• Title/Summary/Keyword: CT선량

Search Result 636, Processing Time 0.025 seconds

Multiple Daily Fractionated RT for Malignant Glioma (악성 성상세포종과 다형성 교아종 치료에 있어서 다분할 방사선 치료와 단순분할 방사선치료에 대한 성적비교)

  • Yang Kang Mo;Chang Hye Sook;Ahn Seoung Do;Choi Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.151-158
    • /
    • 1994
  • Since Jan. 1992, authors have conducted a pilot study to treat malignant glioma with multiple daily fractionated(MDF) radiation therapy and this paper presents the outcome compared MDF to conventional factionated(CF) radiation therapy Between Sep. 1989 and Jan. 1993, forty three patients with high grade glioma of brain except brain stem glioma were treated: nineteen patients were treated with CF radiation therapy and 24 patients were treated with MDF radiation therapy. In CF radiation therapy, total dose was 6300cGy/35fx in 7 weeks, which 5040cGy was delivered to the initial target volume and 1260cGy to reduced target volume. And in MDF radiation therapy, total dose was 6400cGy/40fx in 4 weeks, which 3200cGy was delivered to the initial target volume as 160cGy 2 times daily 6hr apart. All patients had histologically confirmed anaplastic astrocytoma(AA) of glioblastoma multiforme (GBM) with stereotactic biopsy or craniotomy for subtotal or gross tumor resection. The range of follow-up was 7 months to 4 years with a median follow-up of 9 months. The Median survival from surgery was 9 months for all patients. The median survival was 9 months and 10 months for MDF group and CF group and 10 months and 9.5 months for glioblastoma multiforme and anaplastic astrocytoma, respectively. In 36 patients with follow-up CT scan or MRI scan, disease status was evaluated according to treatment groups, Four patients(GBM:3, AA:1) of 21 patients in MDF group, were alive with no evidence of disease, while none of patient was alive with no evidence of disease in CF group. The progression of disease had occurred in 20 patients, 11 patients and 9 patients in MDF group and CF group, respectively All of these patients showed in-field progression of disease, Four of 11 patients($27\%$) in MDF group showed the new leasion outside of the treatment field, while 5 of 9 patients($56\%$) in CF group. In our study the prognosis was not influenced by age, KPS, grade, extent of surgery and different fractional scheduled radiation therapy. Authors concluded that MDF regimen was well tolerated and shortened the treatment period from 7 weeks to 4 weeks without compromising results. We believe that further follow-up is needed to assess the role of MDF.

  • PDF

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

Bladder Preserving Treatment in Patients with Muscle Invasive Bladder Cancer (근침윤성 방광암 환자의 방광 보존적 치료 결과)

  • Yu, Jeong-Il;Oh, Dong-Ryol;Huh, Seung-Jae;Choi, Han-Yong;Lee, Hyon-Moo;Jeon, Seong-Soo;Yim, Ho-Young;Kim, Won-Suk;Lim, Do-Hoon;Ahn, Yong-Chan;Park, Won
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.70-78
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: This study analyzed the tumor response, overall survival, progression free survival and related prognostic factors in patients with muscle invasive bladder cancer subjected to bladder preserving treatment. $\underline{Materials\;and\;Methods}$: Between August 1995 and June 2004, 37 patients with muscle invasive (transitional cell carcinoma, clinically stage T2-4) bladder cancer were enrolled for the treatment protocol of bladder preservation. There were 33 males and 4 females, and the median age was 67 years (range $38{\sim}86\;years$). Transurethral resection of the bladder (TURB) was performed in 17 patients who underwent complete resection. The median radiation dose administered was 64.8 Gy (range $55.8{\sim}67\;Gy$). The survival rate was calculated by the Kaplan-Meier method. $\underline{Results}$: An evaluation of the response rate was determined by abdomen-pelvic CT and cystoscopy at three months after radiotherapy. A complete response was seen in 17 patients (46%). The survival rate at three years was 54.7%, with 54 months of median survival (range $3{\sim}91$ months). During the study, 17 patients died and 13 patients had died from bladder cancer. The progression free survival rate at three years was 37.2%. There were 24 patients (64.9%) who had disease recurrence: 16 patients (43.2%) had local recurrence, 6 patients (16.2%) had a distant recurrence, and 2 patients (5.4%) had both a local and distant recurrence. The survival rate (p=0.0009) and progression free survival rates (p=0.001) were statistically significant when compared to the response rate after radiotherapy. $\underline{Conclusion}$: The availability of complete TURB and appropriate chemoradiotherapy were important predictors for bladder preservation and survival.

The Efficacy of the Change in Belly Board Aperture Location by the Addition of Bladder Compression Device for Radiotherapy of Rectal Cancer (직장암 환자의 골반 방사선치료에서 벨리보드 하위 경계 위치 변화의 영향)

  • Yoon, Hong-In;Chung, Yoon-Sun;Kim, Joo-Ho;Park, Hyo-Kuk;Lee, Sang-Kyu;Kim, Young-Suk;Choi, Yun-Seon;Kim, Mi-Sun;Lee, Ha-Yoon;Chang, Jee-Suk;Cha, Hye-Jung;Seong, Jin-Sil;Keum, Ki-Chang;Koom, Woong-Sub
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.231-237
    • /
    • 2010
  • Purpose: We investigated the effect of location changes in the inferior border of the belly board (BB) aperture by adding a bladder compression device (BCD). Materials and Methods: We respectively reviewed data from 10 rectal cancer patients with a median age 64 years (range, 45~75) and who underwent computed tomography (CT) simulation with the use of BB to receive pelvic radiotherapy between May and September 2010. A CT simulation was again performed with the addition of BCD since small bowel (SB) within the irradiated volume limited boost irradiation of 5.4 Gy using the cone down technique after 45 Gy. The addition of BCD made the inferior border of BB move from symphysis pubis to the lumbosacral junction (LSJ). Results: Following the addition of BCD, the irradiated volumes of SB and the abdominopelvic cavity (APC) significantly decreased ($174.3{\pm}89.5mL$ vs. $373.3{\pm}145.0mL$, p=0.001, $1282.6{\pm}218.7mL$ vs. $1,571.9{\pm}158mL$, p<0.001, respectively). Bladder volume within the treated volume increased with BCD ($222.9{\pm}117.9mL$ vs. $153.7{\pm}95.5mL$, p<0.001). The ratio of irradiated bladder volume to APC volume with BCD ($33.5{\pm}14.7%$) increased considerably compared to patients without a BCD ($27.5{\pm}13.1%$) (p<0.001), and the ratio of irradiated SB to APC volume decreased significantly with BCD ($13.9{\pm}7.6%$ vs. $24.2{\pm}10.2%$, p<0.001). The ratios of the irradiated SB volume and irradiated bladder volume to APC volume negatively correlated (p=0.001). Conclusion: This study demonstrated that the addition of BCD, which made the inferior border of BB move up to the LSJ, increased the ratio of the bladder to APC volume and as a result, decreased the irradiated volume of SB.

HW/SW Partitioning Techniques for Multi-Mode Multi-Task Embedded Applications (멀티모드 멀티태스크 임베디드 어플리케이션을 위한 HW/SW 분할 기법)

  • Kim, Young-Jun;Kim, Tae-Whan
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.8
    • /
    • pp.337-347
    • /
    • 2007
  • An embedded system is called a multi-mode embedded system if it performs multiple applications by dynamically reconfiguring the system functionality. Further, the embedded system is called a multi-mode multi-task embedded system if it additionally supports multiple tasks to be executed in a mode. In this Paper, we address a HW/SW partitioning problem, that is, HW/SW partitioning of multi-mode multi-task embedded applications with timing constraints of tasks. The objective of the optimization problem is to find a minimal total system cost of allocation/mapping of processing resources to functional modules in tasks together with a schedule that satisfies the timing constraints. The key success of solving the problem is closely related to the degree of the amount of utilization of the potential parallelism among the executions of modules. However, due to an inherently excessively large search space of the parallelism, and to make the task of schedulabilty analysis easy, the prior HW/SW partitioning methods have not been able to fully exploit the potential parallel execution of modules. To overcome the limitation, we propose a set of comprehensive HW/SW partitioning techniques which solve the three subproblems of the partitioning problem simultaneously: (1) allocation of processing resources, (2) mapping the processing resources to the modules in tasks, and (3) determining an execution schedule of modules. Specifically, based on a precise measurement on the parallel execution and schedulability of modules, we develop a stepwise refinement partitioning technique for single-mode multi-task applications. The proposed techniques is then extended to solve the HW/SW partitioning problem of multi-mode multi-task applications. From experiments with a set of real-life applications, it is shown that the proposed techniques are able to reduce the implementation cost by 19.0% and 17.0% for single- and multi-mode multi-task applications over that by the conventional method, respectively.

Development of Model Plans in Three Dimensional Conformal Radiotherapy for Brain Tumors (뇌종양 환자의 3차원 입체조형 치료를 위한 뇌내 주요 부위의 모델치료계획의 개발)

  • Pyo Hongryull;Lee Sanghoon;Kim GwiEon;Keum Kichang;Chang Sekyung;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.1-16
    • /
    • 2002
  • Purpose : Three dimensional conformal radiotherapy planning is being used widely for the treatment of patients with brain tumor. However, it takes much time to develop an optimal treatment plan, therefore, it is difficult to apply this technique to all patients. To increase the efficiency of this technique, we need to develop standard radiotherapy plant for each site of the brain. Therefore we developed several 3 dimensional conformal radiotherapy plans (3D plans) for tumors at each site of brain, compared them with each other, and with 2 dimensional radiotherapy plans. Finally model plans for each site of the brain were decide. Materials and Methods : Imaginary tumors, with sizes commonly observed in the clinic, were designed for each site of the brain and drawn on CT images. The planning target volumes (PTVs) were as follows; temporal $tumor-5.7\times8.2\times7.6\;cm$, suprasellar $tumor-3\times4\times4.1\;cm$, thalamic $tumor-3.1\times5.9\times3.7\;cm$, frontoparietal $tumor-5.5\times7\times5.5\;cm$, and occipitoparietal $tumor-5\times5.5\times5\;cm$. Plans using paralled opposed 2 portals and/or 3 portals including fronto-vertex and 2 lateral fields were developed manually as the conventional 2D plans, and 3D noncoplanar conformal plans were developed using beam's eye view and the automatic block drawing tool. Total tumor dose was 54 Gy for a suprasellar tumor, 59.4 Gy and 72 Gy for the other tumors. All dose plans (including 2D plans) were calculated using 3D plan software. Developed plans were compared with each other using dose-volume histograms (DVH), normal tissue complication probabilities (NTCP) and variable dose statistic values (minimum, maximum and mean dose, D5, V83, V85 and V95). Finally a best radiotherapy plan for each site of brain was selected. Results : 1) Temporal tumor; NTCPs and DVHs of the normal tissue of all 3D plans were superior to 2D plans and this trend was more definite when total dose was escalated to 72 Gy (NTCPs of normal brain 2D $plans:27\%,\;8\%\rightarrow\;3D\;plans:1\%,\;1\%$). Various dose statistic values did not show any consistent trend. A 3D plan using 3 noncoplanar portals was selected as a model radiotherapy plan. 2) Suprasellar tumor; NTCPs of all 3D plans and 2D plans did not show significant difference because the total dose of this tumor was only 54 Gy. DVHs of normal brain and brainstem were significantly different for different plans. D5, V85, V95 and mean values showed some consistent trend that was compatible with DVH. All 3D plans were superior to 2D plans even when 3 portals (fronto-vertex and 2 lateral fields) were used for 2D plans. A 3D plan using 7 portals was worse than plans using fewer portals. A 3D plan using 5 noncoplanar portals was selected as a model plan. 3) Thalamic tumor; NTCPs of all 3D plans were lower than the 2D plans when the total dose was elevated to 72 Gy. DVHs of normal tissues showed similar results. V83, V85, V95 showed some consistent differences between plans but not between 3D plans. 3D plans using 5 noncoplanar portals were selected as a model plan. 4) Parietal (fronto- and occipito-) tumors; all NTCPs of the normal brain in 3D plans were lower than in 2D plans. DVH also showed the same results. V83, V85, V95 showed consistent trends with NTCP and DVH. 3D plans using 5 portals for frontoparietal tumor and 6 portals for occipitoparietal tumor were selected as model plans. Conclusion : NTCP and DVH showed reasonable differences between plans and were through to be useful for comparing plans. All 3D plans were superior to 2D plans. Best 3D plans were selected for tumors in each site of brain using NTCP, DVH and finally by the planner's decision.

Implant Isolation Characteristics for 1.25 Gbps Monolithic Integrated Bi-Directional Optoelectronic SoC (1.25 Gbps 단일집적 양방향 광전 SoC를 위한 임플란트 절연 특성 분석)

  • Kim, Sung-Il;Kang, Kwang-Yong;Lee, Hai-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.52-59
    • /
    • 2007
  • In this paper, we analyzed and measured implant isolation characteristics for a 1.25 Gbps monolithic integrated hi-directional (M-BiDi) optoelectronic system-on-a-chip, which is a key component to constitute gigabit passive optical networks (PONs) for a fiber-to-the-home (FTTH). Also, we derived an equivalent circuit of the implant structure under various DC bias conditions. The 1.25 Gbps M-BiDi transmit-receive SoC consists of a laser diode with a monitor photodiode as a transmitter and a digital photodiode as a digital data receiver on the same InP wafer According to IEEE 802.3ah and ITU-T G.983.3 standards, a receiver sensitivity of the digital receiver has to satisfy under -24 dBm @ BER=10-12. Therefore, the electrical crosstalk levels have to maintain less than -86 dB from DC to 3 GHz. From analysed and measured results of the implant structure, the M-BiDi SoC with the implant area of 20 mm width and more than 200 mm distance between the laser diode and monitor photodiode, and between the monitor photodiode and digital photodiode, satisfies the electrical crosstalk level. These implant characteristics can be used for the design and fabrication of an optoelectronic SoC design, and expended to a mixed-mode SoC field.

Clinical Features of Patients with Lung Cancer and Upper Aerodigestive Tract Cancer (폐암과 상부소화호흡기암이 동반된 환자의 경우 임상적 특징)

  • Lee, Chang Youl;Chung, Jae Hee;Chang, Yoon Soo;Kim, Se Kyu;Kim, Hyung Jung;Chang, Joon;Kim, Sung Kyu;Ahn, Chul Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.4
    • /
    • pp.284-289
    • /
    • 2007
  • Background: To define the clinical features of patients with lung and upper aerodigestive tract cancer through a review of the histopathology, clinical features and follow-up results. Methods: Patients with lung and upper aerodigestive tract cancer who were diagnosed in Young dong Severance Hospital from 1992 to 2005, were retrospectively reviewed. The clinical data, radiologic findings, pathologic findings, treatment modalities were evaluated. Result: There was a total of 20 patients with aerodigestive tract cancer who were diagnosed with lung cancer over a 13 years period. The mean age was $58.45{\pm}15.09$ years and 19 cases were male. There were 14 smokers with an average pack year of 46 years. Twelve patients had aerodigestive tract cancer and later developed lung cancer, and 5 lung cancer patients were later diagnosed with aerodigestive tract cancer. Conclusion: These results suggest that cancers of the aerodigestive tract and lung can arise as either dependent or independent events and most aerodigestive tract cancer patients who developed lung cancer are not treated properly. Therefore, regular low dose chest CT with close suspicion is needed to properly manage upper aerodigestive tract cancer patients.

Preliminary Results of 3-Dimensional Conformal Radiotherapy for Primary Unresectable Hepatocellular Carcinoma (절제 불가능한 원발성 간암의 입체조형 방사선치료의 초기 임상 결과)

  • Keum Ki Chang;Park Hee Chul;Seong Jinsil;Chang Sei Kyoung;Han Kwang Hyub;Chon Chae Yoon;Moon Young Myoung;Kim Gwi Eon;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.123-129
    • /
    • 2002
  • Purpose : The purpose of this study 띤as to determine the potential role of three-dimensional conformal radiotherapy (3D-CRT) in the treatment of primary unresectable hepatocellular carcinoma. The preliminary results on the efficacy and the toxicity of 3D-CRT are reported. Materials and Methods : Seventeen patients were enrolled in this study, which was conducted prospectively from January 1995 to June 1997. The exclusion criteria included the presence of extrahepatic metastasis, liver cirrhosis of Child-Pugh classification C, tumors occupying more than two thirds of the entire liver, and a performance status of more than 3 on the ECOG scale. Two patients were treated with radiotherapy only while the remaining 15 were treated with combined transcatheter arterial chemoembolization. Radiotherapy was given to the field including the tumor plus a 1.5 cm margin using a 3D-CRT technique. The radiation dose ranged from $36\~60\;Gy$ (median; 59.4 Gy). Tumor response was based on a radiological examination such as the CT scan, MR imaging, and hepatic artery angiography at $4\~8$ weeks following the completion of treatment. The acute and subacute toxicities were monitored. Results : An objective response was observed in 11 out of 17 patients, giving a response rate of $64.7\%$. The actuarial survival rate at 2 years was $21.2\%$ from the start of radiotherapy (median survival; 19 months). Six patients developed a distant metastasis consisting of a lung metastasis in 5 patients and bone metastasis in one. The complications related to 30-CRT were gastro-duodenitis $(\geq\;grade\;2)$ in 2 patients. There were no treatment related deaths and radiation induced hepatitis. Conclusion : The preliminary results show that 3D-CRT is a reliable and effective treatment modality for primary unresectable hepatocellular carcinoma compared to other conventional modalities. Further studies to evaluate the definitive role of the 3D-CRT technique in the treatment of primary unresectable hepatocellular carcinoma are needed.

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF