• Title/Summary/Keyword: CFD flow analysis

Search Result 1,846, Processing Time 0.037 seconds

A CFD Analysis of the Oil Flow in a Hydraulic Shock Absorber (유압 완층기 내에서의 오일 유동에 대한 CFD 해석)

  • Park, K.T.;Park, T.J.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.20-26
    • /
    • 2008
  • Various types of hydraulic shock absorbers are widely used in many fields because of its numerous advantages. However, in order to design adequate damping characteristics, accurate flow data near the orifices are required essentially. In this paper, a commercial computational fluid dynamics(CFD) code, FLUENT is adopted to investigate the flow characteristics near orifices of a shock absorber. Static pressure and velocity vector distributions, fluid path lines are presented for compression/tension strokes and various piston speeds. In order to validate the result of analysis, the numerically obtained damping forces are compared with those of analytical estimations obtained by modified Bernoulli equation. The results reported herein will provide better understanding of the detailed flow fields within shock absorber, and the CFD analysis method proposed in this paper can be used in the design of other types of hydraulic shock absorber.

  • PDF

Rotordynamic Analysis of See-through-type Labyrinth Seal Using 3D CFD (3D CFD를 활용한 관통 래버린스 실의 회전체 동역학적 해석)

  • Ha, Tae Woong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.44-50
    • /
    • 2015
  • Labyrinth seals are commonly used in various kinds of turbomachinery to reduce leakage flow. In the present 3D CFD analysis of see-through-type labyrinth air seal, the methodology of determining leakage and rotordynamic coefficients is suggested with the relative coordinate system for steady-state simulation. The leakage flow and rotordynamic forces predicted by using different solvers and turbulent models of FLUENT are compared with the results of the existing bulk-flow analysis code LABYSEAL.FOR and experiment. The present CFD result of direct stiffness(K) shows only improvement in prediction. The results of leakage and rotordynamic coefficients as well as computing time are sensitive against the used solver and turbulent model.

CFD-based Flow Simulation Study of Fuel Cell Protective Gas (CFD를 활용한 연료전지 모듈 보호가스 유동 연구)

  • Kwon, Kiwook;Lim, Jongkoo;Park, Jongcheol;Shin, Hyun Khil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.86.1-86.1
    • /
    • 2011
  • To improve the safety, the fuel cell operate inside a pressurized enclosure which contains inert gas so called protective gas. The protective gas not only prevents the mixture of hydrogen and oxygen, but also removes the water in the vessel with the condenser. This study presents the details of the flow optimization in order to reduce the humidity in the fuel cell housing. The protective gas flow in the fuel cell container is studied by Computational Fluid Dynamics(CFD) simulations. This study focuses on optimizing the geometry of an protective gas circulation system in fuel cell module to reduce the humidity in the vessel. CFD analysis was carried out for an existing model to understand the flow behavior through the fuel cell system. Based on existing model CFD results, geometrical changes like inlet placement, optimization of outlet size, modification of fuel cell module system are carried out, to improve the flow characteristics. The CFD analysis of the optimized model is again carried out and the results show good improvement in protective gas flow behavior.

  • PDF

PERFORMANCE IMPROVEMENT OF A RANGE HOOD SIROCCO FAN BY CFD FLOW ANALYSIS (렌지후드의 성능개선을 위한 시로코 펜 주위의 유동해석)

  • Han, B.Y.;Park, J.W.;Lee, M.S.;Park, H.K.
    • Journal of computational fluids engineering
    • /
    • v.13 no.4
    • /
    • pp.72-79
    • /
    • 2008
  • This study is to investigate the air flow around a sirocco fan which is used in a range hood. The main object of the study is to improve the flow rate of the fan by analysis of unsteady 3-dimensional incompressible flow. Overall analysis is carried out using CFD method. For this, we used a commercial code, SC/Tetra, and used a sliding mesh method to give the same condition as an actual state. First, verification of the CFD results is done by comparing the experimental data with the numerical data for the suction flow rate. It is confirmed that two results are well consistent. Then for the improvent of flow rate, the effect of shape factors such as diameter ratio of fan, geometry of case, cut-off aperture and guide angle of case exit on the suction flow rate was considered. Especially, for a new design of housing, the principle of Archimedes spiral was used. The overall analysis was applied to a new design of housing, and the result showed an increase of flow rate by 10.7%.

ANALYSIS ON CHARACTERISTICS OF AN AXIAL FLOW FAN THROUGH CFD ANALYSIS INCORPORATED WITH MOTOR CHARACTERISTICS (모터의 특성을 고려한 CFD 해석에 의한 축류홴 성능해석)

  • Kim, J.H.;Hur, N.;Kim, W.
    • Journal of computational fluids engineering
    • /
    • v.15 no.4
    • /
    • pp.109-114
    • /
    • 2010
  • In a fan design, CFD analysis, which is very useful for mechanical design relating to the heat and fluid dynamics, is one of the most popular tools. However, since the CFD analysis is conventionally carried out with the constant fan speed condition, the speed change, induced by the air flow rate and motor characteristics, is hardly modeled. And, consequently, the remarkable difference exist between analysis and experimental results. In this paper, we has proposed a method of setting the varying fan speed as a boundary condition considering air flow rate and motor torque-speed characteristics. The effectiveness of the proposed method is verified by comparison with experimental results.

Pump performance analysis of Axial Flow Blood Pump using CFD (CFD를 활용한 축류형 혈액펌프의 펌프 특성 해석)

  • 최승한;김동욱
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.288-290
    • /
    • 2003
  • Artificial heart is divided by pulsation flow type and continuous flow type according to blood circulation pattern. Axial flow blood pump is a kind of continuous flow type artificial heart. Axial flow blood pump would be different pump performance according to impeller's shape and rotating velocity. Pump performance be able to compare by flow rate according to differential pressure and Impeller's rotating velocity. It confirms Impeller model of better efficiency according to compare Pump performance of axial flow blood pump using CFD with actual experiment result.

  • PDF

Analysis of newly designed CDI cells by CFD and its performance comparison

  • Kwon, Se Hwan;Rhim, Ji Won
    • Membrane and Water Treatment
    • /
    • v.7 no.2
    • /
    • pp.115-126
    • /
    • 2016
  • In this study, computational fluid dynamics (CFD) analysis was conducted to investigate the flow pattern and to find the occurrence of dead zones in an existing capacitive deionization (CDI) cell. Newly designed cells-specifically designed to avoid dead zones-were analyzed by CFD in accordance with the flow rates of 15, 25 and 35 ml/min. Next, the separation performances between the existing and newly designed cell were compared by conducting CDI experiments in terms of salt removal efficiency at the same flow rates. Then, the computational and experimental results were compared to each other. The salt removal efficiencies of the hexagon flow channel 1 (HFC1) and hexagon flow channel 2 (HFC2) were increased 88-124% at 15 ml/min and 49-50% at 25 ml/min, respectively. There was no difference between the existing cell and the foursquare flow cell (FFC) at 35 ml/min.

CFD APPLICATION TO THE REGULATORY ASSESSMENT OF FAC-CAUSED CANDU FEEDER PIPE WALL THINNING ISSUE

  • Kang, Dong-Gu;Jo, Jong-Chull
    • Nuclear Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.37-48
    • /
    • 2008
  • Flow fields inside feeder pipes have been simulated numerically using a CFD (computational fluid dynamics) code to calculate the shear stress distribution, which is the most important factor in predicting the local regions of feeder pipes highly susceptible to FAC (flow-accelerated corrosion)-induced wall thinning. The CFD approach, with schemes used in this study, to simulate the flow situations inside the CANDU feeder pipes has been verified as it showed a good agreement between the investigation results for the failed feedwater pipe at Surry unit 2 plant in the U.S. and the CFD calculation. Sensitivity studies of the three geometrical parameters, such as angle of the first and second bends, length of the first span between the grayloc hub and the first bend, and length of the second span between the first and the second bends have been performed. CFD analysis reveals that the local regions of feeder pipes of Wolsung unit 1 in Korea, on which wall thickness measurements have been performed so far, are not coincident with the worst regions predicted by the present CFD analysis located in the connection region of straight and bend pipe near the inlet part of the bend intrados. Finally, based on the results of the present CFD analysis, a guide to the selection of the weakest local positions where the measurement of wall thickness should be performed with higher priority has been provided.

Three-dimensional Analysis of Flow Characteristics for Intake Valve Design (흡기밸브 형상에 따른 3차원 유동특성 해석)

  • 김득상;이상진;조용석;엄인용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.4
    • /
    • pp.1-6
    • /
    • 2003
  • Steady flow bench test is a practical, powerful and widely used in most engine manufacturers to give a design concept of a new engine. In order to use steady data as a performance index, it is necessary to build some database, which can correlate the port characteristics with engine data. However, it is very difficult to investigate all port shapes with experimental tools. The steady flow scheme is relatively simple and its results are bulk ones such as flow rate and momentum of flow. Therefore a CFD code can be easily applied to the port evaluation. In this study, the steady flow test was simulated through three-dimensional analysis on intake port design for comparing with experimental data and confirming the feasibility of applying analytic method . for this purpose, the effect of valve curvature on flow rate was estimated by a CFD code. Numerical results were compared with those of real steady flow tests. As a result, the results of 3-D analysis were almost consistent with experimental data.

ASSESSMENT OF CORE BYPASS FLOW IN A PRISMATIC VERY HIGH TEMPERATURE REACTOR BY USING UNIT-CELL EXPERIMENT AND CFD ANALYSIS (단위-셀 실험과 전산유체해석을 통한 블록형 초고온가스로의 노심우회유량 평가)

  • Yoon, S.J.;Jin, C.Y.;Kim, M.H.;Park, G.C.
    • Journal of computational fluids engineering
    • /
    • v.14 no.2
    • /
    • pp.59-67
    • /
    • 2009
  • An accurate prediction of the bypass flow is of great importance in the VHTR core design concerning the fuel thermal margin. Nevertheless, there has not been much effort in evaluating the amount and the distribution of the core bypass flow. In order to evaluate the behavior and the distribution of the coolant flow, a unit-cell experiment was carried out. Unit-cell is the regular triangular section which is formed by connecting the centers of three hexagonal blocks. Various conditions such as the inlet mass flow rate, block combinations and the size of bypass gap were examined in the experiment. CFD analysis was carried out to analyze detailed characteristics of the flow distribution. Commercial CFD code FLUENT 6.3 was validated by comparing with the experimental results. In addition, SST model and standard k-$\varepsilon$ model were validated. The results of CFD simulation show good agreements with the experimental results. SST model shows better agreement than standard k-$\varepsilon$ model. Results showed that block combinations and the size of the bypass gap have an influence on the bypass flow ratio but the inlet mass flow rate does not.