• Title/Summary/Keyword: CT (computed tomography)

Search Result 2,651, Processing Time 0.031 seconds

The Analysis of Post Operative Treatment of Malignant Melanoma Using High Dose Interferon-${\alpha}2b$ Immunotherapy: Preliminary Report (악성흑색종 환자군에서 수술적 치료 후 시행한 고용량 인터페론-${\alpha}2b$ 면역요법에 의한 보조적 치료 결과 분석: 예비보고)

  • Chung, So Hak;Jo, Hyun Ik
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.18 no.2
    • /
    • pp.78-82
    • /
    • 2012
  • Purpose: Interferon-${\alpha}2b$ using immunotherapy of malignant melanoma is known to increase the microscopic enemies that remain after surgical resection of the tumor to prevent recurrence, disease-free survival and overall survival. Authors in patients with malignant melanoma after surgical resection and high-dose interferon-${\alpha}$ immunotherapy treated group of disease-free survival and overall survival compared with the results of the treatment of immune therapy to a preliminary report. Materials and Methods: From February 2010 to October 2012 at our institution between being diagnosed with malignant melanoma after surgical immunotherapy treated patients were analyzed. Patients was evaluated using the stage AJCC stage IIA 3 cases, IIB 1 cases, IV 1 were as follows. Follow-up period of at least 7 months, and a maximum of 32 months. As maintenance therapy after the first induction therapy group underwent immunotherapy interferon-${\alpha}$ of body-surface area per 200,000 IU five times in a week for 4 weeks sedentary and body surface area a total of 48 weeks per week to 100,000 IU three times subcutaneously. These patients for local recurrence and metastases, and distant metastasis were investigated disease-free survival was investigated. Results: Interferon-evaluation through follow-up chest computed tomography (CT) and positron emission computed tomography (PET CT) in patients who underwent the ${\alpha}$ immunotherapy results above both local recurrence and metastases without evidence of distant metastases. Conclusion: The high-dose ${\alpha}2b$ immunotherapy performed in patients to prevent the local recurrence of the tumor and metastasis to the current or future ultimate survival and disease-free survival improvement achieved is additional study and follow-up will be needed.

Three dimensional analysis of tooth movement using different sizes of NiTi wire on NiTi scissors-bite corrector (NiTi scissors-bite corrector의 와이어 굵기에 따른 3차원적 치아 이동 양상)

  • Jeon, Hyun-Ju;Park, Sun-Hyung;Jung, Sang-Hyuk;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.39 no.1
    • /
    • pp.43-53
    • /
    • 2009
  • Objective: The purpose of this study was to compare the difference in three dimensional tooth movement using three different wire sizes($0.018{\times}0.025-in,\;0.016{\times}0.022-in$ 0.016-in) on a NiTi scissors-bite corrector. Methods: Computed tomography(CT) images of the experimental model before and after tooth movement were taken and reconstructed into three dimensional models for superimposition. The direction and the amount of tooth movement were measured and analyzed statistically. Results: The lingual and intrusive movements of the crown of the maxillary second molar were increased as the size of the NiTi wire increased. The roots of the maxillary second metals moved buccally except for the 0.016-in group. The intrusive movement of the roots of the maxillary second molars was increased as the size of the NiTi wire increased. Due to the use of orthodontic mini-implants, anchorage loss was under 0.2 mm on average. Conclusions: The $0.018{\times}0.025-in$ NiTi wire was most effective in lingual and intrusive movement of the maxillary second molar which was in scissors-bite position. Indirect skeletal anchorage with a single orthodontic mini-implant was rigid enough to prevent anchorage loss.

Clinical Characteristics of Aspergilloma (국균종의 임상적 고찰)

  • Kim, Ki-Up;Gil, Hyo-Wook;Lee, Suk-Ho;Kim, Do-Jin;Na, Moon-Jun;Uh, Soo-Taek;Kim, Yong-Hoon;Park, Choon-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.1
    • /
    • pp.46-53
    • /
    • 2002
  • Background: Pulmonary aspergilloma is relatively common in korea. It arises from the colonization and proliferation of Aspergillus in preexisting lung parenchymal cavities, in particular tuberculosis. The most common symptom in this disorder is hemoptysis, which mayor may not be massive and life threatening. A routine chest radiography and computed tomography (CT) are the most important diagnostic procedures. A surgical resection of the aspergilloma has recently been recommended, because of the relatively low incidence of postoperative complications than in the past. A more concentrated sample of patients with aspergilloma, who either underwent a thoracotomy or tested positive for aspergillus antibodies, were reviewed. Method : The medical records of twenty-two patients with aspergilloma, who had a proven thoracotomy (9 cases), or who tested positive for the diagnostic procedure and/or aspergillus antibodies (13 cases) from January 1995 to December 2000, were reviewed retrospectively. Results : The most common underlying lung disease was a current or old healed tuberculosis, and 3 patients had cultures of mycobacterium other than tuberculosis (MOTT). The mean time until the aspergilloma was detected 5.91 years in the healed tuberculosis cases. The others cases involved a lung abscess, bronchiectasis and without lung disease. The extrapulmonary disease was alcoholism and diabetes. Hemoptysis was most common in 72.7%. A computed tomography (CT) is useful for diagnosis. The right upper lobe, especially the posterior segment, is the most common location. Bronchial artery embolization is ineffective for a long term follow-up. A lobectomy is most common in a thoracotomy, and intra-operative and post-operative complications are rare. During follow-up, the mortality rate, not from the aspergilloma but from respiratory failure, was 13.6%. Conclusion : Aspergilloma is a common cavitary lung disease, It mainly arises from tuberculosis, either current or healed, but extra-pulmonary disease including alcoholism or diabetes are other possible risk factors. Their most common problem in aspergilloma is hemoptysis. Surgery has a low risk of post-operative complications and is recommended in relatively preserved lung function or healthy patients. Medical maneuvers including embolization, and the local insertion of certain materials needs to be studied more closely.

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.

A Study on the Availability of the On-Board Imager(OBI) and Cone-Beam CT(CBCT) in the Verification of Patient Set-up (온보드 영상장치(On-Board Imager) 및 콘빔CT(CBCT)를 이용한 환자 자세 검증의 유용성에 대한 연구)

  • Bak, Jino;Park, Sung-Ho;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.118-125
    • /
    • 2008
  • Purpose: On-line image guided radiation therapy(on-line IGRT) and(kV X-ray images or cone beam CT images) were obtained by an on-board imager(OBI) and cone beam CT(CBCT), respectively. The images were then compared with simulated images to evaluate the patient's setup and correct for deviations. The setup deviations between the simulated images(kV or CBCT images), were computed from 2D/2D match or 3D/3D match programs, respectively. We then investigated the correctness of the calculated deviations. Materials and Methods: After the simulation and treatment planning for the RANDO phantom, the phantom was positioned on the treatment table. The phantom setup process was performed with side wall lasers which standardized treatment setup of the phantom with the simulated images, after the establishment of tolerance limits for laser line thickness. After a known translation or rotation angle was applied to the phantom, the kV X-ray images and CBCT images were obtained. Next, 2D/2D match and 3D/3D match with simulation CT images were taken. Lastly, the results were analyzed for accuracy of positional correction. Results: In the case of the 2D/2D match using kV X-ray and simulation images, a setup correction within $0.06^{\circ}$ for rotation only, 1.8 mm for translation only, and 2.1 mm and $0.3^{\circ}$ for both rotation and translation, respectively, was possible. As for the 3D/3D match using CBCT images, a correction within $0.03^{\circ}$ for rotation only, 0.16 mm for translation only, and 1.5 mm for translation and $0.0^{\circ}$ for rotation, respectively, was possible. Conclusion: The use of OBI or CBCT for the on-line IGRT provides the ability to exactly reproduce the simulated images in the setup of a patient in the treatment room. The fast detection and correction of a patient's positional error is possible in two dimensions via kV X-ray images from OBI and in three dimensions via CBCT with a higher accuracy. Consequently, the on-line IGRT represents a promising and reliable treatment procedure.

A study on sagittal root position of maxillary anterior teeth in Korean (한국인에서 상악 전치의 시상 치근 위치에 대한 연구)

  • Kong, Hyun-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.88-94
    • /
    • 2020
  • Purpose: The purpose of this study was to analyze the sagittal root position of maxillary anterior teeth and report the frequency of each classification in Korean for immediate implant placement. Materials and Methods: A retrospective review of cone-beam computed tomography (cone-beam CT) images was conducted on 120 patients (60 male and 60 female) who fulfilled the inclusion criteria. After reorientation of the axis, cone-beam CT images were evaluated and the relationship of the sagittal root position (SRP) of the maxillary anterior teeth to its associated osseous housing was recorded. Class I, II, and III were classified respectively when the root was positioned on the labial, central, and palatal aspect of the alveolar bone. Class IV was the position that at least two thirds of the root is engaging both the labial and palatal cortical plates. Then, the angulation of the root axis and the alveolar bone axis was measured. Descriptive statistics and Kruskal-Wallis test were used to compare the angulation according to the root position and SRP class. Results: The frequency distribution of sagittal root position of maxillary anterior teeth indicated that 81.1%, 10.3%, 1.9%, and 6.7% were classified as Class I, II, III, and IV, respectively. The sagittal angulation at approximately 77.5% of central incisor, lateral incisor, and canine was < 20 degrees, but the angle at more than 42.7% of canine was ≥ 20 degrees. Within the class, the angulation was statistically significantly greater in Class I (16.19) compared to Class II (8.72) and Class III (9.93), and smaller in Class IV (3.79). Conclusion: Within the limitation of this study, a majority of the maxillary anterior roots were positioned close to the buccal cortical plate. However, some roots have very thin alveolar bone and sagittal angulation larger than 30 degrees. Therefore, cone-beam CT analyses of the sagittal root position and the sagittal angulation are recommended for the selection of the appropriate dental implant treatment approach.

The Assessment of Scattered Ray According to the Beam Thickness of Z-axis in MDCT(Multi Detector Computed Tomography) (MDCT(다배열검출기 전산화단층촬영장치)에서 Z-축의 빔 두께에 따른 산란선의 평가)

  • Ryu, Gwi-Bok;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Dong, Kyung-Rae;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • The purpose of this study is to measure scattered ray which is occurred except for Z-axis range of the detector in MDCT's iso-center and present the basic data about the standard for reduction of scattered ray. The development of MDCT brings out the enlargement of beam thickness to the patient's Z-axis, which distributes to the increase in exposure dose according to the rise of scattered ray. Also MDCT brings out the increase of scattered ray about 4times more than SDCT. To evaluate scattered ray according to the change of beam thickness on MDCT, we measured scattered ray of MDCT's Z-axis beam thickness by using one 16-slice CTs and two 64-slice CTs. We used the ionization chamber 60ml 2026C as the equipment of measurement. In our results, we found out that the change of scattered ray according to the beam thickness in the same kVp has increase of scattered ray. Secondly we found out the increase of scattered ray according to the increase of kVp. Lastly we found out the decrease of scattered ray according to the increase of the distance from the ionization chamber.

Burnt-out Metastatic Prostate Cancer

  • Shin, Dong Suk;Koo, Dong Hoe;Yoo, Suhyeon;Ju, Deok Yun;Jang, Cheol Min;Joo, Kwan Joong;Shin, Hyun Chul;Chae, Seoung Wan
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.2
    • /
    • pp.116-119
    • /
    • 2013
  • A burnt-out prostate cancer tumor is a very rare clinical entity. The term 'burnt-out' refers to a primary tumor that has spontaneously and nearly completely regressed without treatment. Since metastasis of prostate cancer is usually encountered in the presence of advanced disease, distant metastasis with an undetectable primary tumor is very rare. We report herein a case of a burnt-out prostate cancer tumor that metastasized to the thoracic (T) spine and caused cord compression. A 66-year-old man visited the Emergency Department due to weakness of both legs for the past two days. His blood and urine tests were normal at the time. His spine magnetic resonance imaging (MRI) scans looked like bone metastasis that involved the T-7 vertebral body and a posterior element, and caused spinal cord compression. Other images, including from the brain MRI, neck/chest/abdomino-pelvic computed tomography (CT) scan and 18F-fluorodeoxyglucose (FDG)-positron emission tomography (PET) and endoscopy, revealed no lesions that suggested malignancy. After total corpectomy T-7 and screw fixation/fusion at T5 to T10, the pathology report revealed a metastatic carcinoma that was strongly positive for prostate-specific antigen (PSA). The serum PSA value was 1.5 ng/mL. The transrectal 12-core prostate biopsy and ultrasonography showed no definitive hypoechoic lesion, but one specimen had slight (only 1%) adenocarcinoma with a Gleason score of 6 (3+3). The final diagnosis was burned-out prostate cancer with an initial normal PSA value. Although metastatic disease with an unknown primary origin was confirmed, a more aggressive approach in seeking the primary origin could provide a more specific treatment strategy and greater clinical benefit to patients.

Three Dimensional Study of Miniscrew about Installation Area and Angle (미니스크류 식립 각도 및 부위에 대한 3차원적 연구)

  • Jo, Hee-Sang;Lee, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.203-211
    • /
    • 2008
  • Minimizing damage to anatomical structure is a prerequisite for skeletal anchorage system to install a miniscrew. This research has focused on evaluating the stability and safety of installation in the maxillary molar buccal area, in which most miniscrews are installed clinically and initial fixation is weak. CT (computerized tomography)images were taken for surveying the possibility of damaging to adjucent teeth in accordance with installation angle. If we install a mini-screw($1.2{\times}6.0mm$) in the maxillary molar buccal area, it would be located generally in the 5~8mm upper of CEJ and 3~5mm inner of the cortical bone surface. We has measured the space between roots And comparison has been made for gender and the space between roots in accordance with the 3 different angles of installation(30 degree, 40 degree, 60 degree) in 3 categories. Category 1 : between 1st molar and 2nd molar Category 2 : between 1st molar and 2nd premolar Category 3 : between 1st premolar and 2nd premolar The result are as follow; 1. The space for category 1 was significantly small. 2. For the installation angle, it was safer to install with steeper angle in category 1 and category 2, but not in category 3. According to these results, the installation a miniscrew in category 2, 3 is safer than in category 1. And it is safer to install with steeper angle in category 1 and category 2.

A Case of Bronchiectasis with High Serum CA19-9 (혈중 CA19-9이 지속적으로 상승되었던 기관지 확장증 환자 1예)

  • Huh, Jung Hun;Lee, Su Mi;Koo, Tae Hyoung;Shin, Bong Chul;Um, Soo Jung;Yang, Doo Kyung;Lee, Soo-Keol;Son, Choonhee;Rho, Mee Sook;Kim, Ki Nam;Lee, Ki Nam;Choi, Pil Jo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.5
    • /
    • pp.383-386
    • /
    • 2008
  • An elevated serum CA19-9 level is an indication of pancreatic and biliary tract cancer. However, it has recently become known that nonmalignant gastrointestinal diseases and a variety of nonmalignant respiratory diseases, such as idiopathic interstial pneumonia, collagen vascular disease associated lung diseases, diffuse panbronchiolitis and bronchiectasis, can also show an elevated serum CA19-9 level. We recently encountered a case of bronchiectasis with persistently elevated serum CA19-9, but without any evidence of malignant disease in endoscopic retrograde pancreatocholangiography, abdominal computed tomography, and positron emission tomography. After serial follow-up of 3 years and 10 months, there was still no evidence of cancer. It is believed that the elevated serum CA19-9 level was due to bronchiectasis. An elevated serum CA19-9 level should be interpreted carefully with the patients' clinical condition.