• Title/Summary/Keyword: CHANGE OF THE DENSITY

Search Result 2,991, Processing Time 0.038 seconds

A Study on the Relationship of Change of Mechanical Properties and Carbonyl Index Induced through Short-wavelength Ultraviolet Radiation (254 nm) for High Density Polyethylene (단파장 자외선(254 nm)에 노출된 고밀도 폴리에틸렌 수지의 카르보닐 지수(CI)와 기계적 물성 변화의 관계에 관한 연구)

  • Kim, Chang-Hwan;Shin, Jin-Yong
    • Applied Chemistry for Engineering
    • /
    • v.24 no.2
    • /
    • pp.138-143
    • /
    • 2013
  • This paper studied the possibility to predict a mechanical property variation from changes in created carbonyl bands by irradiating the surface of high-density polyethylene with short-wavelength ultraviolet radiation of 254 nm to induce a fast chemical degradation. The meaning of this study lies in checking whether a mechanical property change with the same chemical property as the induced optical deterioration is caused by using a UVC lamp with high photon energy instead of optical deterioration via xenon arc light source and outdoor exposure test via natural sunlight requiring a long time. The mechanical strength of high-density polyethylene checked by a tensile test and a creep destruction test showed a similar tendency with CI changes. In particular, the yield strength and elongation had a close relationship with the exposure time to ultraviolet radiation. Accordingly, this paper presented a method to grasp the mechanical property change outdoors requiring a long time more fast through the relationship between the mechanical property change and the carbonyl index using a UVC lamp causing the fast surface degradation.

Characterization of Water Vapor Transmission & Dielectric Breakdown in Insulation Materials for Jacket Compound (자켓 컴팍운드용 절연재의 수증기투과 및 절연파괴 특성)

  • 송재주;한재홍;송일근;한용희;한병성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.52-56
    • /
    • 2001
  • Experiments of 2 type on insulating compounds accomplished to change PVC using in URD(Underground) power cable jacketing. one was DB(Dielectric Breakdown) test on the pure base resins and the others were WVT(Water Vapor Transmission) test on the compounds which contained C/B(Carbon Black), anti-oxidant to base resin. a kind of specimens made by pressing to resin of pellet or lump form was HDPE(High Density Polyethylene), MDPE(Medium Density Polyehylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC(Polyvinyl Chloride). As a results of AC DB and WVT test, we saw that strength of Insulation was HDPE> LLDPE = MDP E> LDPE and WVT ratio was HDPE

  • PDF

Study on the Pervaporation Characteristic of Water-alcohol Mixtures through Aromatic Polyetherimide Membranes : II. the Pervaporation of Water-isopropanol Mixtures by the Density Change of Skin Layer (방향계 폴리에테르이미드막의 물-알콜 혼합액의 투과증발 특성에 관한 연구 : II.skin layer의 density변화에 의한 물-이소프로판올 혼합액의 투과증발)

  • Kim, S.G.;Jegal, J.G.;Lee, K.H.
    • Applied Chemistry for Engineering
    • /
    • v.8 no.5
    • /
    • pp.853-859
    • /
    • 1997
  • For asymmetric polyetherimide membranes having a dense layer gradient structure on the skin layer, the morphology change and pervaporation behaviors of water/isopropanol mixture through chemical modification of dense skin layer were investigated. The extent of the density was controlled by the evaporation, time, and when the evaporation time was increased from 0 min to 4 min, the permeation flux was decreased, the separation factor was increased. Also, the pervaporation behaviors of the polyetherimide membranes modified with sodium hydroxide solution, as the modification time of dense skin layer increased, the selectivity increased, and the permeation flux decreased. The morphology change identified by SEM shows that the density of dense skin layer tends to increase with increasing modification time, this result is consistent with above observations.

  • PDF

Evaluation of peri-implant bone density changes in $Br{\aa}nemark$ implants by computer assisted densitometric image analysis (CADIA) (디지털 공제술을 이용한 $Br{\aa}nemark$ 임플란트 주위 골조직 분석)

  • So, Sung-Soo;Noh, Hyuen-Soo;Kim, Chang-Sung;Choi, Seong-Ho;Chae, Jung-Kiu;Kim, Chong-Kwan;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.1
    • /
    • pp.137-150
    • /
    • 2007
  • CADIA(Computer-assisted densitometric image analysis) method is used to analyze bone density changes around the implants. The usefullness and reproducibility of the method was assessed. We tried to find out if there is any possibility to quantitiate and qualitify peri-implant bone density change as time passes. And we concluded that this newly developed linear analysis is efficient for analyzing peri-implant bone density change non-Invasively. In this study, 2152 machined $Br{\aa}nemark$ fixtures installed from 1994 to 2002 in the department of Periodontics, Dental hospital of College of Dentistry, Yonsei University were included. Of these fixtures 22 radiographically analyzable failed fixtures were used as experimental group, and 22 successful implants placed in the same patient were used as control group. 1. 57 out of 1635 machined $Br{\aa}nemark$ standard and Mk II implants system failed, the survival rate was 96.5%. And 11 out of 517 machined $Br{\aa}nemark$ Mk III and Mk IV implants system failed, the survival rate was 97.9%. Total survival rate was 96.8%. 2. 22 failed implants were used for the analysis, 10 of which failed before prosthetic treatment due to infection and overheating. 12 failed due to overload after prosthetic treatment, 63.6% of which failed during the early phase of functional loading, i, e. before 1 year of loading. 3. Bone density change values around coronal region of the failed implants were $-6.54{\pm}6.35$, middle region were $-3.53{\pm}5.78$, apical region were $-0.75{\pm}10.33$, resulting in average of $-3.71{\pm}8.03$. 4. Bone density change values around coronal region of the successful implants were $4.25{\pm}4.66$, middle region were $6.33{\pm}5.02$, apical region were $9.89{\pm}4.67$, resulting in average of $6.27{\pm}5.29$. 5. There was a statistically significant difference between two groups (p<0.01). In conclusion, the linear analysis method using computer-assisted densitometric image analysis could be a useful method for the analysis of implants, and could be used for future implant researchs.

Characteristics of Soil Parameter for Lade's Single Work-Hardening Constitutive Model with Relative Density of Bottom ash (석탄회의 상대밀도에 따른 Lade 단일항복면 구성모델의 토질매개변수 특성)

  • Kim, Chan-Kee;Lee, Jong-Cheon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.4
    • /
    • pp.87-98
    • /
    • 2013
  • This study was performed a series of the isotropic compression-expansion tests and the drained triaxial tests with various the relative densities 40%, 60%, 80% and 95% for bottom ash. Using the tests results the characteristic of the parameters of Lade's single hardening constitutive model were investigated. The soil parameters Kur and n representing elastic behavior are not much affected by the change of the relative density. The other parameters such as failure criterion(m, ${\eta}_1$), hardening function(c, p) and plastic potential(${\psi}_2$, ${\mu}$) are in a positive linear relationship with the relative density. Since the soil parameters h and ${\alpha}$ representing yield function do not change much to the change of relative density and also closely related to failure criterion, they can be replaced by failure criterion ${\eta}_1$. We also observed that predicted values from the Lade's single hardening constitutive model were well consistent with the observed data.

Measurement of Soil Moisture Content Using RF Impedance in the Range of 1 to 30MHz (고주파 임피던스를 이용한 토양수분함량 측정에 관한 연구)

  • Kim, Ki-Bok;Lee, Nam-Ho;Noh, Sang-Ha
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.6
    • /
    • pp.79-88
    • /
    • 1998
  • This study was conducted to measure the moisture content of soil using RF impedance in the range of 1 to 30MHz. Considering the water potential flow in the soils, two types of sensor such as parallel cylinder and perpendicular plate type were fabricated and tested. The capacitance and resistance of sonsors for soil samples having moisture content range of 2 to 27% were measured by Q-meter (HP4342). The higher soil moisture content was and the larger soil bulk density was, the more the capacitance of sensors increased. To eliminate the effect of bulk density on measuring soil moisture content using RF impedance, two kinds of model having the density independent functions such as the ratio of capacitance change to conductance change and weight of water and dry soils respectively were developed and estimated by regression analysis.

  • PDF

Estimation of Flaw Depth and Height by Radiography (방사선투과사진에 의한 결함깊이 및 높이의 평가)

  • Kang, Kae-Myung;Park, Un-Su;Sim, Eon-Deok
    • Korean Journal of Materials Research
    • /
    • v.12 no.8
    • /
    • pp.682-687
    • /
    • 2002
  • The three-dimensional estimation on the depth and height of flaw by using the difference of radiographic contrast density was studied. First, the specimens having artificial flaws of various depths and heights were prepared and the radiographic testing was performed. The radiographic depth of flaw was investigated and estimated on the effect of the scattered radiation with the change of distance between flaw and film. The height of flaw was estimated from the radiographic test with the reference specimen. The radiographic contrast with flaw depth decreased with increasing the flaw depth. The scattered radiation increased with increasing flaw depth and varied with the location between flaw and film. However, in the case of flaw height, the contrast density increased with increasing flaw height. It is thought due to the change in volume generating the scattered radiation which reaches a film.

Characteristics of Soil Parameter for Lade's Single Work-Hardening Constitutive Model with Relative Density of Baekma River Sands (백마강 모래의 상대밀도에 따른 Lade의 단일항복면 구성모델의 토질매개변수 특성)

  • Cho, Won-Beom;Kim, Chan-Kee;Kim, Joong-Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1C
    • /
    • pp.11-17
    • /
    • 2011
  • This study was performed a series of the isotropic compression-expansion tests and the drained triaxial tests with various the relative densities 25%, 50%, 80% and 100% for Baekma river sand. Using the tests results the characteristic of the parameters of Lade's single hardening constitutive model were investigated. The soil parameters Kur and n representing elastic behavior are not much affected by the change of the relative density. The other parameters such as failure criterion (m, ${\eta}_1$), hardening function (C, p) and plastic potential (${\Psi}_2$, ${\mu}$) are in a positive linear relationship with the relative density. Since the soil parameters h and $\alpha$ representing yield function do not change much to the change of relative density and also closely related to failure criterion, they can be replaced by failure criterion ${\eta}_1$. We also observed that predicted values from the Lade's single hardening constitutive model were well consistent with the observed data.

Change of Geotechnical Properties of Sand due to Cementation (고결(Cementation)에 의한 모래의 지반공학적 특성 변화)

  • Lee, Moon-Joo;Kim, Seung-Han;Choi, Sung-Kun;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.153-160
    • /
    • 2006
  • In this study, the change of getechnical properties of sand due to cementation was investigated by undrained triaxial test of isotropicallv consolidated sample. For inducing the cementation, $5\sim20%$(sand weight) gypsum were included in the sand and cured in the mold under the overburden pressure 55kPa. The yielding strength and stiffness of cemented sand were increased and also the aspects of effective pore water pressure were changed as the degree of cementation and the relative density. Generally the degree of cementation exerted more influence on the behavior of cemented sand than the relative density.

  • PDF

A Feasibility Study for Application of On-Line Wear Condition Monitoring Technique to the High-powered Diesel Engine (고출력 디젤 엔진의 On-Line 마모상태진단 기술 적용을 위한 기초연구)

  • 윤민호;정동윤;공호성
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.59-65
    • /
    • 1997
  • The calibration of O.M.D is carried out experimentally and is analysed theoretically. O.M.D experimentally measures the change in optical density of artificially contaminated oil which contains Fe powder of 5, 10, 20, 30, 40, 50, 70, 100, 200 ppm. The change in optical density, D$_1$ means the logarithmic transmittance of I$_0$ over $I_1 D_2$ denotes the logarithmic transmittance I$_2$ over I$_1$ on electromagnetic force which arranges the ferrous particles along the line of magnetic force. The theoretical D$_1$ which increases linearly as increasing Fe concentrations, is analysed by light attenuation theory. The difference between theoretical D$_1$ and experimental D$_1$ is due to the attenuation of micro bubbles and the agglomeration of fine particles in the sample oil. The calibrated O.M.D is applied to the sample oil from the high-powered diesel engine. Also the results are compared with those out of the off-line techniques such as JOAP and ICP.

  • PDF