• Title/Summary/Keyword: CMIA

Search Result 8, Processing Time 0.01 seconds

Analysis of HBeAg and HBV DNA Detection in Hepatitis B Patients Treated with Antiviral Therapy (항 바이러스 치료중인 B형 간염환자에서 HBeAg 및 HBV DNA 검출에 관한 분석)

  • Cheon, Jun Hong;Chae, Hong Ju;Park, Mi Sun;Lim, Soo Yeon;Yoo, Seon Hee;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose Hepatitis B virus (hepatitis B virus, HBV) infection is a worldwide major public health problem and it is known as a major cause of chronic hepatitis, liver cirrhosis and liver cancer. And serologic tests of hepatitis B virus is essential for diagnosing and treating these diseases. In addition, with the development of molecular diagnostics, the detection of HBV DNA in serum diagnoses HBV infection and is recognized as an important indicator for the antiviral agent treatment response assessment. We performed HBeAg assay using Immunoradiometric assay (IRMA) and Chemiluminescent Microparticle Immunoassay (CMIA) in hepatitis B patients treated with antiviral agents. The detection rate of HBV DNA in serum was measured and compared by RT-PCR (Real Time - Polymerase Chain Reaction) method Materials and Methods HBeAg serum examination and HBV DNA quantification test were conducted on 270 hepatitis B patients undergoing anti-virus treatment after diagnosis of hepatitis B virus infection. Two serologic tests (IRMA, CMIA) with different detection principles were applied for the HBeAg serum test. Serum HBV DNA was quantitatively measured by real-time polymerase chain reaction (RT-PCR) using the Abbott m2000 System. Results The detection rate of HBeAg was 24.1% (65/270) for IRMA and 82.2% (222/270) for CMIA. Detection rate of serum HBV DNA by real-time RT-PCR is 29.3% (79/270). The measured amount of serum HBV DNA concentration is $4.8{\times}10^7{\pm}1.9{\times}10^8IU/mL$($mean{\pm}SD$). The minimum value is 16IU/mL, the maximum value is $1.0{\times}10^9IU/mL$, and the reference value for quantitative detection limit is 15IU/mL. The detection rates and concentrations of HBV DNA by group according to the results of HBeAg serological (IRMA, CMIA)tests were as follows. 1) Group I (IRMA negative, CMIA positive, N = 169), HBV DNA detection rate of 17.7% (30/169), $6.8{\times}10^5{\pm}1.9{\times}10^6IU/mL$ 2) Group II (IRMA positive, CMIA positive, N = 53), HBV DNA detection rate 62.3% (33/53), $1.1{\times}10^8{\pm}2.8{\times}10^8IU/mL$ 3) Group III (IRMA negative, CMIA negative, N = 36), HBV DNA detection rate 36.1% (13/36), $3.0{\times}10^5{\pm}1.1{\times}10^6IU/mL$ 4) Group IV(IRMA positive, CMIA negative, N = 12), HBV DNA detection rate 25% (3/12), $1.3{\times}10^3{\pm}1.1{\times}10^3IU/mL$ Conclusion HBeAg detection rate according to the serological test showed a large difference. This difference is considered for a number of reasons such as characteristics of the Ab used for assay kit and epitope, HBV of genotype. Detection rate and the concentration of the group-specific HBV DNA classified serologic results confirmed the high detection rate and the concentration in Group II (IRMA-positive, CMIA positive, N = 53).

Design of Steering Controller of AGV using Cell Mediate Immune Algorithm (세포성 면역 알고리즘을 이용한 AGV의 조향 제어기 설계에 관한 연구)

  • Lee, Yeong-Jin;Lee, Jin-U;Lee, Gwon-Sun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.10
    • /
    • pp.827-836
    • /
    • 2001
  • The PID controller has been widely applied to the most control systems because of its simple structure and east designing. One of the important points to design the PID control system is to tune the approximate control parameters for the given target system. To find the PID parameters using Ziegler Nichols(ZN) method needs a lot of experience and experiments to ensure the optimal performance. In this paper, CMIA(Cell Mediated Immune Algorithm) controller is proposed to drive the autonomous guided vehicle (AGV) more effectively. The proposed controller is based on specific immune responses of the biological immune system which is the cell mediated immunity. To verify the performance of the proposed CMIA controller, some experiments for the control of steering and speed of that AGV are performed. The tracking error of the AGV is mainly investigated for this purpose. As a result, the capability of realization and reliableness are proved by comparing the response characteristics of the proposed CMIA controllers with those of the conventional PID and NNPID(Neural Network PID) controller.

  • PDF

A Study on Steering Performance Improvement of the AGV using Cell-Mediated Immune Algorithm (세포성 면역 알고리즘을 이용한 AGV의 조향 성능 향상에 관한 연구)

  • Lee, Y.J.;Sohn, J.H.;Lee, J.W.;Cho, H.C.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2572-2574
    • /
    • 2000
  • In this paper, cell-mediated immune algorithm(CMIA) controller was proposed and applied for the autonomous guided vehicle(AGV) driving. It was based on specific immune response of the biological immune system which is the cell-mediated immunity. To verify the performance of the designed CMIA controller, some experiments were performed for the control of steering and speed of AGV. And then the displacement and speed tracking error of the AGV was mainly investigated. As results, the capability of realization and reliableness were proved by comparing the response characteristics of the classical controller with the proposed CMIA controller.

  • PDF

Comparison between the method of the measurement 25 Vitamin D3 (25 Vitamin D3 측정에 있어서 화학발광미세입자 측정법과 화학발광면역 측정법 간의 비교 및 고찰)

  • Kim, dae-won;Lee, jung-hee;Jung, an-na;Seo, so-yoen
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.112-114
    • /
    • 2015
  • Purpose Vitamin D to Anti- Rickets both steroid compounds showing activity, By acting on bone tissue secretary and the key to maintain serum Ca homeostasis. The blood level of vitamin D is the largest in D3 that the concentration of the metabolite is reflected in the holding state of vitamin D in vivo. Sunlight to change the 7-dehydrocholesterol in the skin and through the skin to D3, In the liver in combination with the D2 and D3 D4 changes. The Radioimmunoassay(RIA) method is measuring the D 3, the sensitivity can be measured also difficult trace substance to measure the normal test because it is very sensitive, but recently, a check is possible, for the Total D3 in Chemimicroparticle immunoassay(CMIA) or Chemiluminescent immunoassay(CLIA) measuring using microparticle RIA and CMIA(Architect i2000SR) / use the CLIA(DXI-800) method to compare and evaluate the correlation between the tests in the same test items. Materials and Methods Commissioned from January 2014 to March 2015 patients were enrolled in a total of 273 people. 29 out of 273 people conducted by RIA were compared with CMIA, 244 patients were compared with CLIA. Using reagents and equipment were used RIA(Diasource), CMIA(Architect i2000SR, Abbott Diagnostics) / CLIA( Unicel DXi-800, Beckman coulter). Results Correlation of the RIA and CLIA was a R2 = 0.1844 (y = 0.7303x + 3.9005), and the correlation of RIA CMIA is R2 = 0.2762 (y = 0.8862x + 4.56) respectively. (According to statistics, during the same period RIA is Deficiency 4.31%, Insufficiency 90.53%, Sufficiency 5.16%, was Excess 0%, CLIA / CMIA is Deficiency 17.02%, Insufficiency 75.91%, Sufficiency 7.03%, indicating the distribution of 0.03 % Excess) Conclusion Serum vitamin D and parathyroid hormone that show an inverse relationship, the level above which are not parathyroid hormone and vitamin D reduced the increase. The density is different for each study, at most 20 is reported to be the maximum between 30 ng / ml. In Korea it requires a proposed standard of vitamin D deficiency, reference to the WHO lack the case more than 10ng/ml, 20ng/ml and defined by the lack of, if not more than, the IOM, but looking at 12ng/ml or less to the normal to lack, at least 20ng/ml, the reference do not match the deficit under 20ng/ml, 21-29ng/ml relative lack between, was also defined as a sufficient condition for more than 30ng/ml. Although not statistically is between RIA and CLIA two ways to vitamin D levels change according to season match, when seasonally seen in summer as commonly known (April to September), winter (October to March) relative to the increase measured than it was found. Finally, the study on the correlation between the two methods have been expected to result in a consistent and apply the same view high reference value on the graph is difficult. However, there may be differences between the test equipment and methods, and could be especially the case of RIA method using an organic solvent is difficult to compare different methods and correlated view similar trend in vitamin D deficiency and quarterly aspect ratio.

  • PDF

A Design of Adaptive Controller based on Immune System (면역시스템에 기반한 적응제어기 설계에 관한 연구)

  • Lee Kwon Soon;Lee Young Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.12
    • /
    • pp.1137-1147
    • /
    • 2004
  • In this paper, we proposed two types of adaptive control mechanism which is named HIA(Humoral Immune Algorithm) PID and CMIA(Cell-Mediated Immune Algorithm) controller based on biological immune system under engineering point of view. The HIA PID which has real time control scheme is focused on the humoral immunity and the latter which has the self-tuning mechanism is focused on the T-cell regulated immune response. To verify the performance of the proposed controller, some experiments for the control of AGV which is used for the port automation to carry container without human are performed. The experimental results for the control of steering and speed of an AGV system illustrate the effectiveness of the proposed control scheme. Moreover, in that results, proposed controllers have better performance than other conventional PID controller and intelligent control method which is the NN(neural network) PID controller.

Comparison of Estradiol Results according to Manufacturer (제조회사에 따른 Estradiol 결과값의 비교)

  • Kim, Dae-Woon;Shin, Hee-Jung;You, Tae-Min;Noh, Gyeong-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.101-105
    • /
    • 2011
  • Purpose: Estradiol in the menstrual cycle and ovulation induction as an important test of currently national nuclear medicine laboratory in the normal patients and patients with infertility tests are being performed. For the diagnosis of menopause is an important test with follicle stimulating hormone (FSH) and Luteinizing hormone (LH). Currently participating in external quality control of the nation's hospitals that is 54 percent of 37 hospitals, 20 hospitals have been using A's reagent. The kit's test results are highly different from other kit comes with the test results of specimens have been found. And for the phenomenon is to study the problem. Materials and Methods: Estraiol test were referred to our hospital which results of samples as more than 100pg/ml 75 specimens measured by radioimmunoassay(RIA) test with company A company B company C company D Kit, Chemiluminescent assay (CMIA) to examine and compare to the results from april to August in 2010. Results: Kit for each manufacturing company as measured by the results obtained using the average value of the correlation coefficient (R2) and A company 0.8906 B 0.9527 C 0.9547 and D company correlation coefficient of 0.873 showed a good correlation that measuring the results of A company high concentrations when Company B Company C Company D with CMIA test concentrations measured low results that the two cases were discovered specimens. Conclusion: Most of the test results of 75 samples came up with a similar trend, but two cases were reported in the patients very differently. A company result reported higher than 700 pg/ml, while the rest of other test results report was approximately 10 pg/ml. The common point of two samples more than 50 years patients are estimated to be diagnosed with cancer in postmenopausal patients receiving treatment and levels of FSH were found to be greater than 50 mIU/ml. Did not identify the exact cause. I suggest if you are using A company kit that need to again check when Estradiol result and follicle stimulating hormone results is higher.

  • PDF

A convergence study on the Positive Rate of Hepatitis B Surface Antibody by Age before and after HBV Vaccination (B형 간염 예방접종 전후 연령별 B형 간염 표면항체 양성률에 대한 융합적 연구)

  • Kim, Jiro;Lee, Kyu-taeg;Chong, Moo-Sang
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.77-82
    • /
    • 2020
  • In order to analyze the positive rate of hepatitis B surface antibody by age before and after hepatitis B vaccination, 13,855 serum specimens who were referred for the hepatitis B surface antibody test at the General Hospital of Jeju Hospital were examined by CMIA method. The positive rate of HBs Ab was 5,176 (37.36%). The positive rate according to gender was 40.13% for female and 34.77% for male. The age group with the highest HBs Ab average was in their 40's (399.86 mIU/mL), while the lowest age group was in the 90's (211.50 mIU/mL). It is remarkable that the age group with the highest HBs Ab positive rate is in the 30's, and that teenagers (age group of 10-20 years) had the lowest positive rate. Especially 15, 18, 19 years old was statistically significant. Consideration should be given to determining the titer of vaccination and to clarify the timing of vaccination.

Human Epididymis Protein 4 Reference Intervals in a Multiethnic Asian Women Population

  • Mokhtar, N.M.;Thevarajah, M.;M.A., Noorazmi;M., Isahak
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6391-6395
    • /
    • 2012
  • Background: Ovarian cancer is ranked as the fifth most common cause of cancer death in women. In Malaysia, it is the fourth most common cancer in females. CA125 has been the tumor marker of choice in ovarian cancer but its diagnostic specificity in early stages is only 50%. Hence, there is a critical need to identify an alternative tumor marker that is capable of detecting detect ovarian cancer at an early stage. HE4 is a new tumor marker proposed for the early diagnosis of ovarian cancer and disease recurrence. Currently, none of the normal ranges of HE4 quoted in the literature are based on data for a multiethnic Asian population. Therefore, the aim of this study was to determine reference intervals for HE4 in an Asian population presenting in University Malaya Medical Centre, a tertiary reference hospital. Materials and Methods: 300 healthy women were recruited comprising 150 premenopausal and 150 postmenopausal women, aged from 20-76 years. All women were subjected to a pelvic ultrasonograph and were confirmed to be free from ovarian pathology on recruitment. Serum HE4 levels were determined by chemiluminescent microparticle immunoassay (CMIA, Abbott Architect). The reference intervals were determined following CLSI guidelines (C28-A2) using a non-parametric method. Results: The upper limits of the $95^{th}$ percentile reference interval (90%CI) for all the women collectively were 64.6 pmol/L, and 58.4 pmol/L for premenopausal) and 69.0 pmol/L for postmenopausal. The concentration of HE4 was noted to increase with age especially in women who were more than 50 years old. We also noted that our proposed reference limit was lower compared to the level given by manufacturer Abbott Architect HE4 kit insert (58.4 vs 70 pmol/L for premenopausal group and 69.0 vs 140 pmol/L in the postmenopausal group). The study also showed a significant difference in HE4 concentrations between ethnic groups (Malays and Indians). The levels of HE4 in Indians appeared higher than in Malays (p<0.05), while no significant differences were noted between the Malays and Chinese ethnic groups. Conclusions: More data are needed to establish a reference interval that will better represent the multiethnic Malaysian population. Probably a larger sampling size of equal representation of the Malay, Chinese, Indians as well as the other native ethnic communities will give us a greater confidence on whether genetics plays a role in reference interval determination.