• 제목/요약/키워드: CHF

검색결과 312건 처리시간 0.029초

Critical Heat Flux in Uniformly Heated Vertical Annulus Under a Wide Range of Pressures 0.57 to 15.0 MPa

  • Chun, Se-Young;Chung, Heung-June;Hong, Sung-Deok;Yang, Sun-Kyu;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.128-141
    • /
    • 2000
  • The critical heat flux (CHF)experiments have been carried out in a wide range of pressures for an internally heated vertical annulus. The experimental conditions covered ranges of pressures from 0.57 to 15.01 MPa, mass fluxes of 0 kg/$m^2$s and from 200 to 650 kg/$m^2$s, and inlet subcoolings from 85 to 413 kJ/kg. The characteristics of the present data and the effect of pressure on CHF are discussed. Most of the CHFs were identified to dryout of the liquid film in the annular or annular-mist flow. For the mass flux of 200 kg/$m^2$s, there were the indications that the CHF occurred at the transition from annular to annular-mist How in the pressure range of 3~10 MPa. For the mass fluxes of 550 and 650 kg/$m^2$s, the CHFs had a maximum value at a pressure of 2~3 MPa, and the pressure at the maximum CHF values had a trend moving toward the pressure at the peak value of pool boiling CHF as the mass flux decreased. The CHF data under a zero mass flux condition indicate that both the effects of pressure and inlet subcooling on the CHF were smaller, compared with those on the CHF with net water upward flow.

  • PDF

Program development and preliminary CHF characteristics analysis for natural circulation loop under moving condition

  • Gui, Minyang;Tian, Wenxi;Wu, Di;Chen, Ronghua;Su, G.H.;Qiu, Suizheng
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.446-454
    • /
    • 2021
  • Critical heat flux (CHF) has traditionally been evaluated using look-up tables or empirical correlations for nuclear power plants. However, under complex moving condition, it is necessary to reconsider the CHF characteristics since the conventional CHF prediction methods would no longer be applicable. In this paper, the additional forces caused by motions have been added to the annular film dryout (AFD) mechanistic model to investigate the effect of moving condition on CHF. Moreover, a theoretical model of the natural circulation loop with additional forces is established to reflect the natural circulation characteristics of the loop system. By coupling the system loop with the AFD mechanistic model, a CHF prediction program called NACOM for natural circulation loop under moving condition is developed. The effects of three operating conditions, namely stationary, inclination and rolling, on the CHF of the loop are then analyzed. It can be clearly seen that the moving condition has an adverse effect on the CHF in the natural circulation system. For the calculation parameters in this paper, the CHF can be reduced by 25% compared with the static value, which indicates that it is important to consider the effects of moving condition to retain adequate safety margin in subsequent thermal-hydraulic designs.

잡음영상의 크기와 회전불변 패턴인식을 위한 광 웨이블릿 필터 (Optical wavelet filter for Rotation and Scale-Invariant Pattern Recognition of images with Noise)

  • 이승희
    • 한국산업정보학회논문지
    • /
    • 제9권2호
    • /
    • pp.81-88
    • /
    • 2004
  • 잡음을 갖는 영상의 크기와 회전불변 패턴인식을 위한 광 웨이블릿 CHF-fSDF((wavelet circular harmonic function-filter modulation synthetic discriminant function, WCHF-fSDF) 필터를 제안하였다. 웨이블릿 CHF-fSDF 필터는 기준영상에 대하여 크기변화된 영상들을 웨이블릿 변환한 후, 이들로부터 추출한 단일 원형고조함수를 학습영상으로 사용하여 합성한다. 제안된 광 웨이블릿 CHF-fSDF 필터는 정합필터의 형태로서 전통적인 4f 광 상관기에 적용할 수 있도록 하였다. 컴퓨터 모의실험을 통하여 제안된 필터는 크기변화와 회전에 무관한 상관출력을 나타내며 특히 잡음환경하에서 유용함을 확인하였다.

  • PDF

AN EXPERIMENTAL STUDY ON POST-CHF HEAT TRANSFER FOR LOW FLOW OF WATER IN A $3\times3$ ROD BUNDLE

  • MOON SANG-KI;CHUN SE-YOUNG;CHO SEOK;KIM SE-YUN;BAEK WON-PIL
    • Nuclear Engineering and Technology
    • /
    • 제37권5호
    • /
    • pp.457-468
    • /
    • 2005
  • An experimental study on post-CHF heat transfer has been performed with a $3\times3$ rod bundle using a vertical steam-water two-phase flow at low flow conditions. The effects of various parameters on the post-CHF heat transfer are investigated and the reasons for the parametric effects are discussed. As the heat transfer regime changes from CHF to post-CHF, the radial wall temperature distribution is changed depending on the pressure and the mass flux conditions. The superheat of the fluid increases considerably with an increase of the wall temperature (or heat flux) and with a decrease of the mass flux. This implies, indirectly, a strong thermal non-equilibrium at high wall temperature and low mass flux conditions. In order to improve the prediction accuracy of the existing post-CHF correlations, it is necessary to perform more experiments, particularly direct measurement of the vapor superheat, and to modify the correlation by considering a strong thermal non-equilibrium at low flow and low pressure conditions.

Quality of Low Fat Chicken Nuggets: Effect of Sodium Chloride Replacement and Added Chickpea (Cicer arietinum L.) Hull Flour

  • Verma, Arun K.;Banerjee, Rituparna;Sharma, B.D.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제25권2호
    • /
    • pp.291-298
    • /
    • 2012
  • While attempting to develop low salt, low fat and high fibre chicken nuggets, the effect of partial (40%) common salt substitution and incorporation of chickpea hull flour (CHF) at three different levels viz., 5, 7.5 and 10% (Treatments) in pre-standardized low fat chicken nuggets (Control) were observed. Common salt replacement with salt substitute blend led to a significant decrease in pH, emulsion stability, moisture, ash, hardness, cohesiveness, gumminess and chewiness values while incorporation of CHF in low salt, low fat products resulted in decreased emulsion stability, cooking yield, moisture, protein, ash, color values, however dietary fibre and textural properties were increased (p<0.01). Lipid profile revealed a decrease in total cholesterol and glycolipid contents with the incorporation of CHF (p<0.01). All the sensory attributes except appearance and flavor, remained unaffected with salt replacement, while addition of CHF resulted in lower sensory scores (p<0.01). Among low salt, low fat chicken nuggets with CHF, incorporation CHF at 5% level was found optimum having sensory ratings close to very good. Thus most acceptable low salt, low fat and high fibre chicken nuggets could be developed by a salt replacement blend and addition of 5% CHF.

노인환자에서 Digoxin의 약동학적 매개변수 변화 (A Variation of Pharamcokinetic Parameters of Digoxin in Elderly Patients)

  • 배성미;양성희;황보신이;박창선;홍경자;장춘곤;이석용
    • 약학회지
    • /
    • 제46권1호
    • /
    • pp.30-38
    • /
    • 2002
  • The elderly patients are the most frequent users of digoxin because of increased prevalence of the two primary indications for digoxin therapy, fibrillation (AE) and congestive heart failure (CHF). This study performed to observe a variation in digoxin pharamcokinetic parameters in advancing age and changing kidney function and to compare the measured clearance with the calculated clearance. The 123 drug monitoring records of inpatients who had achieved steady state concentration of digoxin at a tertiary hospital from April 1999 to October 2001 were reviewed. In advancing age, measured digoxin clearance, volume of distribution and creatinine clearance were reduced. Compared with the calculated digoxin clearance, the measured digoxin clearance was more reduced in patients without CHF Especially, in elderly patients without CHF the measured digoxin clearance was lower than the calculated digoxin clearance. In contrast to nonCHF patients the measured value was greater than the calculated value in all CHF patients. Findings from this study indicate that the calculated digoxin clearance in elderly patients without CHF substantially overestimated the true clearance. Thus, it appears that the use of calculated digoxin clearance to estimate serum digoxin concentration may result in underestimation of the true serum concentration in a number of elderly patients without CHF.

Critical heat flux (CHF) in pool boiling under static and rolling conditions

  • Tanjung, Elvira F.;Albdour, Samah A.;Jeong, Yeon Uk;Jo, Daeseong
    • Nuclear Engineering and Technology
    • /
    • 제52권3호
    • /
    • pp.520-529
    • /
    • 2020
  • Experimental investigations were attempted to simultaneously observe the vapor behaviors and critical heat flux under static and rolling conditions. From visualization results, vapor initiated, grew, and detached individually in a vertical direction from the static heated surfaces (at 10, 20, and 30°). While under rolling motion, initiated vapor grew, and interacted with each other, resulting in forming a wider dry spot on the heated surface. Also, it was observed that the vapor drifted upward and stayed on the heated surface longer compared to under static condition. The faster the platform rolls, the longer the vapor stay on the heated surface, significantly decreasing the CHF. On the other hand, as the platform rolls slower (at high rolling period), CHF increases. CHF was decreased with increasing maximum rolling amplitude and inclination angle under both conditions (static and rolling). CHF under rolling conditions was noticed to be lower than under static condition except at maximum rolling amplitude of 10°. The bubble departure frequency at a maximum rolling amplitude of 10° was the highest among all of rolling amplitudes, thereby enhancing the CHF. These results indicate that rolling motion significantly affects vapor behaviors and CHF.

The Button effect of CANFLEX Bundle on the Critical Heat Flux and Critical Channel Power

  • Park, Joohwan;Jisu Jun;Hochun Suk;G.R. Dimmick;D.E. Bullock;W. Inch
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.528-533
    • /
    • 1997
  • A CANFLEX(CANdu FLEXible fuelling) 43-element bundle has developed for a CANDU-6 reactor as an alternative of 37-element fuel bundle. The design has two diameter elements (11.5 and 13.5㎜) to reduce maximum element power rating and buttons to enhance the critical heat flux(CHF), compared with the standard 37-element bundle. The freon CHF experiments have performed for two series of CANFLEX bundles with and without buttons with a modelling fluid as refrigerant H-l34a and axial uniform heat flux condition. Evaluating the effects of buttons of CANFLEX bundle on CHF and Critical Channel Power(CCP) with the experimental results, it is shown that the buttons enhance CCP as well as CHF. All the CHF's for both the CANFLEX bundles are occurred at the end of fuel channel with the high dryout quality conditions. The CHF enhancement ratio are increased with increase of dryout quality for all flow conditions and also with increase of mass flux only lot high pressure conditions. It indicates that the button is a useful design lot CANDU operating condition because most CHF flow conditions for CANDU fuel bundle are ranged to high dryout quality conditions.

  • PDF

An Experimental Study of Critical Heat Flux in Non-uniformly Heated Vertical Annulus under Low Flow Conditions

  • Chun, Se-Young;Moon, Sang-Ki;Baek, Won-Pil;Chung, Moon-Ki;Masanori Aritomi
    • Journal of Mechanical Science and Technology
    • /
    • 제17권8호
    • /
    • pp.1171-1184
    • /
    • 2003
  • An experimental study on critical heat flux (CHF) has been performed in an internally heated vertical annulus with non-uniform heating. The CHF data for the chopped cosine heat flux have been compared with those for uniform heat flux obtained from the previous study of the authors, in order to investigate the effect of axial heat flux distribution on CHF. The local CHF with the parameters such as mass flux and critical quality shows an irregular behavior. However, the total critical power with mass flux and the average CHF with critical quality are represented by a unique curve without the irregularity. The effect of the heat flux distribution on CHF is large at low pressure conditions but becomes rapidly smaller as the pressure increases. The relationship between the critical quality and the boiling length is represented by a single curve, independent of the axial heat flux distribution. For non-uniform axial heat flux distribution, the prediction results from Doerffer et al.'s and Bowling's CHF correlations have considerably large errors, compared to the prediction for uniform heat flux distribution.

KMRR 핵연료에 대한 고유량 임계열속 상관식 개발 (Development of a High Flow CHF Correlation for the KMRR Fuel)

  • Park, Cheol;Hwang, Dae-Hyun;Yoo, Yeon-Jong;Park, Jong-Ryul
    • Nuclear Engineering and Technology
    • /
    • 제26권2호
    • /
    • pp.237-246
    • /
    • 1994
  • KMRR 노심의 열수력 설계 및 안전 해석을 위한 고유량 CHF 상관식을 개발하였다. 상관식 개발에는 fin이 부착된 경우와 부착되지 않은 경우의 가열봉에 대한 단일봉 CHF 실험 자료를 사용하였다. 상관식은 Reynolds 수, 열역학 평형 건도, 액상과 기상의 밀도비 및 등가수력 직경비 등의 무차원 변수로 이루어져 있으며, fin이 있는 경우와 없는 경우의 가열 둘레비를 사용하여 fin의 영향을 고려하였다. 이처럼 단일봉에 대하여 개발된 상관식의 KMRR 핵연료 집합체에 대한 적용 타당성을 보이기 위하여 비가열면 및 축방향 비균일 출력 분포의 영향을 논의하였다. CHF 실험 자료 분석 결과, 상관식 한계 DNBR은 1.44로 결정되었다.

  • PDF