• 제목/요약/키워드: CFX-11

검색결과 73건 처리시간 0.026초

집속효율 향상을 위한 외장유동노즐 가속 구간의 최적설계 연구 (Optimal Design of Sheath Flow Nozzle Acceleration Section for Improving the Focusing Efficiency)

  • 이진우;진정민;김윤제
    • 한국군사과학기술학회지
    • /
    • 제22권6호
    • /
    • pp.763-772
    • /
    • 2019
  • There is a need to use sheath flow nozzle to detect bioaerosol such as virus and bacteria due to their characteristics. In order to enhance the detection performance depending on nozzle parameters, numerical analysis was carried out using a commercial code, ANSYS CFX. Eulerian-lagrangian approach method is used in this simulation. Multiphase flow characteristics between primary fluid and solid were considered. The detection performance was evaluated based on the results of flow field in nozzle chamber such as focusing efficiency and swirl strength. In addition, Latin hypercube sampling(LHS) of design of experiment(DOE) was used for generating a near-random sampling. Then, the acceleration section is optimized using response surface method(RSM). Results show that the optimized model achieved a 6.13 % in a focusing efficiency and 11.47 % increase in swirl strength over the reference model.

이중관 열교환기의 유체 유입위치와 회전길이에 따른 유동특성 (Flow Characteristic with Distance of Inlet Port and Rotating Length of Fluid in the Double Heat Exchanger)

  • 이승하;차동안;권오경
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.51-57
    • /
    • 2013
  • The length and position of the inlet port on the double tube heat exchanger is analyzed by CFX ver.11 for studying the characteristic of its flow distribution. When the boundary conditions of the inlet temperature and mass flow rate were each $20^{\circ}C$ and 10 ~ 50 kg/min, 3 models that are based on the distance between the inlet port and the center of the heat exchanger(0, 5.025, 10.05 mm) were analyzed to find the uniformity of the flow rate. Based on the flow rate, 4 lengths (23.723, 33.890, 44.057, 57.274 mm) were used to study the flow distribution according to Reynolds Number. The results show that, when the distance from the inlet to the position of the center of the heat exchanger is 10.05 mm and the length is 57.274 mm, the flow distribution is the most unified.

Numerical Predictions of Heat Transfer in the Fluidized Bed Heat Exchanger

  • Ahn, Soo-Whan
    • 농업생명과학연구
    • /
    • 제44권4호
    • /
    • pp.29-43
    • /
    • 2010
  • The numerical analysis by using CFX 11.0 commercial code was done for proper design of the heat exchanger. The present experimental studies were also conducted to investigate the effects of circulating solid particles on the characteristics of fluid flow, heat transfer and cleaning effect in the fluidized bed vertical shell and tube type heat exchanger with counterflow, at which a variety of solid particles such as glass ($3mm{\Phi}$), aluminum ($2{\sim}3mm{\Phi}$), steel ($2{\sim}2.5mm{\Phi}$), copper ($2.5mm{\Phi}$) and sand ($2{\sim}4mm{\Phi}$) were used in the fluidized bed with a smooth tube. Seven different solid particles have the same volume, and the effects of various parameters such as water flow rates, particle diameter, materials and geometry were investigated. The present experimental and numerical results showed that the flow velocity range for collision of particles to the tube wall was higher with heavier density solid particles, and the increase in heat transfer was in the order of sand, copper, steel, aluminum, and glass. This behavior might be attributed to the parameters such as surface roughness or particle heat capacity.

미세채널 워터블록의 유입부 형상에 따른 유량분배 및 열유동 특성 (Flow Distribution and Heat Transfer Characteristic of the Microchannel Waterblock with Different Shape of Inlet)

  • 최미진;권오경;윤재호
    • 설비공학논문집
    • /
    • 제21권7호
    • /
    • pp.386-393
    • /
    • 2009
  • The present study has been studied on a thermal and flow characteristic of the microchannel waterblock with flow distributions in each channels. Results of a numerical analysis using the CFX-11 are compared with results of an experiment. Numerical analysis and experiment are conducted under an input power of 150 W, inlet temperature of $20^{\circ}C$ and mass flow rates of $0.7{\sim}2.0$ kg/min. Base temperature and pressure drop are investigated with standard deviations of mass flow rates in each channels of samples. The flow distribution and j/f factor of the sample 4 is increased by about 65.7% and 42.6%, compared to that of the reference model sample 3.

유동-구조 연성해석기법을 이용한 풍하중이 관절형 컨테이너 크레인에 미치는 영향에 관한 연구 (A Study on the Effect of Wind Load to an Articulated type Container Crane by Fluid-Structural Coupled Field Analysis)

  • 안태원;이성욱;한동섭;김태형;한근조
    • 한국항해항만학회지
    • /
    • 제32권1호
    • /
    • pp.23-27
    • /
    • 2008
  • 컨테이너 크레인의 설계 시 적용되는 하중 조건 중에서 풍하중이 가장 중요하게 고려되어지는바, 본 연구는 75m/s의 풍하중이 컨테이너 크레인에 작용 할 때 컨테이너 크레인의 구조적 안정성에 미치는 영향을 보다 정확하게 예측하기 위하여 유동-구조 연성해석을 실시하였다. 컨테이너 크레인에 작용하는 실제 유동현상을 고려하기 위하여 먼저 전산유동해석을 실시하였으며, 이를 통해서 얻어진 풍하중을 구조해석의 하중조건으로 적용하는 유동-구조 연성해석을 통하여 컨테이너 크레인 각 지지점에서의 반력을 도출하고 그 결과를 분석하였다. 사용된 모델은 주변 환경으로 인하여 컨테이너 크레인의 최대 고도가 제한 될 경우 사용되는 관절형 컨테이너 크레인이며 전산유동해석 및 유동-구조 연성해석 프로그램으로는 ANSYS ICEM CFD 10.0과 ANSYS CFX 10.0을 사용하였다.

Evaluation of the Femoral Stem Implant in Canine Total Hip Arthroplasty: A Cadaver Study

  • Cho, Hyoung Sun;Kwon, Yonghwan;Kim, Young-Ung;Kang, Jin-Su;Lee, Kichang;Kim, Namsoo;Kim, Min Su
    • 한국임상수의학회지
    • /
    • 제36권1호
    • /
    • pp.53-61
    • /
    • 2019
  • Total hip arthroplasty (THA) is a successful surgical treatment for both patients with chronical lameness and dogs who are nonresponsive to medical treatments, providing excellent joint function for returning dogs to the normal gait in 80% to 98% of hip dysplasia (HD) patients. The THA surgical implant system manufactured by BioMedtrix and Kyon are today widely accepted. When comparing the BioMedtrix biological fixation (BFX) system to the BioMedtrix cemented fixation (CFX) system, the many advantages of BFX, which include longer potential implant life, decreased risk of postoperative or later infection, and better implant stability, become evident. However, BFX implies a greater risk of femoral fracture during reaming and requires a more precise surgical technique to achieve good implant fit, given the press-fit nature of cementless THA. The purposes of this study are to both describe the mistakes and complications during stem implantation for beginner surgeons with both the BFX and the CFX systems and to document the initial result of 12 implantations in canine cadavers. Given the detailed evaluations of 3 specialists, who are Diplomate American College of Veterinary Surgeons (DACVS), only 3 of 11 stems were appropriately sized. Specifically, 6 stems were anteverted rather than being retroverted; further, although 7 stems were coaxial with the femoral long axis in the frontal plane, the other stems were in the varus at the frontal plane, with the proximal medial stem adjacent to the medial femoral cortex. Moderate angulation from the cranial to the caudal directions was found in 4 cases in the sagittal plane. Additionally, 1 case of femoral fissure and 1 case of perforated femoral cortex were reported. It is not easy for surgeons performing cementless THA for the first time to achieve a good result, even though they completed an educational course about it and given that catastrophic complications often occurred during early surgical clinical cases. Therefore, ex-vivo studies are sincerely required to get an expertise by rehearsing the preparation of the femoral envelop in isolated bones. Further studies should be conducted to achieve both highly accurate implant size and correct orientation during the preoperative planning. Additionally, surgeons' learning curve should be examined in future investigations.

격자형 금형의 냉각효과를 고려한 구형 LNG 탱크용 대형 알루미늄 후판의 열간성형해석 (FE-Analysis of Hot Forming of Al Large Thick Plate for Spherical LNG Tank Considering Cooling Performance of Grid-Typed Die)

  • 이정민;이인규;김대순;권일근;이선봉;김병민
    • 한국정밀공학회지
    • /
    • 제29권11호
    • /
    • pp.1190-1198
    • /
    • 2012
  • A hot forming of large thick Al plate using a grid-type hybrid die is a process to make a shell plate for the production of a spherical LNG tank. This process is characterized by using a grid-typed die with an additional air cooling system for reducing the cooling time of the heated plate after hot forming. The process consists of the plate's feeding, heating, forming and cooling in detail and each of them is continuously performed along the rail. This paper was designed to propose the analytical and experimental methods for determining the convection and interfacial heat transfer coefficients required in hot forming analysis of Al plate. These values in the analysis are to reproduce numerically the cooling performance of grid-typed die and cooling device. Interfacial heat transfer was obtained from the heat transfer experiments for different pressures and inverse analysis method. To verify the efficiency of the coefficient values obtained from above methods, FE analysis and experiment of the hot spherical-forming process were conducted for a small-scaled model. The convection coefficient was also calculated from flow analysis of air released by cooling device within grid-typed die using ANSYS-CFX.

열유동구조연성해석을 이용한 삼원촉매담체의 구조 해석 (The Structural Analysis of Three-Way Catalyst Substrate using Coupled Thermal-Fluid-Structural Analysis)

  • 이성룡;조석수
    • 한국산학기술학회논문지
    • /
    • 제16권5호
    • /
    • pp.3035-3043
    • /
    • 2015
  • 본 논문은 국내 승용차에 장착된 삼원촉매담체의 열적 구조 안전성을 평가한 것이다. 삼원촉매담체에 대한 열 유동 경계조건을 D-optimal 실험계획법로 결정한 뒤 이 값을 ANSYS CFX V11에 적용하여 촉매 온도 분포를 구하였다. 이러한 온도 분포를 ANSYS V11로 전달한 뒤 구조적 구속조건을 부여하여 담체의 열응력을 계산하였다. 이러한 열응력을 이용하여 삼원촉매담체의 재료강도분포와 실동하중조건하에서의 응력분포를 이용하여 해당 부품의 안전계수를 구하여 삼원촉매담체의 구조 안전성을 평가하였다. 본 연구에서 고려하는 삼원촉매담체는 구조적 안전계수가 0.275로, 발생 열응력이 설계 강도를 초과하고 있다. 따라서 삼원촉매담체는 설계 내구 수명 120,000km를 만족시키지 못하므로 본 부품에 대한 재설계가 요구된다.

디젤 분무와 천연 가스 분류의 거동 특성에 관한 기초 연구 (A Basic Study of the Behavior Characteristics of Diesel Spray and Natural-gas Jet)

  • 염정국;김민철
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.13-21
    • /
    • 2009
  • This basic study is required to examine spray or jet behavior depending on fuel phase. In this study, analyses of diesel fuel(n-Tridecane, $C_{13}H_{28}$) spray and natural gas fuel(Methane, $CH_4$) jet under high temperature and pressure are performed by a general-purpose program, ANSYS CFX release 11.0, and the results of these are compared with experimental results of diesel fuel spray using the exciplex fluorescence method. The simulation results of diesel spray is analyzed by using the combination of Large-Eddy Simulation(LES) and Lagrangian Particle Tracking(LPT) and of a natural gas jet is analyzed by using Multi-Component Model(MCM). There are two study variables considered, that is, ambient pressure and injection pressure. In a macroscopic analysis, the higher ambient pressure is, the shorter spray or jet tip penetration is at each time after start of injection. And the higher injection pressure is, the longer spray or jet tip penetration is at each time after start of injection. When liquid fuel is injected, droplets of the fuel need some time to evaporate. However, when natural gas fuel is injected, the fuel does not need time to evaporate. Gas fuel consists of minute particles. Therefore, the gas fuel is mixed with the ambient gas more quickly at the initial time of injection than the liquid fuel is done. The experimental results also validate the usefulness of this analysis.

  • PDF

Performance and Internal Flow Condition of Mini Centrifugal Pump with Splitter Blades

  • Shigemitsu, Toru;Fukutomi, Junichiro;Kaji, Kensuke;Wada, Takashi
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권1호
    • /
    • pp.11-17
    • /
    • 2013
  • Mini centrifugal pumps having a diameter smaller than 100mm are employed in many fields. But the design method for the mini centrifugal pump is not established because the internal flow condition for these small-sized fluid machines is not clarified and conventional theory is not suitable for small-sized pumps. Therefore, mini centrifugal pumps with simple structure were investigated by this research. Splitter blades were adopted in this research to improve the performance and the internal flow condition of mini centrifugal pump which had large blade outlet angle. The original impeller without the splitter blades and the impeller with the splitter blades were prepared for an experiment. The performance tests are conducted with these rotors in order to investigate the effect of the splitter blades on performance and internal flow condition of mini centrifugal pump. On the other hand, a three dimensional steady numerical flow analysis is conducted with the commercial code (ANSYS-CFX) to investigate the internal flow condition in detail. It is clarified from experimental results that the performance of the mini centrifugal pump is improved by the effect of the splitter blades. Blade-to-blade low velocity regions are suppressed in the case with the splitter blades and total pressure loss regions are decreased. The effects of the splitter blades on the performance and the internal flow condition are discussed in this paper.