• 제목/요약/키워드: COUNTER

검색결과 3,655건 처리시간 0.029초

CNT와 Pt 상대전극을 가지는 염료감응형 태양전지의 직렬 ${\cdot}$ 병렬 연결에 따른 특성비교 (Comparative properties for serial-parallel connection of DSC with CNT and pt counter electrodes)

  • 최진영;홍지태;김미정;이용철;김희제
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.335-338
    • /
    • 2007
  • Cost effectiveness is an important parameter for producing DSSCs as compared to the widely used conventional silicon based solar cells. A fluorine-doped tin oxide (FTO) substrate coated with a catalytic amount of platinum is used as counter electrode in dye-sensitized solar cell. Carbonaceous materials are quite attractive to replace platinum due to their high electronic conductivity, corrosion resistance towards $I_{2}$, good catalytic effect and low cost. In this paper, the unit DSSCs with Pt and CNT as a counter electrode were connected in series-parallel externally, then the current-voltage curves were investigated to find out the connection characteristics of the DSSC with CNT counter electrode. The connection characteristics of the DSSC with CNT counter electrode is superior to that of the DSSC with Pt counter electrode. And a parallel connection of the DSSC with CNT counter electrode has higher efficiency than a series connection of that.

  • PDF

전압 표준용 RSFQ counter회로의 설계 (Circuit design of an RSFQ counter for voltage standard applications)

  • 남두우;김규태;김진영;강준희
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.127-130
    • /
    • 2003
  • An RSFQ (Rapid Single Flux Quantum) counter can be used as a frequency divider that was an essential part of a programmable voltage standard chip. The voltage standard chip is composed of two circuit parts, a counter and an antenna Analog signal of tens to hundreds ㎓ may be applied to a finline antenna part. This analog signal can be converted to the stream of SFQ voltage pulses by a DC/SFQ circuit. The number of voltage pulses can be reduced by 2n times when they pass through a counter that is composed of n T Flip-Flops (Toggle Flip-Flop). Such a counter can be used not only as a frequency divider, but also to build a programmable voltage standard chip. So, its application range can be telecommunication, high speed RAM, microprocessor, etc. In this work, we have used Xic, WRspice, and L-meter to design an RSFQ counter. After circuit optimization, we could obtain the bias current margins of the T Flip-Flop circuit to be above 31% Our RSFQ counter circuit designs were based on the 1 ㎄/$\textrm{cm}^2$ niobium trilayer technology.

  • PDF

음이온계 약물의 간수송과정에 있어서 담체매개 수송의 약물동력학적 모델링 및 시뮬레이션 (Pharmacokinetic Modeling and Simulation of the Carrier-Mediated Hepatic Transport of Organic Anions)

  • 이준섭;강민희;김묘경;이명구;정석재;심창구;정연복
    • 약학회지
    • /
    • 제47권2호
    • /
    • pp.110-119
    • /
    • 2003
  • The purpose of the present study was to kinetically investigate the carrier-mediated uptake in the hepatic transport of organic anions, and to simulate the ″in vivo counter-transport″ phenomena, using kinetic model which was developed in this study. The condition that the mobility of carrier-ligand complex is greater than that of free carrier is not essential for the occurrence of ″counter-transport″ phenomenon. To examine the inhibitory effects on the initial uptake of a ligand by the liver, it is necessary to judge whether the true counter-transport mechanism (trans-stimulation) is working or not. The initial plasma disappearance curves of a organic anion were then kinetically analyzed based on a flow model, in which the ligand is eliminated only from the peripheral compartment (liver compartment). Moreover, ″in vive counter-transport″ phenomena were simulated based on the perfusion model which incorporated the carrier-mediated transport and the saturable intracellular binding. The ″in vivo counter-transport″ phenomena in the hepatic transport of a organic anion were well demonstrated by incorporating the carrier-mediated process. However, the ″in vivo counter-transport″ phenomena may be also explained by the enhancement of back diffusion due to the displacement of intracellular binding. In conclusion, one should be more cautious in interpreting data obtained from so-called ″in vivo counter-transport″ experiments.

장비정도관리에 Calibrator[I-125] Set 적용 (The Application of New Calibrator[I-125]Set for Equipment Quality Management)

  • 김지나;안재석;원우재
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

Effects of Counter-rotation Position on Knee/Hip Angulation, Center of Mass Inclination, and Edging Angle in Simulated Alpine Skiing

  • Yoon, Sukhoon;Kim, Jin-Hae;Park, Jae-Hyeon;Ryu, Jiseon;Park, Sang-Kyoon;Kim, Joo-Nyeon
    • 한국운동역학회지
    • /
    • 제27권2호
    • /
    • pp.91-97
    • /
    • 2017
  • Objective: To investigate rotation movement of segment for performing each position and its effect on knee/hip angulation, COM inclination, and edging angle changes. Method: Twelve Alpine skiers (age: $25.8{\pm}4.8years$, height: $173.8{\pm}5.9cm$, weight: $71.4{\pm}7.4kg$, length of career: $9.9{\pm}4.6years$) participated in this study. Each skier was asked to perform counter-rotation, neutral, and rotation positions. Results: Shank and thigh were less rotated in the counter-rotation position than in other positions, whereas the trunk and pelvis were more counter-rotated (p<.05). Hip angulation, COM inclination, and edging angle were significantly greater in the counter-rotation position than in other positions (p<.05). Conclusion: Our finding proved that the counter-rotation position increases hip angulation, COM inclination, and edging angle. Consequently, we suggest that skiers should perform counter-rotation of the trunk and pelvis relative to the ski direction in the vertical axis for the counter-rotation position. Further analysis will continue to investigate the effects of the counter-rotation position in real ski slope with kinetic analysis.

테러대응을 위한 국가기관의 과제와 전망 (Subject and Prospect of Terror Confrontation National Institution)

  • 박준석
    • 시큐리티연구
    • /
    • 제17호
    • /
    • pp.157-172
    • /
    • 2008
  • 21세기의 세계화, 정보화 시대에서 국가의 안보목표를 달성하기 위한 하나의 수단이 국가 정보라고 할 수 있겠다. 국가안보의 목표를 충실히 달성하기 위해서는 안보환경에 변화에 따라 신축성 있게 부응하는 것이 국민들로부터 신뢰와 지지를 받는 길이므로 매우 중요하다. 그에 따른 국가정보체계는 세계의 안보적 차원에서 군사적, 비군사적 등 수집목표활동이 확대되고 다양한 분야로 정보 첩보들이 복잡하게 연계되어 있기 때문에 체계적으로 파악하기 위해서는 종합적 정보 체계의 확립이 요구된다. 인터넷의 발달로 정부기관은 보다 전문성과 사회성이 있는 정보생산을 위해 노력해야 할 것이다(세종연구소, 2007). 이와 같이 국가위기관리 측면에서 테러의 분야는 여러 사태 중에서도 가장 중요한 분야라고 사료 된다. 지난 17대 때에 테러 방지법이 통과되지 못했지만, 이번 18대에는 법적 반대하는 부분을 원활하게 상호 협조하여 대 테러법이 우선적으로 제정 되야 하는 것이 가장 중요하다고 본 연구자는 생각한다. 인권단체나 수사권에 관련된 기관들 간의 상호 협조, 권한에 대한 양보와 이해가 절실히 필요할 것이다. 본 연구자는 국가정보원 주관으로 국가정보의 국민의 홍보, 교육 참여, 신고, 포상, 피해 보상, UCC제작, 획일 된 대테러 교보제 제작, 대테러 전문가 양성, 대테러 학회 및 협회 창설, 대테러 연구소 설립 등 대테러 정보센타의 소극적 움직임을 탈피하여 적극적인 움직임으로의 전환을 통하여 국민의 대응조치 예방 사전지식을 계몽, 국가정보기관의 이미지 개선이 꼭 필요한 시점이라 사료된다. 즉, 과거 국가정보기관의 인식 탈바꿈과 국익도 필요하겠지만, 국민 개개인의 안전보장을 영위하며 함께 발전할 수 있는 계기가 필요할 것이다.

  • PDF

고성능 엇회전식 축류팬의 공력특성에 대한 전산해석 (Numerical analyses on the Aerodynamic Characteristics of a Counter-rotating Axial Flow Fan)

  • 조이상;조진수
    • 융복합기술연구소 논문집
    • /
    • 제5권1호
    • /
    • pp.37-40
    • /
    • 2015
  • Numerical analyses on the aerodynamic characteristics of a counter rotating axial flow fan is carried out using the frequency domain panel method. Front rotor and rear rotor blades of a counter rotating axial fan are designed by using the simplified meridional flow analysis method with the radial equilibrium equation and the free vortex design condition, according to design requirements. Performance characteristics of a counter rotating axial flow fan are estimated for the variation of design parameters such as the hub to tip ratio, the taper ratio and the solidity. Pressure losses were higher at leading edge and hub region of rotor blades. Characteristic curve of the counter rotating fan was overpredicted without consideration of viscous effect.

카운터 밸런스 밸브를 내장한 양방향 유압 브레이크 시스템 개발 (Development of double acting brake system integrated counter balance valve)

  • 김형의;이용범;윤소남;이일영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.962-967
    • /
    • 1991
  • A counter balance valve is used as one part of hydraulic motor brake system. The function of this valve is to protect over-run or free falling of inertia load. But occasionally the brake system with counter balance valve makes some undesirable problems such as pressure surges or vibrations. In this study, for the purpose of easy estimation about dynamic characteristics of hydraulic system including counter balance valve, precise formulation describing fluid dynamics and valve dynamics under various boundary conditions were made. Dynamic characteristics were analysed by numerical integration using Runge-Kutta method, because the equations in this circuit with counter balance valve contain various nonlinear terms. Propriety of this analysis method is verified by experiment. For the purpose of obtaining fundamental data for preventing instability, this study experimented the effects of the spool taper, spring constant, cylindrical choke. And we developed double acting brake system integrated counter balance valve.

  • PDF

PEDOT Polymer Film Based Counter Electrodes for Pt-free Dye-Sensitized Solar Cells

  • Kwon, Jeong;Park, Jong Hyeok
    • Journal of Electrochemical Science and Technology
    • /
    • 제4권3호
    • /
    • pp.89-92
    • /
    • 2013
  • Poly (3,4-ethylenedioxythiophene) (PEDOT) polymers with different electric conductivities were synthesized directly on a FTO substrate via a chemical polymerization method and applied as a platinum (Pt)-free counter electrode for dye-sensitized solar cells (DSSCs). The catalytic properties of the PEDOT as a function of electrical conductivity were studied using cyclic voltammograms, J-V measurements and impedance spectroscopy. The PEDOT counter electrode with around 340 S/cm conductivity exhibited the best performance as a counter electrode for tri-iodide reduction. The ability to modulate catalytic activity of PEDOT with changes in conductivity shows one of promising routes for developing new counter electrode of Pt-free DSSCs.

진공 환경내 실시간 입자 모니터링 시스템의 개발 및 성능평가 (Development and Performance Test of In-situ Particle Monitoring System using Ion-counter in Vacuum Environments)

  • 안강호;김용민;권용택
    • 반도체디스플레이기술학회지
    • /
    • 제5권1호
    • /
    • pp.45-49
    • /
    • 2006
  • In this paper, a new method that monitors the quantity of particles using ion-counter in vacuum environment is introduced. In-situ particle monitoring (ISPM) system is composed by Gerdien type ion-counter (house-made), DC power supply and electrometer. The ion-counter applied by positive voltage detects only positive charged particles. Therefore the particles to be detected should be in known charge state for further data analysis. ion-counter is installed at the exhaust line of process equipment where the pressure loss is structurally low. ISPM system performance has been verified with SMPS (Scanning Mobility Particle Sizer) system. The correlation coefficient is above 0.98 at the particle size range of $20{\sim}300nm$ in diameter with identified charge distribution under $0.1{\sim}10.0$ Torr.

  • PDF