• 제목/요약/키워드: CFD flow analysis

검색결과 1,846건 처리시간 0.028초

핵연료다발 유동혼합 날개 개발을 위한 CFD 응용 (CFD Application to Development of Flow Mixing Vane in a Nuclear Fuel Assembly)

  • 인왕기;오동석;전태현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.482-487
    • /
    • 2001
  • A CFD study was conducted to evaluate the nuclear fuel assembly coolant mixing that is promoted by the flow-mixing vanes on the grid spacer. Four mixing vanes (split vane, swirl vane, twisted vane, hybrid vane) were chosen in this study. A single subchannel of one grid span is modeled using the flow symmetry. The three mixing vanes other than swirl vane generate a large crossflow between the subchannels and a skewed elliptic swirling flow in the subchannel near the grid spacer. The swirl vane induces a circular swirling flow in the subchannel and a negligible crossflow. The split vane and the twisted vane were predicted to result in relatively larger pressure drop across the grid spacer. Since the average turbulent kinetic energy in the subchannel rapidly decreases to a fully developed level downstream of the spacer, turbulent mixing caused by the mixing vanes appears to be not as effective as swirling flow mixing in the subchannel. In summary, the CFD analysis represented the overall characteristics of coolant mixing well in a nuclear fuel assembly with the flow mixing vanes on the grid spacer. The CFD study is therefore quite useful for the development of an advanced flow-mixing vane.

  • PDF

이젝터 구동관로의 직경비와 끝단의 위치 변화에 따른 유동특성 (Flow Characteristics of Ejector Driven Pipe According to the Changes of Diameter Ratio and End Position)

  • 김노형
    • 한국유체기계학회 논문집
    • /
    • 제19권1호
    • /
    • pp.45-51
    • /
    • 2016
  • This study conducted CFD analysis on the mean velocity vector of distribution of the ejector driven pipe while changing the inlet velocity to 1 m/s at the diameter ratio of diffuser of 1:3, 1:2.25, 1:1.8 with the end position of driven pipe at 1, 1.253, 1.333, 1.467 respectively, which used $k-{\varepsilon}$/High Reynolds Number for the turbulence model, SIMPLE method for the analysis algorithm, and PIV experiment to verify the CFD analysis. As a result of the CFD analysis the optimum diameter ratio of ejector driven pipe was 1:3, the optimum end position of driven pipe was 1.333 for the diameter ratio of 1:3, 1:2.25, 1:1.8 and the PIV experiment obtained the same result as the CFD analysis. Therefore, the numerical analysis of the flow characteristics of ejector can be used for the optimum design implementation on ejector system.

차량용 전자식 솔레노이드 밸브 필터간의 유동특성에 관한 연구 (A Study on Flow Characteristics about Valve Filter for Electronic System Solenoid Structure)

  • 김병준;조행묵
    • 한국산학기술학회논문지
    • /
    • 제15권3호
    • /
    • pp.1294-1298
    • /
    • 2014
  • 향후 제작 될 솔레노이드 구조의 방향을 제시하고자 실험 및 유동 특성에 대한 비교 분석 연구가 진행 되어졌다. 실험값과 해석값의 비교 분석은 ANSYS CFD와 전자식 측정 기구를 이용하여 수행하였다. 구조의 3D 모델링은 CATIA V5R18을 이용하였으며, 유동구간의 격자 생성은 ICEM CFD 프로그램을 사용하였다. 유동해석 분석은 수치해석 프로그램인 ANSYS CFD를 이용하여 실험값에 대한 검증이 진행되었다. 실험값을 통해 정밀 필터구간에서 나타난 유량은 $0-10{\ell}/min$ 으로 나타났으며 유동해석결과 최대 $0.18{\ell}/min$로 나타났다. 유동 해석 결과와 실험값의 비교분석을 통해 유동환경에 보다 효율적인 솔레노이드 구조를 제시 할 수 있었다.

마이크로 모세관 유동 해석을 위한 CFD-VOF 모텔 응용 (Application of CFD-VOF Model to Autonomous Microfluidic Capillary System)

  • 정자훈;임예훈;한상필;석지원;김영득
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.224-229
    • /
    • 2004
  • The objective of this work is not only to perform feasibility studies on the CFD (computational fluid dynamics) analysis for the capillary system design but also to provide an enhanced understanding of the autonomous capillary flow. The capillary flow is evaluated by means of the commercial CFD software of FLUENT, which includes the VOF (volume-of-fluid) model for multiphase flow analysis. The effect of wall adhesion at fluid interfaces in contact with rigid boundaries is considered in terms of static contact angle. Feasibility studies are first performed, including mesh-resolution influence on pressure profile, which has a sudden increase at the liquid/gas interface. Then we perform both 2D and 3D simulations and examine the transient nature of the capillary flow. Analytical solutions are also derived for simple cases and compared with numerical results. Through this work, essential information on the capillary system design is brought out. Our efforts and initial success in numerical description of the microfluidic capillary flows enhance the fundamental understanding of the autonomous capillary flow and will eventually pave the road for full-scale, computer-aided design of microfluidic networks.

  • PDF

CFD를 이용한 쌍축 컨테이너선 주위의 유동계산 (Computation of Flow around a Container Ship with Twin-Skegs using the CFD)

  • 김희택;김형태
    • 대한조선학회논문집
    • /
    • 제44권4호
    • /
    • pp.370-378
    • /
    • 2007
  • In this study. a numerical analysis has been performed for the turbulent flow around a 15,000TEU twin-skeg container ship using a commercial CFD code. FLUENT. The computed results have been compared with the model test data from MOERI. We investigated viscous resistance coefficient. wake distribution and characteristics of the shear flow according to the grid numbers. Although the free surface is approximated by the plane of symmetry in this work. the calculated axial velocity and transverse vector show a good agreement with the MOERI experimental data except for the region of 0.9 level of axial velocity at the propeller plane. The numerical analysis show that commercial CFD code is useful tool for the evaluation of complex hull form with twin-skegs.

진공청소기 모터 하우징 내부 온도상승 개선을 위한 연구 (A Study for the Improvement of Temperature Distribution in the Motor Housing of Vacuum Cleaner)

  • 김주신;김성근;이응호;주보경
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.425-429
    • /
    • 2008
  • The present study has been conducted to improve temperature distribution in the motor housing of vacuum cleaner and reduce the development period by CFD analysis. CFD analysis is performed to investigate the thermal flow pattern in the motor housing and validated by experiments. The validation of CFD analysis is conducted by comparing the temperature distribution on motor housing cover. Through the present study the CFD analysis procedure in the motor housing of vacuum cleaner is established and various experimental materials are obtained. These analysis results can be used effectively as design factors of vacuum cleaner.

  • PDF

CFD를 활용한 브러쉬 요소의 누설유량 예측 해석 (CFD Analysis of Leakage Prediction for Brush Element)

  • 김결;하태웅
    • 한국유체기계학회 논문집
    • /
    • 제20권2호
    • /
    • pp.11-16
    • /
    • 2017
  • The accurate prediction of leakage flow through the brush element of brush seal at the steam turbine is important to find optimum design parameters for increasing an efficiency. In this study, CFD analysis method using commercial software FLUENT is proposed to predict leakage through the brush element. Since the brush element has a complex three-dimensional shape with many bristle assemblies, it is difficult to analyze the flow field. Therefore, if the brush element is assumed to be porous medium region, the analysis time can be shortened. Two determination methods of resistance coefficients of the Darcian porous medium equation are suggested. By comparing the 2D and 3D CFD analysis results for the leakage of the brush element using the two resistance coefficient determination methods, the effectiveness of the analysis for the porous medium assumption is proved.

Y형 세대별 정유량 밸브 개발에서의 CFD의 활용 (CFD for Y-type Constant Flowrate Valve Design)

  • 권우철;이병휘
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.488-491
    • /
    • 2004
  • Numerical analysis of the three dimensional turbulent flow field in a complex valve shape is carried out to confirm the flow field whether the designed valve shape is good or not. The simulation of the incompressible flow in a constant flowrate control valve is performed by using the commercial code, FLUENT/UNS 6.0. The results of flow field show the designed valve has some problems, therefore these will be good data for new valve design.

  • PDF

PIV를 이용한 만곡형 전개판의 유동장 계측에 관한 연구 (Study on the Measurements of Flow Field around Cambered Otter Board Using Particle Image Velocimetry)

  • 박경현;이주희;현범수;노영학;배재현
    • 수산해양기술연구
    • /
    • 제38권1호
    • /
    • pp.43-57
    • /
    • 2002
  • 본 연구는 고성능 전개판을 개발하기 위하여 전개판 주변의 유동장을 계측할 수 있는 해석 방법을 제시하고자 하였다. 실험 방법으로는 CFD를 이용한 유동장의 수치 해석과 유동장의 정량적, 정성적 계측이 가능한 PIV 실험방법을 사용하였다. 본 실험에서는 전개판 주변의 가시화된 영상을 PIV 기법을 이용한 화상처리로 유동특성을 해석하였으며, 이 결과를 CFD에 의한 해석 결과와 유동 패턴을 비교하였다. 또한, 회류 수조에서의 양력 계수 및 항력계수의 계측 결과를 상호 비교 하였다. 그 결과, 수치 해석된 결과와 PIV의 실험 결과는 정성적으로 매우 잘 일치하였으며, 물리적으로 타당성을 확인할 수 있었다. 그 결과는 다음과 같다. (1) 전개판의 유동장 분석을 위하여 레이저 광원을 이용한 가시화 실험을 실시하고, PIV 기법으로 화상분석을 실시하였으며, 유동입자의 흐름으로도 충분한 정성적인 유체운동의 경향을 파악할 수 있었다 (2) PIV해석결과가 정량적인 결과이므로 이를 다양한 후처리 방법을 통해 속도벡터장, 순간 유동장, 평균 와도로 나타내어 유동장의 변화를 확인할 수 있었다. (3) 최대전개력계수가 나타난 영각 24$^{\circ}$에서 비교한 CFD와 PIV 해석 결과, 유동 패턴은 유사하였고, 두 경우 모두 전개판 후연에서 약간의 경계층 박리가 발생하였으나 양호한 흐름을 보였다. (4) PIV에 의한 속도 벡터도, 순간 유선도, 평균 와도로 후처리한 결과, 영각 24$^{\circ}$에서부터 경계층 박리 현상이 일어나기 시작하여, 영각 28$^{\circ}$이상이 되면 심하게 전연으로 발생지점이 이동하게 되고, 그 폭도 확대됨을 확인할 수 있었다.

흡기포트 및 밸브 형상에 따른 정상 유동 특성 (Numerical analysis of flow characteristics with intake port and valve design)

  • 이상진;김성철;김득상;엄인용;조용석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.921-927
    • /
    • 2001
  • Steady flow bench test is a practical, powerful and widely used test in most engine manufacturers to give a design concept of a new engine. In order to use steady data as a performance index, it is necessary to build some database, which can correlate the port characteristics with engine data. However, it is very hard to investigate all port and valve shapes with experimental tools. The steady flow scheme is relatively simple and its results are bulk ones such as flow rate and momentum of flow. Therefore a CFD code can be easily applied to the port evaluation. In this study, the steady flow test was simulated through two and three-dimensional analysis on intake port design for comparing with experimental data and confirming the feasibility of applying analytic method. For this purpose, the effect of valve curvature on flow rate was estimated by a CFD code. There results were compared with those of real steady flow tests. As a result, the 2-D analysis described the phenomena qualitatively well, and also the results of 3-D analysis were almost consistent with experimental data.

  • PDF