• Title/Summary/Keyword: CRT(cathode ray tube)

Search Result 64, Processing Time 0.027 seconds

Characterization of Compensation Film for LCD by Polarization Measurement (LCD용 시야각 보상필름의 편광 특성 측정)

  • 강재경;황효창;권진혁
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.208-209
    • /
    • 2000
  • 기존의 CRT(cathode-ray tube)를 사용한 TV, 모니터와 같은 디스플레이는 부피가 커서 공간을 많이 차지하고 휴대품으로는 거의 사용이 불가능하였다. 그러나, 평판 디스플레이의 하나인 LCD(liquid crystal display)는 소비 전력이 작고 부피가 작아서 게임기, Note-book PC와 같은 휴대용으로는 물론 PC용 모니터와 같은 사무용 디스플레이, TV와 같은 가정용 디스플레이를 대체해 나가고 있다. (중략)

  • PDF

Development of Statistical Analyzing Tool and System of Automatic Magnetizer (착자 자동화 시스템 및 통계분석 툴 개발)

  • Lee, Cheon-Hui;Ha, Gi-Jong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.4
    • /
    • pp.1014-1025
    • /
    • 1996
  • The magnetizer that is magnetizing the magnet which is used for RGB (Red Green Blue) control of CRT(Cath-ode-Ray Tube)and the magnet inspection unit which is used for test the state of magnetizing have been imported by magnet manufactures up to now. They are operation by manual now, so that they are needed lots of time and have an increase in probability of malefunction by operator. In this study, we have developed a united system from the magnet production process to inspection ork to automaized a entire progress. Therefor, as we are testing the status of every work and analyzing exactly the distribution in quality with this system, we have known that the reliability of magnetization and magnetized status test has not only increased, but the rate of inferior quality almost not generated.

  • PDF

A Three-dimensional Magnetic Field Mapping System for Deflection Yoke of Cathode-Ray Tube

  • Park, K.H.;Yoon, M.;Kim, D.E.;Lee, S.M.;Joo, H.D.;Lee, S.D.;Yang, W.Y.
    • Journal of Information Display
    • /
    • v.3 no.4
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we introduce an efficient three-dimensional magnetic field mapping system for a Deflection Yoke (DY) in Cathode-Ray Tube (CRT). A three-axis Hall probe mounted in a small cylindrical bar and three-stepping motors placed in a non-magnetic frame were utilized for the mapping. Prior to the mapping starts, the inner contour of DY was measured by a laser sensor to make a look-up table for inner shape of DY. Three-axis magnetic fields are then digitized by a three-dimensional Hall probe. The results of the mapping can be transformed into various output formats such as multi pole harmonics of magnetic fields. Field shape in one, two and three- dimensional spaces can also be displayed. In this paper, we present the features of this mapping device and some analysis results.

Square Wave Voltammetry in Cathode Ray Tube Glass Melt Containing Different Polyvalent Ions (서로 다른 다가이온을 함유한 음극선관 전면유리 용융체의 Square Wave Voltammetry)

  • Kim, Ki-Dong;Kim, Hyo-Kwang;Kim, Young-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.6 s.301
    • /
    • pp.297-302
    • /
    • 2007
  • With aids of square wave voltammetry (SWV) the redox behavior for various combination of polyvalent ions (Sb+Fe, Sb+Zn, Sb+Ce+Ti+Zn) was investigated in alkali-alkaline earth-silica CRT (Cathode Ray Tube) glass melts. The current-potential curve so called voltammogram was produced at temperature range of 1400 to $1000^{\circ}C$ under the scanned potential between 0 and -800 mV at 100 Hz. In the case of the Sb+Fe and Sb+Zn doped melts, peak for $Sb^{3+}/Sb^0$ shown voltammogram was shifted to negative direction comparing to the only Sb doped melts. However, according to voltammogram of Sb+Ce+Ti+Zn doped melt, Ti and Ce except Zn had hardly any influence on the redox reaction of Sb. Based on the temperature dependence of the peak potential, standard enthalpy (${\Delta}H^0$) and standard entropy (${\Delta}S^0$) for the reduction of $Fe^{3+}$ to $Fe^{2+}$, $Sb^{3+}$ to $Sb^0$, $Zn^{2+}$ to $Zn^0$ and $Ti^{2+}$ to $Ti^0$ in each polyvalent ion combination of CRT glass melts were calculated.

Exposure Filter Design for Wide Angle CRT (CRT 편향각 증가를 위한 노광필터 설계)

  • Kim, Ryo-Hyang;Lee, Tae-Yong;Choi, Sie-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.9
    • /
    • pp.14-20
    • /
    • 2008
  • In recent days, a wide angle for slim depth in CRT(Cathode ray tube) is required to meet other rapidly growing slim FPD such as LCD and PDP. However, in making the CRT with a wide angle screen, problems, such as a difficulty in forming black matrix, and excessive formation of black matrix, can be occurred. In this work, we designed a new exposure filter systm to avoid these problems for a wide angle CRT. We changed the design concept from a filter-to-Panel method to a Panel-to-fater control method, which can control the Black Matrix to easily satisfy the user's request. This study suggests new filter design method for a wide angle CRT which has good screen qualify.

Behavior of Oxygen Equilibrium Pressure in CRT Glass Melts doped with Sb and Ce ions from the Viewpoint of Fining

  • Kim, Ki-Dong;Kim, Hyo-Kwang;Kim, Jun-Hong
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.8
    • /
    • pp.419-423
    • /
    • 2007
  • The behavior of oxygen gas participating in fining was observed in CRT (Cathode Ray Tube) glass melts doped with $Sb_2O_5\;or\;CeO_2$ by means of a yttria-stabilized zirconia (YSZ) electrode. The temperature dependence of the oxygen equilibrium pressure ($P_{o2}$) or the activity in both melts showed typical behavior corresponding to a theoretical redox reaction. In other words, the $P_{o2}$ value of melts with $CeO_2$ was lower than that of melts with $Sb_2O_5$ above $1250^{\circ}C$. The result implies that $Sb_2O_5$, is more efficient as a fining agent compared to $CeO_2$. On the other hand, melts from a batch containing $Sb_2O_5\;and\;KNO_3$ showed much higher $P_{o2}$ values compared to melts without $KNO_3$ above $1350^{\circ}C$. It is suggested that the addition of $KNO_3$ to CRT glass batch contributes partly to the first fining of the melts.

Shape Optimization of a CRT based on Response Surface and Kriging Metamodels (반응표면과 크리깅메타모델을 이용한 CRT 형상최적설계)

  • Lee, Tae-Hee;Lee, Chang-Jin;Lee, Kwang-Ki
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.3
    • /
    • pp.381-386
    • /
    • 2003
  • Gradually engineering designers are determined based on computer simulations. Modeling of the computer simulation however is too expensive and time consuming in a complicate system. Thus, designers often use approximation models called metamodels, which represent approximately the relations between design and response variables. There arc general metamodels such as response surface model and kriging metamodel. Response surface model is easy to obtain and provides explicit function. but it is not suitable for highly nonlinear and large scaled problems. For complicate case, we may use kriging model that employs an interpolation scheme developed in the fields of spatial statistics and geostatistics. This class of into interpolating model has flexibility to model response data with multiple local extreme. In this study. metamodeling techniques are adopted to carry out the shape optimization of a funnel of Cathode Ray Tube. which finds the shape minimizing the local maximum principal stress Optimum designs using two metamodels are compared and proper metamodel is recommended based on this research.

TOPSIS-Based Multi-Objective Shape Optimization for a CRT Funnel (TOPSIS 를 적용한 CRT 후면유리의 다중목적 형상최적설계)

  • Lee, Kwang-Ki;Han, Jeong-Woo;Han, Seung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.7
    • /
    • pp.729-736
    • /
    • 2011
  • The technique for order preference by similarity to ideal solution (TOPSIS) is regarded as a classical method of multiple attribute decision making (MADM), often used to solve various decision-making or selection problems. It is based on the concept that the chosen alternative should have the shortest distance from the positive ideal solution and the farthest distance from the negative ideal solution. The TOPSIS can be applied to a design process for carrying out multi-objective shape optimization wherein the best and worst alternatives are to be decided. In this paper, multi-objective shape optimization using the TOPSIS and Rational Bezier curve was applied to the funnel of a cathode-ray tube (CRT). In order to minimize the weight and first principal stress, a new multi-objective shape optimization methodology is proposed, wherein the relative-closeness coefficients of the TOPSIS are defined as the performance indices of a multi-objective function and evaluated by response surface models. This methodology enables the designer to decide on the best solution from a number of design specification groups by examining the various conflicts between the weight and the first principal stress.

Digital Video Warping for Convergence of Projection TV Receivers (프로젝션 TV에서의 광학적 왜곡 보정 알고리즘)

  • Hwang, Kyu-Young;Shin, Hyun-Chool;Woong Seo;Song, Woo-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.535-538
    • /
    • 2001
  • In this paper, we present a novel method to solve the inevitable RGB beam mismatch problem in projection TV receivers. Conventional methods solve the mismatch problem by directly controlling the cathode ray tube (CRT) using the convergence yoke (CY). Unlike conventional methods, the proposed method is based on digital video processing using image warping techniques. Firstly RGB beam projection paths are mathematically modeled. Then based on the modeling, the input video signal to CRT is prewarped so that RGB beams are landed at the same point on the screen. Since the proposed method is based on a digital video processing instead of using CY, it can outperform the conventional method in terms of quality and cost. The experimental results with a real 60´projection TV demonstrate that the proposed method indeed produces converged images on the projection TV screen.

  • PDF

The Development of PHosphor Screen Formation For Oscilloscope Using Screen Printing Method (스크린 인쇄법을 이용한 오실로스코프용 형광막 제조 기술 개발)

  • Lee, Mi-Young;Kim, Young-Bea;Nam, Su-Yong
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.22 no.1
    • /
    • pp.53-64
    • /
    • 2004
  • The CRT(cathode ray tube) in oscilloscope consists of an electron gun, horizontal vertical deflection system and a phosphor screen. When the electron beam strikes the phosphor screen, the phosphor generates light. The phosphor screen has formed by CRT precipitation method. But, this method has some defects that are complex process, low yield, much consumption of raw-material, dirty working environment, waste problem, require of high cost. Moreover phosphor for oscilloscope used at present has been imported from Japan. Therefore developments of new phosphor and new method(the screen printing) top form phosphor screen for oscilloscope are required to improve these matters. This study was developed novel method(the screen printing) to form the phosphor screen for oscilloscope used new phosphor. This screen printing method has advantages of simple process, high yield, clean working environment, saving raw material and running-cost.

  • PDF