• Title/Summary/Keyword: CT/MRI

Search Result 898, Processing Time 0.026 seconds

Cross-Sectional and Skeletal Anatomy of Long-tailed Gorals (Naemorhedus caudatus) Using Imaging Evaluations

  • Sangjin Ahn;Woojin Shin;Yujin Han;Sohwon Bae;Cheaun Cho ;Sooyoung Choi;Jong-Taek Kim
    • Journal of Veterinary Science
    • /
    • v.24 no.4
    • /
    • pp.60.1-60.8
    • /
    • 2023
  • Background: Accurate diagnosis of diseases in animals is crucial for their treatment, and imaging evaluations such as radiographs, computed tomography (CT), and magnetic resonance imaging (MRI) are important tools for this purpose. However, a cross-sectional anatomical atlas of normal skeletal and internal organs of long-tailed gorals (Naemorhedus caudatus) has not yet been prepared for diagnosing their diseases. Objectives: The objective of this study was to create an anatomical atlas of gorals using CT and MRI, which are imaging techniques that have not been extensively studied in this type of wild animal in Korea. Methods: The researchers used CT and MRI to create an anatomical atlas of gorals, and selected 37 cross-sections from the head, thoracic, lumbar, and sacrum parts of gorals to produce an average cross-sectional anatomy atlas. Results: This study successfully created an anatomical atlas of gorals using CT and MRI. Conclusions: The atlas provides valuable information for the diagnosis of diseases in gorals, which can improve their treatment and welfare. The study highlights the importance of developing cross-sectional anatomical atlases of gorals to diagnose and treat their diseases effectively.

Diagnostic Performance and Prognostic Relevance of FDG Positron Emission Tomography/Computed Tomography for Patients with Extrahepatic Cholangiocarcinoma

  • Nam Hee Kim;Sung Ryol Lee;Young Hwan Kim;Hong Joo Kim
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1355-1366
    • /
    • 2020
  • Objective: We aimed to evaluate the diagnostic value and prognostic relevance of FDG positron emission tomography/computed tomography (PET-CT) in extrahepatic cholangiocarcinoma patients. Materials and Methods: This study included 234 extrahepatic cholangiocarcinoma patients who underwent FDG PET-CT between June 2008 and February 2016. The diagnostic performance of FDG PEG-CT was compared to that of contrast-enhanced multidetector row CT (MDCT) and MRI. Independent prognosticators for poor survival were also assessed. Results: The sensitivity of FDG PET-CT for detecting primary tumor and regional lymph node metastases was lower than that of MDCT or MRI (p < 0.001), whereas the specificity and positive predictive value for detecting regional lymph nodes metastases was significantly better in FDG PET-CT compared to MDCT and MRI (all p < 0.001). There was no significant difference in the diagnostic yield of distant metastases detection among three diagnostic imaging techniques. In a multivariate analysis, maximum standardized uptake values (SUVmax) of the primary tumor (adjusted hazard ratio [HR], 1.75; 95% confidence interval [CI], 1.13-2.69) and of the metastatic lesions ≥ 5 (adjusted HR, 8.10; 95% CI, 1.96-33.5) were independent contributors to poor overall survival in extrahepatic cholangiocarcinoma patients. In a subgroup analysis of 187 patients with periductal infiltrating type of cholangiocarcinoma, an SUVmax of the primary tumor ≥ 5 was associated with an increased risk of regional lymph node (adjusted odds ratio [OR], 1.60; 95% CI, 0.55-4.63) and distant metastases (adjusted OR, 100.57; 95% CI, 3.94-2567.43) at diagnosis as well as with poor overall survival (adjusted HR, 1.81; 95% CI, 1.04-3.15). Conclusion: FDG PET-CT showed lower sensitivity for detecting primary tumor and regional lymph node involvement than MDCT and MRI. However, the SUVmax of primary tumors and metastatic lesions derived from FDG PET-CT could have significant implications for predicting prognoses in extrahepatic cholangiocarcinoma patients.

Multidetector CT (MDCT) Arthrography in the Evaluation of Shoulder Pathology: Comparison with MR Arthrography and MR Imaging with Arthroscopic Correlation (Multidetector CT arthrography를 이용한 견관절 병변의 진단 - MRI, MR arthrography와의 비교 -)

  • Kim, Jae-Yoon;Gong, Hyun-Sik;Kim, Woo-Sung;Choi, Jung-Ah;Kim, Byung-Ho;Oh, Joo-Han
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.1
    • /
    • pp.73-82
    • /
    • 2006
  • Purpose: The purpose of the present study was to evaluate the diagnostic efficacy of CT arthrography (CTA) in the assessment of various shoulder pathologies, compared with MR arthrography (MRA) and MRI with arthroscopic correlation. Materials and Methods: CTA in 84 patients, MRA in 70 patients, and MRI in 27 patients were obtained. A radiologist interpreted each image for 5 pathologies: Bankart, SLAP, Hill-Sachs lesion, full-thickness, and partial-thickness rotator cuff tear. Detailed arthroscopic reports were compared with CTA, MRA, and MRI. The sensitivity, specificity, predictive values, and accuracy were calculated. The agreement between each diagnostic modality and arthroscopy was calculated. Diagnostic efficacy was assessed by the areas under the receiver operating characteristic (ROC) curves. Results: The diagnostic values of all three imaging groups were comparable to each other for Bankart, SLAP, Hills-Sachs, and full-thickness cuff tear lesions, but those of CTA were lower than MRI and MRA for partial-thickness cuff tears. The areas under the ROC curves for CTA, MRA, and MRI were not significantly different for all pathologies, except for partial-thickness cuff tears. Conclusion: CTA was equally competent to MRA or MRI in demonstrating Bankart, Hill-Sachs lesions, SLAP, and full thickness rotator cuff tears but not as efficient in diagnosing partial thickness rotator cuff tears.

Relationship between 18F-FDG PET/CT Semi-Quantitative Parameters and International Association for the Study of Lung Cancer, American Thoracic Society/European Respiratory Society Classification in Lung Adenocarcinomas

  • Lihong Bu;NingTu;Ke Wang;Ying Zhou;Xinli Xie;Xingmin Han;Huiqin Lin;Hongyan Feng
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.112-123
    • /
    • 2022
  • Objective: To investigate the relationship between 18F-FDG PET/CT semi-quantitative parameters and the International Association for the Study of Lung Cancer, American Thoracic Society/European Respiratory Society (IASLC/ATS/ERS) histopathologic classification, including histological subtypes, proliferation activity, and somatic mutations. Materials and Methods: This retrospective study included 419 patients (150 males, 269 females; median age, 59.0 years; age range, 23.0-84.0 years) who had undergone surgical removal of stage IA-IIIA lung adenocarcinoma and had preoperative PET/CT data of lung tumors. The maximum standardized uptake values (SUVmax), background-subtracted volume (BSV), and background-subtracted lesion activity (BSL) derived from PET/CT were measured. The IASLC/ATS/ERS subtypes, Ki67 score, and epidermal growth factor/anaplastic lymphoma kinase (EGFR/ALK) mutation status were evaluated. The PET/CT semi-quantitative parameters were compared between the tumor subtypes using the Mann-Whitney U test or the Kruskal-Wallis test. The optimum cutoff values of the PET/CT semi-quantitative parameters for distinguishing the IASLC/ATS/ERS subtypes were calculated using receiver operating characteristic curve analysis. The correlation between the PET/CT semi-quantitative parameters and pathological parameters was analyzed using Spearman's correlation. Statistical significance was set at p < 0.05. Results: SUVmax, BSV, and BSL values were significantly higher in invasive adenocarcinoma (IA) than in minimally IA (MIA), and the values were higher in MIA than in adenocarcinoma in situ (AIS) (all p < 0.05). Remarkably, an SUVmax of 0.90 and a BSL of 3.62 were shown to be the optimal cutoff values for differentiating MIA from AIS, manifesting as pure ground-glass nodules with 100% sensitivity and specificity. Metabolic-volumetric parameters (BSV and BSL) were better potential independent factors than metabolic parameters (SUVmax) in differentiating growth patterns. SUVmax and BSL, rather than BSV, were strongly or moderately correlated with Ki67 in most subtypes, except for the micropapillary and solid predominant groups. PET/CT parameters were not correlated with EGFR/ALK mutation status. Conclusion: As noninvasive surrogates, preoperative PET/CT semi-quantitative parameters could imply IASLC/ATS/ERS subtypes and Ki67 index and thus may contribute to improved management of precise surgery and postoperative adjuvant therapy.

Leak Sign on Dynamic-Susceptibility-Contrast Magnetic Resonance Imaging in Acute Intracerebral Hemorrhage

  • Park, Ji Kang;Hong, Dae Young;Jin, Sun Tak;Lee, Dong-Woo;Pyun, Hae Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.3
    • /
    • pp.154-161
    • /
    • 2020
  • Purpose: A CT angiography spot sign (CTA-spot) is a significant predictor of the early expansion of an intracerebral hemorrhage (ICH-Ex). Dynamic-susceptibility-contrast magnetic resonance imaging (DSC-MRI) can track the real-time leaking of contrast agents. It may be able to indicate active bleeding, like a CTA-spot. Materials and Methods: From September 2014 to February 2017, we did non-contrast CT, CTA, and DSC-MRI examinations of seven patients with acute ICH. We investigated the time from symptom onset to the first contrast-enhanced imaging. We evaluated the time course of the contrast leak within the ICH at the source image of the DSC-MRI and the volume change of ICH between non-contrast CT and DSC-MRI. We compared the number of slices showing CTA-spots and DSC-MRI leaks. Results: The CTA-spot and DSC-MRI leak-sign were present in four patients, and two patients among those showed ICH-Ex. The time from the symptom onset to CTA or DSC-MRI was shorter for those with a DSC-MRI leak or CTA-spot than for three patients without either (70-130 minutes vs. 135-270 minutes). The leak-sign began earlier, lasted longer, and spread to more slices in the patients with ICH-Ex than in those without ICH-Ex. The number of slices of the DSC-MRI leak and the number of the CTA-spot were well correlated. Conclusion: DSC-MRI can demonstrate the leakage of GBCA within hyperacute ICH, showing the good contrast between hematoma and contrast. The DSC-MRI leakage sign could be related to the hematoma expansion in patients with ICH.

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

Evaluation on Protrusion of the Imaginary Prostate Volume Using Three-Dimensional Volume Rendering (3차원 볼륨 렌더링을 이용한 가상 돌출형 전립선 부피 평가)

  • Seoung, Youl-Hun;Joo, Yong-Hyun;Rhim, Jae-Dong;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.208-215
    • /
    • 2009
  • This study is to compare the accuracy of evaluation regarding the volume of the prostate, which three-dimensional volume rendering was produced the shape of protrusion, by measuring two kinds of craniocaudal length from the top of the protrusion and from the exclusion of the protrusion as the starting points. For the imaginary protrusion prostate models, total of 10 models were roughly made by using devils-tongue jelly and changing each of the 10 ml of capacity from 10 ml to 100 ml. For the protrusion prostate models aimed at estimating the real volume, through 64 cannel computed tomography (CT) and 3.0 tesla magnetic resonance image (MRI) were conducted by planimetry technique from three-dimensional volume rendering. And then we performed to evaluate on significance of these volumes by wilcoxon signed rank test. Also the obtained volumes data by ellipsoid volume formula were measured the volume of protrusion prostate models two times with each method using the two kinds of craniocaudal length from top of the protrusion and from exclusion of the protrusion as the starting points. Finally, the significance of differences using wilcoxon signed rank test was evaluated between the real volume by planimetry technique and the measured volume by ellipsoid volume formula from three-dimensional volume rendering. The average of the protrusion length on the models was $0.90{\pm}0.18\;mm$ in CT and was $0.75{\pm}0.11\;mm$ in MRI. There were not statistically significant difference between MRI and CT from the volume of protrusion prostate models (p=0.414). In MRI (p=0.139) and CT (p=0.057), there were not statistically significant difference between the real volume by planimetry technique and the measured volume by ellipsoid volume from exclusion of the protrusion as the starting points. While, there were statistically significant difference between the real volume by planimetry technique and the measured volume by ellipsoid volume from top of the protrusion as the starting points in MRI (p=0.005) and CT (p=0.005). For the accurate measurement of the protrusion prostate models, the craniocaudal length of the prostate should be measured from the exclusion of the protrusion as the starting points.

  • PDF

Role of MRI and Plain Radiograph to Diagnose Fibrous Dysplasia Mimicking Metastasis on PET/CT in a Patient with Breast Cancer (유방암환자의 양전자방출단층촬영술에서 암 전이로 오인된 섬유형성이상 진단의 자기공명영상과 단순촬영의 역할)

  • Cho, Song-Mee;Jee, Won-Hee;Yoo, Ie-Ryung;Lee, Ah-Won;Chung, Yang-Guk
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.1
    • /
    • pp.47-50
    • /
    • 2010
  • Fibrous dysplasia is a common benign disorder of bone in which normal bone marrow is replaced with fibro-osseous tissue. As PET/CT is increasingly used for the staging of different malignant disease, incidentally found fibrous dysplasia with increased FDG uptake may mimic metastasis. We report on a 46-year-old woman with fibrous dysplasia who underwent PET/CT because of suspected recurrence of breast cancer and was misdiagnosed as a bony metastasis with a focal FDG uptake on left proximal femur. This lesion was interpreted as fibrous dysplasia based on MRI in addition to the plain radiographs. We conclude that MRI in addition to radiography may help to differentiate fibrous dysplasia mimicking metastasis on PET/CT in the patients with malignancy.

Usefulness of MRI 3D Image Reconstruction Techniques for the Diagnosis and Treatment of Femoral Acetabular Impingement Syndrome(Cam type) (대퇴 골두 충돌 증후군(Cam type)의 진단과 치료를 위한 자기공명 3D 영상 재구성 기법의 유용성)

  • Kwak, Yeong-Gon;Kim, Chong-Yeal;Cho, Yeong-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.313-321
    • /
    • 2015
  • To minimize CT examination for Hip FAI diagnosis and operation plan. also, whether the MRI 3D images can replace Hip Clock face image was evaluated when performing Hip FAI MRI by using additional 3D image. This study analyzed Hip MRI and 3D Hip CT images of 31 patients in this hospital. For the purpose of evaluating the images, one orthopedic surgeon and one radiology specialist reconstructed Clock face, at MR and CT modality, by superior 12 o'clock, labrum front 3 o'clock, and the other side 9 o'clock, centering on Hip joint articular transverse ligament 6 o'clock. Afterwards, by the Likert Scale 5 point scale (independent t-test p<0.005), this study evaluated the check-up of A. retinacular vessel, B. head neck junction at 11 o'clock, A. Epiphyseal line, B. Cam lesion at 12 o'clock, and Cam lesion, Posterior Cam lesion at 1,2,3 and 4 o'clock. As for the verification of reliability among observers, this study verified coincidence by Cohen's weighted Kappa verification. As a result of Likert scale for the purpose of qualitative evaluation about the image, 11 o'clock A. retinacular vessel MR average was $3.69{\pm}1.0$ and CT average was $2.8{\pm}0.78$. B. head neck juncton didn't have a difference between two observers (p <0.416). 12 o'clock A. Epiphyseal line MR average was $3.54{\pm}1.00$ and CT average was $4.5{\pm}0.62$(p<0.000). B. Cam lesion didn't have a difference between two observers (p <0.532). 1,2,3,4 Cam lesion and Posterior Cam lesion were not statistically significant (p <0.656, p <0.658). As a result of weighted Kappa verification, 11 o'clock A.retinacular vessel CT K value was 0.663 and the lowest conformity. As a result of coincidence evaluation on respective item, a very high result was drawn, and two observers showed high reliability.

Rapid Prototyping을 이용한 임플란트 생성

  • 방철배;김영호;강석호
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1997.10a
    • /
    • pp.37-40
    • /
    • 1997
  • RP(Rapid Prototyping) 기술은 점점 그 활용범위를 넓혀가는 추세이며, 의료분야에서도 임플란트의 제작등에 RP 기술의 도입이 시도되고 있다. 뼈나 치아 등의 인체부속물들은 속성상 직접 그 형태를 파악하기가 힘들고, 따라서 그 대체물인 임플란트의 제작을 위해 MRI나 CT등의 장비가 사용되고 있다. 의료분야에까지 이르는 RP의 활발한 활용에도 불구하고, 아직 국내에서는 RP에 대한 인식이 부족하고 그 활용에 대한 연구가 거의 없는 상황이다. 본 논문은 MRI, CT등의 2차원 평면데이터로부터 직접 RP 기계의 표준입력화일인 STL 파일을 생성시키기 위한 방법을 제시한다. 그리고 MRI로 스캐닝된 사람의 머리뼈 형상을 삼각메쉬 형태의 STL 파일로 변화하여 RP 기계를 통한 실물 모형 제작이 가능하도록 한 예를 설명하였다.

  • PDF