• Title/Summary/Keyword: CM-wire

Search Result 255, Processing Time 0.034 seconds

Early Age Behavior of Thin Bonded Continuously Reinforced Concrete Overlay on Aged Jointed Plain Concrete Pavement (노후 줄눈 콘크리트 포장 보수를 위한 얇은 연속 철근 콘크리트 덧씌우기 포장의 초기거동 평가)

  • Ryu, Sung-Woo;Nam, Jung-Hee;Kim, Ki-Heun;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.121-132
    • /
    • 2009
  • Thin bonded continuously reinforced concrete overlay(CRCO) was constructed on He existing jointed plain concrete pavement(HCP) surface at Seo-Hae-Ahn express highway in South Korea in order to evaluate its applicability and performance. Two sections of road were considered for this evaluation. In the first section, the concrete overlayer was placed and cut down to the existing layer to form transverse joints while CRCO was constructed on top of the existing layer in the second section. Early strength concrete(Type III) was utilized for both overlay sections. The depth of milling and the thickness of overlaid layer were 5 cm and 10 cm, respectively. Several vibrating wire gauges(VWG) were installed to evaluate the performance of CRCO with respect to curling, delamination, and crack propagation. As a result of the strength test, it was found that strength of the material reaches the design criteria within 1-3 days. Analysis with vibrating wire gauge(VWG) showed CRCO effectively restricts joint movement. High adhesive strength also was observed from the material regardless of length of aging. Meanwhile, transverse cracks were observed on the middle of the section where JPCP overlay was applied whereas arbitrarily cracks in transverse direction were observed on the section where CRCP was applied.

  • PDF

3-D Analysis of Slope by Tension Wire Sensing (Tension Wire 계측을 통한 비탈면의 3차원 거동 분석)

  • Shin, Taeju;Kim, Taesoo;Hwang, Sanggoo;Han, Heuisoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.3
    • /
    • pp.41-48
    • /
    • 2015
  • Several sensor systems are used to estimate and predict the slope behaviors, however though slope sensing systems are much up-to-dated compared to before, they are mainly focused on the hardware developing. It means the analyzing software is deficient to apply the examining slope behavior for slope stability. In real case, slope behavior shows the 3-dimensional movement and failure; however the modeling methods for 3-D behavior are more difficult and need more variables. 1-D analysis shows only the length variation, however the real slope makes the 3-D behaviors. To fix the 3-D space coordinate, three values should be determined such as length, horizontal angle and vertical angle. Therefore if the 3-D coordinate system were composed by the points considered of two directions and length, the 3-D space could be separated into horizontal plane and vertical plane. The data from DY-slope in Chungbuk province was analyzed to the developed 3-D coordinate system. It is concluded from the results of 3-D analysis, the slope is generally moving to transverse direction, also the displacements are happening to road and vertical direction at the same time. Presently, the accumulated displacement between sensing points shows small value within 4.3 cm, and the displacements of all sensing points show the similar directions and magnitudes.

Electrochemical Deposition Characteristics of Ca2+ on Cu Wire Electrode in CaCl2 Molten Salt (CaCl2 용융염에서 Ca2+의 Cu 전극에 대한 전기화학적 증착 특성평가)

  • Hwang, Dong Wook;Lee, Jong Hyeon;Jeong, Sang Mun
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.175-183
    • /
    • 2022
  • With the expansion of the automobile market, the demand for Nd as an essential rare earth material for automobile motors is rapidly increasing. Research on the calcio-thermic reduction process between Nd2O3 and calcium-based alloys has been extensively studied in order to manufacture Nd. In this study, Ca-Cu, as a reducing for Nd2O3, was prepared by electrolysis in CaCl2 molten salt. Cu wire and graphite were employed as a working electrode and a counter electrode for electrolysis reaction, respectively. The reference electrode was manufactured by putting Ag wire in a mixture of AgCl and CaCl2 at a ratio of 1:99 mol%. The cyclic voltammetry results showed that the deposition of Ca2+ on the surface of working electrode was observed from a potential of -1.8 V, and the reduction potential of Ca2+ decreased as the reaction temperature increased. The diffusion coefficient of Ca2+ calculated by the chronoamperometry experiment was found to be 5.4(±6.8)×10-6 cm2/s. In addition, Ca-Cu liquid alloy was prepared by applying a constant potential to Cu electrodes. The element ratio of Ca-Cu alloy formed by applying a potential of -2.0 V was found to Ca:Cu=1:4.

Cu-Filling Behavior in TSV with Positions in Wafer Level (Wafer 레벨에서의 위치에 따른 TSV의 Cu 충전거동)

  • Lee, Soon-Jae;Jang, Young-Joo;Lee, Jun-Hyeong;Jung, Jae-Pil
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.91-96
    • /
    • 2014
  • Through silicon via (TSV) technology is to form a via hole in a silicon chip, and to stack the chips vertically for three-dimensional (3D) electronics packaging technology. This can reduce current path, power consumption and response time. In this study, Cu-filling substrate size was changed from Si-chip to a 4" wafer to investigate the behavior of Cu filling in wafer level. The electrolyte for Cu filling consisted of $CuSO_4$ $5H_2O$, $H_2SO_4$ and small amount of additives. The anode was Pt, and cathode was changed from $0.5{\times}0.5cm^2$ to 4" wafer. As experimental results, in the case of $5{\times}5cm^2$ Si chip, suitable distance of electrodes was 4cm having 100% filling ratio. The distance of 0~0.5 cm from current supplying location showed 100% filling ratio, and distance of 4.5~5 cm showed 95%. It was confirmed good TSV filling was achieved by plating for 2.5 hrs.

Effects of Dose and Image Quality according to Center Location in Lumbar Spine Lateral Radiography Using AEC Mode (자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향)

  • Jeong, Woon-Chan;Joo, Young-Cheol
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.85-90
    • /
    • 2021
  • The purpose of this study is to consider usefulness of using AEC mode and importance of patient center location in L-spine lateral radiography by comparing dose and image quality according to the change of patient center location with using AEC mode or not. In this study, guide wire is attached to the human body phantom's lumbar spine and the lead ruler is attached to the bottom of the wall detector to find out center location in detector. ESD, mAs, and EI were selected as dose factors, and image quality was compared through SNR. With the lumbar spine located center of the detector, dose factors and image quality were compared according to using AEC mode or not. Afterwards, phantom moved 4 cm and 8 cm back and forth and compared dose factors and image quality. The exposure parameters were 85 kVp, 320 mA, x-ray field size 10×17 inch, and the distance between the center X-ray and the detector was fixed at 100 cm. The center X-ray was perpendicular to the fourth lumbar spine and the only bottom AEC chamber was used. All data were analyzed by independent t-test and ANOVA. As a result of this study, with AEC when the center is matched, ESD was 1.31±0.01 mGy, without AEC was 2.12±0.01 mGy. SNR was shown to be 22.81±1.83, and 23.44±1.87 respectively. When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD were 1.09±0.004 mGy, 0.32±0.003 mGy, 1.19±0.017 mGy, 1.11±0.006 mGy respectively, SNR were 18.29±0.60 dB, 11.11±0.22 dB, 18.98±0.80 dB, 17.71±0.82 dB. Using AEC in L-spine lateral radiography reduced ESD by 38%, EI by 35%, and mAs by 38%, without any difference in SNR(p<0.05). When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD was decreasing each 16%, 75%, 9%, 15%, EI was decreasing each 14%, 77%, 15%, 20%, mAs was decreasing each 15% 75% 9%, 15%. SNR was decreasing each 19%, 51%, 17%, 22%.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Simulation of Signal Amplitudes and Signal-to-noise Ratios of $1^{st}$ order and $2^{nd}$ order Gradiometers with Various Baselines (다양한 기저선을 갖는 1차 및 2차 미분계의 신호크기 및 신호 대 잡음비 조사)

  • Kang, C.S.;Yu, K.K.;Lee, Y.H.;Kwon, H.;Kim, J.M.;Park, Y.K.;Lee, S.G.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.40-44
    • /
    • 2007
  • We investigated signal-to-noise ratios (SNRs) of magnetocardiography (MCG) signals using the first-order and the second-order gradiometers of different baselines. The MCG signals were recorded using a measurement system with 61 magnetometers which measured the normal magnetic component to the chest surface. The distance between the chest surface and the bottom of the dewar was changed from 0 cm to 15 cm, and the MCGs were measured for each distance. By subtracting the other signals (distance = 1 to 15 cm) from the reference signal (distance =0 cm), we could simulate the first-order and the second-order gradiometer signals with various baselines. In addition, to evaluate the reproducibility of the simulation, we fabricated the wire wound first-order and second-order gradiometers which measured a normal magnetic component to the chest surface. The baselines of the first-order gradiometers were, respectively, 50 mm, 70 mm and 100 mm and the baseline of the second-order gradiometer was 50 mm. Using these gradiometers, we recorded the MCG signal and compared the SNR between the simulation and the measurement.

  • PDF

Tuberculous Mediastinitis Developed After Surgical Treatment of Giant Chondrosarcoma on Chest Wall-one case report- (흉부 거대 연골육종의 외과적 치료후 발생한 결핵성 종격동염-1례 보고-)

  • 이재훈;양수호;김혁;정원상;김영학;이철범;강정호;지행옥
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.348-348
    • /
    • 1997
  • A 48 year old man, has been suffering from a growing chondrosarcoma of sternum which has deeply invading the anterior mediastinum: He underwent wide resection of the chest wall tumor including a 4 cm free margin of normal tissue on all portions. The tumor as 15 × 16× 10cm in size arising from sternum and include both proximal one third of the clavicle and the 1 st, 2nd, and 3rd coital cartilages. The resected skeletal defect in the anterior wall was very large after wide resection of the'tumor and reconstructed due to paradoxical chest wall movement with sandwich like method of double over lapping Marlex mesh and methylmethacreylate, and steel wires. The soft tissue reconstructive procedure was dont with myocutaneous flap transposition use of pectoralis muscle. But the patient go infected with tuberculosis in the mediastinum two months after the operation. We had removed all of previously inserted prosthetics and performed curettage and drainage. Recently we experienced a case with giant chondrosarcoma of the sternum associated with tuberculous mediastinitis. The patient had an uneventful postoperative course and was discharged with adjuvant treatment such as antituberculous medication for 1 year.

Tuberculous Mediastinitis Developed After Surgical Treatment of Giant Chondrosarcoma on Chest Wall -one case report (흉부 거대 연골육종의 외과적 치료후 발생한 결핵성 종격동염 -1례 보고)

  • 이재훈;양수호
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.248-252
    • /
    • 1997
  • A 48 year old man, has been suffering from a growing chondrosarcoma of sternum which has deeply invading the anterior mediastinum: He underwent wide resection of the chest wall tumor including a 4 cm free margin of normal tissue on all portions. The tumor as 15 $\times$ 16$\times$ 10cm in size arising from sternum and include both proximal one third of the clavicle and the 1 st, 2nd, and 3rd coital cartilages. The resected skeletal defect in the anterior wall was very large after wide resection of the'tumor and reconstructed due to paradoxical chest wall movement with sandwich like method of double over lapping Marlex mesh and methylmethacreylate, and steel wires. The soft tissue reconstructive procedure was dont with myocutaneous flap transposition use of pectoralis muscle. But the patient go infected with tuberculosis in the mediastinum two months after the operation. We had removed all of previously inserted prosthetics and performed curettage and drainage. Recently we experienced a case with giant chondrosarcoma of the sternum associated with tuberculous mediastinitis. The patient had an uneventful postoperative course and was discharged with adjuvant treatment such as antituberculous medication for 1 year.

  • PDF

Vertical Neutron Reflectometer at HANARO (하나로 수직형 중성자 반사율 측정장치)

  • Lee J.S.;Lee C.H.;Hong K.P.;Choi B.H.;Choi Y.H.;Kim Y.J.;Shin K.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.3
    • /
    • pp.132-137
    • /
    • 2005
  • Neutron reflectometer has been installed at HANARO, research reactor in Korea. It has vertical sample geometry and the wavelength of incident neutron beam is $2.459\;\AA$ Neutron fluxes at monochromator and sample position were $4.5\times10^9\;n/cm^2/sec,\;6.64\times10^6\;n/cm^2/sec4 those were measured by gold wire activation method. Also, some reference thin films such as d-PS, $SiO_2$ were measured and analyzedwith HANARO neutron reflectometer. As result of the work, it was certified that minimum reflectivity and available Q range were $10^{-6},\;and\;0.003\sim0.3\;\AA^{-1}$ respectively.