• Title/Summary/Keyword: CLEARANCE

Search Result 2,376, Processing Time 0.028 seconds

The Separation of the Vane and the Camring at high speed of an Oil Hydraulic Vane Pump for Automobile (자동차용 유압베인펌프의 고속에서 베인과 캠링간의 이간현상)

  • Cho, Ihn-Sung;Baek, Il-Hyun;Jung, Jae-Youn
    • Tribology and Lubricants
    • /
    • v.26 no.2
    • /
    • pp.136-141
    • /
    • 2010
  • In an oil hydraulic vane pump for an automobile, it is very important that the vane doesn't separate from the camring inner race during the operation of the vane pump. The vane generally has not only the oil hydraulic force acting on the bottom face to contact to camring inner race but there is also an inertial force and viscous force. Because the oil hydraulic force is much larger than the other forces, the contact state between the vane tip and the camring inner race is sufficient. However, the contact state between the vane tip and the camring inner race is only affected by the inertial and viscous forces during the delivery of the vane pump, because the oil hydraulic force acting on the vane is in equilibrium. If the inertial force is larger than the viscous force, which happens when the vane is separated from the camring inner race, the delivery of the vane pump can become unstable or the volume efficiency can become decrease rapidly. Therefore, in this paper, the state of the contact between the vane and the camring is considered. The results show that the rotating speed of the shaft, the operating temperature of the oil, the clearance between the vane and the rotor, and the mass of the vane exert a great influence on the state of the contact between the vane and the camring.

Performance Predictions of Gas Foil Bearing with Leaf Foils Supported on Bumps (범프로 지지되는 다엽 포일을 갖는 가스 포일 베어링의 성능 해석)

  • Kim, T.H.;Mun, H.W.
    • Tribology and Lubricants
    • /
    • v.34 no.3
    • /
    • pp.75-83
    • /
    • 2018
  • Microturbomachinery (< 250 kW) using gas foil bearings can function without oil lubricants, simplify rotor-bearing systems, and demonstrate excellent rotordynamic stability at high speeds. State-of-the-art technologies generally use bump foil bearings or leaf foil bearings due to the specific advantages of each of the two types. Although these two types of bearings have been studied extensively, there are very few studies on leaf-bump foil bearings, which are a combination of the two aforementioned bearings. In this work, we illustrate a simple mathematical model of the leaf-bump foil bearing with leaf foils supported on bumps, and predict its static and dynamic performances. The analysis uses the simple elastic model for bumps that was previously developed and verified using experimental data, adds a leaf foil model, and solves the Reynolds equation for isothermal, isoviscous, and ideal gas fluid flow. The model predicts that the drag torques of the leaf-bump foil bearings are not affected significantly by static load and bearing clearance. Due to the preload effect of the leaf foils, rotor spinning, even under null static load, generates significant hydrodynamic pressure with its peak near the trailing edge of each leaf foil. A parametric study reveals that, while the journal eccentricity and minimum film thickness decrease, the drag torque, direct stiffness, and direct damping increase with increasing bump stiffness. The journal attitude angle and cross-coupled stiffness remain nearly constant with increasing bump stiffness. Interestingly, they are significantly smaller compared to the corresponding values obtained for bump foil bearings, thus, implying favorable rotor stability performance.

Detection of urinary trypsinogen-2 for diagnosis of canine acute pancreatitis (뇨중 trypsinogen-2 검출을 이용한 개의 급성 췌장염 진단)

  • Han, Hong-ryul;Hwang, Cheol-yong;Pak, Son-il;Oh, Tae-ho
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.5
    • /
    • pp.951-960
    • /
    • 1999
  • We performed this study to evaluate the potential clinical marker of urinary trypsinogen-2 together with amylase, lipase and urinary amylase creatinine clearance ratio (ACCR) for the diagnosis of acute pancreatitis in dogs. In the experiment on daily changing patterns of amylase, lipase and ACCR measurements in experimentally induced pancreatitis dogs, compared to values measured in pre-induction state, significant difference was seen in amylase until 5th day of induction, and for lipase significant difference was found during the 7th day of observation period (p < 0.05). No significant difference was found in ACCR for the study period (p > 0.05). On SDS-PAGE analysis of urine from experimentally induced pancreatitis dog, The 26kd band was markedly increased compared with that of normal state and that band was confirmed trypsinogen-2 using substrate interaction and isoelectric focusing assay after being eluted. When assessing the appearance of 26kd band on urine SDS-PAGE 87.1% (range: 50~100%) of experimentally induced pancreatitis dogs showed positive results, whereas no corresponding band was seen in dog without pancreatic disorders. With this result, determination of urinary trypsinogen-2 assay was found to have a high diagnostic value with a 70% of sensitivity and 100% of specificity as a routine test for pancreatitis, although the detection of trypsinogen-2 in urine can be varied on the progression stage of pancreatitis at the initial visit to animal clinic. We therefore suggest that the promising results in this study be used for the development of dipstick test for detecting acute pancreatitis in the future research.

  • PDF

Biomechanical Analysis of Take-Off Techniques of Women's High Jump Winners at IAAF World Championships, Daegu 2011 (세계일류여자높이뛰기선수의 발구름 기술에 대한 바이오메카닉스적 분석)

  • Bae, Young-Sang;Kim, Eui-Hwan;KIm, Ki-Man;Lee, Jeong-Min;Kim, Sung-Sup;Kwon, Moon-Seok;Wi, Ung-Ryang
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.5
    • /
    • pp.585-593
    • /
    • 2011
  • The purpose of this study was to analyze, from a kinematical point of view, the high jump techniques of three women's high jump winners at the IAAF World Championships, Daegu 2011. The trends for the techniques of the world's top high jumpers were examined, with a view toward adapting these techniques to the physical characteristics of Korean women's high jumpers. It was valuable that Di Martino, who was the shortest in height, was able to win a medal by using a single arm swing take-off technique, along with a half flexed leading leg swing to attain a deep arch and clear the bar. This showed that the world's top athletes used jumping techniques with no decrease in the run-up velocity at the take-off. Furthermore, It appeared that the knee joint angle at take-off had a direct effect on the body position at take-off (H1).

Kinematic Analyses of Women's Pole Vault in IAAF World Championships, Daegu 2011 (2011 대구 세계육상선수권대회 여자 장대높이뛰기경기 기술의 운동학적 분석)

  • Choi, Kyoo-Jeong;Yi, Kyung-Ok;Kim, Nam-Hee;Kang, Ji-Eun;Kim, Hye-Lim
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.5
    • /
    • pp.561-571
    • /
    • 2011
  • The purpose of this study was to perform the kinematic analyses of the women's pole vault skills in IAAF World Championships Daegu 2011. Subjects were the 1st through 8th place finishers in the pole vault. The kinematic analyses were divided into four phases: two dimensional run up analysis, and three dimensional analyses for the remaining plant, swing up, and extension phases. Run-up variables consisted of run up distance, number of steps, average step length, ratio of step length to height, average velocity at the final 5~10 m, approach position. Three variables were analyzed during plant: pole angle, center of gravity (COG) velocity, and COG takeoff angle. Swing up phase variables included: pole flection angle, COG velocity (horizontal, vertical, resultant), COG trajectory and bar approach angle of COG. Compared to the 2009 World Championships in Berlin, the average vault height increased, while run up velocity and approach position were almost unchanged. However, horizontal velocity during the last two steps of the final approach decreased noticeably compared to speeds from 1990. These results reflect the change in both technique and physical fitness in pole vaulters. During extension, the peak height of COG surpassed the clearance height by an average of 0.11m. These specific results can help coaches and athletes modify training and improve performance.

Kinematic Analysis of Hurdle Clearance Technique for 110-m Men's Hurdlers at IAAF World Championships, Daegue 2011 (2011 대구세계육상선수권대회 110m 허들 선수의 허들링 기술 동작의 운동학적 분석)

  • Park, Young-Jin;Ryu, Jae-Kyun;Ryu, Ji-Seon;Kim, Tae-Sam;Hwang, Won-Seob;Park, Sang-Kyoon;Yoon, Suk-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.5
    • /
    • pp.529-540
    • /
    • 2011
  • The purpose of this study was to evaluate the kinematic characteristics of $5^{th}$ and $6^{th}$ hurdle clearances during the final of the 110-m hurdles at the IAAF World Championships, Daegu 2011. To this end, the hurdling motions of the top 4 ranked male hurdlers in the competition were analyzed. A total of 12 cameras were used to record their motions, with a sampling frequency of 120 Hz. The cameras were calibrated using $11{\times}2{\times}1\;m$ control objects that covered all of the lanes (1st~8th lanes). After analyzing all the data, we arrived at the following results. In the take-off phase, all athletes revealed similar take-off times (CT), and similar distances from the take-off to hurdleto (L1) and hurdle to landing (L2). In particular, Turner, ranked $3^{rd}$, had an inconsistent L2 and may need further training to correct it. In the flight phase, Richardson, ranked $1^{st}$, showed the longest flight distance, whereas Xiang, who was ranked $2^{nd}$, showed the highest CG height from the hurdle. For the step patterns, to increase the pitch frequency, Richardson and Xiang used shorter 3-step lengths than Turner and Oliver.

The Study on Vancomycin Pharmacokinetics and Dosing Guideline in Korean Neonates (한국 신생아에서의 Vancomycin 약동학과 Dosing Guideline에 대한 연구)

  • Choi, Sung Joo;Suh, Okkyung;Lee, Suk Hyang;Shin, Hyun Taek;Ro, Hwan Seong;Pi, Soo-Young
    • Korean Journal of Clinical Pharmacy
    • /
    • v.6 no.2
    • /
    • pp.7-13
    • /
    • 1996
  • The purposes of this study were to define the pharmacokinetic parameters of vancomycin in Korean neonates, to evaluate current neonatal vancomycin dosing guideline being used in a teaching hospital, and to develop the optimal vancomycin dosing guideline. The evaluation of 35 sets of peak and trough concentrations drawn on current dosing regimen showed that $29\%$ of peak concentrations and $46\%$ of though concentrations were within therapeutic range. Otherwise, pharmacokinetic parameters, based on 62 sets of peak and trough serum concentrations obtained from 39 neonates, showed that mean vancomycin clearance (CL), volume of distribution (Vd), and terminal elimination half-life were $0.13\pm0.08\;L/hr,\;0.94\pm0.48\;L,\;and\;5.6\pm2.13$ hours, respectively. Volume of distribution (Vd) normalized for body weight remained constant throughout PCA range, whereas the absolute CL (r=0.74) and normalized CL (r=0.36) showed high correlation with PCA. Also, the normalized CL showed a strong inverse correlation (r=-0.55) with serum creatinine concentrations (SrCr). Based on the high correlation among PCA serum creatinine concentration, CL, and the daily dosage requirements, the following dosing guideline for vancomycin in neonates was suggested: 10 mg/kg $12{\sim}18$ hourly for < 30 weeks PCA and < 0.6 mg/dl SrCr; 10 mg/kg 18 hourly for < 30 weeks PCA and $0.6{\sim}1.2$ mg/dl SrCr; 10 mg/kg 8 hourly for $30\sim44$ weeks PCA and < 0.6 mg/dl SrCr; 10 mg/kg 12 hourly for $30\sim44$ weeks PCA and $0.6{\sim}1.2$ mg/dl SrCr.

  • PDF

Studies of Valve Lifter for Automotive Heavy Duty Diesel Engine by Ceramic Materials I. Developmet of Ceramic-Metal Joint by Brazing Method (Ceramic 재질을 이용한 자동차용 대형 디젤 엔진 Valve Lifter 연구 I. Brazing Process에 의한 Ceramic-Metal 접합체 개발)

  • 윤호욱;한인섭;임연수;정윤중
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.2
    • /
    • pp.163-171
    • /
    • 1998
  • Continuously contacting with camshaft the face of Valve Lifter made of cast iron brings about abnormal wear such as unfairwear or earlywear because it is heavily loaded in the valve train systems as the engine gets more powered. This abnormal wear becomes a defet namely over-clearance when the valve is lifting so that the fuel gas imperfectly combusted by unsuitable open or close aaction of the engine valve in the combustion chamber. The imperfect combustion in the end results in the major cause of air pollution and combustion chamber. The imperfectly combusted by unsuitable open or close action of the engine valve in the combustion chamber. The imperfect combustion in the end results in the major causes of air pollution and decrease of the engine output. Consequently to prevent this wear this study was to develop the valve lifter which is joined by brazing process with SCM435H and a tip by manufacturing the face as a superhardened which is joined by brazing process with SCM435H and a tip by manufacturing the face as a superhardened ceramics alloy which has high wear resistance. Having the excellent surface hardness with Hv1100-1200 the sintered body developed with superhardened alloy(WC) can endure the severe face loading in the valve train system. We experienced with various brazing alloys and obtained the excellent joining strength to the joint had 150MPa shear strength. Interface analysis and microstructure in a joint were examined through SEM & EDS Optical microscope. Also 2,500 hours high speed(3,000-4,000 rpm) and continuous (1step 12hr) engine dynamo testing was carried out to casting valve liter and ceramics-metal joint valve lifter so that the abnormal wears were compared and evaluated.

  • PDF

Studies of Valve Lifer for Automotive Heavy Duty Diesel Engine by Ceramic Materials II. Development of SiC Valve Lifter by Injection Molding Method (Ceramic 재질을 이용한 자동차용 대형 디젤엔진 Valve Lifter 연구 II. 사출성형에 의한 탄화규소질 Valve Lifter 개발)

  • 윤호욱;한인섭;임연수;정윤중
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.2
    • /
    • pp.172-179
    • /
    • 1998
  • Valve lifter namely tappet is supported by lifter hole which is located upper side of camshaft in cylinder block transforms rotatic mvement of camshaft into linear movement and helps to open and shut the en-gine valve as an engine parts. The face of valve lifter which is continuously contacting with camshaft brings about abnormal wears such as unfair wear and early wear because it is severely loaded in the valve train system. These wears act as a defect like over-clearance and cause imperfect combustion of fuel during the valve lifting in the combustion chamber. Consequently this imperfect combustion makes the engine out-put decrease and has cause on air pollution. To prevent these wears therefore The valve lifter cast in me-tal developed into SiC ceramics valve lifter which has an excellence in wear and impact resistance As a results the optimum process conditions like injection condition mixture ratio and debonding process could be established. After sintering fine-sinered dual microstructure in which prior ${\alpha}$-SiC matches well with new SiC(${\beta}$-SiC) produced by reaction among the ${\alpha}$-SiC carbon and silicon was obtained. Based on the study it is verified that mechanical properties of SiC valve lifter are excellent in Vickers hardness 1100-1200 bending strength (300-350 Pa) fracture toughness(1.5-1.7 Mpa$.$m1/2) Through engine dynamo test-ing SiC valve lifter and metal valve lifter are examined and compared into abnormal phenomena such as early fracture unfair and early wear. It is hoped that this research will serve as an important springboard for the future study of heavy duty diesel engine parts developed by ceramics which has a good wear resis-tance relaibility and lightability.

  • PDF

Orthodontic correction of bialveolar protrusion by interproximal reproximation and water-soluble tubes bonded with deflection-based bonding technique: A case report (인접면 삭제와 변위-기반 접착술로 부착한 수용성 튜브를 이용한 절치 돌출의 교정 치료: 증례보고)

  • Roh, Yu-Yeon;Lim, Sung-Hoon;Jeong, Seo-Rin
    • The Journal of the Korean dental association
    • /
    • v.55 no.12
    • /
    • pp.850-860
    • /
    • 2017
  • Orthodontic treatment with premolar extraction is usually performed to correct bialveolar protrusion. These methods require the use of stiff rectangular working archwire which requires lengthy alignment and leveling before insertion. In this case report, interproximal reproximation was performed instead of extraction. To establish clearance between the archwire and resin domes fixing the archwire, an archwire was inserted into a water-soluble tube before fabricating resin domes. This tube is solved away by the saliva. During fabrication of resin domes, the archwire was deflected intentionally reflecting the displacement of teeth from their ideal position. This can be called as deflection-based bonding (DBB) technique. DBB is different from conventional method of positioning the brackets on its ideal position and then inserting an archwire to align the brackets. Because the orthodontic force of the archwire comes from its deflection from passive configuration, deflecting an archwire as needed can move the teeth more predictably than just bonding brackets on its ideal position. Also, areas with good alignment before orthodontic treatment can be maintained simply by not deflecting the archwire during bonding in these areas. After initial alignment, interproximal reproximation was performed to create 4.8 mm space in the maxillary arch and 4.2 mm space in the mandibular arch. These spaces were closed using orthodontic mini-implant anchorage thus retracting the maxillary incisors 4 mm posteriorly accompanied with 0.7 mm and 0.3 mm distal movement of right and left molars. By using interproximal reproximation and water-soluble tube with DBB, mild bialveolar protrusion was successfully treated without extraction.

  • PDF