• 제목/요약/키워드: CFD simulation

검색결과 1,724건 처리시간 0.027초

CFD 시뮬레이션을 이용한 풍하중 산정 시 변동풍속 프로파일에 관한 연구 (A Study on Fluctuating Wind Profile in CFD Simulation for Evaluating Wind Load)

  • 전두진;한상을
    • 한국공간구조학회논문집
    • /
    • 제21권1호
    • /
    • pp.51-59
    • /
    • 2021
  • In this paper, the effect of the turbulence intensity in across-wind direction on the wind load in CFD(Computational fluid dynamics) simulation was analyzed. 'Ansys fluent' software was used for CFD simulation. And the fluctuating wind speed applied to the simulation was generated according to Korean Design Standard and Von Karman wind turbulence model. The turbulence intensity in across-wind direction for simulation was applied from 0 to 100% of the turbulence intensity in along-wind direction. The analysis results showed that the turbulence intensity in across-wind direction had a particularly great effect on the wind load in across-wind direction.

3D City모델과 CFD 모델을 통합한 대기환경 시각화 연구 (A Study on Atmospheric Environment Visualization by Integrating 3D City Model and CFD Model)

  • 안승만;이호영;성효현;최영진;우정헌
    • 대한공간정보학회지
    • /
    • 제19권4호
    • /
    • pp.13-21
    • /
    • 2011
  • 3D City 모델로부터 CFD 모델 입력자료를 생성하여 모델링 품질을 향상시키고 CFD 모델링 결과를 3D 모델과 통합하여 사실적이고 쉽게 인지할 수 있는 시각화 방법에 대하여 연구하였다. 국토지리정보원에서 구축한 3D City 모델을 이용해 세밀도와 정확도가 향상된 CFD 모델 입력자료를 생산하여 적용함으로써 상세한 도시공간구조를 반영하는 향상된 CFD 모델을 생산하였다. CFD_NIMR_SNU 모델로부터 바람의 흐름과 오염물질 확산을 시뮬레이션 하였으며 3D City Model과 CFD 모델을 통합하여 동적으로 시각화 하였다. 본 대기환경 시각화 도구는 도시기후 계획 및 관리에 있어 의사결정을 위한 시각적 소통능력을 향상시켜 비용과 시간을 최소화할 것이다.

CFD모사 기법을 이용한 관내 혼화장치내 흐름 특성 평가 (Evaluation of Flow Characteristics within In-Line Mixer for Water Treatment using CFD Technique)

  • 박대진;박영오;박노석;김성수;왕창근
    • 상하수도학회지
    • /
    • 제22권3호
    • /
    • pp.351-358
    • /
    • 2008
  • The modified in-line mixer which was suggested in this study for small water treatment facilities was evaluated on the performance of coagulation. For the objectives of this research, computational fluid dynamics(CFD) simulation was applied for analysis of flow characteristics within the modified in-line mixer. For verifying the results of CFD simulation, wet tests for the pilot plant were conducted. The wet test was to measure the actual coagulant dispersion distribution on the overall cross-section at a distance of 5.5D from the chemical injection point. From the results of CFD simulation and wet test, it was shown that the coagulant dispersion within the modified in-line mixer was occurred more uniformly than within the existing PDM(Pump diffusion Mixer). The results have confirmed the modified in-line mixer had several advantages compared with the existing PDM in terms of dispersion efficiency.

곡관 연결 조건에 따른 디젤엔진 매연여과장치 입구 유속 분포의 CFD 해석 (A CFD Analysis of Flow Velocity at Inlet of a Diesel Particulate Filter according to the Curved Duct Connection Conditions)

  • 이수룡;고영남;이충훈
    • 한국철도학회논문집
    • /
    • 제12권4호
    • /
    • pp.457-464
    • /
    • 2009
  • 디젤 엔진 매연 필터의 입구부와 배출 가스 배출을 위한 배기관 연결을 직선 또는 곡선으로 형태로 연결하였을 때의 DPF 입구 유속 분포를 $STAR-CD^{(R)}$ 전산해석 프로그램을 사용하여 시뮬레이션하였다. 곡관의 형상을 나타내는 3 종류의 수치해석 용 격자 모델을 사용하여 DPF 입구에서의 유속 분포를 시뮬레이션 하였다. 피토관을 2차원 이송장치에 탑재하고 위치를 이동시키며 측정한 유속 분포와 동일한 조건에서 시뮬레이션한 결과와 비교하였다. DPF 입구와 $90^{\circ}$의 곡관이 연결된 조건에서 CFD 해석을 수행한 결과 입구 단면에서의 유속 분포가 말발굽 형태를 나타내었으며 최대 유속값이 DPF 중심축에서 약간 벗어난 위치에서 나타나고 있다. 이러한 CFD 해석결과는 실험 결과와 비교적 잘 일치하였다.

CFD를 이용한 Frisbee의 공력 특성에 대한 고찰(II) (CFD Study on Aerodynamic Characteristics of Frisbee (II))

  • 김철완;장병희;이장연
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 춘계 학술대회논문집
    • /
    • pp.114-118
    • /
    • 2005
  • CFD simulation was peformed for 2D and 3D flying and rotating frisbees. Multiple reference method(MRF) was utilized to consider the rotation of 3D model. Geometry change of 2D model shows dramatic increase of lift, but 3D simulation results for geometry change show decrease of lift and drag. Ground effect increases the lift of the frisbee being close to ground.

  • PDF

폐기물 층 연소와 노내 유동 해석 (Combined Bed Combustion and Gas Flow Simulation for a Grate Type Incinerator)

  • 류창국;신동훈;최상민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제20회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.67-75
    • /
    • 2000
  • Computational fluid dynamics(CFD) analysis of the thermal flow in a municipal solid waste(MSW) incinerator combustion chamber provides crucial insight on the incinerator performance. However, the combustion of the waste bed is typically treated as an arbitrarily selected profile of combustion gas. A strategy for simultaneous simulation of the waste bed combustion and the thermal flow fields in the furnace chamber was introduced to substitute the simple inlet condition. A waste bed combustion model was constructed to predict the progress of combustion in the bed and corresponding generation of the gas phase species, which assumes the moving bed as a packed bed of homogeneous fuel particles. When coupled with CFD, it provides boundary conditions such as gas temperature and species distribution over the grate, and receives radiative heat flux from CFD. The combined simulation successfully predicted the physical processes of the waste bed combustion and its interaction with the flow fields for various design and operating parameters, which was limited in the previous CFD simulations.

  • PDF

Transient CFD 모사기법을 이용한 정수지 최적설계 사례연구 (Case study on Remodeling Clearwell Hydraulic Structure using Transient CFD Simulation Technique)

  • 김선진;김성수;박노석;차민환;왕창근
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.425-432
    • /
    • 2010
  • From the results of tracer test for the existing clearwell in Y water treatment plant, $T_{10}$ and T10/T were calculated as 150 min and 0.24, respectively. Therefore it required the modification schemes for improving hydraulic efficiency, surrogated by $T_{10}$ and $T_{10}$/T, and disinfection performance. In this study, using transient CFD(Computational Fluid Dynamics) simulation technique, tracer tests on dynamic condition for the suggested schemes were simulated. From the results of simulation, it was revealed that 8~6 baffles are necessary to guarantee the disinfection ability in the existing clearwell. Also, installing orifice baffle in the vicinity of inlet could increase plug flow fraction within clearwell.

벽면 조도계수가 염소 접촉조 수리특성에 미치는 영향 연구 (Examining the effects of wall roughness on the hydraulic characteristics of chlorine contactor using Transient CFD Simulation Technique)

  • 채선하;임영택;차민환;김종오
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.759-765
    • /
    • 2011
  • In this study, in order to investigate the effects of wall roughness on the hydraulic characteristics of chlorine contactor, CFD simulation and tracer tests were conducted for both of reactors whose walls are made of concrete and lined with PE(Poly Ethylene). In the case of walls contacted with water being lined with PE (relatively lower roughness), the flow within reactor is closer to plug flow than that in the case of concrete walls (relatively higher roughness). Especially, the longer tail of C-curve from the results of transient CFD simulation can tell that Morill index in the case concrete walls is much higher than that in the case of walls be lined with lower roughness material.

CFD모사를 이용한 저수지 물순환장치 유동 설계 (Design of convection current circulation system in reservoir using CFD simulation)

  • 이요상
    • 환경영향평가
    • /
    • 제21권1호
    • /
    • pp.133-142
    • /
    • 2012
  • Convection Current Circulation System(CCCS) in stratified reservoir controls development of anaerobic condition and algal bloom during summer. In order to increase the CCCS effectiveness, we analyze diverse design parameters to make optimize the flow pattern in reservoir. In this study, we interpret the internal flow with installation and operation condition of CCCS based on CFD in reservoir. Design variables of CCCS is reservoir depth, stratification strength, distance of between CCCS and so on. Since reservoir depth and stratification strength in variables is depending on natural phenomenon, we evaluated current circulation effect by distance of CCCS and proposed the optimal design condition using CFD simulation. Flow and diffusion changes in water body was assessed by temperature and dye test. Changes in water floor temperature at 40m intervals was slowly descending over 37 hours. Dye diffusion simulation at 60m intervals, the radius of the spread between two devices were overlapped after 12 hours.

열원이 존재하는 작업장내 기류 및 온도장 예측 (Prediction of Airflow and Temperature Field in a Room With Convective Heat Source)

  • 정유진;하현철;김태형;유근종
    • 한국산업보건학회지
    • /
    • 제11권1호
    • /
    • pp.78-84
    • /
    • 2001
  • A CFD simulation of airflow and temperature field in a heated room has been described in this paper. The thermal wall jet created by a radiator greatly influences the airflow pattern, temperature distribution. The area close La a heat source has a higher risk of air-borne contamination and imposes a harmful effect on occupants in that area. The predicted flow field, temperature results show good agreement with the measured data. As the results were compared with experimental data, the applicability of CFD was satisfactorily verified. Also, the CFD simulation can capture the natural convective flow features. If a CFD simulation is applied ventilation design with a heat source, An effective design will be attained. Further study is required to improve the accuracy of CFD simulation.