• Title/Summary/Keyword: CM Trend

Search Result 417, Processing Time 0.022 seconds

Weight, Eating Habits and Dietary Self-efficacy of Middle School Girls with Eating Disorder (섭식장애 위험군 여중생의 체중, 식습관과 식이자아효능감)

  • Rhie, Hyo-Jung;Lee, Seung-Gyo;Won, Hyang-Rye
    • The Korean Journal of Community Living Science
    • /
    • v.19 no.2
    • /
    • pp.283-295
    • /
    • 2008
  • The slimness favored trend made students shape up body image by weight control using restrained eating. Many students especially female ones tend to be in eating disorder status. The aim of this study was to find the relation between weight, eating habits and dietary self efficacy in the selected middle school girl students group with high risk eating disorder (7.9%) and the one with low risk eating disorder (24.1%). This study was conducted by EAT-26 questionnaire method and all the data was analyzed by SAS (Statistical Analysis System) program. The results were as follows; The physical condition of eating disorder students (159.5cm height, 50.7kg weight and 97.4% PIBW) was higher and bigger than that of normal students(158.2 cm, 47.2 kg, and 92.6% PIBW). Weight control experience in the high risk group (69.4%) was significantly more frequent than normal group (p<0.001). The gap between actual body weight and desired weight was higher in high risk eating disorder group than in normal group (p<0.001). Dietary self-efficacy score of middle school female students in the high risk eating disorder group was high when they were in temper, in confusion, and after argument. However, when they were in cooking (p<0.01), with friends (p<0.05), in assembling dishes (p<0.01), and with family (p<0.05) the dietary self-efficacy score of high risk group was lower than that of normal group. In the high risk eating disorder group, eating speed was often faster (p<0.05) and overeating rate (p<0.01) was higher than in normal group. In general, EAT-26 score was correlated positively with gap weight, but negatively correlated with dietary self efficacy score(p<0.01). Gap weight and dietary self efficacy were significantly different in normal group. however, there was no relation in high risk eating disorder group. Under the circumstance of high risk eating disorder, as weight and dietary self efficacy did not affect the relation with eating disorder score, when it is determined as eating disorder some other factors besides weight and diet self efficacy seem to affect the eating disorder score. In conclusion, the factors related with eating disorder were gap weight and some items of dietary self efficacy. Thus, correct understanding of healthy weight and dietary self efficacy enhancement require the development of nutrition education contents and the practice of nutrition education.

  • PDF

The Study of Dietary Behavior, BMI and Nutrient Intake Status in Middle School Students of Daegu Area (대구 일부 지역 중학생의 식행동ㆍ체질량지수와 영양소 섭취상태에 관한 연구)

  • Jeong Kwey-Young;Lee Young-Soon;Kim Sung-Mee
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.15 no.1
    • /
    • pp.1-10
    • /
    • 2005
  • Dietary behavior, body mass index(BMI) and nutrient intake status of 185 boys and 205 girls in 3rd grade middle school students in Daegu area were analyzed. Boys were 168.6cm tall and weighed 61.3kg on the average and girls 158.5cm and 54.4kg, respectively. From their BMIs, 17.9% were classified as the underweight, 54.2% as the average, 14.7% as the overweight and 13.2% as the obesity. The average energy intake per day was 2222.6 kcal for boys, 1796.2 kcal for girls which were 83.3% and 86.6% of the RDA, respectively. Composition rate of carbohydrate, protein, fat in relation to energy intake was 62.4 : 16.5 : 21.1 for boys and 58.8 : 16.0 : 25.2 for girls. Protein was taken low and carbohydrate and fat were high in this study. Particularly, fat intake rate of girls was high. Calcium, iron, vitamin A, and vitamin B2 did not meet the RDA and especially calcium was taken 63.9% for boys and 54.01 % for girls. Most of the students have tendency to eat irregularly and to overeat. For the nutrients intake, calories and calcium intake were lower than the RDA regardless of gender and iron intake was not enough for girls only. In relation to BMI, obesity group students were taking lower calories and proteins than the normal students were. No consistent trend was shown for boys about nutrient intake in relation to eating speed. Students had a correct perception of their body image which was similar to that of their mothers. Nutrient average intake is under the average and the percentile under 70% of RDA was high contrary to the fact that nutrient intake like calcium and iron was exceedingly important particularly in the growth process. Therefore, nutritional education for the proper intake of nutrients was required for the students in Daegu area. Especially, education has to be focused on the balanced diet and correct food choices for the proper dietary behaviors.

  • PDF

A Study on Poisoning of the Reforming Catalysts on the Position of Anode in the Direct Internal Reforming Molten Carbonate Fuel Cell (직접 내부개질형 용융탄산염 연료전지의 음극판 위치에 따른 개질 촉매 피독에 관한 연구)

  • Wee, Jung Ho;Chun, Hai Soo
    • Applied Chemistry for Engineering
    • /
    • v.10 no.5
    • /
    • pp.652-659
    • /
    • 1999
  • The trend of poisoning of reforming catalyst along with the position of anodic catalyst bed was studied. Keeping the conditions that steam to carbon ratio was 2.5, operating voltage was 0.75 V, current density was $140mA/cm^2$, the unit cell was operated during 24 hrs at a steady state. And then the cell was stopped, the catalysts packed in the position of inlet, middle and outlet were sampled individually and then the amount of carbon, Li and K poisoned were analysed. After 100 hrs operated, the catalysts at the same positions were analysed at the same manner. The result of this experiment was as followings. After 24 hrs operated, the poisoning amounts of Li and K in the catalyst were 0.27 wt% at inlet, 0.23 wt% at middle and the highest value 1.59 wt% at outlet. After 100 hrs, the amount of poisoning is the highest in the catalyst packed at the inlet of unit cell. The performance simulation of unit cell explained these trends of poisoning catalysts. The simulation told that the catalyst in the region of the inlet of unit cell treated the 90% of initial methane flow rate and the highest electrochemical reaction happened in this region. So the catalysts of this region were the most poisoned with carbon, Li and K and also the rate of poisoning is faster than that of the catalyst at other regions. The temperature at the region of outlet of unit cell was $30^{\circ}C$ higher than that of other regions, so more Li, and K vaporized than at other regions and little reforming reaction at this region made the catalysts poisoning rate low.

  • PDF

Application of an imaging plate to relative dosimetry of clinical x-ray beams (Imaging Plate를 이용한 의료용 광자선의 선량측정)

  • 임상욱;여인환;김대용;안용찬;허승재;윤병수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2000
  • The IP(imaging plate) has been widely used to measure the two-dimensional distribution of incident radiation since it has a high sensitivity, reusability, a wide dynamic range, a high position resolution. Particularly, the easiness of acquiring digitized image using IP poses a strong merit because recent trend of data handling prefers image digitization. In order to test its usefulness in photon beam dosimetry, we measured the off-axis ratio(OAR) on portal planes and percent depth dose(PDD) within a phantom using IP, and compared the results with the data based on EGS4 Monte Carlo particle transport code, ion-chambers, conventional films. For the measurement, we used 6 MV X-rays, various field sizes. As a result, IP showed significant deviation from ion-chamber measurement: a significant overresponse, 100% greater than that of ion-chamber measurement at deep part of the phantom. Filtration of low-energy scattered photons at deep part of the phantom using 0.5 mm thick lead sheets did improve the result, only to the unacceptable extent. However, portal dose measurement showed possibilities of If as a dosimeter by showing errors less than 5%, as compared with film measurement.

  • PDF

Thickness Dependence of Electrical and Optical Properties of ITZO (In-Sn-Zn-O) Thin Films (ITZO (In-Sn-Zn-O) 박막의 전기적 및 광학적 특성의 두께 의존성)

  • Kang, Seong-Jun;Joung, Yang-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.7
    • /
    • pp.1285-1290
    • /
    • 2017
  • We prepared ITZO thin films with various thicknesses on glass substrates using RF magnetron sputtering and investigated electrical, optical and structural properties of the thin film. Sheet resistance of ITZO thin film showed a decreasing trend on the increase of film thickness, but its resistivity exhibited a substantially constant value of $5.06{\pm}1.23{\times}10^{-4}{\Omega}-cm$. Transmittance of ITZO thin film moved to the long-wavelength with the increase of film thickness. Figure of merit in a visible light and an absorption area of P3HT:PCBM organic active layer of the 360nm-thick IZTO thin film was $8.21{\times}10^{-3}{\Omega}^{-1}$ and $9.29{\times}10^{-3}{\Omega}^{-1}$, respectively. Through XRD and AFM measurements, it was confirmed that all the ITZO thin films have amorphous structure and the surface roughness of films are very smooth in the range of 0.561 to 0.263 nm. In this study, it was found that amorphous ITZO thin film is a very promising material for organic solar cell.

Practicability Assessment of Spherical Mechanical Check Device(SMCD) (Mechanical Check용 Spherical device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Yang, Dae-Sik;Kweon, Young-Ho;Ko, Shin-Gwan;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and radiation treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation treatment field. In order to accommodate the current trend of digital from analog, a spherical mechanical check device(SMCD) that is the form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. If the distance maintains constance between source(target) and image detector with constant distance to the center of spherical mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. In addition, it has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

Practicability Assessment of Spherical Type Mechanical Check Device (SMCD) (Mechanical Check용 Spherical Device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Kim, Gun-Oh;Kweon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.55-62
    • /
    • 2007
  • Purpose: Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and medical treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation therapy area. In order to accommodate the current trend of digital from analog, a spherical type mechanical check device (SMCD) that is form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. Materials and Methods: If the distance maintains constant between source(target) and image detector with constant distance to the center of spherical type mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. Results: It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. Conclusion: It has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

Design Preference & Consumer Trend of Younger Children's Parents for Smart Animal Toy (영유아 부모의 동물형 스마트 토이 디자인 선호도 및 구매요인)

  • Hyun, Eunja;Yoon, Hyunmin
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.72-83
    • /
    • 2015
  • The purpose of this study was firstly, to explore the design preference, consumer experience and purchasing factors of parents for smart animal toys and secondly, investigate whether there is a difference by children's sex and age. For this purpose, the questionnaire survey was conducted with 344 parents of younger children in Seoul and Gyeonggi Province. As a result, the white or brown colored 20~30cm, dog-type smart toy was preferred and the sound was considered as the most important function. Besides role of toy, smart toy was expected to play as a pet, a friend and a younger sibling. Actually, dog-type smart toy were most frequently purchased. And main satisfied causes were fun, interactivity and design and dissatisfied causes were noise, price, battery life and durability of purchased smart toys. Finally, the important factors in purchasing smart toy were the safety, durability, battery life, sustainable play, education and washability. The parents' preference, customer experience and purchasing factors showed little significant differences according to the sex and the age of the children. This research will be useful in understanding parents purchasing activity of smart animal toys and provide valuable data for function construction, design and service planning necessary to develop the smart animal toy.

A Study on the Fatigue Failure Behavior of Cheon-Ho Mt. Limestone Under Cyclic Loading (천호산 석회암의 반복하중에 의한 피로파괴거동에 관한 연구)

  • Lee, Jong-Uk;Rhee, Chan-Goo;Kim, Il-Jung;Kim, Yeong-Seok
    • Nuclear Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.98-109
    • /
    • 1992
  • In this study uniaxial cyclic loading tests were performed on Cheon-Ho Mt. Limestone specimens to investigate the fatigue failure behavior. The loading rate was kept constantly at 760kg/$\textrm{cm}^2$/sec under cyclic loading. In order to reveal the fatigue behavior for each rock type, the test results were mutually compared with previous studies carried out on Indiana Limes-tone and Seong-Ju Sandstone. Fatigue data is presented in the form of S-N curves, which illustrate the relationship of maximum applied stress(S) to the number of cycles(N) required to produce failure. For the purpose of comparing the S-N curves for each rock type, the test data were formulated up to 10$^4$cycles and the correlation coefficients(R) on Cheon-Ho Mt. Limestone and Seong-Ju Sandstone specimen are 0.886 and 0.983, respectively. All three rock specimens were found to have shorter fatigue life at higher applied stress levels. The fatigue life for each rock type was considered as no less than 81.5, 70 and 74.8%, for Cheon-Ho Mt. Limestone, Indiana Limestone and Seong-Ju Sandstone, respectively. The comparison in static strength for monotonic loaded specimens and specimens which did not fail even after 10$^4$cycles indicated that the increasing rate of strength was about 6.18 and 10.96% , for Cheon-Ho Mt. Limestone and Indiana Limestone, respectively. Poisson's ratio and volumetric strain for Cheon-Ho Mt. Limestone and Seong-ju Sandstone, tended in all the cases to rapidly increase at higher stress levels and with an increase in number of cycles. This increasing trend becomes rapid and obvious just before failure. Also Poisson's ratio and volumetric strain for each stress level were compared and analyzed at the first cycle and the cycle prior to failure.

  • PDF

Flowability and Strength Properties of Mortar and Self-Compacting Concrete Mixed with Waste Concrete Powder (폐콘크리트 분말을 혼합한 모르타르 및 자기충전 콘크리트의 유동 및 강도특성)

  • Choi, Yun-Wang;Jung, Moon-Young;Moon, Dae-Joong;Kim, Sung-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.517-526
    • /
    • 2006
  • In this study, in order to utilize waste concrete powder(WCP) which is occurred in manufacturing high quality recycled aggregate as an admixture for self-compacting concrete(SCC), the properties of cement paste, mortar, and concrete that were mixed two types of WCP, 928 and 1,360 $cm^2/g$ of surface area, were analyzed. As a result of experiment, we have found that WCP was a porous material with angle. When WCP was utilized as an admixture for SCC, its flowability and viscosity increased in proportion to the increase of a replacement ratio, and that a replacement ratio of WCP was proper within 15%. The compressive strength at 28 days mixed respectively with WCP2, 15 and 30%, showed about 36 and 28 MPa, and it showed a similar trend with a function suggested in CEB-FIP for the relationship of compressive strength and elastic modulus. According to the results, it is judged that WCP2 can be utilized as an mineral admixture of normal strength SCC.