Body Stereotatic Radiosurgery Procedure of Base on Image Guided (Image Guided에 기초한 Body Stereotatic Radiosurgery의 과정)

  • Choi Yun-Kyeung;Lee Doo-Hyun;Cho Jung-Keun;Kim Jong-Won;Youm Doo-Seok;Kim Tae-Yoon;Choi Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.95-103
    • /
    • 2005
  • Purpose : In the radiosurgery, to obtain CT image to find more accurate tumor position during respiration, and using them, to increase the accuracy of radiation treatment by applying image guided. Materials and Methods : Using the self-made vacuum cushion for the body SRS, CT images were obtained three for each patient during respiration (shallow, inhalation, exhalation). They were transformed to the RTP computer and then were fused. Global GTVs were delineated on the fused images and more appropriated treatment planning was established. Results : We can find the tumor position is moving toward cranio-caudal with max 10 mm margin and volume is transformed. As a result from the comparision of DVH (pre & post radio surgery), we observed about 100% dose to tumor. Conclusion : BSRS was skeptical due to the tumor movement during respiration. More accurate by the combination of the development of immobilization devices and BSRS based on Image Guide, it will be applied to more cases for BSRS.

  • PDF

Improvement of lower hybrid current drive systems for high-power and long-pulse operation on EAST

  • M. Wang;L. Liu;L.M. Zhao;M.H. Li ;W.D. Ma;H.C. Hu ;Z.G. Wu;J.Q. Feng ;Y. Yang ;L. Zhu ;M. Chen ;T.A. Zhou;H. Jia;J. Zhang ;L. Cao ;L. Zhang ;R.R. Liang;B.J. Ding ;X.J. Zhang ;J.F. Shan;F.K. Liu ;A. Ekedahl ;M. Goniche ;J. Hillairet;L. Delpech
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4102-4110
    • /
    • 2022
  • Aiming at high-power and long-pulse operation up to 1000 s, some improvements have been made for both 2.45 GHz and 4.6 GHz lower hybrid (LH) systems during the recent 5 years. At first, the guard limiters of the LH antennas with graphite tiles were upgraded to tungsten, the most promising material for plasma facing components in nuclear fusion devices. These new guard limiters can operate at a peak power density of 12.9 MW/m2. Strong hot spots were usually observed on the old graphite limiters when 4.6 GHz system operated with power >2.0 MW [B. N. Wan et al., Nucl. Fusion 57 (2017) 102019], leading to a reduction of the maximum power capability. With the new limiters, 4.6 GHz LH system, the main current drive (CD) and electron heating tool for EAST, can be operated with power >2.5 MW routinely. Long-pulse operation up to 100 s with 4.6 GHz LH power of 2.4 MW was achieved in 2021 and the maximal temperature on the guard limiters measured by an infrared (IR) camera was about 540 ℃, much below the permissible value of tungsten material (~1200 ℃). A discharge with a duration of 1056 s was achieved and the 4.6 GHz LH energy injected into the plasma was up to 1.05 GJ. Secondly, the fully-active-multijunction (FAM) launcher of 2.45 GHz system was upgraded to a passive-active-multijunction (PAM), for which the density of optimum coupling was relatively low (below the cut-off value). Good coupling with reflection coefficient ~3% has been achieved with plasma-antenna distance up to 11 cm for the new PAM. Finally, in order to eliminate the effect of ion cyclotron range of frequencies (ICRF) wave on 4.6 GHz LH wave coupling, the location of the ICRF launcher was changed to a port that is located 157.5° toroidally from the 4.6 GHz LH system and is not magnetically connected.

Usefulness of Abdominal Compressor Using Stereotactic Body Radiotherapy with Hepatocellular Carcinoma Patients (토모테라피를 이용한 간암환자의 정위적 방사선치료시 복부압박장치의 유용성 평가)

  • Woo, Joong-Yeol;Kim, Joo-Ho;Kim, Joon-Won;Baek, Jong-Geal;Park, Kwang-Soon;Lee, Jong-Min;Son, Dong-Min;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.157-165
    • /
    • 2012
  • Purpose: We evaluated usefulness of abdominal compressor for stereotactic body radiotherapy (SBRT) with unresectable hepatocellular carcinoma (HCC) patients and hepato-biliary cancer and metastatic liver cancer patients. Materials and Methods: From November 2011 to March 2012, we selected HCC patients who gained reduction of diaphragm movement >1 cm through abdominal compressor (diaphragm control, elekta, sweden) for HT (Hi-Art Tomotherapy, USA). We got planning computed tomography (CT) images and 4 dimensional (4D) images through 4D CT (somatom sensation, siemens, germany). The gross tumor volume (GTV) included a gross tumor and margins considering tumor movement. The planning target volume (PTV) included a 5 to 7 mm safety margin around GTV. We classified patients into two groups according to distance between tumor and organs at risk (OAR, stomach, duodenum, bowel). Patients with the distance more than 1 cm are classified as the 1st group and they received SBRT of 4 or 5 fractions. Patients with the distance less than 1 cm are classified as the 2nd group and they received tomotherapy of 20 fractions. Megavoltage computed tomography (MVCT) were performed 4 or 10 fractions. When we verify a MVCT fusion considering priority to liver than bone-technique. We sent MVCT images to Mim_vista (Mimsoftware, ver .5.4. USA) and we re-delineated stomach, duodenum and bowel to bowel_organ and delineated liver. First, we analyzed MVCT images to check the setup variation. Second we compared dose difference between tumor and OAR based on adaptive dose through adaptive planning station and Mim_vista. Results: Average setup variation from MVCT was $-0.66{\pm}1.53$ mm (left-right) $0.39{\pm}4.17$ mm (superior-inferior), $0.71{\pm}1.74$ mm (anterior-posterior), $-0.18{\pm}0.30$ degrees (roll). 1st group ($d{\geq}1$) and 2nd group (d<1) were similar to setup variation. 1st group ($d{\geq}1$) of $V_{diff3%}$ (volume of 3% difference of dose) of GTV through adaptive planing station was $0.78{\pm}0.05%$, PTV was $9.97{\pm}3.62%$, $V_{diff5%}$ was GTV 0.0%, PTV was $2.9{\pm}0.95%$, maximum dose difference rate of bowel_organ was $-6.85{\pm}1.11%$. 2nd Group (d<1) GTV of $V_{diff3%}$ was $1.62{\pm}0.55%$, PTV was $8.61{\pm}2.01%$, $V_{diff5%}$ of GTV was 0.0%, PTV was $5.33{\pm}2.32%$, maximum dose difference rate of bowel_organ was $28.33{\pm}24.41%$. Conclusion: Despite we saw diaphragm movement more than 5 mm with flouroscopy after use an abdominal compressor, average setup_variation from MVCT was less than 5 mm. Therefore, we could estimate the range of setup_error within a 5 mm. Target's dose difference rate of 1st group ($d{\geq}1$) and 2nd group (d<1) were similar, while 1st group ($d{\geq}1$) and 2nd group (d<1)'s bowel_organ's maximum dose difference rate's maximum difference was more than 35%, 1st group ($d{\geq}1$)'s bowel_organ's maximum dose difference rate was smaller than 2nd group (d<1). When applicating SBRT to HCC, abdominal compressor is useful to control diaphragm movement in selected patients with more than 1 cm bowel_organ distance.

  • PDF

What are Legible Korean Font Sizes within In-Vehicle Information Systems?

  • Kim, Huhn;Park, Soo-Hyun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.397-406
    • /
    • 2012
  • Objective: The aim of this study is to determine legible Korean font sizes within in-vehicle information systems(IVISs) in diving conditions. Background: Font legibility within IVISs is one of important causes on its' safe operations during driving. Several researches proposed some guidelines on the legible English font sizes within IVISs. On the contrary, appropriate Korean font sizes have been hardly known in spite of the typological differences between English and Korean. Therefore, more systematic researches for improving the legibility on Korean font size within IVISs have been required. Method: In this study, an experiment was performed with the following experimental factors: the existence of vibration, the color contrasts(white on black, black on white), the font types(HDR, CubeR, Gothic), and the font sizes(6, 8, 10, 12, 14, 16, 18, 20, 22, 24pt). To fit the experimental conditions into real driving environments, the illuminance was controlled to 15lx by using LED lamp and the distance between IVIS and participants was kept to 70cm. Moreover, all participants took the shutter glasses for employing well-known occlusion techniques. Results: The experimental results showed that 'HDR' and 'Non-vibration + Black on white' group took the shortest response time, and decreasing slopes of the response time with increasing font sizes were slowing down at 14pt then flattened out at 22pt regardless of the existence of vibration and color contrasts. Conclusion: The minimum size for legible Korean font would be about 14pt(5.47mm) and the optimum size would be about 22pt(8.59mm). Application: The guideline on the Korean font sizes from this study will be applied to design an IVIS in the future.

Design and Fabrication of Signal and Power Transmission Textile Cable for Smart Wearables (스마트 웨어러블의 신호와 전력 전송용 섬유형 케이블 개발)

  • Lee, Hyewon;Im, Hyo bin;Roh, Jung-Sim
    • Fashion & Textile Research Journal
    • /
    • v.20 no.5
    • /
    • pp.616-620
    • /
    • 2018
  • Recently, many researches have been conducted to improve the performance and wearability of smart wearables. In this study, we designed and fabricated the signal and power transmission textile cables for smart wearables which have excellent wearability, durability and reliability. For the signal transmission textile cables, conductive yarns for the signal line and the ground line were developed. Three types of signal transmission textile cables have been developed using the conductive yarns. Linear density, tensile properties, electrical resistance and RF characteristics were tested to characterize the physical and electrical properties of three signal transmission textile cables. The conductive yarns have the very low resistance of $0.05{\Omega}/cm$ and showed excellent uniformity of electric resistance. Therefore, the electrical resistance of the signal transmission fiber cable can be reduced by increasing the number of conductive yarns used in signal and ground lines. However, the radio frequency (RF) characteristics of the signal transmission textile cables were better as the number of strands of the conductive yarns used was smaller. This is because the smaller the number of strands of conductive yarn used in signal transmission textile cables, the narrower and more parallel the distance between the signal line and the ground line. It is expected that the signal and power transmission textile cable for signal and power transmission will be utilized in smart wearable products.

Development of Schizogenous and Lysigenous Aerenchyma in Rice Root

  • Kang, Si-Yong;Wada, Tomikichi;Choi, Kwan-Sam
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.43 no.2
    • /
    • pp.77-82
    • /
    • 1998
  • Aerenchyma development in rice (Oryza sativa L.) roots is quite important for adaptation to waterlogged or reduced soil conditions. Anatomical observations were carried out to clarify the development of schizogenous and lysigenous aerenchyma in elongating crown roots of rice. The crown roots of 3rd and 4th phytomer were taken from rice plants of the 8th leaf stage grown by hydroponic culture. The schizogenous intercellular spaces in the cortex of crown root tip were observed using a light microscope with semi ultra-thin sections and the lysigenous aerenchyma in mature tissue of crown root were observed using a cryo scanning electron microscope (cryo-SEM) with freezing fracture method. The schizogenous intercellular spaces in the root tip exist obviously in the middle portion of cortical cell layers close to the root-root cap junction, but not in root cap, stele and outer cell layers of cortex. The air spaces were formed at the junction of four neighbouring cells of inner cortex in the transverse sections, and between longitudinal cell layer connected along the root axis. Although many of those spaces were filled with liquid, some spaces seem to exist as air spaces. The lysigenous aerenchyma in the cortex, which hardly filled with liquid, emerged at 3-4 cm segment from the root tip and increased toward the basal region of root axis. The developing process of lysigenous aerenchyma was primarily separation of a radial row of cells caused by the shrinking and collapsing of cortical cells and then formation of septa along the radial cell rows by the fusion of cell wall with each other. These results suggest that the schizogenous and lysigenous aerenchyma playa role as a passage for the movement of oxygen into the root tip region where oxygen is required for respiration.

  • PDF

A Study on the Development of Green Road System for Heat Energy Harvesting (녹색도로의 열 에너지 하베스팅을 위한 시스템 개발에 관한 연구)

  • Jo, Byung-Wan;Lee, Duk-Hee;Lee, Dong-Yoon;Lee, Chang-Sub
    • International Journal of Highway Engineering
    • /
    • v.13 no.1
    • /
    • pp.87-96
    • /
    • 2011
  • According to adverse effects of ecosystems due to a bulk of fossil fuel consumption, utilization of sustainable and renewable energy is required. In this paper, converting the energy crisis into an opportunity of new growth is expected by converting heat energy in asphalt pavement into electric power using thermoelectric effect. For this, experiments of inserting heat collector pipe and thermoelectric element into asphalt were performed, and the electric power of heat energy harvesting was measured for development of efficient harvesting system of heat energy. As the results of experiments, electric conversion of average 19.86W per day is possible at $1m^2$ conversion area at a depth of 5cm, and possibility of this system was confirmed. Consequently, a systematic "Green Road" using sustainable heat energy source in asphalt pavement simultaneously with environmental maintenance and econovic growth was suggested.

Isolated Congenital Alveolar Synechiae: Review of Literature and Case Report -A Case Report- (선천성 치조점막 유착에 대한 문헌고찰 및 증례보고 -증례보고-)

  • Kim, Soung-Min;Reddy, SG;Kim, Ji-Hyuck;Park, Young-Wook;Kwon, Kwang-Jun;Lee, Jong-Ho;Lee, Suk-Keun
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.7 no.1
    • /
    • pp.22-26
    • /
    • 2007
  • 상악과 하악이 선천적으로 붙어서 태어나는 선천성 유합증은 드문 선천성 기형으로 단순히 점막이 붙은 점막유합증에서 악골이 붙은 골유합증까지 다양하게 나타난다. 이중 상악골과 하악골의 골자체가 붙는 골유합증은 아주 드물어서 현재까지 26증례만 보고되고 있는데, 보고된 대부분의 증례는 편측에만 발생하는 불완전형으로 알려져 있다. 7세 된 여아환자가 인디아의 GSR 병원에 입이 벌어지지 않는다는 주소로 내원하였는데 환아의 턱은 완전히 움직이지 않았으며, 2-3 mm 정도 벌어지는 앞니부위에서는 2.5 cm 폭경의 3.0 mm 두께의 단단한 치조점막이 관찰되었다. 전기메스로 전방부의 부착성 섬유밴드를 잘라준 후 즉각적인 개구정도는 16 mm 정도까지 가능하여 구강으로의 기관삽관이 가능하였다. 삽관후 양쪽 후방부 협측점막의 두꺼운 밴드들을 모두 제거하여 개구량을 33 mm까지 증진시킨 후 수술을 종결하였다. 환아의 보호자에게 거즈 블록과 설압자를 이용하여 개구 연습을 능동적으로 시키도록 강조하여 교육하였으며 술후 16개월 경과시까지 특별한 합병증이나 개구량 감소는 관찰되지 않았다. 독립적으로 발생한 선천성 치조점막 유합증 환자에서 비정상적으로 커져있는 과두와 설골이 관찰되었는데, 설-하악 구조의 비정상적인 발육에 기인하여 지속적인 비정상적 운동으로 인한 이차적인 치은과 협점막의 섬유성 부착이 생긴 것으로 추측되었다. 이에 마취과와의 효율적인 협진으로 기관절개술 등의 부가적인 마취방법 없이 효과적으로 치료할 수 있었다.

  • PDF

Long-Term Result of the Epiphyseal Transplantation in Distal Forearm (전완원위부 변형에 대한 혈관부착 성장판 이식술)

  • Chung, Duke-Whan;Han, Chung-Soo;Yoo, Myung-Chul;Han, Soo-Hong
    • Archives of Reconstructive Microsurgery
    • /
    • v.4 no.1
    • /
    • pp.16-22
    • /
    • 1995
  • We analyzed 11 children who underwent epiphyseal transplantation to the forearm for manage growing deformity ranged from 2 years 6 months to years(average 5 years 10 months) follow-up period. Etiologies of the functional impairment of the eleven were five traumatic, three congenital and three tumorous conditions. Lesions of epiphysis were distal radius in eight patients and distal ulna in three patients. Operation was performed with removal of non-functioning or deformed epiphysis followed by transplantation of free vascularized proximal fibular epiphysis with microvascular anastomesis. Evaluation was performed radiologically and functionally. The 9(81.8%) patients showed growth of transplanted epiphysis by radiological examination during follow up. At the last follow up, average growth rate was 0.86cm per year excepts 2 cases of no growth. Active wrist motion near normal to contralateral joint was achieved in 7 patients. In other 2 patients, active joint motion was improved but weaker than contralateral joint. Complications on donor site were two transient peroneal nerve palsy which have been resolved after 2 and 5 months post operation and one valgus ankle deformity. The ankle deformity was corrected with $Langenski\"{o}ld$ operation of the dital tibiofibular fusion. At recipient site, there was one superficial infection and it was easily controlled by systemic antibiotics. Many subsequent reports have described successful nonvascularized epiphyseal transplante, but overall results have been inconsistent and unsatisfactory. Other experimental and clinical studies in the transfer of vascularized epiphyses has encourage its clinical application. We also could gel successful growth in several cases with free vascularized epiphyseal transplantation.

  • PDF

Studies on the Improvement of Butt Welding Characteristic of Polyethylene Pipes (PE 이중벽관의 맞대기 융착 용접 강도 향상에 관한 연구)

  • An, Ju-Seon;Lee, Kyng-Won;Kim, Jae-Sung;Lee, Bo-Young
    • Journal of Welding and Joining
    • /
    • v.29 no.1
    • /
    • pp.85-89
    • /
    • 2011
  • Waste water is disposed to sewage disposal plant by underground PE double wall pipes. Various processes have been introduced to join PE pipes, but most of these methods have many disadvantages such as costs, lack of reliability and difficulties in joining, etc. Recently butt welding has been paid much attention to joint PE pipes as this process has many advantages such as cost, safety and reliability. In this study, newly developed heat plate, a patent-pending heat plate with a groove, was used to butt-weld PE double wall pipes with different misalignment gaps to simulate real underground conditions, and the butt welding temperature of PE pipe was determined by thermal analysis (Thermal Gravimetric Analysis, Differential Scanning Calorimetry and Dynamic Mechanical Analysis). The resulting joining characteristics of double wall pipes were compared with those from a conventional heat plate, in terms of stiffness, flattening and leakage tests. The results from the stiffness and flattening test showed that there were no big differences between the butt-welded joints made from these two plates. From the leakage test, although PE pipes welded with a conventional heat plate did leak below the required test conditions (10 min. at 0.75kgf/cm2), the pipes welded with a patent-pending grooved heat plate did not show any leakage even at a pressure 1.5 times higher than the required conditions. It was noted that by utilizing a grooved heat plate more complete fusion at the pipe joints could be obtained, which in turn induced a high quality joints.