse-view CT imaging technique suffer from severe artifacts, resulting in the distortion of image quality and internal structures. In this study, we proposed a convolutional neural network (CNN) with wavelet transformation and residual learning for reducing artifacts in sparse-view CT image, and the performance of the trained model was quantitatively analyzed. The CNN consisted of wavelet transformation, convolutional and inverse wavelet transformation layers, and input and output images were configured as sparse-view CT images and residual images, respectively. For training the CNN, the loss function was calculated by using mean squared error (MSE), and the Adam function was used as an optimizer. Result images were obtained by subtracting the residual images, which were predicted by the trained model, from sparse-view CT images. The quantitative accuracy of the result images were measured in terms of peak signal-to-noise ratio (PSNR) and structural similarity (SSIM). The results showed that the trained model is able to improve the spatial resolution of the result images as well as reduce artifacts in sparse-view CT images effectively. Also, the trained model increased the PSNR and SSIM by 8.18% and 19.71% in comparison to the imaging model trained without wavelet transformation and residual learning, respectively. Therefore, the imaging model proposed in this study can restore the image quality of sparse-view CT image by reducing artifacts, improving spatial resolution and quantitative accuracy.

Evaluation of Dose and Image Quality of Lens according to Baseline during Brain CT Scan (두부 전산화단층촬영 시 기준선에 따른 수정체 선량과 화질 평가)

  • Kim, Kyu-Hyung;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.699-704
    • /
    • 2019
  • It is important to minimize the exposure dose during an examination and obtain good quality images at the same time. This study compared the beam harding effect according to the baseline superior orbito meatal line(SOML), orbito meatal line(OML), inferior orbito metal line(OML) and measured the exposure dose of the lens, especially in brain CT examinations, which generally apply to head diease patients. The beam harding effect assessment of each image along the baseline was performed quantitatively using the Image J program, and the exposure dose of the lens was detected by OSLDs and compared. As a result, As a result, when the SOML was used as the reference line, the dose of the lens was decreased by 85.08% at 80 kV and by 79.7% at 80 kV, compared to when IOML was used as the baseline. If the gantry angle at brain CT was parallel scan to SOML, there were no significant differences in the exposure to the lens and between the OML and IOML. Therefore, this study has shown that it is efficient to have a parallel scan on SOML as a protocol during Brain CT examinations.