• Title/Summary/Keyword: CLBP

Search Result 64, Processing Time 0.017 seconds

Relationship between Breathing Pattern Disorder and Pain in Patients with Chronic Low Back Pain (만성요통환자의 호흡패턴이상과 통증과의 상관관계)

  • Lim, Chae-Gil
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.4
    • /
    • pp.355-363
    • /
    • 2020
  • To investigate the relationship between breathing pattern disorder and pain in patients with chronic low back pain(CLBP). One hundred four patients were measured the End-tidal CO2(EtCO2) and respiration rate(RR) using capnography. Also, The Breathing-hold time(BHT), Nijmegen Questionnaire(NQ), and Thoracic excursion examinated. There was a significant correlation between EtCO2 and BHT, thoracic excursion(r=.302, r=.281)(p<.01), and a low negative correlation with RR, VAS(r=-.253, -200)(p<.05). There was a significant correlation between NQ and RR(r=.237)(p<.05). There was a low correlation between thoracic excursion and VAS(r=-.370)(p<.01). There was a significant difference in the EtCO2, RR, BHT, thoracic excursion, and VAS between the thoracic and diaphragm breathing pattern(p<.05). There were no significant differences in the NQ(p>.05). There was a correlation between EtCO2 and BHT, thoracic excursion, RR, VAS in patients with CLBP. In addition, There was a correlation between RR and NQ, thoracic excursion, and VAS. As a result, it was found that there is a close relationship between breathing pattern disorder and pain. There was a significant difference in the EtCO2 level, RR, BHT, thoracic excursion and VAS value in the comparison of thoracic breathing pattern and diaphragm breathing pattern. This is a meaningful result of suggesting a breathing pattern treatment approach in the rehabilitation and pain management of chronic low back pain patients in clinical practice.

Infrared Target Recognition using Heterogeneous Features with Multi-kernel Transfer Learning

  • Wang, Xin;Zhang, Xin;Ning, Chen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.9
    • /
    • pp.3762-3781
    • /
    • 2020
  • Infrared pedestrian target recognition is a vital problem of significant interest in computer vision. In this work, a novel infrared pedestrian target recognition method that uses heterogeneous features with multi-kernel transfer learning is proposed. Firstly, to exploit the characteristics of infrared pedestrian targets fully, a novel multi-scale monogenic filtering-based completed local binary pattern descriptor, referred to as MSMF-CLBP, is designed to extract the texture information, and then an improved histogram of oriented gradient-fisher vector descriptor, referred to as HOG-FV, is proposed to extract the shape information. Second, to enrich the semantic content of feature expression, these two heterogeneous features are integrated to get more complete representation for infrared pedestrian targets. Third, to overcome the defects, such as poor generalization, scarcity of tagged infrared samples, distributional and semantic deviations between the training and testing samples, of the state-of-the-art classifiers, an effective multi-kernel transfer learning classifier called MK-TrAdaBoost is designed. Experimental results show that the proposed method outperforms many state-of-the-art recognition approaches for infrared pedestrian targets.

Content-based image retrieval using a fusion of global and local features

  • Hee Hyung Bu;Nam Chul Kim;Sung Ho Kim
    • ETRI Journal
    • /
    • v.45 no.3
    • /
    • pp.505-517
    • /
    • 2023
  • Color, texture, and shape act as important information for images in human recognition. For content-based image retrieval, many studies have combined color, texture, and shape features to improve the retrieval performance. However, there have not been many powerful methods for combining all color, texture, and shape features. This study proposes a content-based image retrieval method that uses the combined local and global features of color, texture, and shape. The color features are extracted from the color autocorrelogram; the texture features are extracted from the magnitude of a complete local binary pattern and the Gabor local correlation revealing local image characteristics; and the shape features are extracted from singular value decomposition that reflects global image characteristics. In this work, an experiment is performed to compare the proposed method with those that use our partial features and some existing techniques. The results show an average precision that is 19.60% higher than those of existing methods and 9.09% higher than those of recent ones. In conclusion, our proposed method is superior over other methods in terms of retrieval performance.

The Effect of Kinesio Taping on the Change of Muscle Strength and Endurance in Trunk Flexion and Extension in Chronic Low Back Pain(CLBP) (만성요통 환자의 테이핑 적용 시체간의 굴곡과 선전의 근력과 지구력의 변화 측정)

  • Kim, Su-Hyung
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.11 no.2
    • /
    • pp.40-48
    • /
    • 2005
  • In this study, the muscle strength and endurance of the lumbar at flexion and extension were determined using an isokinetic muscle strength meter (Biodex) in patients with chronic lumbar go (10 male and 10 females), and the changes in muscle strength and endurance of the lumbar at flexion and extension after application of Y-shaped sacrospinalis muscle taping, typically used for patient with lumbar go, were studied. In addition, the sacrospinalis muscle taping of a different shape (I-shaped taping) was applied bilaterally centering on the spine, and the muscle strength and endurance of the lumbar at flexion and extension were determined and compared with those before taping. In addition, the results after application of Y-shaped taping and I-shaped taping were also compared. 1. The extensor muscle strength of the lumbar at loading of $60^{\circ}$/sec before application of kinesio Taping and after application of Y-shaped taping showed the level of significance (p<.05). The flexor muscle strength of the lumbar at loading of $60^{\circ}$/sec before application of kinesio taping and after application of Y-shaped taping did not show the level of significance. 2. The flexor muscle endurance of the lumbar at loading of $90^{\circ}$/sec before application of kinesio Taping and application of Y-shaped taping did not show the level of significance. The extensor muscle endurance of the lumbar at loading of $90^{\circ}$/sec before application of kinesio Taping and after application of Y-shaped taping did not show the level of significance. 3. The extensor muscle strength of the lumbar at loading of $60^{\circ}$/sec before application of kinesio Taping and after application of I-shaped taping showed the level of significance (p<.05). The flexor muscle strength of the lumbar at loading of $60^{\circ}$/sec before application of kinesio Taping and after application of I-shaped taping showed the level of significance (p<.05). 4. The flexor muscle endurance of the lumbar at loading of $90^{\circ}$/sec before application of kinesio taping and after application of I-shaped taping showed the level of significance. The extensor muscle strength of the lumbar at loading of $90^{\circ}$/sec before application of kinesio Taping and after application of I-shaped taping showed the level of significance (p<.05). 5. In comparison between after application of Y-shaped taping and after application of I-shaped taping, the flexor muscle strength of the lumbar at loading of $60^{\circ}$/sec did not show the level of significance. In comparison between after application of Y-shaped taping and after application of I-shaped taping, the extensor muscle strength of the lumbar at loading of $60^{\circ}$/ sec showed the level of significance (p<.05). 6. In comparison between after application of Y-shaped taping and after application of I-shaped taping, the flexor muscle strength of the lumbar at loading of $90^{\circ}$/sec did not show the level of significance. In comparison between after application of Y-shaped taping and after application of I-shaped taping, the extensor muscle strength of the lumbar at loading of $90^{\circ}$/sec did not showed the level of significance (p<.05).

  • PDF