• Title/Summary/Keyword: CPH

Search Result 42, Processing Time 0.026 seconds

Transcript accumulation of carotenoid biosynthesis genes in the cyanobacterium Synechocystis sp. PCC 6803 during the dark-to-light transition is mediated by photosynthetic electron transport

  • Ryu, Jee-Youn;Song, Ji-Young;Chung, Young-Ho;Park, Young-Mok;Chow, Wah-Soon;Park, Youn-Il
    • Plant Biotechnology Reports
    • /
    • v.4 no.2
    • /
    • pp.149-155
    • /
    • 2010
  • Expression of the genes for carotenoid bio-synthesis (crt) is dependent on light, but little is known about the underlying mechanism of light sensing and signalling in the cyanobacterium Synechocystis sp. PCC 6803 (hereafter, Synechocystis). In the present study, we investigated the light-induced increase in the transcript levels of Synechocystis crt genes, including phytoene synthase (crtB), phytoene desaturase (crtP), ${\zeta}$-carotene desaturase (crtQ), and ${\beta}$-carotene hydroxylase (crtR), during a darkto-light transition period. During the dark-to-light shift, the increase in the crt transcript levels was not affected by mutations in cyanobacterial photoreceptors, such as phytochromes (cph1, cph2 and cph3) and a cryptochrome-type photoreceptor (ccry), or respiratory electron transport components NDH and Cyd/CtaI. However, treatment with photosynthetic electron transport inhibitors significantly diminished the accumulation of crt gene transcripts. Therefore, the light induction of the Synechocystis crt gene expression is most likely mediated by photosynthetic electron transport rather than by cyanobacterial photoreceptors during the dark-to-light transition.

Potential Accuracy of GNSS PPP- and PPK-derived Heights for Ellipsoidally Referenced Hydrographic Surveys: Experimental Assessment and Results

  • Yun, Seonghyeon;Lee, Hungkyu;Choi, Yunsoo;Ham, Geonwoo
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.6 no.4
    • /
    • pp.211-221
    • /
    • 2017
  • Ellipsodially referenced survey (ERS) is considered as one of the challenging issues in the hydrographic surveys due to the fact that the bathymetric data collected by this technique can be readily transformed either to the geodetic or the chart datum by application of some geoscientific models. Global Navigation Satellite Systems (GNSS) is a preferred technique to determine the ellipsoidal height of a vessel reference point (RP) because it provides cost-effective and unprecedentedly accurate positioning solutions. Especially, the GNSS-derived heights include heave and dynamic draft of a vessel, so as for the reduced bathymetric solutions to be potentially free from these corrections. Although over the last few decades, differential GNSS (DGNSS) has been widely adopted in the bathymetric surveys, it only provides limited accuracy of the vertical component. This technical barrier can be effectively overcome by adopting the so-called GNSS carrier phase (CPH) based techniques, enhancing accuracy of the height solution up to few centimeters. From the positioning algorithm standpoint, the CPH-based techniques are categorized under absolute and relative positioning in post-processing mode; the former is precise point positioning (PPP) correcting errors by the global or regional models, the latter is post-processed kinematic positioning (PPK) that uses the differencing technique to common error sources between two receivers. This study has focused on assessment of achievable accuracy of the ellipsoidal heights obtained from these CPH-based techniques with a view to their applications to hydrographic surveys where project area is, especially, few tens to hundreds kilometers away from the shore. Some field trials have been designed and performed so as to collect GNSS observables on static and kinematic mode. In this paper, details of these tests and processed results are presented and discussed.

Preparation and Polymerization of Alkenylsilanes (Alkenylsilane의 제조와 고분자화반응)

  • Kim, Chung Kyun;Choi, Soon Kyu;Park, Eun Mi;Jung, In Kyung
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.2
    • /
    • pp.88-97
    • /
    • 1997
  • The silyltriflates$(Ph_{3-n}SiH(OTf)_n)$have been produced by the reaction of triphenylsilane and triflic acid$(CF_3SO_3H)$at low temperature. These highly reactive compounds are a valuable reagent for the synthesis of numerous new functional substituted silane derivatives. The reaction of silyltriflates with alkenyl- and alkynylmagnesium bromide as well as organolithium compounds gave new silanes$Ph_2SiHR(R=\;C(CPh,\;CH=CH_2,\;CH_2CH=CH_2,\; (CH_2)_2CH=CH_2,\;(CH_2)_3CH=CH_2)$in high yields. The hydrosilation of prepared alkenyl- and alkynylsilanesPh_2SiHR$in the presence of a platinum catalyst(Pt/C) at high temperature$(200{\circ}C)$gave carbosilane polymers$((Ph_2SiCH=CPh)_n$and$(Ph_2Si(CH_2)m)n;\;m=2∼4, n{\ge}10)$along with five- and six-membered silaalkane ring compounds derived from intramolecular hydrosilation reactions. All of the prepared compounds are confirmed by NMR, UV, IR and mass spectroscopy as well as elemental analysis.

  • PDF

Development of a Measuring Instrument for the Coefficient of Luminous Intensity of Retro-Reflection of Miniature Telecentric Cameras (소형 텔레센트릭 카메라 광학계의 재귀반사 측정 방법 연구 및 측정 장치 개발)

  • Yeo, TaeWoon;Karasik, V.E.;Kim, Young Il
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.6
    • /
    • pp.334-339
    • /
    • 2014
  • In this paper, the optical properties of a miniature telecentric camera are studied analytically and experimentally. By means of optical properties, the luminous intensity of retro-reflection of a miniature telecentric optical system is investigated. First, from a simulation the theoretical value of the coefficient of luminous intensity of retro-reflection of a miniature telecentric system is estimated. Second, a miniature telecentric camera device is designed, and the value of the coefficient of luminous intensity of retro-reflection of the actual device is measured through experiment. From simulation and experiment, we found that both the estimated and observed values of the coefficient of luminous intensity of retro-reflection range from 0.002 to $0.03m^2/sr$ (P384200CPH: $0.0042-0.018m^2/sr$, P285200CPH: $0.0045-0.0297m^2/sr$, P321450S: $0.0021-0.00963m^2/sr$) at 1.4 to 4.9 arcminute. The results prove the significance of the mechanisms used to design the miniature telecentric camera, and the experimental method. Accordingly, with these significant results, this study contributes to the development of theory and practice in optical engineering science.

Immobilization of oxidative enzymes onto Cu-activated zeolite to catalyze 4-chlorophenol decomposition

  • Zol, Muhamad Najmi Bin;Shuhaimi, Muhammad Firdaus Bin;Yu, Jimin;Lim, Yejee;Choe, Jae Wan;Bae, Sungjun;Kim, Han S.
    • Membrane and Water Treatment
    • /
    • v.11 no.3
    • /
    • pp.195-200
    • /
    • 2020
  • In this study, a biocatalyst composite was prepared by immobilizing oxidoreductases onto Cu-activated zeolite to facilitate biochemical decomposition of 4-chlorophenol (4-CP). 4-CP monooxygenase (CphC-I) was cloned from a 4-CP degrading bacterium, Pseudarthrobacter chlorophenolicus A6, and then overexpressed and purified. Type X zeolite was synthesized from non-magnetic coal fly ash using acetic acid treatment, and its surfaces were coated with copper ions via impregnation (Cu-zeolite). Then, the recombinant oxidative and reductive enzymes were immobilized onto Cu-zeolite. The enzymes were effectively immobilized onto the Cu-zeolite (79% of immobilization yield). The retained catalytic activity of CphC-I after immobilization was 0.3423 U/g-Cu-zeolite, which was 63.3% of the value of free enzymes. The results of this study suggest that copper can be used as an effective enzyme immobilization binder because it provides favorable metalhistidine binding between the enzyme and Cu-zeolite.

Modulation of Bone Mass, Strength and Turnover by a Cervi Pantotrichum Cornu Herbal Acupuncture in adjuvant-Induced Arthritic Rats (Adjuvant로 유발된 관절염 실험용쥐에서 골체, 골강도 및 골대체율의 변화에 대한 녹용 약침의 효과)

  • Choi, Byeong-joon;Kim, Min-jeong;Park, Sang-dong;Lee, A-ram;Jang, Jun-hyouk;Kim, Kyung-ho
    • Journal of Acupuncture Research
    • /
    • v.19 no.5
    • /
    • pp.219-233
    • /
    • 2002
  • 면역억제활성이 알려진 Cerves korean TEMMINCK var. manchur-icus Swinhoe(Nokyong) 약침(CPH)은 다모 뿔의 녹용을 열수추출한 용액이다. 본 연구에서는 녹용 약침의 효과를 adjuvant 유발 관절염 실험용쥐를 이용하여 골체, 골강도 및 골대체율의 감소를 평가하였다. 위의 골 대사 관련 검정실험을 위하여 6주령의 암컷 실험용쥐에 20일간 약물투여를 실시하였다. 실험적인 관절염유발은 실험용쥐의 뒤쪽 다리에 Adjuvant를 주사하여 유발시킨 결과, 요부의 골 무기질함량과 밀도(BMC, BMD) 그리고 압축강도는 관절염 실험용쥐에서 감소되었다. 10일 경과 후 골형성도(BFR/BS, BFR/BV)의 조직형태학적 기준척도인 혈청 osteocalcin 수가 정상대조군과 비교해 볼 때 현저하게 감소되었다. 그러나, 몸무게로 나눈 BMC치는 관절염 유발군과 정상군 사이에 큰 차이가 보이지 않았다. 그리고 골무기질 함량은 정상군에 비해 감소하지 않았다. 20일 경과후 몸무게로 나누거나 나누지 않은 BMC치 모두, 관절염 군에서 요부 몸체의 골무기질 함량과 강도가 정상군과 비교해 볼 때 현저하게 감소되었다. 잔존 소주(小柱)의 무기질 침착 표면은 현저하게 감소하였으며 파골 세포의 수는 증가하였다. 초기부터 매일 Shinsu(B23)에 CPH 약침 투여(10, 20, $50{\mu}g/kg$)는 20일 경과후 만성적인 다리 부종을 현저하게 방지하였으며, 골 무기질함량, 골강도 및 소주골 형성등의 감소와 파골세포수 증가도 완화하였다. Adjuvant주사로 장애를 받았던 연령대비 요부 길이 증가도 유지되었다. 이러한 결과는 Adjuvant에 의한 관절염 실험용쥐의 2차적인 골관절염에서 충분히 요추 몸체뼈와 강도 감소를 나타내기 위해서는 적어도 20일이 필요하다는 것을 제시하였다. 본 결과로부터 CPH가 실험용쥐의 관절염에 대한 골체, 골강도 및 골대체율을 조절하는데 유효하게 작용하고 있음을 알 수 있었다.

  • PDF

Cox Model Improvement Using Residual Blocks in Neural Networks: A Study on the Predictive Model of Cervical Cancer Mortality (신경망 내 잔여 블록을 활용한 콕스 모델 개선: 자궁경부암 사망률 예측모형 연구)

  • Nang Kyeong Lee;Joo Young Kim;Ji Soo Tak;Hyeong Rok Lee;Hyun Ji Jeon;Jee Myung Yang;Seung Won Lee
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.6
    • /
    • pp.260-268
    • /
    • 2024
  • Cervical cancer is the fourth most common cancer in women worldwide, and more than 604,000 new cases were reported in 2020 alone, resulting in approximately 341,831 deaths. The Cox regression model is a major model widely adopted in cancer research, but considering the existence of nonlinear associations, it faces limitations due to linear assumptions. To address this problem, this paper proposes ResSurvNet, a new model that improves the accuracy of cervical cancer mortality prediction using ResNet's residual learning framework. This model showed accuracy that outperforms the DNN, CPH, CoxLasso, Cox Gradient Boost, and RSF models compared in this study. As this model showed accuracy that outperformed the DNN, CPH, CoxLasso, Cox Gradient Boost, and RSF models compared in this study, this excellent predictive performance demonstrates great value in early diagnosis and treatment strategy establishment in the management of cervical cancer patients and represents significant progress in the field of survival analysis.

Railbed Evaluation by using In-situ Penetration Test (원위치 관입실험기를 활용한 철도 노반 평가)

  • Kim, Ju-Han;Park, Jung-Hee;Yoon, Hyung-Koo;Koh, Tae-Hoon;Lee, Jong-Sub
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.261-267
    • /
    • 2011
  • The test fit has commonly used for the evaluation of the railbed condition, and indirect methods by using the compressional wave are also studied. the direct evaluation method by penetration test has not been studied. For the measurement of in-situ cone tip resistance of the railbed with minimizing the disturbance of the upper railbed. the cone penetrometer with the helical type outer rod(CPH) was developed. The outer rod, which has helical screw, is penetrated through the gravel layer and provides the reaction force for cone penetration testing. the cone tip resistances are measured by the mini cone penetrometer, where diameter is 15mm. For the developing the mini cone, strain gauge installation, circuit configuration, penetration rates and calibration process are considered. For the easy penetration of the screw rod in the field, the reaction force stepping plate and guide column are arranged. The screw rod are penetrated through the gravel layer. And the mini cone was pushed into the subgrade railbed at the penetration rate of 1mm/sec. The penetration test shows that the cone tip resistance increases along the depth. In addition, the subgrade condition is evaluated. This study demonstrates that the CPH may be effectively used for the evaluation of subgrade method any damage of the gravel layer.

  • PDF

Automated Clinical best Result Analysis System - Application to liver function test - (퍼지이론을 이용한 임상검사 자동분석에 관한 연구 - 간기능검사 결과 자동분석시스템 -)

  • 차은종;이태수
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.341-348
    • /
    • 1993
  • Automated system to analyze liver function test results is presented based on fuzzy logic knowledge. Clinician's knowledge and experience was first expressed in linguistic terms fol- lowed by conversion to numerical values to create membership functions of disease possibility for each test item and liver disease. Membership functions were then compensated for different relative importances of test items. Liver diseases considered were acute viral hepatitis (AVH), chronic persistent hepatitis(CPH), chronic active hepatitis(CAH), and liver cirrhosis(LC), Liver function test results of alanine aminotransferase(ALT), aspartate amino- transferase(AST) , glutamate dehydrogenase(GDH), ornithine carbamyltransferase(OCT) , ALT/AST, and 10* GDH/ALT in 218 patients were analyzed by the present system, welch resulted in 80% accuracy. AVH and CAH showed the highest 93 % and the lowest 58% ac- curacies, respectively, which was similar to the clinician's expectation. The simple mathemat- ical formulation of the present system would enable an easy implementation in commercial analysis instruments. Also, the identical fuzzy logic can be applied to similar diagnostic envi- ronments in general.

  • PDF

Color Sensing and Signal Transmission Diversity of Cyanobacterial Phytochromes and Cyanobacteriochromes

  • Villafani, Yvette;Yang, Hee Wook;Park, Youn-Il
    • Molecules and Cells
    • /
    • v.43 no.6
    • /
    • pp.509-516
    • /
    • 2020
  • To perceive fluctuations in light quality, quantity, and timing, higher plants have evolved diverse photoreceptors including UVR8 (a UV-B photoreceptor), cryptochromes, phototropins, and phytochromes (Phys). In contrast to plants, prokaryotic oxygen-evolving photosynthetic organisms, cyanobacteria, rely mostly on bilin-based photoreceptors, namely, cyanobacterial phytochromes (Cphs) and cyanobacteriochromes (CBCRs), which exhibit structural and functional differences compared with plant Phys. CBCRs comprise varying numbers of light sensing domains with diverse color-tuning mechanisms and signal transmission pathways, allowing cyanobacteria to respond to UV-A, visible, and far-red lights. Recent genomic surveys of filamentous cyanobacteria revealed novel CBCRs with broader chromophore-binding specificity and photocycle protochromicity. Furthermore, a novel Cph lineage has been identified that absorbs blue-violet/yellow-orange light. In this minireview, we briefly discuss the diversity in color sensing and signal transmission mechanisms of Cphs and CBCRs, along with their potential utility in the field of optogenetics.