Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

  • Kim, Ho Chul;Kim, Hee-Joung;Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.776-780
    • /
    • 2017
  • To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a $^{99m}Tc$ gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.

국소 간 병변의 발견: 1.5-T 자기공명영상에서의 자유호흡과 호흡유발 확산강조 영상의 비교 (Detection of Hepatic Lesion: Comparison of Free-Breathing and Respiratory-Triggered Diffusion-Weighted MR imaging on 1.5-T MR system)

  • 박혜영;조현제;김은미;허감;김용훈;이병훈
    • Investigative Magnetic Resonance Imaging
    • /
    • 제15권1호
    • /
    • pp.22-31
    • /
    • 2011
  • 목적: 이 연구의 목적은 간 병변 발견에 있어 1.5-T 자기공명영상에서 자유 호흡 확산강조 영상과 호흡 유발 확산강조 영상의 유용성을 비교하는데 있다. 대상 및 방법: 47명의 환자(평균 57.9세, 남성:여성 = 25:22)가 한번의 간 자기공명 영상검사에서 자유호흡 확산 강조 영상과 호흡유발 확산 강조 영상을 동시에 시행하였다. 이를 두 명의 영상의학과 의사가 호흡유발 이미지 세트(B50, B400, B800 확산강조 영상과 ADC map)와 자유호흡 이미지 세트를 2주간의 시간 간격을 두고 무작위로 후향적 분석을 시행하였다. 영상분석을 위하여 특정영역(ROI)를 설정한 후에 간의 신호대 잡음비 (signal-to-noise ratio, SNR)와 대조도(contrast-to-noise ratio, CNR)를 계산하였다. 결과: 32개의 낭종, 13개의 혈관종, 7개의 간세포암, 6국소 호산구성 간질환, 2개의 전이, 1개의 초점성 결절성 과증식과 글리슨막의 가성지방종을 포함하는 총 62개의 병변이 두 명의 평가자에 의하여 분석되었다. 비록 통계적 유의성을 없었으나, 전체적인 병변 발견의 sensitivity는 호흡유발 확산강조 영상이 [평가자 1:평가자 2, 47/62(75.81%):45/62(72.58%)] 자유호흡 확산강조 영상보다 [44/62(70.97%):41/62(66.13%)] 더 높은 수치를 보였다. 특히 1 cm보다 작은 국소 간 병변 발견의 sensitivity는 호흡유발 확산강조 영상이 [24/30(80%): 21/30(70%)] 지유호흡 확산강조 영상보다 [17/30(56.7%):15/30(50%)] 더 우월하였다. 진단적 정확도활 계산하기 위하여 ROC curve (Az value)를 구하였으며 자유호흡 확산강조 영상과 호흡유발 확산강조 영상간에는 통계적 차이는 없었다. 간의 신호대 잡음비 (SNR)와 대조도 (CNR)는 호흡유발 확산강조 영상이 ($87.6{\pm}41.4$, $41.2{\pm}62.5$) 자유호흡확산강조 영상보다 ($38.8:{\pm}13.6$, $24.8{\pm}36.8$) 높았으며 통계적인 유의성이 있었다. (p value < 0.001). 결론: 1.5-T자기공명 시스템서 1 cm보다 작은 간 병변발견에 있어서 호흡유발 확산강조 영상이 자유호흡 확산강조 영상보다 좋으며 이는 호흡유발 확산강조 영상이 높은 신호대 잡음비 (SNR)와 대조도(CNR)를 보이기 때문이다.

소아 SPECT/CT 검사를 위한 최저조건에서의 피폭선량측정 및 팬텀의 영상평가 (Abosrbed Dose Measurements and Phantom Image Ecaluation at Minimum CT Dose for Pediatric SPECT/CT Scan)

  • 박찬록;최진욱;조성욱;김진의
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.82-88
    • /
    • 2014
  • SPECT/CT로 소아 복부를 검사 하는데 있어 저선량 CT 조건에 따른 흡수선량을 측정하고 SPECT와 CT 영상의 질을 평가하고, 우수한 영상의 질을 유지하면서 최저의 흡수 선량을 받을 수 있는 tube voltage (kVp)와 tube current (mA)의 설정 방향을 알아보는데 목적을 두었다. 장비는 Discovery NM/CT 670을 사용하였다. PMMA phatom을 이용하여 80, 100 kVp 10, 15, 20, 25 mA의 조건을 설정하여 중심방향과 주변방향(3, 6, 9, 12시 방향의 평균) 의 흡수선량을 측정하였고, 그에 따른 image를 SNRD로 평가 하였다. CT QA performance phantom으로 CT image의 resolution을 MTF로 나타내었고, jaszczak phantom을 hot sphere와 배후방사의 비를 $^{99}mTc$을 1:8로 주입하여 4개의 sphere에 대한 SPECT image를 CNR로 평가하였다. 선량측정에서는 주변방향의 선량이 중심방향 선량보다 평균 7% 높게 측정되었으며, SNRD는 조건에 따라 유의한 차이가 없었으며 Resolution 평가에서는 0.385 lp/mm 기준으로 100 kVp가 80 kVp보다 평균 12% 재현성이 우수하였으며, jaszczak phantom을 이용해서 CT를 기반으로 한 attenuation correction 된 SPECT image를 CNR로 평가한 결과 CT조건의 변화와 무관하게 4개의 sphere 모두 유의한 차이를 보이지 않았다. 본 연구는 SPECT/CT 검사에서 최저의 흡수선량을 유지하고 우수한 영상의 질을 획득하는데 추가적인 연구가 필요할 것으로 사료된다.

  • PDF

SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화 (Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT)

  • 김지현;이주영;손현수;박훈희
    • 핵의학기술
    • /
    • 제25권2호
    • /
    • pp.15-24
    • /
    • 2021
  • SPECT/CT는 보급 초기에 뛰어난 보정방법과 융합영상을 기반으로 한 정성적 기능이 주목받았고, 최근 동반진단치료(Theranostics)등의 도입으로 그 정량적 기능에 대한 관심과 활용이 증가되는 추세이다. PET/CT와 달리 SPECT/CT의 절대 정량화는 조준기의 종류, 검출기 회전과 같은 조건들이 영상획득과 재구성 방법 등에 까다로운 요소로 작용하고 있다. 따라서 본 연구에서는 SPECT/CT 촬영조건 중 투영상수와 투영상당 획득시간에 따른 총 획득시간(검사시간)의 증·감이 방사능농도 추정치에 미치는 영향을 알아보고자 한다. 부피 9,293 ml의 원통형 팬텀에 멸균수를 가득 채운 후 99mTcO4- 91.76 MBq를 희석하여 총 획득시간 600 sec(10 sec/frame × 120 frames, matrix size 128 × 128)의 조건으로 기준영상을 촬영하였고, 체적감도와 교정인자를 확인하였다. 기준영상을 중심으로 총 획득시간을 60(-90%), 150(-75%), 300(-50%), 450(-25%), 900(+50%), 1200(+100%) sec/frame으로 증·감시켜 비교영상을 획득하였고, 각 영상별 세부조건은 투영상당 획득시간(sec/frame)을 1.0, 2.5, 5.0, 7.5, 15.0, 20.0 sec/frame(투영상수 120frames 고정)로, 투영상수를 12, 30, 60, 90, 180, 240 frames(투영상당 획득시간 10 sec/frame 고정)로 설정하였다. 획득된 각 영상에서 관심체적을 통하여 측정한 계수를 바탕으로 정성적 평가로서 CNR(Contrast to Noise Ratio)의 변동률(%)을 확인하였고, 방사능농도 추정치의 변동률(%)을 통해서는 정량적 평가를 시행하였다. 이때 방사능농도 추정치(cps/ml)와 실제 방사능농도(Bq/ml)의 관계는 회복계수(RC_Recovery Coefficients)를 지표로 비교·분석하였다. 투영상수 변화에 따른 결과[CNR 변동률(%), 방사능농도 추정치 변동률(%), RC]는 총 획득시간 증감률(%) -90%에서 [-89.5%, +3.90%, 1.04], -75%에서 [-77.9%, +2.71%, 1.03], -50%에서 [-55.6%, +1.85%, 1.02], -25%에서 [-33.6%, +1.37%, 1.01], +50%에서 [+33.7%, +0.71%, 1.01], +100%에서 [+93.2%, +0.32%, 1.00]이었으며, 투영상당 획득시간 변화에 따른 결과는 총 획득시간 증감률(%)-90%에서 [-89.3%, -3.55%, 0.96], -75%에서 [-73.4%, -0.17%, 1.00], -50%에서 [-49.6%, -0.34%, 1.00], -25%에서 [-24.9%, 0.03%, 1.00], +50%에서 [+49.3%, -0.04%, 1.00], +100%에서 [+99.0%, +0.11%, 1.00]이었다. SPECT/CT에서 총 획득시간의 증·감에 따라 획득된 총 계수와 그에 따른 영상품질(CNR)은 비례하여 변화하는 양상을 보였지만, 절대 정량화를 통한 정량적 평가에서는 모든 실험조건에서 5% 미만(-3.55에서 +3.90%)의 변화를 보여 큰 영향을 받지 않고 정량적 정확성(RC 0.96에서 1.04)을 유지하였다. 검사시간의 증가보다는 단축을 우선하여 고려하였을 때 총 획득시간 감소는 정성적 기능에 있어서 기존에도 배제할 수 없었던 사항이지만 정량적 기능은 큰 손실 없이 적용 가능하여 임상적으로 실효성이 있다고 판단된다. 다만 총 획득시간의 증·감 시 동일한 검사시간이라면 투영상수의 변경보다는 투영상당 획득시간의 변경이 정성적, 정량적으로 조건변화에 따른 변동 폭이 적은 것으로 나타났다.

PET/CT 팬텀의 3D 프린팅 소재 적용 가능성 평가 (Evaluation of the Applicability of PET/CT Phantom as a 3D Printing Material)

  • 이주영;김지현;박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권5호
    • /
    • pp.423-431
    • /
    • 2022
  • The purpose of this study is to present objective information in applying 3D printing technology for PET/CT (Positron Emission Tomography/Computed Tomography) performance evaluation and use it as a basic research that can be applied to various purposes in the future. Phantoms were manufactured with step wedge of ABS(Acrylonitrile Butadiene Styrene) and ACR(Acrylic acid) material. The counts for each ROI(Region of Interest) were analyzed through image acquisition in PET/CT. And the variation rate of counts and CNR(Contrast Noise Ratio) was evaluated. In the counts analysis, the effect of thickness occurred. In addition, in the variation rate analysis, the thickness setting of steps wedge 4 to 5 levels should be considered first. These results minimize quantitative and qualitative changes in the phantom manufactured based on 3D printing, and enable more stable PET/CT performance evaluation. Based on 3D printing in PET/CT, various phantoms are expected to be produced in the future. If the characteristics of each material are considered and applied through the basic research such as this research, the result of the phantom manufactured through 3D printing can be more meaningful and will be used in a wide range.

Simple Spectral Calibration Method and Its Application Using an Index Array for Swept Source Optical Coherence Tomography

  • Jung, Un-Sang;Cho, Nam-Hyun;Kim, Su-Hwan;Jeong, Hyo-Sang;Kim, Jee-Hyun;Ahn, Yeh-Chan
    • Journal of the Optical Society of Korea
    • /
    • 제15권4호
    • /
    • pp.386-393
    • /
    • 2011
  • In this study, we report an effective k-domain linearization method with a pre-calibrated indexed look-up table. The method minimizes k-domain nonlinear characteristics of a swept source optical coherence tomography (SS-OCT) system by using two arrays, a sample position shift index and an intensity compensation array. Two arrays are generated from an interference pattern acquired by connecting a Fabry-Perot interferometer (FPI) and an optical spectrum analyzer (OSA) to the system. At real time imaging, the sample position is modified by location movement and intensity compensation with two arrays for linearity of wavenumber. As a result of evaluating point spread functions (PSFs), the signal to noise ratio (SNR) is increased by 9.7 dB. When applied to infrared (IR) sensing card imaging, the SNR is increased by 1.29 dB and the contrast noise ratio (CNR) value is increased by 1.44. The time required for the linearization and intensity compensation is 30 ms for a multi thread method using a central processing unit (CPU) compared to 0.8 ms for compute unified device architecture (CUDA) processing using a graphics processing unit (GPU). We verified that our linearization method is appropriate for applying real time imaging of SS-OCT.

The Qualitative Analysis of Single Shot Fast Spin Echo (SSFSE) and Maximum Intensity Projection (MIP) on Magnetic Resonance Cholangiopancreatography

  • Park, Cheol-Soo;Cho, Jae-Hwan;Lee, Hae-Kag;Dong, Kyung-Rae;Chung, Woon-Kwan;Seok, Jong-Min;Han, Man-Seok;Lee, Sun-Yeob;Goo, Eun-Hoe;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • 제17권2호
    • /
    • pp.138-144
    • /
    • 2012
  • 3-dimensional magnetic resonance cholangiopancreatography (MRCP) images reconstructed using the maximum intensity projection technique were analyzed qualitatively in patients diagnosed with pancreatobiliary diseases to determine their diagnostic utility. Single shot fast spin echo (SSFSE), fast spin echo (FSE) and 3-dimensional reconstructive images were acquired from 20 patients diagnosed histologically with pancreatobiliary diseases using a 3.0T MR scanner. According to qualitative analysis, the fast spin echo images and 3-dimensional reconstructed images of the hepatic duct, gall bladder and common bile duct had a higher signal to noise ratio (SNR) than the single shot fast spin echo images. Fast spin echo images and 3-dimensional reconstructed images did not show any differences. The contrast to noise ratio of the hepatic duct, gallbladder and common bile duct on the fast spin echo images and 3-dimensional reconstructed images was higher than that of the single shot fast spin echo images. The fast spin echo images and 3-dimensional reconstructed images showed similar quality.

디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준 검사조건에 대한 고찰 (A Study on the Diagnostic Reference Level of Skull Radiography in Digital Radiography)

  • 정연진;주영철;홍동희;김상현
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.897-904
    • /
    • 2022
  • 본 연구의 목적은 디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준(DRL)에서 제시하는 검사 조건과 현재 임상에서 적용하고 있는 검사 조건 적용 시 선량과 화질의 차이 비교를 통해, 디지털 방사선환경에 적절한 두부 방사선검사의 조건에 대해 고찰하고자 한다. 본 연구는 두부모형팬텀을 대상으로 하였으며, 조사 조건은 임상에서 사용하는 조건(Clinic)과 DRL값(DRL75), DRL 평균값(DRLmean)으로 구분하여 실험하였다. 선량은 입사표면선량(ESD)을 측정하였고, 화질은 신호 대 잡음비와 대조도 대 잡음비를 측정하여 비교 분석하였다. 검사 조건 변화에 따른 skull AP ESD의 평균값은 Clinic 1214.03±4.21 µGy, DRL75 301 7.83±8.14 µGy, DRLmean 2283.50±7.09 µGy이었으며, skull Lat. ESD의 평균값은 Clinic 762.79±3.54 µGy, DRL75 2168.57±10.83 µGy, DRLmean 1654.43±6.48 µGy로 통계적으로 유의한 것으로 나타났다(p<0.01). 안와, 상악동, 전두동, 터키안장에서 측정한 SNR과 CNR의 평균값은 통계적으로 유의하였다(p<0.01). 본 연구 결과 임상에서 사용하는 조건이 DRL에 비해 AP는 약 58%, Lat.은 약 70% 정도의 낮은 선량 수치를 나타내었으며, 화질 측면에서 정성적인 차이가 없었다. 본 연구를 통해 디지털 방사선 환경에 적합한 새로운 진단참고수준에 대해 고려해 볼 필요가 있으며, 그에 따른 선량의 저감화가 이루어져야 할 것으로 사료된다.

Comparison of Three, Motion-Resistant MR Sequences on Hepatobiliary Phase for Gadoxetic Acid (Gd-EOB-DTPA)-Enhanced MR Imaging of the Liver

  • Kim, Doo Ri;Kim, Bong Soo;Lee, Jeong Sub;Choi, Guk Myung;Kim, Seung Hyoung;Goh, Myeng Ju;Song, Byung-Cheol;Lee, Mu Sook;Lee, Kyung Ryeol;Ko, Su Yeon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권2호
    • /
    • pp.71-81
    • /
    • 2017
  • Purpose: To compare three, motion-resistant, T1-weighted MR sequences on the hepatobiliary phase for gadoxetic acid-enhanced MR imaging of the liver. Materials and Methods: In this retrospective study, 79 patients underwent gadoxetic acid-enhanced, 3T liver MR imaging. Fifty-nine were examined using a standard protocol, and 20 were examined using a motion-resistant protocol. During the hepatocyte-specific phase, three MR sequences were acquired: 1) gradient recalled echo (GRE) with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA); 2) radial GRE with the interleaved angle-bisection scheme (ILAB); and 3) radial GRE with golden-angle scheme (GA). Two readers independently assessed images with motion artifacts, streaking artifacts, liver-edge sharpness, hepatic vessel clarity, lesion conspicuity, and overall image quality, using a 5-point scale. The images were assessed by measurement of liver signal-to-noise ratio (SNR), and tumor-to-liver contrast-to-noise ratio (CNR). The results were compared, using repeated post-hoc, paired t-tests with Bonferroni correction and the Wilcoxon signed rank test with Bonferroni correction. Results: In the qualitative analysis of cooperative patients, the results for CAIPIRINHA had significantly higher ratings for streak artifacts, liver-edge sharpness, hepatic vessel clarity, and overall image quality as compared to, radial GRE, (P < 0.016). In the imaging of uncooperative patients, higher scores were recorded for ILAB and GA with respect to all of the qualitative assessments, except for streak artifact, compared with CAIPIRINHA (P < 0.016). However, no significant differences were found between ILAB and GA. For quantitative analysis in uncooperative patients, the mean liver SNR and lesion-to-liver CNR with radial GRE were significantly higher than those of CAIPIRINHA (P < 0.016). Conclusion: In uncooperative patients, the use of the radial GRE sequence can improve the image quality compared to GRE imaging with CAIPIRINHA, despite the data acquisition methods used. The GRE imaging with CAIPIRINHA is applicable for patients without breath-holding difficulties.

B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성 (Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers)

  • 이재승;구은회;이선엽;박철수;최지원
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.683-690
    • /
    • 2009
  • 본 연구의 목적은 직장암 국소병변의 수술 전 검출을 위한 고 확산경사계수(High-b-values) 자기공명영상의 유용성을 평가하고자 한다. 직장암의 진단을 위하여 확산강조 자기공명영상을 시행한 60명의 환자 중 연령분포는 38 - 78세(평균 60세)였고 남자 40명, 여자가 20명 이었다. 사용된 장비는 1.5 Tesla 자기공명 영상기기(GE, General Electric Medical System, Excite HD)로 사용하였고, 검사 프로토콜은 고속기법 T2, T1강조영상을 얻은 후 정확한 병변 검출을 위하여 같은 위치를 정하여 확산강조영상을 얻었다. 확산강조영상의 b-value$(s/mm^2)$값은 250, 500, 750, 1000, 1500, 2000까지 변화시키면서 얻었다. 영상평가는 정량적 분석방법으로 직장, 방광과 종양간 대조도대 잡음비(rectum, bladder to tumor contrast noise ratio, 이하 CNR)를 GE software Functool tool을 사용하여 비교분석 하였고. 정성적 분석방법은 영상내의 인공물의 유무, 병변의 명확성, 직장벽 구분을 기준으로 네 명의 경험 있는 영상의학과 의사와 세 명의 방사선사가 영상을 분석하였다. 영상의 유의성 평가는 각 b-values 값에 대하여 ANOVA 검증과 Freedman 검증을 이용하여 분석하였다(p<0.05). 정량적 분석결과는 b-values 값 중 1000에서 직장, 종양의 평균 대조도대잡음비는 27.21, 24.44로 가장 높았고(p<0.05), 이때 확산계수는 $0.73\times10^{-3}$이었다. 정성적 분석결과로서, 병변의 명확성과 직장벽 구분은 $4.0\pm0.14$, $4.4\pm0.16$로 1000 값에서 가장 높았으며, 인공물유무는 $4.8\pm0.25$로 2000 값에서 높은 결과 이었다(p<0.05). 결론적으로, 확산강조영상은 수술 전 직장암 환자의 병변 검출에 유용성 있는 정보를 제공해 주었으며, 정확한 종괴의 발견을 위해는 고 확산경사계수 값 1000 영상이 가장 우수한 확산경사계수 값 이었다.