• Title/Summary/Keyword: CO2 tension

Search Result 217, Processing Time 0.025 seconds

Measuring Interfacial Tension between Brine and Carbon Dioxide in Geological CO2 Sequestration Conditions using Pendant Bubble Methods (수적(垂滴)법을 이용한 이산화탄소 지중저장 조건에서의 염수-이산화탄소 간 계면장력 측정)

  • Park, Gyuryeong;An, Hyejin;Kim, Seon-ok;Wang, Sookyun
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.6
    • /
    • pp.46-55
    • /
    • 2016
  • This experimental study was aimed to estimate interfacial tension of brine-$CO_2$ by using a pendant bubble method and image analysis. Measurements were performed for wide ranges of temperatures, pressures, and salinities covering reservoir conditions in Pohang basin, a possible candidate for $CO_2$ storage operation in Korea. The profiles of $CO_2$ bubbles in brine obtained from image analysis with the densities of brine and $CO_2$ from previous studies were applied to Laplace-Young equation for calculating interfacial twnsion in brine-$CO_2$ system. The experimental results reveals that the interfacial tension is significantly affected by reservoir conditions such as pressure, temperature and water salinity. For conditions of constant temperature and water salinity, the interfacial tension decreases as pressure increases for low pressures (P < $P_c$), and approaches to a constant value for high pressures. For conditions of constant pressure and water salinity, the interfacial tension increases as temperature increases for T < $T_c$, with an asymptotic trend towards a constant value for high temperatures. For conditions of constant pressure and temperature, the interfacial tension increases with increasing water salinity. The trends in changes of interfacial tension can be explained by the effects of the reservoir conditions on the density difference of brine and $CO_2$, and the solubility of $CO_2$ in brine. The information on interfacial tensions obtained from this research can be applied in predicting the migration and distribution of injecting and residual fluids in brine-$CO_2$-rock systems in deep geological environments during geological $CO_2$ sequestrations.

The Effect of Co-culture and Oxygen Concentration on In Virto Fertilization of Follicular Oocytes in Korean Native Cattle (공배양 및 산소농도가 한우 난포란의 체외발생에 미치는 영향)

  • 이재관;윤준진;황성수;윤종택;김창근;정영채
    • Korean Journal of Animal Reproduction
    • /
    • v.22 no.1
    • /
    • pp.43-50
    • /
    • 1998
  • The effect of oxygen tension on embryonic development in co-culture was evaluated from the standpoint of the reduction of dissolved oxygen concentration by the oxygen consumption of feeder cells. Three co-culture systems using bovine oviductal epitherial cells (BOEC), African green monkey kidney cells (Vero cells) or buffalo rat liver cells (BRLC) have been compared in terms of development of bovine embryos derived from oocytes matured and fertilized in vitro. Among the co-cultured embryo, Vero cells su, pp.rted the highest developmental rate (29%) and the other two showed the similar rates. When the co-cultures were incubated in three different oxygen tension such as 5, 10, 20% oxygen atmosphere, embryos co-cultured with Vero cells at 10%-O2 resulted in the highest percentage of development. From the measurement of oxygen consumption of feeder cells, BRLC consumed 1.38 10-10 mg-O2/min/cell which was higher than 0.94 10-10 and 0.26 10-10mg-O2/min/cell for Vero cells and BOEC, respectively. Based on the oxygen consumption data, the phenomena of optimum oxygen tension required in embryo development in vitro has been analyzed, and we suggested that gas phase oxygen concentration, oxygen consumption rate of feeder cells and the number of feeder cells should be considered for the design of optimal co-culture system for effective fertilization of embryos in vitro.

  • PDF

Transmission Error Influences by Initial Tension of Timing Chain System (타이밍 체인 시스템의 초기 장력이 전달 오차에 미치는 영향)

  • Park, Yongsik;Jung, Taeksu;Hong, Yunhwa;Kim, Youngjin;Park, Youngkyun;Lee, Jungjin;Cho, Chongdu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.2
    • /
    • pp.133-139
    • /
    • 2017
  • The timing chain system, which is a typical power transmission technology applied to a vehicle, has been widely used by the automotive industry because it is normally designed to last a car's lifetime. However, the timing chain system may cause some problems due to the shape of the chains and the polygonal behavior on contact between the chain and the sprocket. In addition, noise and vibration caused by transmission error are the most typical problems encountered by major automotive manufacturers and they are considered as the main source of customer complaint. The initial tension of the chain-sprocket system is thought to be the main cause of transmission error, and it is regarded as the source of engine vibration and noise. The initial tension of the chain system should be controlled carefully since a low initial tension can cause twisting, which may lead to a system malfunction, while a high initial tension can reduce the service life due to a worn down contact surface. In this paper, the kinematic analysis model is generated with various initial tensions, which are controlled by changing the shape of the fixed guide with the largest contact surface with chain. The results showed that the transmission error was minimized on a particular range of initial tension, and the tendency showed that the error changed with a higher sensitivity at a lower initial tension.

Experimental Studies of the Blood Gas Transport during Normothermic Hemodilution Perfusion (상온하 혈액희석 체외순환에 있어서 혈액 GAS 동태에 관한 실험적 연구)

  • 박희철
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.85-91
    • /
    • 1980
  • Extracorporeal circulation by hemodilution technique has been currently used with its clinical safety and good peripheral tissue perfusion in open heart surgery. There is no doubt that $O_{2}$ carrying capacity of the blood is disturbed by decreased hemoglobin level resulting from hemodilution of the circulating blood. From the view point of the blood gas exchange, these experimental studies were undertaken to determined the sate limit of hemodilution in the condition of cardiopulmonary bypass with a constant perfusion flow rate. Twelve adult mongrel dogs weighing 10 to 13 Kg. were anesthetized with pentobarbital and then respiration was controlled with Harvard volume respirator using room air. The cardiopulmonary by pass was performed by use of Sarns heart lung machine (console 5000, 5 head and 2 roller pumps) and Travenol pediatric bubble oxygenator. The perfusion rate during bypass was maintained at a constant rate of 80 ml/min/Kg of body weight. The ratio of oxygen gas flow to blood flow was kept in 3 to 1 constantly. International hemodilution was attained by serial blood withdrawals and immediate infusion of equal volumes of diluants composed of Ringer's lactate, 5% dextrose in water and 25% mannitol solution, proportionally 60%, 30%, and 10%. Arterial and venous blood samples were obtained between 15 and 20 minutes following each hemodilution. Hematocrits and hemoglobin values, $PO_{2}$, $PCO_{2}$ and pH were measured. Oxygen and carbon dioxide contents oxygen consumption and carbon dioxide elimination were calculated groups according to different hematocrit values and the correlations were evaluated. Result were as follows. 1. the arterial $O_{2}$ tension and $O_{2}$ saturation were maintained at the physiological level irrespective of the hematocrit value. 2. The venous $O_{2}$ tension and $O_{2}$ saturation showed a tendency to decline with the decrease in hematocrit value and positive correlation between them (r = +0.49, r = +0.76), The mean values of venous $O_{2}$ tension and $O_{2}$ saturation, however, were not decreased when the hematocrit levels were lower than 20%. 3. The arterial $O_{2}$ content declined lineally in proportion to the fall of hematocrit level with a positive correlation between them (r = +0.95). 4. The venous $O_{2}$ contents were decreased gradually as the hematocrit value decreased with positive correlation between them ( r =+0.89). The trend of diminution of venous $O_{2}$ content, however, was became low according to progressive decrease of hematocrit level. 5. Systemic oxygen consumption was in higher range than $O_{2}$ requirement of basal metabolism when the hematocrit value was above 20%, but abruptly decreased when the hematocrit value became to below 20%. 6. The arterial $CO_{2}$ tension and $CO_{2}$ content showed trend of increasing with progressive decrease of hematocrit value but exhibited a rather broad range and there was no relationship between those value and the hematocrit value. 7. The venous $CO_{2}$ tension and $CO_{2}$ content have also no correlation with change of Ht. value but related directly to those value of arterial blood with positive correlation between them (r = +0.78, r = +0.95_. 8. A-V difference of $CO_{2}$ content and $CO_{2}$ elimination wasnot significantly influenced by Ht. value. From the results, we obtained that feasible limit in inteneional hemodilution is above the hematocrit value of 20% under the given experimental condition.

  • PDF

THE STUDY 0F TENS10N CHARACTERISTICS IN ORTHODONTIC WIRES (교정용 철사의 인장 특성에 관한 연구)

  • Park, Dae-Han;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.14 no.2
    • /
    • pp.241-248
    • /
    • 1984
  • The mechanical properties of Cr-Ni alloy of austenitic stainless steel and Co-Cr alloy orthodontic wires were studied in tension. The wires (0.018 inch) were tested in the as-manufactured and heat-treated conditions. Instron type tension testing machine was used for this study. Mean values and standard deviations were computed. The results were as follows; 1. The Cr-Ni orthodontic wires of austenitic stainless steel are generally superior than the Co-Cr orthodontic wires in ultimate tensile strength, In the elongation, however, Co-Cr orthodontic wire are superior than Cr-Ni orthodontic wires. 2. Increase in the degree of strength by heat treatment are more clearly shown in Co-Cr orthodontic wires than Cr-Ni orthodontic wires. And the elongation is decreased by heat treatment in both case. 3. The changes of the degree of strength by cooling method we not clearly shown, but in Cr-Ni orthodontic wires, air cooling are more effective, in Co-Cr orthodontic wires, cooling effect are scarcely shown.

  • PDF

THE INFLUENCE OF CATCH VOLUME ON TRAWLER WARP TENSION (어류가 대량으로 입강했을 때의 선미 trawl의 warp 장력)

  • Kim Cha Dol
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.2 no.2
    • /
    • pp.173-178
    • /
    • 1969
  • Few reports have been written regarding the measurement of stern trawler warp tension under conditions of a full catch. This report compares the tension imposed on the warps at the time the boat begins to tow the net and the tension at the time the cod end is filled with a large quantity of fish. The structure of the otter boards and trawl net used for the experiment was the same types as used by Koyama, Sakurai, and Sumikawa (1968). The warp tension was measured with a load cell tension meter. 3) This meter continuously records the tension on a pen oscillograph. The net towing speed was measured with the CM-lA type current meter, Toho Dentan Co. Ltd., Japan. The data collected in the experiment are shown in Table 1. This table indicates that shooting No. 2 and No. 11 show a large catch volume, and the types of fish caught are shown in Table 2. The tension meter recordings when the boat began to tow the net and when the cod end was filled with a large quantity are shown in Fig. 1 and Fig. 2. It is indicated that the barracouta Thyrsites atun (EUPHRASEN) causes little tension difference between the time before they enter the net and the time after they enter the net before hauling. Other types of fish influence tension similarly. According to these results, the warp tension measurements as recorded on a big stern trawler are more influenced by rough sea wave action than by the volume of fish caught.

  • PDF

Global Regulation of Gene Expression in the Human Gastric Pathogen Helicobacter pylori in Response to Aerobic Oxygen Tension Under a High Carbon Dioxide Level

  • Park, Shin Ae;Lee, Na Gyong
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.4
    • /
    • pp.451-458
    • /
    • 2013
  • The human gastric pathogen Helicobacter pylori (Hp) has been considered a microaerophile. However, we recently reported that, when supplied with 10% $CO_2$, Hp growth is stimulated by an atmospheric level of $O_2$, suggesting that Hp is a capnophilic aerobe. In this study, we investigated the effects of aerobic $O_2$ tension on Hp cells by comparing gene expression profiles of cultures grown under microaerobic and aerobic conditions in the presence of 10% $CO_2$. The results showed that overall differences in gene expression in Hp cells grown under the two $O_2$ conditions were predominantly growth-phase-dependent. At 6 h, numerous genes were down-regulated under the aerobic condition, accounting for our previous observation that Hp growth was retarded under this condition. At 36 h, however, diverse groups of genes involved in energy metabolism, cellular processes, transport, and cell envelope synthesis were highly up- or down-regulated under the aerobic condition, indicating a progression of the cultures from the log phase to the stationary phase. The expression of several oxidative stress-associated genes including tagD, katA, and rocF was induced in response to aerobic $O_2$ level, whereas trxA, trxB, and ahpC remained unchanged. Altogether, these data demonstrate that aerobic $O_2$ tension is not detrimental to Hp cells but stimulates Hp growth, supporting our previous finding that Hp may be an aerobic bacterium that requires a high $CO_2$ level for its growth.

A Case of Bilateral Tension Pneumothorax after the Successful CO2 Laser-assisted Removal of a Bronchial Foreign Body in a Child

  • Mun, In Kwon;Ju, Yeo Rim;Lee, Sang Joon;Woo, Seung Hoon
    • Medical Lasers
    • /
    • v.9 no.1
    • /
    • pp.65-70
    • /
    • 2020
  • Bronchial foreign body aspiration (BFA) is a common but emergent condition in infants and children. Furthermore, it can result in various complications such as atelectasis, pneumonia, bronchiectasis, and pneumothorax. Among these, pneumothorax is a very rare complication. However, it can be fatal without the swift implementation of appropriate treatment. We experienced a case of 16-month-old girl with an aspirated peanut. The foreign body was fixed in her left main bronchus. A CO2 laser was used to safely cut and break the foreign body. Removal was successful after breaking it. But after the process, inflammatory tissue of the tracheal mucosa was ruptured. Bilateral tension pneumothorax followed after the rupture. The patient was treated with bilateral chest tube insertion. Here we present this BFA case with a rare and unexpected complication. We also review the appropriate literature.

Numerical Investigation on the Effect of Surface Tension Change of Liquefied $CO_2$ Droplets on their Ascending Speed (액화이산화탄소 유적의 수직 상승속도에 미치는 표면장력 변화의 영향에 대한 수치연구)

  • Cho, Yoon-Tae;Song, Mu-Seok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.3
    • /
    • pp.160-163
    • /
    • 2008
  • $CO_2$ ocean sequestration is being considered as a way to earn a frame of time to change other industrial life pattern to overcome the global warming crisis. The method is to dilute the captured $CO_2$ into ocean by ejecting the liquefied $CO_2$ through nozzles. The main issue of such method is the effectiveness and safety, and in both problems the rising speed of those LCO2 droplet is the key parameter. In this paper, the rising speed of LCO2 droplets is numerically studied including the effect of the surfactant which can be residing along the density interface of the droplets. A front tracking method with a simple surface tension model is developed and the rising speed of the droplets is carefully investigated with varying the various parameters. It is demonstrated that the variable surface tension can change the deformation of the droplet, the flow near the interface, and the rising speed.

  • PDF

Effect of CO Intoxication on the Pulmonary Surfactant in Rabbits (일산화탄소중독(一酸化炭素中毒)이 가토(家兎) 폐포표면활성물질(肺胞表面活性物質)에 미치는 영향(影響))

  • Choo, Young-Eun;Lee, Suck-Kang
    • The Korean Journal of Physiology
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 1972
  • In order to observe a possible effect of CO intoxication on the activities of surfactant, the rabbit war exposed either to 0.1, 0.2 and 0.4% CO gas for two to six hours or 0. 1% CO gas for two hours daily for 1, 3 and 5 days, and the lung extract was prepared. The tension-area diagram of the lung extract was recorded automatically using the modified Langmuir-wilhelmy balance with a synchronized recording system, and the results were compared with control (i. e. : non-CO gas exposed normal rabbits). The results obtained are summarized as follows: 1. The maximal and minimal surface tensions, width of the tension-area diagram at the surface area of 40% in lung extract, and stability index of the normal rabbit lung extracts were $31.6{\pm}3.11\;dynes/cm,\;8.2{\pm}0.56\;dynes/cm,\;21.4{\pm}4.40dynes/cm\;and\;1.12{\pm}0.22$, respectively. 2. The activities of surfactant in the CO gas exposed group did not show any significant change from the control. 3. The above results suggest that CO gas produced no noticeable effect on the surfactant system of the lung.

  • PDF