• Title/Summary/Keyword: CT (computed tomography)

Search Result 2,650, Processing Time 0.036 seconds

Computed tomographic anatomy of hepatic artery in normal beagle dogs

  • Kim, Soochan;Jeong, Seongmok;Lee, Heechun;Lee, Youngwon;Choi, Hojung
    • Korean Journal of Veterinary Research
    • /
    • v.59 no.2
    • /
    • pp.55-58
    • /
    • 2019
  • This study was performed to examine the visualization and anatomical variants of the hepatic artery with dual-phase computed tomography (CT) angiography and three-dimensional volume rendering imaging analysis in clinically normal dogs. Seven healthy beagle dogs were enrolled and underwent dual CT angiography. Arterial phase images could be obtained with multi-detector CT angiography using the fixed-scan method in these dogs. Contrast enhancement of the hepatic parenchyma was quite minimal because of the unique blood supply system of the liver. In most dogs, the main hepatic arterial branches were the right lateral branch, left branch, and right medial branch. Although hepatic arterial variation appears to be common in dogs, only one dog in this study had the caudate lobar branch as the first branch of the hepatic artery. Further study on a larger number of dogs with CT images will be needed to identify and classify the pattern of hepatic arterial variations.

Computed Tomographic Diagnosis of Bronchiectasis in a Dog with Chronic Bronchopneumonia (만성 기관지폐염 견에서 컴퓨터단층촬영을 통한 기관지확장증 진단 1례)

  • Lim Chang-yun;Choi Ho-jung;Jeong Yu-cheol;Oh Sun-kyoung;Seo Eun-jung;Jung Joo-hyun;Choi Min-cheol;Yoon Junghee
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.431-434
    • /
    • 2005
  • A 2-year-old castrated male, Cocker spaniel dog with a history of chronic productive cough for 2 to 3 months and with unsuccessful treatment was referred to Veterinary Medical Teaching Hospital, Seoul National University. On thoracic radiographs, there were alveolar infiltrations at left cranial and right caudal lung fields, and soft-tissue opacity round to oval images at overall lung field. The bronchi were dilated, tortuous and not tapered. Abnormal air was accumulated focally in the caudodorsal lung fields. To scrutinize the soft-tissue opacity image and accumulated air, computed tomography (CT) was done. On CT images, severe cylindrical or tubular bronchiectasis was confirmed. And the soft-tissue opacity images were found in the dilated bilated and thought to complexes of mucous plugs, inflammatory cells, necrotic and fibrotic tissue. The dog was dead next day to the CT scan, so necropsy and histopathologic examination were perfermed. On the histopathology, there were cylindrical bronhiectasis and severe diffuse chronic fibrinous necropurulent bronchitis and bronchopneumonia. In this case, it was difficult to diagnose the bronchiectasis only with radiography due to the concurrent lesions, such as pulmonary infiltrations and mucous plugs, which was identified by computed tomography. Thus, computed tomography is considered as a useful modality to confirm tile bronchiectasis camouflaged by the concurrent lesion.

Evaluation of the postoperative maxillary sinus with computed tomography

  • Kim Hee-Kyung;Heo Min-Suk;Lee Sam-Sun;Choi Hyun-Bae;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.32 no.4
    • /
    • pp.195-200
    • /
    • 2002
  • Purpose: To evaluate the computed tomographic appearances of post-operative maxillary sinuses. Materials and Methods: 33 asymptomatic cases of post-operative maxillary sinus without evidence of any pathologic changes and clinical symptoms were selected. CT images were classified as opacification, soft tissue shadow, anterior wall depression, naso-antral communication, and compartmentalization. The relationships between the CT image and the age of patients at the time of operatation, and between the CT image and the duration of time elapsed since the surgical procedure were evaluated. Results: The most commonly presented radiological characteristics that occurred after the Caldwell-Luc procedure were opacification and soft tissue shadow. Anterior wall depression and naso-antral communication were radiographic indications that a Caldwell-Luc operation had been carried out. The age of patients when they had been first operated on, and the duration between the surgical procedure and the time of evaluation had no effect on the CT appearances of normal changes. In cases involving a longer time interval between the antral surgery and evaluation, the anterior wall depression with bony healing was more commonly observed than soft tissue healing. Conclusion: The radiographic information regarding the normal healing state using computed tomography can distinguish post-operative changes from inflammatory and cystic disease in patients who have undergone a Caldwell-Luc type of radical maxillary antrostomy.

  • PDF

Automatic Segmentation of Stomach from the CT Image (CT 영상에서 위(Stomach)의 자동적인 추출)

  • 박승란;박종원;노승무
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10b
    • /
    • pp.428-430
    • /
    • 1999
  • 컴퓨터 단층촬영(Computed Tomography : CT)내의 위(stomach)에 대하여 연구하였다. 위는 모양이 변하면서 움직이는 정기이며 음식물로 채워진 부분과 공기로 채워진 부분으로 나뉘어져 있다. 위의 명암 값 정보와 위치 정보를 이용하여 자동적으로 추출을 한 다음, 음식물로 채워진 부분과 공기로 채워진 부분, 그리고 전체적인 위의 체적을 계산할 수 있는 알고리즘을 구현하였다.

  • PDF

The Effects of a Vasodilator on Transluminal Attenuation Gradient at Coronary Computed Tomography Angiography

  • Moon Sung Kim;Eun-Ju Kang;Hyun Jin Kim;Moo Hyun Kim;Ki-Nam Lee
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1285-1293
    • /
    • 2020
  • Objective: To evaluate the effects of vasodilators on contrast enhancement and transluminal attenuation gradient (TAG) of coronary arteries at coronary computed tomography angiography (CCTA). Materials and Methods: We retrospectively reviewed CCTA scans of patients who underwent double-acquisition CCTA; CCTA without a vasodilator, and CCTA during a intravenous (IV) infusion of nitrate. Among them, we enrolled 19 patients who had no significant atherosclerotic lesions or coronary spasms. In the control group, 28 patients were enrolled who showed normal coronary arteries on CCTA, which was acquired by a conventional method (sublingual vasodilator). We measured the TAG and Hounsfield units for each of the three major epicardial coronary arteries (reported as 'ProxHU') and then compared the results between the nitrate administration methods (CT without vasodilator [CTpre], CT with IV vasodilator [CTiv], and CT with sublingual vasodilator [CTsub]). Results: The mean TAG showed a significant difference between the coronary arteries (right coronary artery [RCA] > left anterior descending artery [LAD] > left circumflex artery [LCX], p < 0.05), while there was no difference in ProxHU of each coronary artery in all three types of nitrate administration methods (p > 0.05). The TAG of CTpre group showed steeper slope than those of vasodilator groups (CTiv and CTsub) on LAD and LCX ([LAD: CTpre = -22.1 ± 6.66, CTiv = -16.76 ± 5.78, and CTsub = -16.47 ± 5.78, p = 0.005], [LCX: CTpre = -31.26 ± 17.43, CTiv = -23.74 ± 14.06, and CTsub = -20.94 ± 12.15, p = 0.051]), while that of RCA showed no significant differences (p = 0.600). When comparing proxHU, CTiv showed higher proxHU than that of CTpre or CTsub, especially on LCX (CTpre = 426.7 ± 68.3, CTiv = 467.9 ± 84.9, and CTsub = 404.9 ± 63.3, p = 0.013). ProxHU showed a negative correlation with TAG on all three of methods (r = -0.280, p < 0.001). Conclusion: TAG in CCTA was significantly affected by vasodilator administration. Both TAG and ProxHU of coronary arteries tend to increase with vasodilator administration on CCTA.

Development of X-ray Micro Computed Tomography and Applications (미세 X선 단층촬영 기법의 개발과 적용)

  • Kim, Seung-Gon;Lim, Jae-Hong;Kim, Bo-Heum;Lee, Eui-Jae;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.2
    • /
    • pp.45-50
    • /
    • 2010
  • The objective of this study is to elucidate the feasibility of synchrotron X-ray micro CT as a non-destructive imaging method to visualize the three-dimensional morphological structures of biological and non-biological samples. The experiments were conducted in 7B2 X-ray micro CT beamline in Pohang Accelerate Laboratory (PAL). A rotational 3-axis stage was specially designed for $0^{\circ}-180^{\circ}$ scanning of test samples. Preliminary tests were performed for opaque samples including a mosquito head, a plant seed and gas diffusion layer (GDL) of polymer electrolyte fuel cell to verify the feasibility of the X-ray micro CT. It visualized clearly the internal structure of all the test samples, supporting its usefulness.

Computer-aided Design and Fabrication of Bio-mimetic Scaffold for Tissue Engineering Using the Triply Periodic Minimal Surface (삼중 주기적 최소곡면을 이용한 조직공학을 위한 생체모사 스캐폴드의 컴퓨터응용 설계 및 제작)

  • Yoo, Dong-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.7
    • /
    • pp.834-850
    • /
    • 2011
  • In this paper, a novel tissue engineering scaffold design method based on triply periodic minimal surface (TPMS) is proposed. After generating the hexahedral elements for a 3D anatomical shape using the distance field algorithm, the unit cell libraries composed of triply periodic minimal surfaces are mapped into the subdivided hexahedral elements using the shape function widely used in the finite element method. In addition, a heterogeneous implicit solid representation method is introduced to design a 3D (Three-dimensional) bio-mimetic scaffold for tissue engineering from a sequence of computed tomography (CT) medical image data. CT image of a human spine bone is used as the case study for designing a 3D bio-mimetic scaffold model from CT image data.

Diagnosis of Persistent Primitive Olfactory Artery Using Computed Tomography Angiography

  • Kim, Myoung-Soo;Lee, Ghi-Jai
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.5
    • /
    • pp.290-291
    • /
    • 2011
  • Persistent primitive olfactory artery (PPOA) is a rare anomaly of the anterior cerebral artery. We present one case of PPOA incidentally diagnosed with the aid of computed tomography (CT) angiography. A 24-year-old woman was admitted to our hospital after sudden onset of vertigo. Three-dimensional CT angiography revealed an anomalous artery arising from the terminal portion of the right internal carotid artery. The proximal portion of the anomalous artery coursed anteromedially and made a hairpin turn posterosuperior to the midline. PPOA may be overlooked because of its rarity, but CT angiography can be useful in detecting this rare vascular anomaly. Follow-up study is necessary in our case to confirm whether an aneurysm occurs on the PPOA.

A study on the finite element modeling of femur based marching cube algorithm (Marching cube 알고리즘을 이용한 대퇴골의 유한요소 모델링에 관한 연구)

  • 곽명근;오택열;변창환;이은택;유용석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1074-1077
    • /
    • 2002
  • Biomechanical behavior of the human femur is very important in various clinical situations. In this study, the data of FE models based on DICOM file exported from Computed tomography(CT). We generated FE models(voxel model, tetra model) of human femur using CT slide image. We compared them with Yon Mises stress results derived from finite element analysis(FEA). Comparing the two models, we found a correlation of them. As a result, the tetra model based proposed marching cube algorithm is a valid and accurate method to predict parameters of the complex biomechanical behavior of human femur.

  • PDF

Optical Skin-fat Thickness Measurement Using Miniaturized Chip LEDs: A Preliminary Human Study

  • Ho, Dong-Su;Kim, Ee-Hwa;Hwang, In-Duk;Shin, Kun-Soo;Oh, Jung-Taek;Kim, Beop-Min
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.304-309
    • /
    • 2009
  • We tested the feasibility of measuring fat thickness using a miniaturized chip LED sensor module, testing 12 healthy female subjects. The module consisted of a single detector and four sources at four different source-detector distances (SD). A segmental curve-fitting procedure was applied, using an empirical algorithm obtained by Monte-Carlo simulation, and fat thicknesses were estimated. These thicknesses were compared to computed-tomography (CT) results; the correlation coefficient between CT and optical measurements was 0.932 for bicep sites. The mean percentage error between the two measurements was 13.12%. We conclude that fat thickness can be efficiently measured using the simple sensor module.