• Title/Summary/Keyword: CT, MRI

Search Result 899, Processing Time 0.028 seconds

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Development of Next Medical Imaging System beyond MRI (POST MRI 시대를 위한 3차원 차세대 의료영상기술 개발)

  • Hong, H.B.;Shin, S.W.;Park, J.H.
    • Electronics and Telecommunications Trends
    • /
    • v.29 no.5
    • /
    • pp.96-104
    • /
    • 2014
  • 1895년 독일 과학자 Wilhelm Roentgen 박사가 X-ray를 발견하고 미국의 Herman Carr가 MRI(Magnetic Resonance Imaging)의 기본 원리를 개발하여 발표한 이후 전자기장을 이용한 비침습적 의료영상 이미지 시스템은 놀라운 발전을 계속하여 왔다. 하지만, X-ray, CT(Computed Tomography), PET(Positron Emission Tomography)의 경우는 방사능의 사용과 조영제의 독성이라는 문제로 인하여 안전성에 대한 계속적인 문제를 야기해왔고 상대적으로 안전성이 입증된 MRI의 경우는 장비 자체 및 운용비가 일반화되기에는 고가여서 우리나라를 포함한 선진국에서도 아주 제한적으로 운영되고 있는 실정이다. 따라서, 세계적으로도 이러한 문제를 해결하기 위하여 안전하면서도 상대적으로 저렴한 비용으로 운용이 가능한 의료영상장비를 개발하기 위하여 많은 노력들이 경주되고 있어 관련 연구동향 및 산업화 동향을 소개하고자 한다.

  • PDF

Consideration of Imaging Studies for Degenerative Spine Disease (퇴행성 요추질환 영상의 고찰)

  • Sin, Jung-Sub;Kim, Jae-Hun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.1
    • /
    • pp.93-99
    • /
    • 2007
  • Purpose : The aim of this study is to consider degenerative spine disease theoretically and compare plain radiography which is a basic study for low back pain with MRI in cases of degenerative lumbar spine disease to find out whether the abnormalities agree with each other. Methods : In 4 cases of lumbar degenerative disease, we studied the relation of the abnormalities such as disc space narrowing, spinal space narrowing, loss of lordosis and osteophytes on plain radiography with those on MRI of HIVD, spinal stenosis and spondylolisthesis. Results : Many abnormalities such as disc space narrowing, spinal space narrowing, loss of lordosis, osteophytes and change of cortex & bone marrow on plain radiography suggest HIVD, spinal stenosis, spondylolysis or spondylolisthesis on MRI. Conclusion : For low back pain patients, plain radiography is a basic study in diagnosis of HIVD, spinal stenosis, spondylolysis or spondylolisthesis but MRI or CT scan is necessary to develop(build) a treatment plan like an operation.

  • PDF

Construction of 3D Geometric Surface Model from Laminated CT Images for the Pubis (치골 부위의 CT 적층 영상을 활용한 3D 기하학적 곡면 모델로의 가공)

  • Hwang, Ho-Jin;Mun, Du-Hwan;Hwang, Jin-Sang
    • Korean Journal of Computational Design and Engineering
    • /
    • v.15 no.3
    • /
    • pp.234-242
    • /
    • 2010
  • 3D CAD technology has been extended to a medical area including dental clinic beyond industrial design. The 2D images obtained by CT(Computerized Tomography) and MRI(Magnetic Resonance Imaging) are not intuitive, and thus the volume rendering technique, which transforms 2D data into 3D anatomic information, has been in practical use. This paper has focused on a method and its implementation for forming 3D geometric surface model from laminated CT images of the pubis. The implemented system could support a dental clinic to observe and examine the status of a patient's pubis before implant surgery. The supplement of 3D implant model would help dental surgeons settle operation plans more safely and confidently. It also would be utilized with teaching materials for a practice and training.

Unusual Brain Computed Tomography Artifact in Cerebellum Mimicking Hemorrhage: A Case Report (뇌 CT에서 출혈로 오인된 소뇌의 허상: 증례보고)

  • Lee, Jihun;Eom, Ki Seong;Kim, Tae-Young
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.195-197
    • /
    • 2015
  • Artifacts can seriously degrade the quality of computed tomography (CT) images, sometimes to the point of making them diagnostically unusable. Here, we report an unusual CT artifact that could have resulted in the misdiagnosis of a hyperdense hemorrhagic lesion in a 55-year-old man. The author recommend that when hemorrhagic lesion in posterior fossa is suggested on CT, the physician should carefully consider all patient-related clinical data prior to considering surgical intervention or a biopsy. Cranial magnetic resonance imaging (MRI) can help in preventing the misdiagnosis as hemorrhage of CT scan.

  • PDF

Modular Fasciitis Mimicking Malignant Tumor on $^{18}F$-FDG PET/CT ($^{18}F$-FDG PET/CT 영상에서 악성종양으로 오인되었던 결절성 근막염)

  • Lee, Seok-Mo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.263-265
    • /
    • 2005
  • A 25 years old male patient with Hodgkin's disease, considered as complete remission, underwent $^{18}F$-FDG whole body PET/CT. $^{18}F$-FDG whule body PET/CT showed unexpected hypermetabolic nodule in left quadratus femoris muscle suggesting local recurrence. Subsequent MRI also revealed well-enhancing nodular lesion with intermediate and high signal intensity on T1WI and T2WI, respectively. The lesion was confirmed as nodular fasciitis by pathologic examination of the excited specimen.