• Title/Summary/Keyword: CFD 모델검증

Search Result 126, Processing Time 0.025 seconds

Development of CFD Model for Estimation of Cooling Effect of Fog Cooling System in Greenhouse (온실 포그냉방시스템의 냉방효과 예측을 위한 CFD 모델의 개발)

  • 유인호;김문기;권혁진;김기성
    • Journal of Bio-Environment Control
    • /
    • v.11 no.2
    • /
    • pp.93-100
    • /
    • 2002
  • This study was carried out not only to develop CFD model for numerically simulating fog cooling system but also to verify the validity of the developed model by data measured in fag cooling greenhouse. In addition the developed model was applied to investigate the effects of spraying water temperature, spraying water amount, spraying interval and evaporation percentage on the performance of the fog cooling system. According to the simulation results, the temperature differences between the measured and predicted temperatures at each measurement point were $0.1~1.4^{\circ}C$ in case of no shading and $0.2~2.3^{\circ}C$ in close of shading. The humidity differences were 0.3~6.0% and 0.7~10.6%, respectively in the cases of no shading and shading. Because the predicted data showed a good agreement with the measured ones, the developed model is supposed to be able to predict the cooling effect of the fog cooling system. The performance of fog cooling system was greatly influenced by spraying water amount, spraying interval and evaporation percentage, but it was not influenced by spraying water temperature.

Investigation on the Hydrodynamic Behaviors of the Clarifier with an Interior Baffle in WWTP by using of Radiotracer $^{99m}Tc$ ($^{99m}Tc$ 추적자를 이용한 하수처리 시설 내 침전조의 정류벽 설치 유무에 따른 유체거동 변화측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.117-122
    • /
    • 2007
  • The hydrodynamic behaviors of the clarifier with an interior baffle in a wastewater treatment plant was investigated by using a radiotracer $^{99m}Tc$(30 40 mCi) to verify the results of CFD(computational fluid dynamics) modelling in the previous study. The clarifier model was manufactured with consideration to the hydraulic similarity(1/21) of a real plant($L{\times}W{\times}H:2.6{\times}0.4{\times}0.2m$). By installation of an interior baffle to the clarifier, the strong density current at the bottom of the clarifier decreased substantially and increased the area of sludge settling zone, which were visualized successfully from the radiotracer experiment. Also the portion of short circuit stream changed from 48 % to 32 % and the mean residence time of sludge decreased from 940 sec to 810 sec, which corresponds to the results of CFD modelling. As a result, it is anticipated that radiotracer technology can be used as an important tool for designing new wastewater treatment plants and verifying their performances after structural modifications.

Validation of applying Canopy model to predict wind environment of pedestrian level by CFD simulation (보행자 레벨의 풍환경 예측 시 Canopy Model을 적용한 CFD 시뮬레이션 타당성 검증)

  • Jung, Su-Hyeon;Hong, In-Pyo;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.345-353
    • /
    • 2012
  • Recently rapid urbanization facilitates development of high-rise building complex including apartment and office building in urban area. Many problems related with high-rise building are reported. Especially, unpleasant strong winds in pedestrian area are frequently encountered around the high-rise building. CFD simulation methods are used to analyze the wind environment of pedestrian level in high-rise building block. However the results show differences between CFD and measurement. The reason for the difference is that conventional CFD simulation couldn't consider the effect of trees, shrubs and plants which affect the wind environment. Canopy model is a solution to solve the limitation of CFD analysis. In this paper, the canopy model to predict wind environment of pedestrian level by CFD simulation will be proposed and the validity will be analyzed by comparison of measurement and CFD prediction.

  • PDF

The Prediction of Hydrodynamic Forces Acting on Ship Hull Undergoing Lateral Berthing Maneuver Using CFD (CFD을 이용한 선박 접이안시 유체력 추정에 관한 연구)

  • 이윤석;정겸광행;공길영;김순값;이충로
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2003.05a
    • /
    • pp.132-138
    • /
    • 2003
  • In order to evaluate properly ship motion relating to the berthing maneuver, the hydrodynamic forces acting on ship hull in berthing maneuver need to be estimated rightly. CFD has been employed for time-domain simulation of transient flow induced by Wigley model moving laterally from rest in shallow water. The numerical solutions successfully captured not only the characteristics of the transitional hydrodynamic forces but also some interesting features of the flow field around a berthing ship according to the water depth. In this paper, the consideration is carried out on the approximate formula based on the CFD results, which can estimate hydrodynamic forces especially lateral drag coefficient starting from the rest to the uniform movement.

  • PDF

Assessment of CFD Estimation Capability for the Local Loss Coefficients of Sudden Contraction and Expansion (급격 확대 및 축소관의 압력손실계수에 대한 전산유체역학 해석의 예측성능 평가)

  • Kim, Hyun-Jung;Park, Jong-Pil
    • Applied Chemistry for Engineering
    • /
    • v.21 no.3
    • /
    • pp.258-264
    • /
    • 2010
  • Most of fluid systems, such as P&ID in ships, power plants, and chemical plants, consist of various components. The components such as bends, tees, sudden-expansions, sudden-contractions, and orifices contribute to overall pressure loss of the system. The local pressure losses across such components are determined using a pressure loss coefficient, k-factor, in lumped parameter models. In many engineering problems Idelchik's k-factor models have been used to estimate them. The present work compares the k-factor based on CFD calculation against Idelchik's model in order to confirm whether a commercial CFD package can be used for pressure loss coefficient estimation of complex geometries. The results show that RSM is the best appropriate for evaluating pressure loss coefficient. Commercial CFD package can be used as a tool evaluating k-factor even though the accuracy is influenced by a turbulence model.

Computational Fluid Dynamics(CFD) Simulation for a Pilot-scale Selective Non-catalytic Reduction(SNCR) Process Using Urea Solution (요소용액을 이용한 파일럿규모 SNCR 공정에 대한 CFD 모델링 및 모사)

  • Nguyen, Thanh D.B.;Kang, Tae-Ho;Lim, Young-Il;Kim, Seong-Joon;Eom, Won-Hyeon;Yoo, Kyung-Seun
    • Korean Chemical Engineering Research
    • /
    • v.46 no.5
    • /
    • pp.922-930
    • /
    • 2008
  • The selective non-catalytic reduction(SNCR) performance is sensitive to the process parameters such as flow velocity, reaction temperature and mixing of reagent(ammonia or urea) with the flue gases. Therefore, the knowledge of the velocity field, temperature field and species concentration distribution is crucial for the design and operation of an effective SNCR injection system. In this work, a full-scale two-dimensional computational fluid dynamics(CFD)-based reacting model involving a droplet model is built and validated with the data obtained from a pilot-scale urea-based SNCR reactor installed with a 150 kW LPG burner. The kinetic mechanism with seven reactions for nitrogen oxides($NO_x$) reduction by urea-water solution is used to predict $NO_x$ reduction and ammonia slip. Using the turbulent reacting flow CFD model involving the discrete droplet phase, the CFD simulation results show maximum 20% difference from the experimental data for NO reduction. For $NH_3$ slip, the simulation results have a similar tendency with the experimental data with regard to the temperature and the normalized stoichiometric ratio(NSR).

Development of Cabin Temperature Alteration Simulation Model for Position Optimization of Air Conditioner (Part I) (공조장치 위치 최적화를 위한 트랙터 캐빈 온도변화 시뮬레이션 모델 개발 (I))

  • Oh, Joo Seon;Chung, Woo Jin;Park, Seong Un;Park, Young Jun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.81-81
    • /
    • 2017
  • 본 연구는 전산유체역학(CFD)을 이용하여 트랙터 캐빈 내부의 온도 변화 시뮬레이션 모델을 개발하고 이를 통해 공조장치의 위치를 최적화 하는 것을 목적으로 하였다. 자동차나 열차를 대상으로 시뮬레이션을 이용한 차량 내부의 유동 해석 연구 사례는 많으나, 트랙터를 대상으로 한 연구 사례는 적다. 이에 트랙터의 공조장치를 설계하고 그 성능을 검증할 때 시뮬레이션 모델을 활용한다면, 인력, 시간 등의 손실을 줄일 수 있을 것이다. 본 연구에서는 상용 CFD 프로그램을 활용하여 공조 장치의 위치에 따른 세 가지 트랙터 캐빈 모델을 제작한 뒤, 각각의 모델에 대해서 열 유동 해석을 수행하였다. 시뮬레이션 결과가 실제 트랙터의 시험 결과와 비슷한 경향을 보이고 있음을 확인할 수 있었으며 이를 통해 모델의 적합성을 확인하였다. 또한 세 가지의 캐빈 모델 중 탑승자에게 가장 쾌적한 환경을 제공할 수 있는 모델은 기존의 국내 트랙터와 같은 천정부에 공조 장치가 있는 것이 아니라, 핸들이 있는 전면부에 위치하는 것이 가장 적합하다는 것을 확인할 수 있었다

  • PDF

Analysis of Temperature Gradients in Greenhouse Equipped with Fan and Pad System by CFD Method (CFD 기법을 이용한 팬 앤 패드 냉방 온실의 온도경사 분석)

  • Nam Sang Woon;Giacomelli Gene A.;Kim Kee Sung;Sabeh Nadia
    • Journal of Bio-Environment Control
    • /
    • v.14 no.2
    • /
    • pp.76-82
    • /
    • 2005
  • Evaporative cooling pad system is one of the main cooling methods in greenhouses and its efficiency is very high. However, it has some disadvantages such as greenhouse temperature distributions are not uniform and installation cost is expensive. In this study, a CFD simulation model f3r predicting the air temperature distribution in the fan and fad cooling greenhouse was developed. The model was calibrated and validated against experimental data and a good fit was obtained. The influence of different outside wind, fan and pad height, ventilation rate, shading, and greenhouse length, were then examined. In order to reduce the internal temperature gradients, it is desired that the prevail wind direction and the fan and pad heights are considered. The simulation indicates that high ventilation rates and shading contribute to reduce the temperature gradients in the fan and pad cooling greenhouse. In order to maintain the desired greenhouse temperature, the pad-to-fan distance should be restricted according to the design climate conditions, shading and ventilation rates. The developed CFD model can be a useful tool to evaluate and design the fan and pad systems in the greenhouses with various configurations.

A Numerical Study on Wind Pressure Characteristics of Super-tall Protype Model considering the Effect of Turbulence Intensity (난류강도의 영향을 고려한 초고층 프로토타입 모델의 풍압특성에 관한 수치 해석적 연구)

  • Jeong, So-Young;Lee, Kyung-Soo;Han, Sang-Eul
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.6
    • /
    • pp.659-667
    • /
    • 2011
  • Wind tunnels tests have been evaluating wind load estimation by discussing the most important design elements in very tall buildings. Such tests have some uncertainties, however, with respect to the data of the reduced model and the calculated empirical values. In contrast, CFD analysis can simulate the actual scale and shorten the time of simulation. Nevertheless, the utilization of CFD analysis is negligible because of its low reliability. In this paper, the reliability of CFD analysis will be proven by comparing the results of a wind tunnel test and CFD analysis for the prototype models shown in previous studies. The effect of the turbulence intensity on the reliability is also presented.

Aerodynamic Characteristics of Basic Airfoils for Agricultural Helicopter using Wind-tunnel Test and CFD Simulation (풍동실험과 CFD 시뮬레이션을 이용한 농용 헬리콥터 기본 익형의 공력특성 고찰)

  • Won, Yong Sik;Koo, Young Mo;Haider, B.A.;Sohn, Chang Hyun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.54-54
    • /
    • 2017
  • 본 연구는 무인 헬리콥터의 양력을 개선하기 위한 기초 단계로서 V1505A 및 V2008B 기본 두 익형의 400 mm 블레이드 섹션에 해당하는 모델에 대한 풍동실험을 실시하여 양력, 항력 및 동력특성을 분석하고 CFD 시뮬레이션의 결과와 비교하고 검증하였다. 시뮬레이션은 풍동 실험과 유사하게 설정하기 위하여 400 mm 블레이드 섹션의 양 끝을 벽으로 제한하여 3차원 와류현상을 억제하여 모델을 구성하였고, 시뮬레이션의 결과와 비교하여 모델을 검증하였다. 사용된 모델은 로터로부터 $Re=0.32{\times}10^6$ 영역까지는 aminar 모델을 사용하였으며, 그 이후 영역역(>$Re=0.32{\times}10^6$)은 양력 및 저항의 급격한 변화를 올바로 포착할 수 있다는 S-A 모델을 적용하여 확장하였다. 시뮬레이션의 격자는 유동 현상에 있어 박리로 야기된 와류 현상을 관찰하기 위하여 익형 주변에 접하는 부분에 격자를 집중시켰다. 시뮬레이션 방법은 유속은 36~141 m/s 까지 5 수준으로 하였으며, 받음각은 $0{\sim}16^{\circ}$로 7 수준으로 변화 시키면서 공력계수 및 동력을 분석하였다. 양력분석에 있어 익형 V1505A에 비해 익형 V2008B의 특성이 우수하였으나, 익형 V1505A는 실속 이후 양력이 급격히 떨어지지 않고 유지되는 특성을 보였다. 익형 V2008B는 낮은 받음각에서 높은 공력과 낮은 항력을 나타냈다. 동력 분석 결과로 익형 V1505A의 유도동력은 총 동력의 56~72%를 차지하고, 형상동력은 총 동력의 27~43%를 차지하였다. 익형 V2008B는 유도동력은 총 동력의 66~81%를 차지하고, 형상동력은 총 동력의 18~33%를 차지하였다. 익형 V2008B이 익형 V1505A보다 유도동력은 크며, 형상동력은 적게 나와 상대적으로 효율적이라 할 수 있다. 헬리콥터 동력원의 규모는 법률적인 총중량에 의하여 제한되므로 일반적인 농용 소형 무인 헬리콥터 엔진의 사양인 24.5 kW (32PS)를 적용한다면, 익형 V1505A은 받음각 $8{\sim}10^{\circ}$에서 그리고 익형 V2008B은 $7{\sim}9^{\circ}$정도에서 받음각이 제한되며 이때 총 양력은 1200~1300 N 정도로 예상된다.

  • PDF