The Strategy for Intelligent Integrated Instrumentation and Control System Development

  • Kwon, Kee-Choon;Ham, Chang-Shik
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.153-158
    • /
    • 1995
  • All of the nuclear power plants in Korea we operating with analog instrumentation and control (I&C) equipment which are increasingly faced with frequent troubles, obsolescence and high maintenance expenses. Electrical and computer technology has improved rapidly in recent years and has been applied to other industries. So it is strongly recommended we adopt modern digital and computer technology to improve plant safety and availability. The advanced I&C system, namely, Integrated Intelligent Instrumentation and Control System (I$^3$CS) will be developed for beyond the next generation nuclear power plant. I$^3$CS consists of three major parts, the advanced compact workstation, distributed digital control and protection system including Automatic Start-up/shutdown Intelligent Control System (ASICS) and the computer-based alarm processing and operator support system, namely, Diagnosis, Response, and operator Aid Management System (DREAMS).

  • PDF

이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발 (Development of Measurement System for Industrial Transportable Gamma Ray CT)

  • 김종범;정성희;문진호
    • 방사선산업학회지
    • /
    • 제6권3호
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

KSLV-I 상단부 시험장비(UTE) 설계 및 개발 (Development of Test Equipment for KSLV-I Upper Stage)

  • 김광수;이수진;정의승;박정주
    • 항공우주기술
    • /
    • 제6권2호
    • /
    • pp.171-179
    • /
    • 2007
  • 상단부 시험장비(이하: UTE)는 KSLV-I 2단과 UMB 인터페이스를 통해 2단에 탑재된 전기/전자 서브시스템에 외부전원을 공급하고 Discrete/Analog/Serial 명령 출력 및 데이터 수신 등의 기능을 구현한 시스템으로 KSLV-I 상단부 시스템의 시스템 레벨 기능시험 수행이 주목적이라 할 수 있는 시스템이다. UTE는 PXI 제어시스템 및 전원공급기, 터미널 블록, 커넥터 패널, 내부 하니스 등의 H/W와 사용자 event에 따른 Discrete/Analog I/O 제어, PDU RS-422 통신제어, 전원공급장치 GPIB 제어 및 UTE 원격제어와 같은 S/W로 구성된다. 본 논문에서는 KSLV-I 상단부 UTE의 설계 및 개발에 관해 기술한다.

  • PDF

A TiO2-Coated Reflective Layer Enhances the Sensitivity of a CsI:Tl Scintillator for X-ray Imaging Sensors

  • Kim, Youngju;Kim, Byoungwook;Kwon, Youngman;Kim, Jongyul;Kim, MyungSoo;Cho, Gyuseong;Jun, Hong Young;Thap, Tharoeun;Lee, Jinseok;Yoon, Kwon-Ha
    • Journal of the Optical Society of Korea
    • /
    • 제18권3호
    • /
    • pp.256-260
    • /
    • 2014
  • Columnar-structured cesium iodide (CsI) scintillators doped with thallium (Tl) are frequently used as x-ray converters in medical and industrial imaging. In this study we investigated the imaging characteristics of CsI:Tl films with various reflective layers-aluminum (Al), chromium (Cr), and titanium dioxide ($TiO_2$) powder-coated on glass substrates. We used two effusion-cell sources in a thermal evaporator system to fabricate CsI:Tl films on substrates. The scintillators were observed via scanning electron microscopy (SEM), and scintillation characteristics were evaluated on the basis of the emission spectrum, light output, light response to x-ray dose, modulation transfer function (MTF), and x-ray images. Compared to control films without a reflective layer, CsI:Tl films with reflective layers showed better sensitivity and light collection efficiency, and the film with a $TiO_2$ reflective layer showed the best properties.

Airborne HPGe spectrometer for monitoring of air dose rates and surface activities

  • Marcel Ohera;Lubomir Gryc;Irena Cespirova;Jan Helebrant;Lukas Skala
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4039-4047
    • /
    • 2023
  • This contribution describes the application of HPGe detector for the airborne quantitative analysis. The hardware of the airborne HPGe system was designed from the commercial components with only exception of the newly designed AirHPGeSpec special software to control, measure and process the data. The system was calibrated for the local air kerma rates measured on helicopter board and its conversion to the air kerma rates at 1 m above the ground was proposed. Two examples of the air kerma rates measured over the former uranium mining areas are presented and compared with the results of other airborne system on the board. This airborne HPGe system could be also used for measuring the surface activities in a radiation event. The nuclides of 131I, 132Te - 132I, 133I, 134I, 135I, 137Cs, 134Cs, 88Rb and 103Ru were selected from possible nuclear power plant emergency scenarios. The Monte Carlo simulation was used to calculate HPGe detector efficiencies for the flight altitudes from 25 to 300 m for the energies from 300 keV to 3 MeV of the nuclides in question. Also, the detection limits according to the Currie method as well as ISO 11929-2010 for selected nuclides are presented.

RF와 PLC를 이용한 실시간 선박용 물탱크 무선 제어 시스템 설계 (Design of the Real-time Water Tank Wireless Control System in a Ship Using the RF and PLC)

  • 박옥득;이상훈;김현수;;;김한실;차창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.288-290
    • /
    • 2006
  • This paper presents the real-time water tank wireless control in a ship using duplex RF modules and PLC(Programmable logic Controller). The purpose of this paper is developing HMI(Human Machine Interface) for automation equipments. The system can low a cost because long wires are no more used. Analog signals of the water gauge and flow meter are changed to discrete signals by the micro-processor. The PLC checks the volume of water and runs On or Off of the valve and pump. Duplex RF modules send and receive data between the water tank and control room. Everywhere the Internet is used, operators are able to check the status of the system by the web-server.

  • PDF

소동물 영상화 및 환경 방사선 검출을 위한 감마카메라 개발 (Development of Gamma Camera System for Small Animal Imaging and Environmental Radiation Detection)

  • 백철하
    • 한국콘텐츠학회논문지
    • /
    • 제14권2호
    • /
    • pp.475-481
    • /
    • 2014
  • 이 연구의 목적은 감마선 검출 시스템을 개발하여 평행구멍형 조준기와 바늘구멍 조준기를 이용하여, 각각 소동물용 감마영상 획득과 환경 방사선 검출 영상을 획득하는 것이다. 본 연구에서는 크기가 $50{\times}50mm$ 이며, 6 mm 두께의 CsI(Tl) 섬광체와 $50{\times}50mm$ 크기의 Hamamatsu H8500C 위치민감형 광전자증배관, 저항분배회로, 전치증폭기, 성형증폭기, NIM 모듈 및 아날로그 디지털 변환기로 구성된 감마카메라를 개발하였다. 또한. 바늘구멍 감마카메라와 전하결합소자 카메라를 결합하여 환경모니터링에 적용할 수 있는 장비를 개발하였다. 본 연구 결과는 평행 구멍형 조준기와 바늘구멍 조준기를 이용한 감마카메라를 각각 소동물용 감마영상 획득과 환경방사선 측정에 적용 할 수 있음을 보여주었다. 이 시스템은 소 동물전용 감마카메라와 환경방사선 측정 시스템으로 활용 될 수 있을 것이다.

주파수 천이를 이용한 광무선 시스템에서 EOM의 바이어스 방식에 따른 광링크 성능 분석 (Optic Link Performances on EOM′s Biasing in Fiber-radio System)

  • 오세혁;양훈기;최영완
    • 대한전자공학회논문지SD
    • /
    • 제38권2호
    • /
    • pp.128-136
    • /
    • 2001
  • 본 논문은 주파수 천이를 적용시킨 광무선(fiber-radio)시스템의 광링크부에 대한 성능분석을 한다. 제시된 광링크부는 CS(control station)에서 얻어진 밀리미터파 대역 광파일럿톤(optical pilot tone)이 하향링크뿐 아니라 상향링크에도 공급되도록 하여 BS(base station)의 구조를 간단히 하였다. 광파일럿톤을 얻기 위해 CS의 EOM(electro-optic modulator)을 MAB(maximum bias), MIB(minimum bias), QB(quadrature bias)로 바이어스를 달리할 수 있으며 각각의 경우에 따라 링크의 성능을 분석한다. 분석은 레이저 광원의 전력이 일정한 경우와 PD(photo detector)에 수신되는 광 DC 전력이 일정한 경우에 대해서 행하여지며 각 경우에 대해서 최적의 하향링크 CNR 및 상향링크 SFDR(spurious free dynamic range)을 얻기 위해 효과적인 바이어스 방식을 제시한다

  • PDF

Negative ion beam sputter 법으로 증착한 DLC 박막의 특성 (I) (Properties of Diamond-like Carbon(DLC) Thin Films deposited by Negative Ion Beam Sputter (I))

  • 김대연;강계원;최병호
    • 한국재료학회지
    • /
    • 제10권7호
    • /
    • pp.459-463
    • /
    • 2000
  • 순수한 동적 결합반응이고 전하 누적이 없는 이온 임플란테이션, 새로운 재료 개발 등에 음이온을 직접 사용하는 새로운 연구가 진행되고 있으며, 이러한 관점에서 새로운 고체상의 Cs이온 법이 실험실 규모로 연구되고 있다. 본 논문에서는 음이온 Cs gun으로 DLC 박막을 실리콘 위에 제조하였다. 이 시스템은 가스가 필요없으므로, 고 진공에서 증착이 일어난다. C(sup)-빔 에너지는 80~150eV 사이에서 조절이 우수하였다. Raman 분석결과 박막의 DLC 지수, 즉$sp^3$비율은 이온 에너지 증가에 따라 증가하였으며, 미소 경도값 또한 7에서 14GPa로 증가하였다. DLC박막의 표면 평균거칠기(Ra)는 ~1$\AA$정도로 아주 매끈하였으며, 불순물이 내재되지 않는 박막을 얻을 수 있었다.

  • PDF

Distributed control system architecture for deep submergence rescue vehicles

  • Sun, Yushan;Ran, Xiangrui;Zhang, Guocheng;Wu, Fanyu;Du, Chengrong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권1호
    • /
    • pp.274-284
    • /
    • 2019
  • The control architectures of Chuan Suo (CS) deep submergence rescue vehicle are introduced. The hardware and software architectures are also discussed. The hardware part adopts a distributed control system composed of surface and underwater nodes. A computer is used as a surface control machine. Underwater equipment is based on a multi-board-embedded industrial computer with PC104 BUS, which contains IO, A/D, D/A, eight-channel serial, and power boards. The hardware and software parts complete data transmission through optical fibers. The software part involves an IPC of embedded Vxworks real-time operating system, upon which the operation of I/O, A/D, and D/A boards and serial ports is based on; this setup improves the real-time manipulation. The information flow is controlled by the software part, and the thrust distribution is introduced. A submergence vehicle heeling control method based on ballast water tank regulation is introduced to meet the special heeling requirements of the submergence rescue vehicle during docking. Finally, the feasibility and reliability of the entire system are verified by a pool test.