• Title/Summary/Keyword: CG height

Search Result 32, Processing Time 0.026 seconds

The Effect of Lower Trapezius Resistance Exercises on Shoulder Alignment and Muscle Activity in Patient with Rounded Shoulder Posture (아래등세모근 저항운동이 둥근 어깨를 가진 성인의 어깨 정렬과 근활성도에 미치는 영향)

  • Young-Mi Kim;Ji-Won Han
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.4
    • /
    • pp.41-50
    • /
    • 2023
  • Purpose : The aim of study was to determine the effect of lower trapezius muscle strengthening exercises on the height of rounded shoulder posture and muscle activity in patients with rounded shoulder posture. Methods : Thirty-one subjects with rounded shoulders were selected and assigned, with the use of a random number table, to an experimental group (EG, n=16) that received resistance exercises of the trapezius (lower) muscles or a control group (CG, n=15) that received isometric exercises of the lower trapezius muscles. In the EG, with the subject in a prone position, both arms were abducted at the angles suggested for each posture (145 °, 45 ° abduction), with the hands holding dumbbells to assume a functional posture. The CG performed only isometric exercises without dumbbells in the same conditions. At the start signal, with the thumb raised, the arm was raised to the level of the ear. Both groups were assessed by the height of the rounded shoulder posture (RSP) and muscle activity (EMG). The intervention was performed three times a week. Results : The RSP significantly decreased during the intervention period in both the EG and CG (p<.05), and a significant difference was determined between the RSP of the two groups (p<.05). In the EG, the EMG significantly increased during the intervention period (p<.05), but the CG did not show any significant increase (p>.05). The final EMG was significantly higher in the EG than in the CG (p<.05). Conclusion : Both the EG and CG showed positive improvement in rounded shoulder posture during the intervention period. In particular, lower trapezius resistance exercise appears to reduce shoulder height and positively affects the activity of muscles around the shoulder.

A Study on Geoid Height of Provinces in South Korea by Terrain correction of Earth Gravitational Models (EGMs의 지형보정에 따른 국내 지역별 지오이드고 연구)

  • Lee, yong-chang
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.942-946
    • /
    • 2007
  • The new gravity field combination models are expected to improve the knowledge of the Earth's global gravity field. This study evaluates six global gravity field models derived from gravimetry and altimetry surface data in a comparison with ground truth in South Korea. For calculating a more accurate estimate of the geoid heights from the height anomalies, the terrain corrections due to the terrain masses over geoid have considered, the model for the topographic correction is a spherical harmonic expansion of the ETOPO2 DTM model. Geoid heights obtained from GPS and levelling in land area of South Korea are compared with those from the EGMs. The results show that EIGEN-CG03C EGM and EIGEN-GL04C EGM displayed the nearest results to GPS/leveling, and also confirmed the importance of terrain correction for geoid height in case of the uneven topography.

  • PDF

An experimental study on the stern bottom pressure distribution of a high-speed planing vessel with and without interceptors

  • Seok, Woochan;Park, Sae Yong;Rhee, Shin Hyung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.691-698
    • /
    • 2020
  • In this study, the effects of hydrodynamic interceptors on a high-speed vessel were investigated to identify the operating principle based on experiments. Model tests were performed using a high-speed towing carriage. The resistance, trim and rise of Center of Gravity (CG) of the high-speed vessel were measured for various ship speeds and interceptor heights. As the interceptor height increased, the trim and rise of CG were reduced. In order to quantitatively analyze these phenomena, the pressure at the stern bottom was measured using tactile sensors. The reliability of the measured results from the tactile sensors was verified through repeat tests. The pressure on the stern bottom increased in proportion to the interceptor height, as the interceptor partially blocked the flow there. Then, the trim was reduced. However, as the ship speed increases, the pressure at the location close to the interceptor decreases when the interceptor height is small, leading to increased trim. Therefore, the interceptor height for running attitude control should be carefully determined considering multiple factors in the operating condition of the high-speed planing hull.

Effects of Kangaroo Care on Growth in Premature Infants and on Maternal Attachment (캥거루식 돌보기가 미숙아의 성장과 모아애착에 미치는 효과)

  • Jang, Me-Young
    • Child Health Nursing Research
    • /
    • v.15 no.4
    • /
    • pp.335-342
    • /
    • 2009
  • Purpose: This study, using a pre-post test design of non-equivalence comparative group, was done to determine effects of Kangaroo care (KC) on growth in premature infants and on maternal attachment (MA). Methods: Fifty-three premature infants were assigned to the KC (24) or control group (CG) (29). Data were collected from July 2007 to June 2008. KC was given for 60 min at a time, Monday, Wednesday, and Friday for 10 times. Weight, height, and head circumference (HC) of premature infants were checked before the program started. Following the initial measurement, the program was given and measurements were taken again at the end of the program. For measurement of attachment between mother and infant, data collection was done using structured self-reported questionnaires. Results: KC group had a higher weight (t=2.565, p=.013), height (t=2.182, p=.034) and HC (t=2.468, p=.017) than the CG. Compared to the CG, the KC had significantly higher scores in MA (t=2.026, p=.048). Conclusion: The results of this study suggest that the practice of KC in the nursing environment might actively promote attachment between mother and infant as well as acceleration of growth for premature infants as one of the most efficient nursing intervention.

Calculation of orthometric correction by observed gravity at Korean benchmark line (우리나라 수준노선에서 실측중력에 의한 정사보정량 계산)

  • Kim, Cheol-Young;Lee, Suk-Bae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.3
    • /
    • pp.319-325
    • /
    • 2011
  • It has been used not orthometric height but normal orthometric height for the official height in Korean benchmark because it has been used not observed gravity but normal gravity for the computation of orthometric correction. The purpose of this study is to propose height renewal method of Korean benchmark. For this purpose, we observed gravity by CG5 digital gravimeter in both the first benchmark line between Sokcho and Gangneung area and the second benchmark line between Soksa and Inje area. We calculated relative gravity value and orthometric correction in all benchmarks. So, the maximum orthometric correction shows -0.349mm in the first benchmark line, and the maximum orthometric correction shows -44.060mm in the second benchmark line. In conclusion, we can confirm that the orthometric correction based on observed gravity is necessary for more accurate official height computation in the Korean benchmark.

RADIOGRAPHIC COMPARATIVE STUDY OF FACIAL SKELETAL ASYMMETRY IN CRANIOMANDIBULAR DISORDER PATIENTS (두개하악장에 환자의 안면골 비대칭성에 관한 방사선사진상 비교분석)

  • Park Won-Kyl;Choi Eui-Hwan;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.291-304
    • /
    • 1994
  • The purpose of this study was to analyze the facial asymmetry of the patients with the craniomandibular disorder. In this study, 50 patients, who have joint clicking and pain, mouth opening limitation, and 40 dental students, Chosun University, who did not posses any restoration and orthodontic treatment, joint clicking and pain, mouth opening limitation, were selected as the control group. Both the control group and the patient group were takened skull P-A, submento-vertex radiogram by standized methods. After that, the deviation and facial asymmetry were measured and analyzed. The results of the this study were as follows: 1. In the Skull P-A radiogram, the width difference of control group and patient group measured that the △ Cg-Go-Cl: control group were 3.35㎜, patient group were 4.51㎜ (P<0.05), the △Cg-Zy-Go: control group were 1.83㎜, patient group were 3.27㎜(P<0.001). 2. In the Skull P-A radiogram, the height difference of control group and patient group measured that the △ Cg-Go-Cl: control group were 131.85㎜, patient group were 188.45㎜(P<0.05), the △Cg-Zy-Go: control group were 1.58㎜, patient group were 2.68㎜(P<0.00l). 3. In the Skull P-A radiogram, the area difference of control group and patient group measured that the △ Cg-Go-Cl: control group were 120.76㎟, patient group were 185.49㎟(P<0.05), the △Cg-Zy-Go: control group were 2.29㎟, patient group were 3.37㎟(p<0.05). 4. In the submento-vertex radiogram, the width difference of control group and patient group measured that the △Mr-Cl-Ia: control group were 1.50㎜, patient group were 2.35㎜(P<0.05), the △Mr-Cm-Ia: control group were 1.75㎜, patient group were 3.17㎜(P<0.05), the △Mr-Go-Ia: control group were 1.96㎜, patient group were 3.24㎜(P<0.001), the △Mr-Cp-Co: control group were 1.74㎜, patient group were 2.73㎜(P<0.05). 5. In the submento-vertex radiogram, the height difference of control group and patient group measured that the △Mr-Cp-Ia: control group were 1.68㎜, patient group were 2.46㎜P<0.05), the △Mr-CI-Ia: control group were 2.38㎜, patient group were 3.74㎜(P<0.05), the △Mr-Co-Ia: control group were 1.63㎜, patient group were 2.80㎜(P<0.05), the △Mr-Cm-Ia: control group were 1.45㎜, patient group were 3.12㎜(P<0.001). 6. In the submento-vertex radiogram, the area difference of control group and patient group measured that the △ Mr-Cp-Ia: control group were 73.17㎟, patient group were 110.16㎟(P<0.05), the △Mr-Cl-Ia: control group were 105.09㎟, patient group were 180.87㎟(P<0.001), the △Mr-Co-Ia: control group were 103.31㎟, patient group were 148.48㎟(P<0.05), the △Mr-Cm-Ia: control group were 97.01㎟, patient group were 167.83㎟(P<0.05), the △Mr-Go-Ia: control group were 104.24㎟, patient group were 205.90㎟(P<0.05).

  • PDF

Utilizing Precise Geoid Model for Conversion of Airborne LiDAR Data into Orthometric Height (항공라이다데이터 정표고 변환을 위한 정밀지오이드 모델 이용)

  • Lee, Won-Choon;We, Gwang-Jae;Jung, Tae-Jun;Kwon, Oh-Seob
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.4
    • /
    • pp.351-357
    • /
    • 2011
  • In this study, we have intended to analyze the possibility of using the precise geoid model and to find the best geoid model for working by the airborne LiDAR system. So we have calculated the geoid height from the precise geoid models (KGEOID08, EGM2008, EIGEN-CG03C) and have analyzed results by comparing the geometric geoid height from surveying and geoid heights from geoid models. As a result, the KGEOID08 that had 0.152m of RMSE was assessed the best geoid model for making DEM(DTM) by airborne LiDAR system. Also we have found the needed arrangement and numbers of reference point when the KGEOID08 was used for conversion into orthometric height of LiDAR data.

Mathcad program as a useful tool for the teaching and studying the sport biomechanics (운동역학의 교육과 연구용 도구로서 Mathcad의 유용성)

  • Sung, Rak-Joon
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.301-311
    • /
    • 2004
  • The purpose of this study was to verify the usefulness of the Mathcad program as a tool for the studying and teaching the sport biomechanics. A projectile motion was analyzed because it is the one of the most popular motion in sports activities. A 3 dimensional CG data for the high jump bar clear phase was used to calculate the initial velocity vector of the CG. Linear regression function and other functions such as cubic spline and derivative of Mathcad were used to calculate this vector. Finally, the approach angle to the bar and peak jump height was calculated. Programming in Mathcad was relatively easy compare to traditional computer language such as Fortran and C, because of the unique documentation method of Mathcad. Additionally the 2 and 3 dimensional graph function was very easy and useful to describe the mechanical data. If the use of Mathcad program is more popular in the field of sport biomechanics, it could greatly contribute to overcome the limit of research caused by the lack of proper programming ability.

The Study on the Kinematics of Carbody Tilting Mechanism for Railway Vehicles (철도차량용 차체틸팅기구의 기구학적 특성연구)

  • 김정석;김남포;고태환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.384-388
    • /
    • 2004
  • This study presents parametric studies for design of tiling mechanism to be used in 180km/h tilting train. The titling mechanism is composed of 4 links, a tilting bolster and an electro-mechanical actuator. First we have determined the installation height of tilting actuator using 3D tilting bogie modeling. Secondary, we verified movements of the tiling center and train body CG along variation of upper and lower span length. From this study, we obtained the upper and lower span length to minimize the lateral and vertical motion of CG of train body. Finally, we evaluated the tilting actuator force and power required to tilt the train body to $\pm$8$^{\circ}$.

  • PDF

Characterization of the Tilting Link Mechanism for the Tilting Train (틸팅차량용 틸팅 링크메커니즘의 특성연구)

  • Kim Nam-Po;Kim Jung-Seok
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.1
    • /
    • pp.34-40
    • /
    • 2005
  • This study presents parametric studies for design of a tilting mechanism to be used in 180km/h tilting train. The tilling mechanism is composed of 4 links, a lilting bolster old an electro-mechanical actuator. The movements of the tiling center, CG of the train body, coupler center and tilting actuator along variation of upper and lower span length have been verified by the kinematic analysis. Moreover, the inclination angle and the stroke of the tilting actuator according to the variation of the tilting angle from +8 degrees to -8 degrees have been investigated. From this study, the relation between the movements of the CG of the train body, coupler center and tilting actuator and the height of the tilting center could be evaluated.