• Title/Summary/Keyword: CRM.

Search Result 1,179, Processing Time 0.025 seconds

Cashew reject meal in diets of laying chickens: nutritional and economic suitability

  • Akande, Taiwo O;Akinwumi, Akinyinka O;Abegunde, Taye O
    • Journal of Animal Science and Technology
    • /
    • v.57 no.5
    • /
    • pp.17.1-17.6
    • /
    • 2015
  • The present study investigated the nutritional and economic suitability of cashew reject meal (full fat and defatted) as replacement for groundnut cake (GNC) in the diets of laying chickens. A total of eighty four brown shavers at 25 weeks of age were randomly allotted into seven dietary treatments each containing 6 replicates of 2 birds each. The seven diets prepared included diet 1, a control with GNC at $220gkg^{-1}$ as main protein source in the diet. Diets 2, 3 and 4 consist of gradual replacement of GNC with defatted cashew reject meal (DCRM) at 50%, 75% and 100% on weight for weight basis respectively while diets 5, 6 and 7 consist of gradual inclusion of full fat cashew reject meal (FCRM) to replace 25%, 35% and 50% of GNC protein respectively. Each group was allotted a diet in a completely randomized design in a study that lasted eight weeks during which records of the chemical constituent of the test ingredients, performance characteristics, egg quality traits and economic indicators were measured. Results showed that the crude protein were 22.10 and 35.4% for FCRM and DCRM respectively. Gross energy of DCRM was 5035 kcal/kg compared to GNC, 4752 kcal/kg. Result of aflatoxin $B_1$ revealed moderate level between 10 and $17{\mu}g/Kg$ in DCRM and GNC samples respectively. Birds on control gained 10 g, while those on DCRM and FCRM gained about 35 g and 120 g respectively. Feed intake declined (P < 0.05) with increased level of FCRM. Hen day production was highest in birds fed DCRM, followed by control and lowest value (P < 0.05) was recorded for FCRM. No significant change (P > 0.05) was observed for egg weight and shell thickness. Fat deposition and cholesterol content increased (P > 0.05) with increasing level of FCRM. The cost of feed per kilogram decreased gradually with increased inclusion level of CRM. The prediction equation showed the relative worth of DCRM compared to GNC was 92.3% whereas the actual market price of GNC triples that of DCRM. It was recommended that GNC could be completely replaced by DCRM in layer's diets in regions where this by product is abundant. However, FCRM should be cautiously used in diets of laying chickens.

Scheduling System using CSP leer Effective Assignment of Repair Warrant Job (효율적인 A/S작업 배정을 위한 CSP기반의 스케줄링 시스템)

  • 심명수;조근식
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2000.11a
    • /
    • pp.247-256
    • /
    • 2000
  • 오늘날의 기업은 상품을 판매하는 것 뿐만 아니라 기업의 신용과 이미지를 위해 그 상품에 대한 사후처리(After Service) 업무에 많은 투자를 하고 있다. 이러한 양질의 사후서비스를 고객에게 공급하기 위해서는 많은 인력을 합리적으로 관리해야 하고 요청되는 고장수리 서비스 업무를 빠르게 해결하기 위해서는 업무를 인력들에게 합리적으로 배정을 하고 회사의 비용을 최소화하면서 정해진 시간에 요청된 작업을 처리하기 위해서는 인력들에게 작업을 배정하고 스케줄링하는 문제가 발생된다. 본 논문에서는 이러한 문제를 해결하기 위해 화학계기의 A/S 작업을 인력에게 합리적으로 배정하는 스케줄링 시스템에 관한 연구이다. 먼저 스케줄링 모델을 HP 사의 화학분석 및 시스템을 판매, 유지보수 해 주는 "영진과학(주)"회사의 작업 스케줄을 분석하여 필요한 도메인과 고객서비스전략과 인력관리전략에서 제약조건을 추출하였고 여기에 스케줄링 문제를 해결하기 위한 방법으로 제약만족문제(CSP) 해결기법인 도메인 여과기법을 적용하였다. 도메인 여과기법은 제약조건에 의해 변수가 갖는 도메인의 불필요한 부분을 여과하는 것으로 제약조건과 관련되어 있는 변수의 도메인이 축소되는 것이다. 또한, 스케줄링을 하는데에 있어서 비용적인 측면에서의 스케줄링방법과 고객 만족도에서의 스케줄링 방법을 비교하여 가장 이상적인 해를 찾는데 트래이드오프(Trade-off)를 이용하여 최적의 해를 구했으며 실험을 통해 인력에게 더욱 효율적으로 작업들을 배정 할 수 있었고 또한, 정해진 시간에 많은 작업을 처리 할 수 있었으며 작업을 처리하는데 있어 소요되는 비용을 감소하는 결과를 얻을 수 있었다. 검증하였다.를, 지지도(support), 신뢰도(confidence), 리프트(lift), 컨빅션(conviction)등의 관계를 통해 다양한 방법으로 모색해본다. 이 연구에서 제안하는 이러한 개념계층상의 흥미로운 부분의 탐색은, 전자 상거래에서의 CRM(Customer Relationship Management)나 틈새시장(niche market) 마케팅 등에 적용가능하리라 여겨진다.선의 효과가 나타났다. 표본기업들을 훈련과 시험용으로 구분하여 분석한 결과는 전체적으로 재무/비재무적 지표를 고려한 인공신경망기법의 예측적중률이 높은 것으로 나타났다. 즉, 로지스틱회귀 분석의 재무적 지표모형은 훈련, 시험용이 84.45%, 85.10%인 반면, 재무/비재무적 지표모형은 84.45%, 85.08%로서 거의 동일한 예측적중률을 가졌으나 인공신경망기법 분석에서는 재무적 지표모형이 92.23%, 85.10%인 반면, 재무/비재무적 지표모형에서는 91.12%, 88.06%로서 향상된 예측적중률을 나타내었다.ting LMS according to increasing the step-size parameter $\mu$ in the experimentally computed. learning curve. Also we find that convergence speed of proposed algorithm is increased by (B+1) time proportional to B which B is the number of recycled data buffer without complexity

  • PDF

Construction of Component Repository for Supporting the CBD Process (CBD 프로세스 지원을 위한 컴포넌트 저장소의 구축)

  • Cha, Jung-Eun;Kim, Hang-Kon
    • Journal of KIISE:Software and Applications
    • /
    • v.29 no.7
    • /
    • pp.476-486
    • /
    • 2002
  • CBD(Component Based Development) has become the best strategical method for the business application. Because CBD is a new development paradigm which makes it possible to assemble the software components for application, it copes with the rapid challenge of business process and meets the increasing requirements for productivity. Since the business process is rapidly changing, CBD technology is the promising way to solve the productivity. Especially, the repository is the most important part for the development, distribution and reuse of components. In component repository, we can store and manage the related work-products produced at each step of component development as well as component itself. In this paper, we suggested a practical approach for repository construction to support and realize the CBD process and developed the CRMS(Component Repository Management System) as implementation product of the proposed techniques. CRMS can manage a variety of component products based on component architecture, and help software developers to search a candidate component for their project and to understand a variety of information for the component. In the paper, a practical approach for component repository was suggested, and a supporting environment was constructed to make CBD to be working efficiently. We expect this work wall be valuable research for component repository and the entire supporting Component Based Development Process.

Multichannel Shopping and Customer Satisfaction: The Role of Shopping Experience and Customer-Firm Relationship Characteristics (다채널 쇼핑과 고객만족: 쇼핑경험과 고객-기업 관계특성의 역할)

  • Joo, Young-Hyuck
    • Journal of Distribution Research
    • /
    • v.15 no.4
    • /
    • pp.21-60
    • /
    • 2010
  • In recent retail environments, multichannel customer management increasingly has been considered a key element of successful CRM. Although customer's multichannel usage is believed to be potential cause of customer loyalty, the theoretical explanation about this causal relationship still remains unexamined and unanswered. In this paper, the authors present a systematic framework to test the postulated "multichannel usage-shopping experience-customer satisfaction" chain. To this end, we examine that the two core components of shopping experience(convenience and enjoyment) is a mediator of the direct causality of multichannel usage(based on both information search and product purchase stage) on customer satisfaction. Moreover, the authors examine that two types of customer-firm relationship characteristics(relationship age and purchase frequency) is a moderator of the multichannel usage-shopping experience relationship. Using integrating data with survey and customer database of multichannel retail company, the authors empirically test and substantiate shopping experience's mediating role in the multichannel usage-customer satisfaction relationship and customer-firm relationship characteristics' moderating role in the multichannel usage-customer experience relationship. These results suggest that multichannel retailers should deliver favorable shopping experience for building customer satisfaction and differentiate shopping experience according to customer-firm relationship characteristics.

  • PDF

Effect of Differences between Korean Ministry of Environment Standard and ISO Standard on Determination of Petroleum Hydrocarbon Content in Soil (토양오염공정시험기준과 국제표준간의 분석방법 차이가 유류 정량에 미치는 영향)

  • Jung, In-Ho;Lee, Goon-Taek;Lee, Won-Seok;Kim, Yong-Hoon;Kim, Bo-Hyun;Kim, Ji-In;Kim, Bo-Kyong
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.4
    • /
    • pp.63-72
    • /
    • 2012
  • The main objective of this study is to assess the compatibility between Korean ministry of environment (KME) standard and ISO (KS I ISO) standard for the determination of BTEX and TPH content in soil. We carried out comparison analysis for both methods using CRM and matrix spiked samples. In case of GC-MS analysis for BTEX, we got statistically (significance level: 0.05) the same results from KME standard (ES 07600.1) and ISO standard (KS I ISO 15009). However, it showed statistically (significance level: 0.05) different results when TPH was analyzed by KME standard (ES 07552.1) and ISO standard (KS I ISO 16703). To clarify the reason why both methods produced different results for TPH content, we also did some additional experiments in terms of differences in extraction, clean-up and target hydrocarbon range. Extraction with polar and non-polar compounds mixed solvent (acetone+n-heptane) of KS I ISO 16703 showed higher extraction efficiency than with only non polar solvent (dichloromethane) extraction of ES 07552.1 by about 9%. While column type clean-up of KS I ISO 16703 showed the reduction in TPH content between before and after clean-up, batch type of clean-up of ES 07552.1 did not show any changes in TPH content through clean-up process. The target hydrocarbon range of ES 07552.1 and KS I ISO 16703 is $C_8{\sim}C_{40}$ and $C_{10}{\sim}C_{40}$, respectively. From this point of view, kerosene and JP-8 contaminated soil showed higher RPD (relative producibility deviation) values between results by both method than that of lubricant or diesel contaminated soil. The higher content of hydrocarbon ($C_8{\sim}C_{10}$) in kerosene and JP-8 played an important role in increasing RPD values in addition to the effects caused by different solvents and clean-up method. Consequently, it was concluded that both methods (ES 07552.1 and KS I ISO 16703) were not compatible.

A Study on the Self-absorption Correction Method of HPGe Gamma Spectrocopy Analysis System Using Check Source (Check Source를 이용한 HPGe감마핵종분석시스템의 자체흡수 보정방법 연구)

  • Jeong-Soo, Park;Hyo-Jin, Lim;Hyun-Soo, Seo;Da-bin, Jang;Myoung-Joon, Kim;Sang-Bok, Lee;Sung-Min, Ahn
    • Journal of radiological science and technology
    • /
    • v.45 no.6
    • /
    • pp.523-529
    • /
    • 2022
  • Gamma spectroscopy analysis is widely used for radioactivity analysis, and various factors are required for radioactivity calculations. Among the factors, K3 for each sample significantly influences the results. The previous methods of correcting the self-absorption effect include a computational simulation method and a method that requires making a CRM(certified reference material) identical to the sample medium. However, the above methods have limitations when used in small institutions because they require specialized program utilization skills or high manufacturing costs and large facilities. The aim of this study is to develop a method that can be easily and rapidly applied to radioactivity analysis. After filling the beaker with water, we placed the radiation source in a uniform position and used the measured value as the benchmark. Next, a correction factor was derived based on the difference in the radiation source count of the benchmark and the identically measured sample. For the radiation source, Eu-152, which emits a broad range of energy within the measurement range of gamma rays, and Cs-134 and Cs-137, which are indicator nuclides in environmental radiation analysis, were used. The sample was selected within the density range of 0.26-2.11 g/cm3, and the correction factor was derived by calculating the count difference of each sample compared to the reference value of water. This study presents a faster and more convenient method than the existing research methods for determining the self-absorption effect correction, which has become increasingly necessary.

A simple method to determine lycopene in solid supplementary food preparations using saponification and liquid chromatography (비누화 및 액체크로마토그래프를 활용한 고상 건강기능식품 중 라이코펜 분석법 개발)

  • Young Min Kim;Ye Bin Shin;Min Kyeong Kwon;Jin Hwan Kim;Ji Seong Kim;Dong-Kyu Lee;Myung Joo Kang;Yong Seok Choi
    • Analytical Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.105-112
    • /
    • 2023
  • Lycopene, a carotenoid hydrocarbon is known to have effects on reducing cardiovascular risk factors, blood lipids, and blood pressure. Thus, a lot of supplementary foods with lycopene in several dosage forms like soft capsule filled with liquid and hard capsule filled with powder are available in a market. Recently, however, our research group found that the lycopene assay in Supplementary Food Code of South Korea is only valid for oily lycopene preparation. Thus, here, we developed a simple method to determine lycopene in solid preparations for Supplementary Food Code of South Korea using saponification and liquid chromatography with an absorbance detector. The method was validated following Ministry of Food and Drug Safety guidelines. All validation parameters observed in this study were within acceptable criteria of the guidelines (selectivity, linearity of r2 ≥ 0.991, lower limit of quantification of 0.0149 mg/mL, accuracy as recovery (R) between 92.70 and 97.18 %, repeatability as relative standard deviation (RSD) values of R between 0.85 and 1.59 %, and reproducibility as the RSD value of interlaboratory R of 3.70 %). Additionally, the practical sample applicability of the validated method was confirmed by accuracy between 98.81 and 101.59 % observed from its lycopene certified reference material (CRM) analyses. Therefore, the present method could contribute to fortify the supplementary food safety management system in South Korea.

Dead Layer Thickness and Geometry Optimization of HPGe Detector Based on Monte Carlo Simulation

  • Suah Yu;Na Hye Kwon;Young Jae Jang;Byungchae Lee;Jihyun Yu;Dong-Wook Kim;Gyu-Seok Cho;Kum-Bae Kim;Geun Beom Kim;Cheol Ha Baek;Sang Hyoun Choi
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.129-135
    • /
    • 2022
  • Purpose: A full-energy-peak (FEP) efficiency correction is required through a Monte Carlo simulation for accurate radioactivity measurement, considering the geometrical characteristics of the detector and the sample. However, a relative deviation (RD) occurs between the measurement and calculation efficiencies when modeling using the data provided by the manufacturers due to the randomly generated dead layer. This study aims to optimize the structure of the detector by determining the dead layer thickness based on Monte Carlo simulation. Methods: The high-purity germanium (HPGe) detector used in this study was a coaxial p-type GC2518 model, and a certified reference material (CRM) was used to measure the FEP efficiency. Using the MC N-Particle Transport Code (MCNP) code, the FEP efficiency was calculated by increasing the thickness of the outer and inner dead layer in proportion to the thickness of the electrode. Results: As the thickness of the outer and inner dead layer increased by 0.1 mm and 0.1 ㎛, the efficiency difference decreased by 2.43% on average up to 1.0 mm and 1.0 ㎛ and increased by 1.86% thereafter. Therefore, the structure of the detector was optimized by determining 1.0 mm and 1.0 ㎛ as thickness of the dead layer. Conclusions: The effect of the dead layer on the FEP efficiency was evaluated, and an excellent agreement between the measured and calculated efficiencies was confirmed with RDs of less than 4%. It suggests that the optimized HPGe detector can be used to measure the accurate radioactivity using in dismantling and disposing medical linear accelerators.

A study on quality assurance and evaluation of uncertainty for the analysis of natural gas (천연가스 분석의 불확도 평가 및 품질 보증을 위한 연구)

  • Woo, Jin-Chun;Kim, Young-Doo;Bae, Hyun-Kil;Lee, Kang-Jin;Her, Jae-Young
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.490-497
    • /
    • 2006
  • The sources of uncertainty in the analysis of liquified natural gas (LNG) process are evaluated. The uncertainty sources evaluated are the repeatability of measurement, non-linearity of GC, the uncertainty of standard gas used for calibration, difference of gas sampling and deviation after GC calibration and major revealed sources are the non-linearity of GC, the uncertainty of standard gas and the deviation after GC calibration. The determined values and uncertainties of methane and ethane as the major components are $90.0%mol/mol{\pm}1.9%$ (relative and 95% level of confidence) and $6.26%mol/mol{\pm}0.08$ (relative and 95% level of confidence), respectively. The contribution of uncertainty varies depending on the source of uncertainty and gas component. In the case of methane, non-linearity of GC, the uncertainty of standard gas and deviation after GC calibration contribute 0.28%, 0.25% and 0.24% of relative expanded uncertainty, respectively.

Determination of trace arsenic in seawater by flow injection-hydride generation inductively coupled plasma mass spectrometry (연속흐름주입-수소화물생성-유도결합플라스마 질량분석장치를 이용한 바닷물표준시료중의 극미량 비소분석방법의 확립)

  • Suh, Jung-Ki
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.316-325
    • /
    • 2008
  • An inductively coupled plasma mass spectrometry (ICP-MS) instrument equipped with flow injection-hydride generation system was used for the determination of trace arsenic in seawater sample. The accuracy in this method was verified by the analysis of certified reference materials (CRM) of seawater (CASS-4, NASS-5). The analytical results agreed with certified value within the range of uncertainty. The expanded uncertainties for CASS-4 and NASS-5 in this experiment were ranged from 6.2% to 6.8% obtained from repeated analyses of the CRMs (n=5). The detection limit of $As^+$ (m/z=74.9216) in this method was confirmed about 0.01 ug/kg. Linearity obtained from calibration curve of arsenic was excellent ($R^2=1$). The detection at $As^+$ (m/z=74.9216) and $AsO^+$ (m/z=90.9165) by using oxygen reaction gas in DRC mode was compared. Sensitivity at $AsO^+$ (m/z=90.9165) was decreased about 25-fold, but the analytical results are the same that at $As^+$ (m/z=74.9216).