• 제목/요약/키워드: CRM (certified reference material)

검색결과 59건 처리시간 0.021초

Determination of trace elements in food reference materials by instrumental neutron activation analysis

  • Cho, K.H.;Zeisler, R.;Park, K.W.
    • 분석과학
    • /
    • 제18권6호
    • /
    • pp.520-528
    • /
    • 2005
  • Two biological Certified Reference Materials (CRMs), KRISS 108-04-001 (oyster tissue) and 108-05-001 (water dropwort stem), were prepared by Korea Research Institute of Standards and Science (KRISS)during FY '01. The certified values of these materials had been determined by Isotope Dilution Mass Spectrometry (IDMS) for six elements (Cd, Cr, Cu, Fe, Pb and Zn). Additional analytical works are now progressing to certify the concentrations of a number of the environmental and nutrimental elements in these CRMs. The certified values in a CRM are usually determined by using a single primary method with confirmation by other method(s) or using two independent critically-evaluated methods. Instrumental Neutron Activation Analysis (INAA) plays an important role in the determination of certified values as it can eliminate the possibility of common error sources resulting from sample dissolution. In this study INAA procedure was used in determination of 23 elements in these two biological CRMs to acquire the concentration information and the results were compared with KRISS certified values.

인증표준물질(Certified reference materials, CRM)을 이용한 이옥신류(PCDDs/PCDFs) 측정의 정확도 평가 (Evaluation of accuracy for measurement of Dioxins (PCDDs/PCDFs) by using certified reference material (CRM))

  • 윤여영;박덕희;임영희;조혜성
    • 분석과학
    • /
    • 제22권5호
    • /
    • pp.376-385
    • /
    • 2009
  • 본 연구에서는 고농도 PCBs (Polychlorinated biphenyls)로 오염된 토양류 인증표준물질(Certified reference materials, CRM) 내에 존재하는 17종의 PCDDs/PCDFs를 분석하여 측정의 정확도를 평가하였다. 분석 방법은 2007년 환경부에서 고시한 비의도적 잔류성유기오염물질 공정시험방법을 토대로 하였으나 다층 실리카겔 컬럼과 알루미나 컬럼으로만 정제 시 방해 물질들이 충분히 제거되지 않아 활성탄 컬럼을 추가하여 정제하였다. 정확도의 평가 지표로서는 한국표준과학연구원(KRISS)에서 제시한 |En| 값을 사용하였으며 |En|값이 1이하인 경우 정량 결과를 '만족'으로 판정한다. 본 실험에서 DB-5MS컬럼과 SP-2331 컬럼을 병용하여 CRM을 분석한 결과 17종 2,3,7,8-치환이성체 모두 1 이하의 |En| 값을 얻었다. 또한 DB-5MS 컬럼에서 분리되지 않는 1,2,3,7,8-PeCDD와 3,3',4,4',5,5'-HxCB는 선택 이온비를 EPA1613 방법에서 제시한 M+2/M+4 대신 M/M+2로 변경하여 HRGC/HRMS 분석에서 구분이 가능하도록 하였다.

Accurate Measurement of Arsenic in Laver by Gravimetric Standard Addition Method Combined with High Resolution Inductively Coupled Plasma Mass Spectrometry

  • Lee, Kyoung-Seok;Kim, Hyeon-Ji;Yim, Yong-Hyeon;Kim, Jeongkwon;Hwang, Euijin
    • Mass Spectrometry Letters
    • /
    • 제5권2호
    • /
    • pp.57-61
    • /
    • 2014
  • A gravimetric standard addition method combined with internal standard calibration has been successfully developed for the accurate analysis of total arsenic in a laver candidate reference material. A model equation for the gravimetric standard addition approach using an internal standard was derived to determine arsenic content in samples. Handlings of samples, As standard and internal standard were carried out gravimetrically to avoid larger uncertainty and variability involved in the volumetric preparation. Germanium was selected as the internal standard because of its close mass to the arsenic to minimize mass-dependent bias in mass spectrometer. The ion signal ratios of $^{75}As^+$ to $^{72}Ge^+$ (or $^{73}Ge^+$) were measured in high resolution mode ($R{\geq}10,000$) to separate potential isobaric interferences by high resolution ICP/MS. For method validation, the developed method was applied to the analysis of arsenic content in the NMIJ 7402-a codfish certified reference material (CRM) and the result was $37.07mg{\cdot}kg^{-1}{\pm}0.45mg{\cdot}kg^{-1}$ which is in good agreement with the certified value, $36.7mg{\cdot}kg^{-1}{\pm}1.8mg{\cdot}kg^{-1}$. Finally, the certified value of the total arsenic in the candidate laver CRM was determined to be $47.15mg{\cdot}kg^{-1}{\pm}1.32mg{\cdot}kg^{-1}$ (k = 2.8 for 95% confidence level) which is an excellent result for arsenic measurement with only 2.8 % of relative expanded uncertainty.

환경규제 대응을 위한 페인트 중의 중금속 분석용 인증 표준물질 개발 (Development of Certified Reference Materials for Analysis of Heavy Metals in Paints to Cope with Environmental Regulations)

  • 유병규;선일식
    • 환경분석과 독성보건
    • /
    • 제21권4호
    • /
    • pp.209-219
    • /
    • 2018
  • In the areas of RoHS, WEEE, ELV and REACH, reinforcement of environmental regulations against harmful substances is a global trend not only in EC but also in all over the world. In the fields of Korea's major export products such as material parts, electrical and electronic products and automobile parts, we are responding to these regulations consistently. To develop reference material for analyzing lead and cadmium in paints, the candidate materials were produced through the screening process which separated shapes and sizes. To secure the traceability of the candidate materials produced, the characteristics and uncertainties are estimated by ICP-AES analysis using the primary reference material. The short-term and long-term stabilities also are evaluated in parallel. In order to calculate the final certification value of the candidate material, the verification were carried out by the performance evaluation through the comparison among the KOLAS (Korea Laboratory Accreditation Scheme) laboratories, and the CRM was produced in accordance with ISO Guide 35. The certified values and uncertainties of Pb and Cd of the final paint standard, determined according to the joint analysis among laboratories, are Pb [($191.4{\pm}3.1$) mg/kg, ($944.1{\pm}5.6$) mg/kg] and Cd [($45.0{\pm}2.6$) mg/kg, ($225.5{\pm}3.5$) mg/kg]. These standard materials were developed to enhance the reliability of measurement analysis, including the validity and traceability of measurement results. Also it is expected that the CRM will be used as QCM (quality control material) for the product design and the process monitoring, so that regulation and management of hazardous heavy metals can be systematically implemented.

표면분석용 인증표준물질의 개발 II : 깊이분포도용 다층 박막 표준물질의 개발 (Development of certified reference material (CRM)s for surface analysis II : multilayer thin films for sputter depth profiling)

  • 김경중;문대원
    • 한국진공학회지
    • /
    • 제8권3B호
    • /
    • pp.283-289
    • /
    • 1999
  • Multilayer thin film reference materials for the sputter depth profiling analysis are used to calibrate the sputter depth scale by measuring the sputtering rate and to optimize the sputtering conditions for the best depth resolution. Surface analysis group of Korea Research Institute of Standards and science (KRISS) have developed various types of multilayer thin films by using an ion beam sputter deposition and in-situ surface analysis system. The chemical states of the thin films reference materials were certified by in-situ XPS and the thicknesses were certified by transmission electron microscopy (TEM).

  • PDF

다중 프로브 검사 계측 장비를 위한 단차 표준 인증 물질의 설계 및 제작 (Design and Fabrication of a Step Height Certified Reference Material for Multi-probe Inspection Instruments)

  • 맹새롬;진종한;;김재완;김종안;강주식
    • 한국정밀공학회지
    • /
    • 제28권3호
    • /
    • pp.323-329
    • /
    • 2011
  • Certified reference materials (CRMs) have been used to calibrate surface profilers for reliable measurements. In this paper, we present a newly designed step height CRM which has a step height pattern with two different widths and various special patterns for checking radial magnification, distortion of optical viewing systems, etc. Especially, it could be useful for multi-probe inspection instruments in the manufacturing lines. The fabrication was done by conventional optical lithography and dry etching process with optimized conditions. To verify the step height values, a white-light scanning interferometer was used with objective lenses having magnification of $10{\times}$ and $100{\times}$. CRMs with nominal step heights of $0.5\;{\mu}m$, $1\;{\mu}m$, $3\;{\mu}m$, $5\;{\mu}m$, $7\;{\mu}m$, and $10\;{\mu}m$ were fabricated and the uniformity of these CRMs was evaluated to be less than 3 nm ($1{\sigma}$).

연소법 전처리에 의한 고분자 물질 중 중금속의 분석 (Analysis of heavy metal in polymer materials by combustion ICP-AES Method)

  • 임헌성;이보름;이석근
    • 분석과학
    • /
    • 제23권6호
    • /
    • pp.615-618
    • /
    • 2010
  • An oxygen bomb combustion procedure were studied for determination of heavy metal in polymer materials such as polyvinyl chloride and polypropylene by ICP-AES. This method is proposed as a rapid and simple sample preparation for decomposition of polymer containing certified contents of the analytes by teflon coated oxygen bomb combustion using different absorbing solution. The recoveries of metal were found to be 30~102% from absorbed solution by ICP-AES method using polypropylene certified reference material(PP CRM-As, Ba, Cd, Hg, Pb, Zn). The recoveries of metal using PVC CRM(Cd, Hg, Pb) was found to be 45 ~101% with same procedures.

실리콘에 도핑된 붕소의 정량분석에 대한 공동분석연구 (RRT Study for the Quantitative Analysis of Boron in Silicon)

  • 김경중;김현경;문대원;홍태은;정칠성;김이경;김재남;임철호;김정호
    • 한국진공학회지
    • /
    • 제11권4호
    • /
    • pp.218-224
    • /
    • 2002
  • 반도체 박막의 분석에서 중요한 분석 대상의 하나인 미량 불순물의 정량분석을 위한 표준절차를 확립하고 그에 필요한 인증표준물질의 개발하였으며 이를 이용하여 국내공동분석을 실시하였다. 공동분석에 사용된 붕소가 균질하게 도핑된 박막 인증표준물질과 분석시편은 이온빔 스퍼터증착법에 의해 제작하였으며, 가장 정량적이고 감도가 높은 ICP-MS를 이용한 동위원소희석법으로 인증하였다. 이러한 인증표준물질과 SIMS에 의한 실리콘 내 의 붕소의 정량분석에 대해 이미 확립되어 있는 국제표준절차인 ISO/DIS-14237에 의거하여 국내 공동 분석을 시행하였는데, 이번의 공동분석에서 얻어진 붕소농도의 전체 평균값이 ICP-MS에 의한 인증치에 약 2% 정도의 오차를 보여주고 있어 분석의 정확성이 확인되었다.

초임계유체추출과 GC/MS를 이용한 도심 대기분진 중 PAH들의 신속한 분석법에 관한 연구 (A Rapid Method for Analysing Polycyclic Aromatic Hydrocarbons (PAH's) in Urban Dust Using Supercritical Fluid Extraction (SFE) and Gas Chromatography/Mass Spectrometry (GC/MS)허귀석, 김달호)

  • 허귀석;김달호
    • 대한화학회지
    • /
    • 제38권10호
    • /
    • pp.726-733
    • /
    • 1994
  • 대기부유분진(air particulate material)중에 존재하는 다환방향족탄화수소(polycyclic aromatic hydrocarbons, PAH)를 신속하고 정확하게 분석하기 위하여 대기부유분진 시료를 10ml의 초임계유체($N_2O$ )로 30분간 추출 후 별도의 전처리와 농축과정 없이 GC/MS에서 분석하여 분석시간과 분석과정을 단축 및 단순화하였다. 시료로서 NBS 대기부유분진 인증표준기준물질(certified particulate reference material, CRM)1649와 서울의 도심에서 채취한 대기부유분진 시료를 이용하여 기존의 추출법 및 분석방법과 비교하였다. 그 결과 본 분석방법은 기존의 분석법에 비해 회수율은 상대적으로 작았으나 재현성이 좋았으며 분석과정이 간단하고 분석시간이 현저히 단축됨을 알 수 있었다.

  • PDF