• Title/Summary/Keyword: COLD AIR

Search Result 1,226, Processing Time 0.026 seconds

Analysis of Cold Air Flow Characteristics according to Urban Spatial Types to Construct a Wind Road - Focused on Urban Area of Changwon - (바람길 조성을 위한 도시공간유형별 찬공기 유동 특성 분석 - 창원시 도시지역을 중심으로 -)

  • LEE, Su-Ah;SONG, Bong-Geun;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.25 no.2
    • /
    • pp.30-47
    • /
    • 2022
  • This study analyzed the characteristics of cold air flow according to spatial types in urban areas of Changwon-si, Gyeongsangnam-do. The spatial types were classified by cluster analysis considering the land use map, building information, and topographic characteristics produced on the Changwon biotope map. The amount of cold air and wind speed were derived by KLAM_21 modeling. As a result, spatial types were classified into a total of 14 types considering the density and height of buildings, land use types, and topographic characteristics. Cold air flow was found to generate cold air in the valley of the forest area outside urban area, move through roads and open spaces, and accumulate in the low-lying national industrial complex, and then spread cold air throughout the urban areas. There was a lot of cold air flow in the tall building area, and the cold air accumulation was less in the slope and ridge areas. The results of this study were able to understand the characteristics of cold air flow according to building density, land use type, and topography, which will be usefully used as basic data for urban wind road construction to mitigate climate and improve air quality in urban areas.

Analysis and Management Strategies of the Cold Air Characteristics in Hannamgeumbuk-Jeongmaek and Geumbuk-Jeongmaek (한남금북·금북정맥 일대의 찬공기 특성 분석을 통한 청주시 찬공기 관리방안)

  • SON, Jeong-Min;EUM, Jeong-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.2
    • /
    • pp.152-171
    • /
    • 2019
  • In this study, we analyzed the characteristics of the cold air generated in Hannamgeumbuk and Geumbuk-Jeongmaek and proposed their management strategies. We also suggested management strategies after analyzing detailed cold airflows for Cheongju located Hannamgeumbuk-Jeongmaek and we compared the degree of nighttime temperature reduction of the Jeongmaek by using data obtained from observatories located on Cheongju. We used KALM(Kaltluftabflussmodell), a cold air simulation model developed in Germanay and identified both cold airflows and altitude of cold air layers generated during 360minutes at night. As a result, the cold airflow generated in the Jeongmaek became strong and the cold air was appeared clearly in the western part of the Hannamgeumbuk-Jeongamek and in the northern part of the Geumbuk-Jeongmaek. The average velocity of cold airflow was recorded at 0.45m/s, and the maximum speed of cold airflow was recorded at 2.70m/s. The average height of the cold air layer was 104.27m/s and the maximum thickness was 255.0m. The average velocity of cold airflows in Cheongju was 0.51m/s and the average height of cold air layer was 48.87m high. The highest degree of nighttime temperature reduction appeared in the Cheongnamdae observatory($-3.8^{\circ}C$), where the altitude of the cold air layer is high. The results showed that cooling effect of Jeongmaek actually affected the temperature reduction during nighttime. Based on the results, we designated the main mountain area of the Jeongmaek with active cold air generation as "cold air conservation areas" and proposed the current forest and topography conservation. We also proposed to designate areas that facilitate the cold airflows as "cold air management areas" and to complement the function of Jeongmaek. This study could support the establishment of systematic management plans of the Jeongmaek. In addition, it is expected that the results can be applied as basic data for ventilation paths of Cheongju.

The Effect of Cold Air Therapy in Release of Inflammation on Rheumatoid Arthritis (류머티스 관절염 환자에게 한랭치료가 염증완화에 미치는 효과)

  • Nam, Ki-San;Han, Kyoung-Ju;Lee, In-Hak;Moon, Sung-Ki
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.5 no.2
    • /
    • pp.85-93
    • /
    • 2007
  • Summary of background data: It is researched until now and the researches against the effect of position cold treatment the effect which pain threshold, change of skin temperature, researches the effective stiffness, the coldness in the patient it applied and relax an inflammation do the researches against were insufficient. Purpose: This project was to see how much it gives effect by using the cold air therapy an inflammation relief of rheumatoid arthritis patient. Methods: The medical subjects were 10 people from standard to diagnosis category of American College of Rheumatology(ACR) who had rheumatoid arthritis and to inspect informations about inflammation relief, have inspected ESR(erythrocyte sedimentation rate) and WBC(white blood cells). The experiment method was to let the patient bend the joint and lay down flat and treat with cold air from 10 cm away from joint line repeating 5 minutes treatment 1 minute rest and 3 minutes treatment. ESR and WBC cold air therapy reported with 5 days gap and each patient has been applied for 3 times. Result: The 5th day and 10th days ESR and WBC value shows when using cold air therapy, there was a reduction on rejected group but didn't last long, but 15th day it showed only on WBC it had its attention. Conclusions: So the cold air therapy shows it has positive effects on inflammation relief of rheumatoid arthritis patient.

  • PDF

Observation of the Cold-air Drainage and Thermal Belt Formation in a Small Mountainous Watershed by Using an Infrared Imaging Radiometer (적외선 영상 복사계를 이용한 산간집수역의 찬공기 배수와 온난대 형성 관측)

  • Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.2
    • /
    • pp.79-86
    • /
    • 2011
  • Cold-air drainage and pooling occur in most mountain valleys at night. Local climates with cold-air pooling could affect phenology and distribution of crop plants. A high resolution infrared imaging radiometer was used to visualize the cold-air drainage and thermal belt formation over a small mountainous watershed (ca. $10{\times}5{\times}1$ km for the maximum length${\times}$width${\times}$depth). Thermal images on $640{\times}480$ pixels were scanned across the Akyang valley (south of Mt. Jiri National Park) by the radiometer installed at a local peak ('Hyongjebong', 1,117 m a.s.l.) at dawn of 17 May 2011, when the synoptic condition was favorable for the surface cooling and cold-air drainage. Major findings are: (1) Cold-air drainage and accumulation was clearly identified by the lowest brightness temperature mainly at the valley bottom. (2) So-called 'thermal belt' with higher brightness temperature was found partway up the valley sidewalls and showed up to $5^{\circ}C$ departure from the valley bottom temperature. (3) Digital thermography showed feasibility for validation of the high definition geospatial temperature models currently in use for the plot-specific agrometeorological service.

Present Situation and Analysis of Cold Storage Facilities for Fisheries Products (수산물 냉동냉장설비의 현황 및 분석)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.406-412
    • /
    • 2011
  • This paper describes the analysis on freeze and refrigeration capacity of cold storage facilities for fisheries products during the last 15 years. And based on the analysis results, we prospect the number and scale of cold storage facilities in the near future. The main analysis results are summarized by the followings; Under the present conditions, the number and scale of our facilities is 879 and 3,586,824 ton, respectively. In comparison of the present and last 15 years ago, the business number increases about 22%, the accommodation capacity increases approximately 80%. In the reported update reference with the related data during the last 15 years, the capacity of cold storage facilities in 2011 expects to reach up to 4,600,000 ton. The newlyestablished facility in 2011 has the function of a multi-purpose distribution center as well as the existing cold storage, but this facilities converges in the capital area. Therefore, in this paper, we provided the basic reference data for the present situation and prediction of our cold storage facilities. But it is necessary to investigate and analyse widely our cold storage facilities for fisheries products in the near future.

Effects of the partial admission rate and cold flow inlet-outlet ratio on energy separation of Vortex Tube (Vortex Tube의 부분유입율과 저온 입.출구비가 에너지분리 특성에 미치는 영향)

  • 김정수;추홍록;상희선
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.51-59
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air conditioner for special purpose. The phenomena of energy separation through the vortex tube were investigated to see the effects of cold flow inlet-outlet ratios and partial admission rates on the energy separation experimentally. The experiment was carried out with various cold flow inlet-outlet ratios from 0.28 to 10.56 and partial admission rates from 0.176 to 0.956 by varying input pressure and cold air flow ratio. To find best use in a given cold flow inlet-outlet ratio and partial admission rate, the maximum temperature difference of cold air was presented. The experimental results were indicated that there are an optimum range of cold flow inlet-outlet ratio for each partial admission rate and available partial admission rate.

  • PDF

A Study on the District Community Cooling System using LNG Cold Energy (LNG 냉열이용 지역집단 냉방시스템에 대한 연구)

  • Kim, Chung-Kyun;Kim, Seung-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.27-30
    • /
    • 2010
  • This paper presents the system design process of district community cooling system using LNG cold energy. The newly developed LNG cooling system includes several heat exchangers, LNG storage tank, thermal mass storage tank, several cold energy storage tanks, gas air-conditioners, compressors, constant pressure regulators, cold energy and hot energy supply pipes. In addition, the gas air-conditioner system is installed to supply not sufficient cold energy due to low level of city gas consumptions during a summer period. This system design is very effective and safe to supply cold energy mass of fresh air by exchanging two thermal masses of an air and 200kcal/kg cold energy of LNG. The district community cooling system with LNG cold energy does not produce CO2 and freon gases in the air.

Development of Environment Friendly Cold Air Grinding System (환경친화형 냉풍연삭시스템 개발)

  • Kim, J.D.;Noh, I.H.;Sung, S.H.;Kim, W.M.;Oh, S.C.;Lee, D.H.;Kwan, K.M.;Jeon, Y.H.;Kim, H.K.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.950-955
    • /
    • 2003
  • Recently, emerging as major tasks are grobal warming prevention, and earth environment conservation and preservation, and the resolution of environmental issues is crucial in the 21st century and needs to jointly be tackled by all nations in cooperation with each other. This research developed dry cold air grinding system, and this ensured cold effects of machine tools and dressing effects against loading phenomenon of grinding wheel, thus extending the tool life of grinding wheel.

  • PDF

Study of the air liquefaction system using the LNG cold energy (LNG 냉열을 이용한 공기 액화의 특성 연구)

  • Park, Dong-Hoon;Yun, Sang-Kook
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.233-234
    • /
    • 2006
  • LNG is extremely cold, $-160^{\circ}C$ in its liquid state. When it vaporizes, returning to its natural state (re-vaporization), it cools its surroundings. This is cold energy. The manufacturing of liquid air is the first processes developed as the most effective utilization of LNG cold. In this paper, adopting the LNG cold process for manufacturing liquid air was developed and analysed. The result showed that as the higher air pressure and adapting nitrogen precooling, liquefaction rate and cumulative mass was increased.

  • PDF

Study on the Performance Improvement according to Arrangement Angle of Baffle and Location of Air Duct in the Cold Air Dryer (냉풍 건조 시스템의 배플 배열각도 및 공기공급관 위치 변화에 따른 성능 향상에 관한 연구)

  • Yun, Chung-Kug;Yu, Ki-Tae;Park, Chul;Song, Hee-Geun;Bae, Kang-Youl;Chung, Han-Shik;Jeong, Hyo-Min
    • Journal of Power System Engineering
    • /
    • v.21 no.4
    • /
    • pp.62-69
    • /
    • 2017
  • Because the moist foods like anchovy were appeared lower quality by hot air that occurred the lipid oxidation, the drying system by using the cold air has been used widely. This study has been carried out on the performance improvement according to arrangement angle of baffle and location of air duct in the cold air dryer. The main parameters in this study are the arrangement angles which are without, $0^{\circ}$, $10^{\circ}$, $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$, and the locations of air duct are without, front, center and back. For this study we have conducted the numerical analysis method using fluent in order to obtain the optimal condition of the drying performance. As the arrangement angle of baffle is increased, the relative humidity is proportionally decreased, the value at $40^{\circ}$ is 42.2% that indicate the reduction of about 4% than without it. After the air duct was installed, the decreased relative humidity is showed within 1%, therefore, the effect of air duct for improving the dry capacity is more large than the arrangement angle of baffle. Finally, we have obtained the optimal conditions that the arrangement angle is $40^{\circ}$ with the air duct for a cold air dryer.